Dental Materials : Official Publication... Dec 2023The objective is to compare the preventive effect on secondary caries of glass ionomer cement (GIC) restorations with amalgam or resin-composite restorations. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The objective is to compare the preventive effect on secondary caries of glass ionomer cement (GIC) restorations with amalgam or resin-composite restorations.
METHODS
Two independent researchers conducted a systematic search of English publications in PubMed, Web of Science, Cochrane and Scopus. They selected randomized clinical trials comparing secondary caries incidences around GIC restorations (conventional GIC or resin-modified GIC) with amalgam or resin-composite restorations. Meta-analysis of the secondary-caries incidences with risk ratio (RR) and 95% confidence interval (95% CI) as the effect measure was performed.
RESULTS
This review included 64 studies. These studies included 8310 GIC restorations and 5857 amalgam or resin-composite restorations with a follow-up period from 1 to 10 years. Twenty-one studies with 4807 restorations on primary teeth and thirty-eight studies with 4885 restorations on permanent teeth were eligible for meta-analysis. The GIC restorations had a lower secondary caries incidence compared with amalgam restorations in both primary dentition [RR= 0.55, 95% CI:0.41-0.72] and permanent dentition [RR= 0.20, 95% CI:0.11-0.38]. GIC restorations showed similar secondary caries incidence compared with resin-composite restorations in primary dentition [RR= 0.92, 95% CI:0.77-1.10] and permanent dentition [RR= 0.77, 95% CI:0.39-1.51]. Conventional GIC restorations showed similar secondary caries incidence compared with resin-modified GIC-restored teeth in both primary dentition [RR= 1.12, 95% CI:0.67-1.87] and permanent dentition [RR= 1.63, 95% CI:0.34-7.84].
CONCLUSIONS
GIC restorations showed a superior preventive effect against secondary caries compared to amalgam restorations, and a similar preventive effect against secondary caries compared to resin-composite restorations in both primary and permanent teeth. [PROSPERO Registration ID: CRD42022380959].
Topics: Humans; Dental Restoration, Permanent; Glass Ionomer Cements; Dental Caries Susceptibility; Dental Caries; Composite Resins; Dental Amalgam
PubMed: 37838608
DOI: 10.1016/j.dental.2023.10.008 -
Journal of Applied Oral Science :... 2023The use of a fiber glass post (FGP) type and choice of FGP diameter to restore endodontically treated incisors without ferrule is controversial. This study evaluated...
OBJECTIVE
The use of a fiber glass post (FGP) type and choice of FGP diameter to restore endodontically treated incisors without ferrule is controversial. This study evaluated survival rate and failure mode of severely compromised central incisors without ferrule rehabilitated using resin-based composite (RBC) with or without FGP with different diameters.
METHODOLOGY
A total of 60 decoronated bovine incisors without a ferrule were endodontically treated and prepared for 1.4, 1.6, and 1.8 mm diameter FGPs (Whitepost System DC 0.5, Fit 0.4, and DCE 0.5; FGM). Half of the teeth received FGPs cemented using dual-cure resin cement (Allcem Core; FGM), the other half were filled using only bulk-fill RBC (OPUS Bulk Fill; FGM). The crowns were directly restored with RBC. The roots were embedded in polystyrene resin and the periodontal ligament was simulated with polyether impression material. Fatigue testing was conducted under 5 Hz cyclic loading at 30 degrees to the incisal edge, beginning at 50 N (5,000 cycles) as a warmup. After, the load was increased 100 N every 15,000 cycles until fracture occurred. All specimens were subjected to transillumination, micro-CT analysis, and digital radiography before and after fatigue testing. Fracture mode was classified according to severity and repair potential. Data were analyzed with Kaplan-Meier survival test and post hoc log-rank test (α=0.05) for pairwise comparisons.
RESULTS
Using FGP significantly increased the number of cycles to failure, irrespective of FGP diameters (p=0.001). The FGP diameters had no statistically significant effect on cycles to failure or failure mode.
CONCLUSION
Using FGP without ferrule improved survival rate of structurally severely compromised central incisors compared with rehabilitation without FGP. The diameter of the FGPs had no effect on the survival rate and failure mode.
Topics: Animals; Cattle; Post and Core Technique; Composite Resins; Tooth, Nonvital; Crowns; Dental Materials; Glass; Dental Stress Analysis; Tooth Fractures; Dental Restoration Failure
PubMed: 37909530
DOI: 10.1590/1678-7757-2023-0241 -
Acta Stomatologica Croatica Sep 2023To compare short-term release of fluoride ions from ion-releasing dental restorative materials.
OBJECTIVE
To compare short-term release of fluoride ions from ion-releasing dental restorative materials.
MATERIAL AND METHODS
Seven experimental groups were prepared using the following six different materials: alkasite (Cention Forte), resin-modified glass ionomer cement (Fuji II LC), bioactive composite (ACTIVA BioACTIVE-RESTORATIVE), fluoride-containing nano-hybrid composite (Luminos UN), coat-free glass hybrid (EQUIA Forte HT), coat-applied glass hybrid (EQUIA Forte HT), and glass ionomer cement (Fuji IX). A total of 40 samples for each group (n=40) were prepared in Teflon molds (8 mm x 2 mm) and placed in polyethylene vials with 5 ml of deionized water. Fluoride release was measured after 6, 24, 48 hours, and for 5 weeks using an ion-selective electrode. The results were expressed in mg/l and the data were statistically analyzed using ANOVA.
RESULTS
Significant differences in fluoride release were observed within the first 6 hours (ANOVA p<0.001). EQUIA Forte HT had the highest release, while the other materials showed no significant differences. After 24 hours, EQUIA Forte HT (p<0.001) and Luminos UN (p<0.05) exhibited significantly higher releases, compared to other tested materials. EQUIA Forte HT maintained the highest release at 48 hours (p<0.001), followed by Cention Forte (p<0.05) and Luminos UN (p<0.05). All material pairs showed significant differences in fluoride release at 5 weeks (p<0.001).
CONCLUSION
Coat-free EQUIA Forte HT had the overall highest fluoride release, while Cention Forte demonstrated the greatest increase over time. ACTIVA BioACTIVE-RESTORATIVE exhibited the lowest fluoride release in this study.
PubMed: 37808411
DOI: 10.15644/asc57/3/3 -
PloS One 2023The purpose of this study was to assess the effectiveness and practicality of erbium lasers in the removal of ceramic restorations and appliances from natural teeth and...
BACKGROUND
The purpose of this study was to assess the effectiveness and practicality of erbium lasers in the removal of ceramic restorations and appliances from natural teeth and dental implant abutments in clinical practice.
METHODS
A retrospective analysis was conducted, involving 29 clinical cases with a total of 52 abutments requiring the removal of various ceramic restorations. The analysis evaluated the clinical procedures performed, including the type and material of the prosthetic, the type of cement used, laser setting parameters, retrieval time, and retrieval success.
RESULTS
Out of the 52 abutments, 50 were successfully retrieved without causing any damage (>95%) using either an Er,Cr:YSGG laser (N = 6) or an Er:YAG laser (N = 46). In one case, a crown was partially sectioned to prevent any negative impact of laser irradiation on the adhesive strength between the post and tooth, and in another case, a fracture occurred during debonding. The restorations consisted of 13 lithium disilicate and 39 zirconia units, including six veneers, 38 single crowns, and three fixed partial dentures (FPDs). The retrieval time varied depending on the restoration type, material thickness, cement type, retention form/fitting of the abutment and restoration, ranging from 2.25 ±0.61 minutes for veneers, 6.89 ±8.07 minutes for crowns, to 25 ±10 minutes per abutment for FPDs. Removal of a zirconia crown required more time, 7.12±8.91 minutes, compared to a lithium disilicate crown, 5.86 ±2.41 minutes. The debonding time was influenced by the laser settings as well as materials and types of prosthesis.
CONCLUSIONS
Erbium lasers present a safe and effective alternative to invasive methods for removing ceramic restorations, without causing harm to the abutment or prosthesis. Laser-assisted debonding allows for recementation of the restorations during the same appointment, making it a conservative and viable option for ceramic crown retrieval in clinical settings.
Topics: Lasers, Solid-State; Erbium; Retrospective Studies; Crowns; Zirconium; Dental Porcelain; Ceramics; Dental Restoration Failure; Materials Testing
PubMed: 38096248
DOI: 10.1371/journal.pone.0295957 -
BMC Oral Health Nov 2023To evaluate the effect of zirconia priming with MDP-Salt before MDP containing primers and self-adhesive cement on the shear bond strength.
PURPOSE
To evaluate the effect of zirconia priming with MDP-Salt before MDP containing primers and self-adhesive cement on the shear bond strength.
MATERIALS AND METHODS
Fully sintered high translucent zirconia specimens (n = 120) were assigned into 2 groups (n = 60 each): Control (No Pretreatment) and Methacryloyloxydecyl dihydrogen phosphate salt (MDP-Salt) pretreated. Each group was divided into 3 subgroups (n = 20) according to cementation protocol: 1) MDP + Silane primer and conventional resin cement, 2) MDP+ Bisphenyl dimethacrylate (BPDM) primer and conventional resin cement, and 3) MDP containing self-adhesive resin cement. Shear bond strength (SBS) was measured after 10,000 thermocycling. Contact angle was measured for tested groups. Surface topography was assessed using a 3D confocal laser scanning microscope (CLSM). Weibull analysis was performed for SBS and one-way ANOVA for contact angle and surface topography measurements (α = 0.05).
RESULTS
The use of MDP-Salt significantly improved the SBS (p < .05) for all tested subgroups. Self-adhesive cement showed an insignificant difference with MDP + Silane group for both groups (p > .05). MDP + BPDM showed a significantly lower characteristic strength compared to self-adhesive resin cement when both were pretreated with MDP-Salt. No difference between all tested groups in the surface topographic measurements while MDP-Salt showed the highest contact angle.
CONCLUSION
MDP-Salt pretreatment can improve bonding performance between zirconia and MDP containing products.
Topics: Humans; Resin Cements; Cementation; Dental Cements; Salts; Dental Bonding; Silanes; Methacrylates; Shear Strength; Materials Testing; Surface Properties; Dental Stress Analysis
PubMed: 37993834
DOI: 10.1186/s12903-023-03663-y -
International Journal of Molecular... Jul 2023The creation of buffer (hybrid) layers that provide improved adhesion to two heterogeneous materials is a promising and high-priority research area in the field of...
A Study of the Peculiarities of the Formation of a Hybrid Interface Based on Polydopamine between Dental Tissues and Dental Composites, Using IR and Raman Microspectroscopy, at the Submicron Level.
The creation of buffer (hybrid) layers that provide improved adhesion to two heterogeneous materials is a promising and high-priority research area in the field of dental materials science. In our work, using FTIR and Raman microspectroscopy at the submicron level in a system of dental composites/intact dental enamel, we assessed the molecular features of formation and chemically visualized the hybrid interface formed on the basis of a nature-like adhesive, polydopamine (PDA). It is shown that a homogeneous bioinspired PDA-hybrid interface with an increased content of O-Ca-O bonds can be created using traditional methods of dental tissue pretreatment (diamond micro drilling, acid etching), as well as the subsequent alkalinization procedure and the developed synthesis technology. The development of the proposed technology for accelerated deposition of PDA-hybrid layers, as well as the creation of self-assembled biomimetic nanocomposites with antibacterial properties, may in the future find clinical application for minimally invasive dental restoration procedures.
Topics: Composite Resins; Resin Cements; Surface Properties; Indoles; Dental Bonding; Materials Testing
PubMed: 37511394
DOI: 10.3390/ijms241411636 -
Dental Materials Journal Aug 2023To improve the cytocompatibility of mineral trioxide aggregate (MTA) cement and its ability for reparative dentin formation, the effect of adding choline dihydrogen...
To improve the cytocompatibility of mineral trioxide aggregate (MTA) cement and its ability for reparative dentin formation, the effect of adding choline dihydrogen phosphate (CDHP), which is reported to be biocompatible, to MTA cement was investigated. The L929 cell proliferation showed that the addition of CDHP improved cell viability. The addition of CDHP shortened the setting time of MTA cement, with a significant decrease in consistency above 0.4 g/mL. Diametral tensile strength of the set cement was improved by the addition of 0.4 g/mL CDHP. Solubility was judged to be within the range of clinical application. The spontaneous precipitation of low crystalline hydroxyapatite was examined by immersing the set cement in phosphate buffer saline, and it was found that the ability of the cement with 0.4 g/mL of CDHP was significantly improved compared with that of the cement without CDHP.
Topics: Materials Testing; Root Canal Filling Materials; Calcium Compounds; Oxides; Dental Cements; Silicates; Glass Ionomer Cements; Aluminum Compounds; Drug Combinations; Phosphates; Choline
PubMed: 37121734
DOI: 10.4012/dmj.2022-283 -
Journal of Clinical and Experimental... Aug 2023Failures in glass fiber post (GFP) retention may be associated with low adhesion achieved in root dentin.
BACKGROUND
Failures in glass fiber post (GFP) retention may be associated with low adhesion achieved in root dentin.
MATERIAL AND METHODS
55 single-rooted premolars were endodontically treated and distributed according to different adhesion strategies (n=11): G1: RelyX ARC (3M ESPE; etch-rinse strategy); G2: Relyx Ultimate (3M ESPE; etch-rinse strategy); G3: AllCem (FGM; etch-rinse strategy); G4: Relyx Ultimate (3M ESPE; self-etching strategy); G5: RelyX U200 (3M ESPE; self-adhesive strategy). For Bonding Strength (BS) analysis, the roots were sectioned in slices (1.0mm thickness) corresponding to each root third and submitted to push-out test. The type of failure was assessed by scanning electron microscopy (SEM).
RESULTS
The highest BS averages were found in G2 and G3. However, in the middle and apical root thirds, G3 showed statistically similar results to G4 and G5. In the cervical and middle third, G1 was statistically similar to G4 and G5. The mixed type of failure was the most common in all groups.
CONCLUSIONS
Self-etching (G4) and self-adhesive resin (G5) cements, showed similar BS results of immediate bonding in the cementation of GFP compared to conventional resin cements (G1, G2, G3). Dental Cements, Dentin-Bonding Agents, Post and Core Technique, Dental Bonding.
PubMed: 37674597
DOI: 10.4317/jced.60452 -
The Journal of Prosthetic Dentistry May 2024The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood. (Review)
Review
STATEMENT OF PROBLEM
The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood.
PURPOSE
The purpose of this scoping review was to summarize the current CAM systems, parameters, and setting changes, and their effects on different outcomes of milled indirect restorations and aspects related to their manufacture.
MATERIAL AND METHODS
The protocol of this review is available online (https://osf.io/x28ps/). Studies that used at least 2 different parameters (CAM units, number of axes, digital spacers, or protocols with different rotatory instruments, grit-sizes, milling speed, or others) for milling indirect restorations were included. A structured search up to July 2023 was performed by 2 independent reviewers for articles written in English in LILACS, MEDLINE via PubMed, EMBASE, Web of Science, and Scopus.
RESULTS
Of 1546 studies identified, 22 were included in the review. Discrepancies were found between the planned and actual measured cement space, with a decreasing linear relationship impacting restoration adaptation at different points. The CEREC MC XL milling machine was the most used system in the included studies, with variations in bur types, milling modes, and number of burs uses affecting internal fit and surface trueness. The results demonstrated the better adaptation of restorations made with 5-axis over 3-axis milling machines. Lithium disilicate and zirconia were the most commonly used materials, and crowns and inlays were popular designs. Marginal and internal adaptation were the primary outcomes assessed using the various techniques.
CONCLUSIONS
The study presented a comprehensive exploration of CAM systems and parameters, and their influence on indirect restorations. The planned cement space was not properly reproduced by the milling. Bur characteristics can affect restoration fit and trueness. The 5-axis units seem to result in better-adapted restorations compared with 3- and 4-axis units.
Topics: Computer-Aided Design; Humans; Dental Prosthesis Design; Dental Restoration, Permanent; Dental Marginal Adaptation
PubMed: 38480018
DOI: 10.1016/j.prosdent.2024.02.021 -
PloS One 2023To separate the crown from the titanium base abutment, by using heat, caused oxidization of the titanium base abutment. The effect of this procedure on the retention of...
STATEMENT OF PROBLEM
To separate the crown from the titanium base abutment, by using heat, caused oxidization of the titanium base abutment. The effect of this procedure on the retention of a crown is unclear.
PURPOSE
To compare the resin bond strength and failure type between zirconia crowns and titanium base abutments utilizing four different surface treatments. Surface roughness and morphology of each surface treatment were also investigated.
MATERIAL AND METHODS
Forty titanium base abutments (Variobase®) were divided into four groups, 1. Control, 2. Air abraded, 3. Oxidized, and 4. Oxidized-air abraded. Oxidized and oxidized-air abraded groups were debonded from zirconia crowns using constant dry heat at 500 ˚C. For air abraded and oxidized-air abraded groups (after oxidization), the titanium base abutments were air abraded with Al3O2. After cleaning, one specimen of each group was investigated under a non-contact profilometer (50x), then the same samples were investigated under SEM at 25,300,500,1000 magnification and EDS at 30kV of accelerated voltage. All specimens were then cemented (RelyX Ultimate). After aging, with thermocycling under 5C° to 55C°,120 seconds dwell time for 5,000 cycles, bond strength was tested and statistical differences were calculated with One-way ANOVA (p-value <0.05) follow by Tukey test. All separated crowns and titanium base abutments were investigated under a light microscope (20x), using fisher's exact test for correlation of the failure types.
RESULTS
There was a significant difference in the mean value of tensile bond strength among the control and test groups. Comparisons between control(237.6±46.3N) and oxidized(241.7±46.3N) showed statistically different values from air abraded(372.9±113.2N) when assembled using different surface treatments of the titanium-based abutments. (p-value<0.005) As for failure type, there were statistically significant differences between control versus air abraded, control versus oxidized-air abraded, oxidized versus air abraded, and oxidized versus oxidized-air abraded. (p-value<0.001) The titanium surface morphology shown from the profilometer and SEM was coordinated. Control (Ra 333.8nm) and oxidized (Ra 321.0nm) groups surfaces showed smooth, corrugated surfaces, meanwhile air abraded (Ra 476.0nm) and oxidized-air abraded (Ra 423.8nm) groups showed rough, rugged surfaces.
CONCLUSION
Heat oxidization of titanium-based abutments did not adversely affect tensile bond strength or the failure mode and surface roughness between titanium base abutments and zirconia crowns. However, air abrasion of the titanium surface increased surface roughness and retentive strength.
CLINICAL IMPLICATIONS
The titanium base abutments that were oxidized under heat treatment did not have an effect on crown retention. Thoroughly air abraded the titanium abutment prior to cementation can increase cement bond strength.
Topics: Titanium; Materials Testing; Resin Cements; Zirconium; Dental Abutments; Dental Stress Analysis
PubMed: 37878631
DOI: 10.1371/journal.pone.0287108