Annals of Clinical and Translational... Aug 2023Duchenne muscular dystrophy (DMD) is an X-linked disorder resulting in progressive muscle weakness and atrophy, cardiomyopathy, and in late stages, cardiorespiratory...
OBJECTIVE
Duchenne muscular dystrophy (DMD) is an X-linked disorder resulting in progressive muscle weakness and atrophy, cardiomyopathy, and in late stages, cardiorespiratory impairment, and death. As treatments for DMD have expanded, a DMD newborn screening (NBS) pilot study was conducted in New York State to evaluate the feasibility and benefit of NBS for DMD and to provide an early pre-symptomatic diagnosis.
METHODS
At participating hospitals, newborns were recruited to the pilot study, and consent was obtained to screen the newborn for DMD. The first-tier screen measured creatine kinase-MM (CK-MM) in dried blood spot specimens submitted for routine NBS. Newborns with elevated CK-MM were referred for genetic counseling and genetic testing. The latter included deletion/duplication analysis and next-generation sequencing (NGS) of the DMD gene followed by NGS for a panel of neuromuscular conditions if no pathogenic variants were detected in the DMD gene.
RESULTS
In the two-year pilot study, 36,781 newborns were screened with CK-MM. Forty-two newborns (25 male and 17 female) were screen positive and referred for genetic testing. Deletions or duplications in the DMD gene were detected in four male infants consistent with DMD or Becker muscular dystrophy. One female DMD carrier was identified.
INTERPRETATION
This study demonstrated that the state NBS program infrastructure and screening technologies we used are feasible to perform NBS for DMD. With an increasing number of treatment options, the clinical utility of early identification for affected newborns and their families lends support for NBS for this severe disease.
Topics: Infant; Humans; Male; Infant, Newborn; Female; Muscular Dystrophy, Duchenne; Neonatal Screening; Pilot Projects; Genetic Testing; High-Throughput Nucleotide Sequencing
PubMed: 37350320
DOI: 10.1002/acn3.51829 -
Journal of Exposure Science &... Sep 2023Pediatric thyroid diseases have been increasing in recent years. Environmental risk factors such as exposures to chemical contaminants may play a role but are largely...
BACKGROUND
Pediatric thyroid diseases have been increasing in recent years. Environmental risk factors such as exposures to chemical contaminants may play a role but are largely unexplored. Archived neonatal dried blood spots (DBS) offer an innovative approach to investigate environmental exposures and effects.
OBJECTIVE
In this pilot study, we applied a new method for quantifying per- and polyfluoroalkyl substances (PFAS) to 18 archived DBS from babies born in California from 1985-2018 and acquired thyroid hormone measurements from newborn screening tests. Leveraging these novel data, we evaluated (1) changes in the concentrations of eight PFAS over time and (2) the relationship between PFAS concentrations, thyroid hormone concentrations, and neonatal characteristics to inform future research.
METHODS
PFAS concentrations in DBS were measured using ultra-high-performance liquid chromatography-mass spectrometry. Summary statistics and non-parametric Wilcoxon rank-sum and Kruskal-Wallis tests were used to evaluate temporal changes in PFAS concentrations and relationships between PFAS concentrations, thyroid hormone concentrations, and neonatal characteristics.
RESULTS
The concentration and detection frequencies of several PFAS (PFOA, PFOS, and PFOSA) declined over the assessment period. We observed that the timing of specimen collection in hours after birth was related to thyroid hormone but not PFAS concentrations, and that thyroid hormones were related to some PFAS concentrations (PFOA and PFOS).
IMPACT STATEMENT
This pilot study examines the relationship between concentrations of eight per- and polyfluoroalkyl substances (PFAS), thyroid hormone levels, and neonatal characteristics in newborn dried blood spots (DBS) collected over a period of 33 years. To our knowledge, 6 of the 22 PFAS we attempted to measure have not been quantified previously in neonatal DBS, and this is the first study to examine both PFAS and thyroid hormone concentrations using DBS. This research demonstrates the feasibility of using newborn DBS for quantifying PFAS exposures in population-based studies, highlights methodological considerations in the use of thyroid hormone data for future studies using newborn DBS, and indicates potential relationships between PFAS concentrations and thyroid hormones for follow-up in future research.
Topics: Infant, Newborn; Humans; Child; Pilot Projects; Environmental Pollutants; Thyroid Hormones; Environmental Exposure; Fluorocarbons; Alkanesulfonic Acids
PubMed: 37730931
DOI: 10.1038/s41370-023-00603-4 -
Journal of Pharmacological and... 2023Pharmacokinetic/pharmacodynamic modelling has emerged as a valuable technique for understanding drug exposure and response relationships in drug development....
INTRODUCTION
Pharmacokinetic/pharmacodynamic modelling has emerged as a valuable technique for understanding drug exposure and response relationships in drug development. Pharmacokinetic data are often obtained by taking multiple blood samples, which may disturb physiological parameters and complicate study designs. Wearable automatic blood sampling systems can improve this limitation by collecting dried blood samples at programmable time points without disrupting cardiovascular parameters. It is the objective of this study to evaluate the bioanalysis of DBS in comparison to conventional blood sampling techniques and to optimize the recovery of various compounds spiked into canine blood dried on filter paper tape.
METHODS
Incubated blood samples from Beagle dogs were spiked with 16 different compounds and half of the whole blood sample was centrifuged to obtain plasma. After the dried blood sample drops were dried, liquid chromatography-mass spectrometry methods were used to analyze the samples. The study explored different anticoagulants, sample preparation methods and technical approaches to best determine the compound concentrations in dried blood samples.
RESULTS
With the two anticoagulants tested and using the optimized sample preparation methods and technical approaches we employed, the bioanalysis of dried blood samples can provide equivalent results to conventional blood sampling techniques.
DISCUSSION
Automated blood sampling systems have the potential to provide increased numbers of blood samples, providing substantially more Pharmacokinetic data within safety pharmacology studies without disrupting physiological parameters. They can provide a viable alternative to traditional methods of obtaining blood for various other types of studies or analyses.
Topics: Animals; Dogs; Tandem Mass Spectrometry; Chromatography, Liquid; Blood Specimen Collection; Plasma; Anticoagulants
PubMed: 37482323
DOI: 10.1016/j.vascn.2023.107296 -
Clinical Biochemistry Jul 2023Dried blood spot (DBS) sampling is a minimally invasive method for specimen collection with potential multifaceted uses, particularly for serosurveillance of previous...
INTRODUCTION
Dried blood spot (DBS) sampling is a minimally invasive method for specimen collection with potential multifaceted uses, particularly for serosurveillance of previous SARS-CoV-2 infection. In this study, we assessed DBS as a potential specimen type for assessing IgG and total (including IgG and IgM) antibodies to SARS-CoV-2 in vaccinated and naturally infected patients.
METHODS
Six candidate buffers were assessed for eluting blood from DBS cards. The study utilized one hundred and five paired plasma specimens and DBS specimens from prospectively collected SARS-CoV-2 vaccinated individuals, remnants from those with PCR confirmed SARS-CoV-2 infections, or remnants from those without history of infection or vaccination. All specimens were tested with the Siemens SARS-CoV-2 total assay (COV2T) or IgG assay (sCOVG).
RESULTS
The lowest backgrounds were observed with water and PBS, and water was used for elution. Relative to plasma samples, DBS samples had a positive percent agreement (PPA) of 94.4% (95% CI: 94.9-100%) for COV2T and 79.2 (68.4-87.0) for sCOVG using the manufacturer's cutoff. The NPA was 100 % (87.1-100.0 and 85.13-100) for both assays. Dilution studies revealed 100% (95% CI: 90.8-100%) qualitative agreement between specimen types on the COV2T assay and 98.0% (88.0-99.9%) with the sCOVG using study defined cutoffs.
CONCLUSION
DBS specimens demonstrated high PPA and NPA relative to plasma for SARS-CoV-2 serological testing. Our data support feasibility of DBS sampling for SARS-CoV-2 serological testing.
Topics: Humans; COVID-19; SARS-CoV-2; COVID-19 Testing; Specimen Handling; Antibodies, Viral; Immunoglobulin M; Immunoglobulin G; Dried Blood Spot Testing
PubMed: 34990593
DOI: 10.1016/j.clinbiochem.2021.12.012 -
Scientific Reports Dec 2023Future lunar exploration will be based on in-situ resource utilization (ISRU) techniques. The most abundant raw material on the Moon is lunar regolith, which, however,...
Future lunar exploration will be based on in-situ resource utilization (ISRU) techniques. The most abundant raw material on the Moon is lunar regolith, which, however, is very scarce on Earth, making the study of simulants a necessity. The objective of this study is to characterize and investigate the sintering behavior of EAC-1A lunar regolith simulant. The characterization of the simulant included the determination of the phase assemblage, characteristic temperatures determination and water content analysis. The results are discussed in the context of sintering experiments of EAC-1A simulant, which showed that the material can be sintered to a relative density close to 90%, but only within a very narrow range of temperatures (20-30 °C). Sintering experiments were performed for sieved and unsieved, as well as for dried and non-dried specimens of EAC-1A. In addition, an analysis of the densification and mechanical properties of the sintered specimens was done. The sintering experiments at different temperatures showed that the finest fraction of sieved simulant can reach a higher maximum sintering temperature, and consequently a higher densification and biaxial strength. The non-dried powder exhibited higher densification and biaxial strength after sintering compared to the dried specimen. This difference was explained with a higher green density of the non-dried powder during pressing, rather than due to an actual influence on the sintering mechanism. Nevertheless, drying the powder prior to sintering is important to avoid the overestimation of the strength of specimens to be fabricated on the Moon.
PubMed: 38155314
DOI: 10.1038/s41598-023-50391-y -
Clinical Chemistry and Laboratory... Jan 2024The collection of capillary blood microsamples via finger-prick has several advantages over traditional blood collection. It is considered convenient and more... (Review)
Review
The collection of capillary blood microsamples via finger-prick has several advantages over traditional blood collection. It is considered convenient and more patient-centric, enabling collection of the sample by the patient at her/his home with subsequent analysis in the lab following postal shipment. Determination of the diabetes biomarker HbA in self-collected microsamples to remotely monitor diabetes patients seems to be a very promising option which could eventually lead to better treatment adaptations and disease control. This is especially convenient/relevant for patients living in areas where venipuncture is impractical, or to support virtual consultations using telemedicine. Over the years, a substantial numbers of reports on HbA and microsampling have been published. However, the heterogeneity of the applied study designs and data evaluation is remarkable. This review provides a general and critical overview of these papers, along with specific points of attention that should be dealt with when aiming at implementing microsampling for reliable HbA determination. We focus on the used (dried) blood microsampling techniques, collection conditions, stability of the microsamples, sample extraction, analytical methods, method validation, correlation studies with conventional venous blood samples and patient satisfaction. Lastly, the possibility of using liquid instead of dried blood microsamples is discussed. Liquid blood microsampling is expected to have similar advantages as dried blood microsampling and several studies suggest it to be a suitable approach to collect samples remotely for subsequent HbA analysis in the lab.
Topics: Humans; Female; Blood Specimen Collection; Dried Blood Spot Testing; Phlebotomy; Diabetes Mellitus
PubMed: 37419657
DOI: 10.1515/cclm-2023-0228 -
Journal of Immunological Methods Aug 2023Dried serum spots that are well prepared can be attractive alternatives to frozen serum samples for shelving specimens in a medical or research center's biobank and...
Dried serum spots that are well prepared can be attractive alternatives to frozen serum samples for shelving specimens in a medical or research center's biobank and mailing freshly prepared serum to specialized laboratories. During the pre-analytical phase, complications can arise which are often challenging to identify or are entirely overlooked. These complications can lead to reproducibility issues, which can be avoided in serum protein analysis by implementing optimized storage and transfer procedures. With a method that ensures accurate loading of filter paper discs with donor or patient serum, a gap in dried serum spot preparation and subsequent serum analysis shall be filled. Pre-punched filter paper discs with a 3 mm diameter are loaded within seconds in a highly reproducible fashion (approximately 10% standard deviation) when fully submerged in 10 μl of serum, named the "Submerge and Dry" protocol. Such prepared dried serum spots can store several hundred micrograms of proteins and other serum components. Serum-borne antigens and antibodies are reproducibly released in 20 μl elution buffer in high yields (approximately 90%). Dried serum spot-stored and eluted antigens kept their epitopes and antibodies their antigen binding abilities as was assessed by SDS-PAGE, 2D gel electrophoresis-based proteomics, and Western blot analysis, suggesting pre-punched filter paper discs as handy solution for serological tests.
Topics: Humans; Reproducibility of Results; Antibodies; Filtration; Paper
PubMed: 37419022
DOI: 10.1016/j.jim.2023.113519 -
Applications in Plant Sciences 2023Current methods for maceration of plant tissue use hazardous chemicals. The new method described here improves the safety of dissection and maceration of soft plant...
PREMISE
Current methods for maceration of plant tissue use hazardous chemicals. The new method described here improves the safety of dissection and maceration of soft plant tissues for microscopic imaging by using the harmless enzyme pectinase.
METHODS AND RESULTS
Leaf material from a variety of land plants was obtained from living plants and dried herbarium specimens. Concentrations of aqueous pectinase and soaking schedules were optimized, and tissues were manually dissected while submerged in fresh solution following a soaking period. Most leaves required 2-4 h of soaking; however, delicate leaves could be macerated after 30 min while tougher leaves required 12 h to 3 days of soaking. Staining techniques can also be used with this method, and permanent or semi-permanent slides can be prepared. The epidermis, vascular tissue, and individual cells were imaged at magnifications of 10× to 400×. Only basic safety precautions were needed.
CONCLUSIONS
This pectinase method is a cost-effective and safe way to obtain images of epidermal peels, separated tissues, or isolated cells from a wide range of plant taxa.
PubMed: 37915428
DOI: 10.1002/aps3.11543 -
Molecular Genetics & Genomic Medicine Jan 2024Pyruvate dehydrogenase complex deficiency (PDCD) is a mitochondrial neurometabolic disorder of energy deficit, with incidence of about 1 in 42,000 live births annually... (Review)
Review
BACKGROUND
Pyruvate dehydrogenase complex deficiency (PDCD) is a mitochondrial neurometabolic disorder of energy deficit, with incidence of about 1 in 42,000 live births annually in the USA. The median and mean ages of diagnosis of PDCD are about 12 and 31 months, respectively. PDCD is a major cause of primary lactic acidosis with concomitant elevation in blood alanine (Ala) and proline (Pro) concentrations depending on phenotypic severity. Alanine/Leucine (Ala/Leu) ≥4.0 and Proline/Leucine (Pro/Leu) ≥3.0 combination cutoff from dried blood spot specimens was used as a biomarker for early identification of neonates/infants with PDCD. Further investigations were needed to evaluate the sensitivity (SN), specificity (SP), and clinical utility of such amino acid (AA) ratio combination cutoffs in discriminating PDCD from other inborn errors of metabolism (IEM) for early identification of such patients.
METHODS
We reviewed medical records of patients seen at UPMC in the past 11 years with molecularly or enzymatically confirmed diagnosis. We collected plasma AA analysis data from samples prior to initiation of therapeutic interventions such as total parenteral nutrition and/or ketogenic diet. Conditions evaluated included organic acidemias, primary mitochondrial disorders (MtDs), fatty acid oxidation disorders (FAOD), other IEMs on current newborn screening panels, congenital cardiac great vessel anomalies, renal tubular acidosis, and non-IEMs. The utility of specific AA ratio combinations as biomarkers were evaluated using receiver operating characteristic curves, correlation analysis, principal component analysis, and cutoff SN, SP, and positive predictive value determined from 201 subjects with broad age range.
RESULTS
Alanine/Lysine (Ala/Lys) and Ala/Leu as well as (Ala + Pro)/(Leu + Lys) and Ala/Leu ratio combinations effectively discriminated subjects with PDCD from those with other MtDs and IEMs on current newborn screening panels. Specific AA ratio combinations were significantly more sensitive in identifying PDCD than Ala alone or combinations of Ala and/or Pro in the evaluated cohort of subjects. Ala/Lys ≥3.0 and Ala/Leu ≥5.0 as well as (Ala + Pro)/(Leu + Lys) ≥2.5 and Ala/Leu ≥5.0 combination cutoffs identified patients with PDCD with 100% SN and ~85% SP.
CONCLUSIONS
With the best predictor of survival and positive cognitive outcome in PDCD being age of diagnosis, PDCD patients would benefit from use of such highly SN and SP AA ratio combination cutoffs as biomarkers for early identification of at-risk newborns, infants, and children, for early intervention(s) with known and/or novel therapeutics for this disorder.
Topics: Child; Humans; Infant, Newborn; Infant; Child, Preschool; Amino Acids; Leucine; Pyruvate Dehydrogenase Complex Deficiency Disease; Metabolism, Inborn Errors; Alanine; Proline; Biomarkers
PubMed: 37688338
DOI: 10.1002/mgg3.2283 -
Brazilian Dental Journal 2023This study evaluated the effect of heating on the physicochemical properties and surface changes of tricalcium silicate sealers. Three tricalcium silicate root canal...
This study evaluated the effect of heating on the physicochemical properties and surface changes of tricalcium silicate sealers. Three tricalcium silicate root canal sealers (Bio-C Sealer, BioRoot-RCS, EndoSequence BC Sealer), and one epoxy resin-based sealer (AH Plus; control) were tested. The effect of heating on setting time (ST) and flowability were assessed according to ANSI/ADA 57 and ISO 6876 standards. Solubility and dimensional change (DC) of the set sealers were evaluated at 24 hours and after 30 days; the pH of the water used in the DC testing was also measured. Tests were repeated with heated sealers in an oven at 100 °C for 1 min. SEM and EDS analysis were performed. Data were analyzed using One-Way ANOVA and Tukey post-hoc tests (α=5%). Heating decreased the ST for AH Plus and EndoSequence (p<0.05). Heating reduced flowability (p<0.05) and increased pH for AH Plus (p<0.05). The solubility of Bio-C (dried specimens) was not in accordance with the ANSI/ADA standard. The solubility of EndoSequence was significantly higher (p<0.05) when it was heated and dried after 30 days. DC of Bio-C (24 h and 30 days), BioRoot-RCS (30 days) and AH Plus (24 h and 30 days) were not in accordance with the standards. SEM and EDS analysis showed significant changes in sealer microstructure after heating. In conclusion, heating decreased the ST and increased the solubility of EndoSequence BC sealer. No significant changes in flowability, DC, and pH were identified for all three tricalcium silicate sealers after heat application. However, all sealers had significant surface changes.
Topics: Root Canal Filling Materials; Heating; Dental Pulp Cavity; Calcium Compounds; Epoxy Resins; Silicates; Materials Testing
PubMed: 37909640
DOI: 10.1590/0103-6440202305237