Surgical Endoscopy Aug 2023Gastrointestinal anastomoses with classical sutures and/or metal staples have resulted in significant bleeding and leak rates. This multi-site study evaluated the...
INTRODUCTION
Gastrointestinal anastomoses with classical sutures and/or metal staples have resulted in significant bleeding and leak rates. This multi-site study evaluated the feasibility, safety, and preliminary effectiveness of a novel linear magnetic compression anastomosis device, the Magnet System (MS), to form a side-to-side duodeno-ileostomy (DI) diversion for weight loss and type 2 diabetes (T2D) resolution.
METHODS
In patients with class II and III obesity (body mass index [BMI, kg/m] ≥ 35.0- ≤ 50.0 with/without T2D [HbA1C > 6.5%]), two linear MS magnets were delivered endoscopically to the duodenum and ileum with laparoscopic assistance and aligned, initiating DI; sleeve gastrectomy (SG) was added. There were no bowel incisions or retained sutures/staples. Fused magnets were expelled naturally. Adverse events (AEs) were graded by Clavien-Dindo Classification (CDC).
RESULTS
Between November 22, 2021 and July 18, 2022, 24 patients (83.3% female, mean ± SEM weight 121.9 ± 3.3 kg, BMI 44.4 ± 0.8) in three centers underwent magnetic DI. Magnets were expelled at a median 48.5 days. Respective mean BMI, total weight loss, and excess weight loss at 6 months (n = 24): 32.0 ± 0.8, 28.1 ± 1.0%, and 66.2 ± 3.4%; at 12 months (n = 5), 29.3 ± 1.5, 34.0 ± 1.4%, and 80.2 ± 6.6%. Group mean respective mean HbA1 and glucose levels dropped to 1.1 ± 0.4% and 24.8 ± 6.6 mg/dL (6 months); 2.0 ± 1.1% and 53.8 ± 6.3 mg/dL (12 months). There were 0 device-related AEs, 3 procedure-related serious AEs. No anastomotic bleeding, leakage, stricture, or mortality.
CONCLUSION
In a multi-center study, side-to-side Magnet System duodeno-ileostomy with SG in adults with class III obesity appeared feasible, safe, and effective for weight loss and T2D resolution in the short term.
Topics: Adult; Humans; Female; Male; Magnets; Diabetes Mellitus, Type 2; Duodenum; Anastomosis, Surgical; Obesity; Gastrectomy; Weight Loss; Obesity, Morbid; Retrospective Studies; Gastric Bypass
PubMed: 37217682
DOI: 10.1007/s00464-023-10134-6 -
Nanomaterials (Basel, Switzerland) Sep 2023Magnetic topological insulators (MTIs) are a group of materials that feature topological band structures with concurrent magnetism, which can offer new opportunities for... (Review)
Review
Magnetic topological insulators (MTIs) are a group of materials that feature topological band structures with concurrent magnetism, which can offer new opportunities for technological advancements in various applications, such as spintronics and quantum computing. The combination of topology and magnetism introduces a rich spectrum of topological phases in MTIs, which can be controllably manipulated by tuning material parameters such as doping profiles, interfacial proximity effect, or external conditions such as pressure and electric field. In this paper, we first review the mainstream MTI material platforms where the quantum anomalous Hall effect can be achieved, along with other exotic topological phases in MTIs. We then focus on highlighting recent developments in modulating topological properties in MTI with finite-size limit, pressure, electric field, and magnetic proximity effect. The manipulation of topological phases in MTIs provides an exciting avenue for advancing both fundamental research and practical applications. As this field continues to develop, further investigations into the interplay between topology and magnetism in MTIs will undoubtedly pave the way for innovative breakthroughs in the fundamental understanding of topological physics as well as practical applications.
PubMed: 37836296
DOI: 10.3390/nano13192655 -
Frontiers in Neurology 2023Patients and technologists commonly describe vertigo, dizziness, and imbalance near high-field magnets, e.g., 7-Tesla (T) magnetic resonance imaging (MRI) scanners. We...
INTRODUCTION
Patients and technologists commonly describe vertigo, dizziness, and imbalance near high-field magnets, e.g., 7-Tesla (T) magnetic resonance imaging (MRI) scanners. We sought a simple way to alleviate vertigo and dizziness in high-field MRI scanners by applying the understanding of the mechanisms behind magnetic vestibular stimulation and the innate characteristics of vestibular adaptation.
METHODS
We first created a three-dimensional (3D) control systems model of the direct and indirect vestibulo-ocular reflex (VOR) pathways, including adaptation mechanisms. The goal was to develop a paradigm for human participants undergoing a 7T MRI scan to optimize the speed and acceleration of entry into and exit from the MRI bore to minimize unwanted vertigo. We then applied this paradigm from the model by recording 3D binocular eye movements (horizontal, vertical, and torsion) and the subjective experience of eight normal individuals within a 7T MRI. The independent variables were the duration of entry into and exit from the MRI bore, the time inside the MRI bore, and the magnetic field strength; the dependent variables were nystagmus slow-phase eye velocity (SPV) and the sensation of vertigo.
RESULTS
In the model, when the participant was exposed to a linearly increasing magnetic field strength, the per-peak (after entry into the MRI bore) and post-peak (after exiting the MRI bore) responses of nystagmus SPV were reduced with increasing duration of entry and exit, respectively. There was a greater effect on the per-peak response. The entry/exit duration and peak response were inversely related, and the nystagmus was decreased the most with the 5-min duration paradigm (the longest duration modeled). The experimental nystagmus pattern of the eight normal participants matched the model, with increasing entry duration having the strongest effect on the per-peak response of nystagmus SPV. Similarly, all participants described less vertigo with the longer duration entries.
CONCLUSION
Increasing the duration of entry into and exit out of a 7T MRI scanner reduced or eliminated vertigo symptoms and reduced nystagmus peak SPV. Model simulations suggest that central processes of vestibular adaptation account for these effects. Therefore, 2-min entry and 20-s exit durations are a practical solution to mitigate vertigo and other discomforting symptoms associated with undergoing 7T MRI scans. In principle, these findings also apply to different magnet strengths.
PubMed: 38046576
DOI: 10.3389/fneur.2023.1255105 -
Journal of the American Chemical Society Sep 2023Metal-free magnetism remains an enigmatic field, offering prospects for unconventional magnetic and electronic devices. In the pursuit of such magnetism, triangulenes,...
Metal-free magnetism remains an enigmatic field, offering prospects for unconventional magnetic and electronic devices. In the pursuit of such magnetism, triangulenes, endowed with inherent spin polarization, are promising candidates to serve as monomers to construct extended structures. However, controlling and enhancing the magnetic interactions between the monomers persist as a significant challenge in molecular spintronics, as so far only weak antiferromagnetic coupling through the linkage has been realized, hindering their room temperature utilization. Herein, we investigate 24 triangulene dimers using first-principles calculations and demonstrate their tunable magnetic coupling (), achieving unprecedented strong values of up to -144 meV in a non-Kekulé dimer. We further establish a positive correlation between bandgap, electronic coupling, and antiferromagnetic interaction, thereby providing molecular-level insights into enhancing magnetic interactions. By twisting the molecular fragments, we demonstrate an effective and feasible approach to control both the sign and strength of by tuning the balance between potential and kinetic exchanges. We discover that can be substantially boosted at planar configurations up to -198 meV. We realize ferromagnetic coupling in nitrogen-doped triangulene dimers at both planar and largely twisted configurations, representing the first example of ferromagnetic triangulene dimers that cannot be predicted by the Ovchinnikov rule. This work thus provides a practical strategy for augmenting magnetic coupling and open up new avenues for metal-free ferromagnetism.
PubMed: 37610306
DOI: 10.1021/jacs.3c05178 -
Nature Communications May 2024The chiral antiferromagnetic (AFM) materials, which have been widely investigated due to their rich physics, such as non-zero Berry phase and topology, provide a...
The chiral antiferromagnetic (AFM) materials, which have been widely investigated due to their rich physics, such as non-zero Berry phase and topology, provide a platform for the development of antiferromagnetic spintronics. Here, we find two distinctive anomalous Hall effect (AHE) contributions in the chiral AFM MnPt, originating from a time-reversal symmetry breaking induced intrinsic mechanism and a skew scattering induced topological AHE due to an out-of-plane spin canting with respect to the Kagome plane. We propose a universal AHE scaling law to explain the AHE resistivity ( ) in this chiral magnet, with both a scalar spin chirality (SSC)-induced skew scattering topological AHE term, and non-collinear spin-texture induced intrinsic anomalous Hall term, . We found that and can be effectively modulated by the interfacial electron scattering, exhibiting a linear relation with the inverse film thickness. Moreover, the scaling law can explain the anomalous Hall effect in various chiral magnets and has far-reaching implications for chiral-based spintronics devices.
PubMed: 38697983
DOI: 10.1038/s41467-024-46325-5 -
Nano Letters May 2024Recent advances in single-particle photothermal circular dichroism (PT CD) and photothermal magnetic circular dichroism (PT MCD) microscopy have shown strong promise for... (Review)
Review
Recent advances in single-particle photothermal circular dichroism (PT CD) and photothermal magnetic circular dichroism (PT MCD) microscopy have shown strong promise for diverse applications in chirality and magnetism. Photothermal circular dichroism microscopy measures direct differential absorption of left- and right-circularly polarized light by a chiral nanoobject and thus can measure a pure circular dichroism signal, which is free from the contribution of circular birefringence and linear dichroism. Photothermal magnetic circular dichroism, which is based on the polar magneto-optical Kerr effect, can probe the magnetic properties of a single nanoparticle (of sizes down to 20 nm) optically. Single-particle measurements enable studies of the spatiotemporal heterogeneity of magnetism at the nanoscale. Both PT CD and PT MCD have already found applications in chiral plasmonics and magnetic nanomaterials. Most importantly, the advent of these microscopic techniques opens possibilities for many novel applications in biology and nanomaterial science.
PubMed: 38578845
DOI: 10.1021/acs.nanolett.4c00448 -
Analytical Biochemistry Jul 2023Exosomes are potential biomarkers for disease diagnosis and treatment, as well as drug carriers. However, as their isolation and detection remain critical issues,...
Exosomes are potential biomarkers for disease diagnosis and treatment, as well as drug carriers. However, as their isolation and detection remain critical issues, convenient, rapid, low-cost, and effective methods are necessary. In this study, we present a rapid and simple method for directly capturing and analyzing exosomes from complex cell culture media using CaTiO:Eu@FeO multifunctional nanocomposites. The CaTiO:Eu@FeO nanocomposites were prepared by high-energy ball-milling and used to isolate exosomes by binding CaTiO:Eu@FeO nanocomposites and the hydrophilic phosphate head of the exosome phospholipids. Notably, the developed CaTiO:Eu@FeO multifunctional nanocomposites achieved results comparable with those of commercially available TiO and were separated using a magnet within 10 min. Moreover, we report a surface-enhanced Raman scattering (SERS)-based immunoassay for detecting the exosome biomarker CD81. Gold nanorods (Au NRs) were modified with detection antibodies, and antibody-conjugated Au NRs were labeled with 3, 3, diethylthiatricarbocyanine iodide (DTTC) as the SERS tags. A method combining magnetic separation and SERS was developed to detect exosomal biomarker CD81. The results of this study demonstrate the feasibility of this new technique as a useful tool for exosome isolation and detection.
Topics: Exosomes; Nanocomposites; Gold; Spectrum Analysis, Raman; Magnetics
PubMed: 37201773
DOI: 10.1016/j.ab.2023.115161 -
Scientific Reports Jun 2024We introduce magnetophoresis-based microfluidics for sorting biological targets using positive Magnetophoresis (pM) for magnetically labeled particles and negative...
We introduce magnetophoresis-based microfluidics for sorting biological targets using positive Magnetophoresis (pM) for magnetically labeled particles and negative Magnetophoresis (nM) for label-free particles. A single, externally magnetized ferromagnetic wire induces repulsive forces and is positioned across the focused sample flow near the main channel's closed end. We analyze magnetic attributes and separation performance under two transverse dual-mode magnetic configurations, examining magnetic fields, hydrodynamics, and forces on microparticles of varying sizes and properties. In pM, the dual-magnet arrangement (DMA) for sorting three distinct particles shows higher magnetic gradient generation and throughput than the single-magnet arrangement (SMA). In nM, the numerical results for SMA sorting of red blood cells (RBCs), white blood cells (WBCs), and prostate cancer cells (PC3-9) demonstrate superior magnetic properties and throughput compared to DMA. Magnetized wire linear movement is a key design parameter, allowing device customization. An automated device for handling more targets can be created by manipulating magnetophoretic repulsion forces. The transverse wire and magnet arrangement accommodate increased channel depth without sacrificing efficiency, yielding higher throughput than other devices. Experimental validation using soft lithography and 3D printing confirms successful sorting and separation, aligning well with numerical results. This demonstrates the successful sorting and separating of injected particles within a hydrodynamically focused sample in all systems. Both numerical and experimental findings indicate a separation accuracy of 100% across various Reynolds numbers. The primary channel dimensions measure 100 µm in height and 200 µm in width. N52 permanent magnets were employed in both numerical simulations and experiments. For numerical simulations, a remanent flux density of 1.48 T was utilized. In the experimental setup, magnets measuring 0.5 × 0.5 × 0.125 inches and 0.5 × 0.5 × 1 inch were employed. The experimental data confirm the device's capability to achieve 100% separation accuracy at a Reynolds number of 3. However, this study did not explore the potential impact of increased flow rates on separation accuracy.
Topics: Humans; Microfluidic Analytical Techniques; Cell Separation; Erythrocytes; Microfluidics; Leukocytes; Hydrodynamics; Cell Line, Tumor
PubMed: 38858424
DOI: 10.1038/s41598-024-64330-y -
Scientific Reports Oct 2023Magnetic motion control has been actively studied mainly for the purpose of biomedical applications. However, in many cases, many actuator magnets surround a small...
Magnetic motion control has been actively studied mainly for the purpose of biomedical applications. However, in many cases, many actuator magnets surround a small magnet to be moved, and they consume large electric power. In some cases, complex calculations are required to estimate the control input of the actuator magnets. This study proposes a simple method to move a small magnet to the desired positions. For this, three cylindrical permanent magnets magnetized in the radial direction were positioned as the sides of a triangle; these actuator magnets were rotated using motors. By monitoring the position of the small magnet and through simple feedback control based on the angles of the three actuator magnets, the untethered small magnet could be moved along arbitrary three-dimensional (3D) paths. The control principle was established by calculating the magnetic force and torque acting on the small magnet for some sets of actuator-magnet angles.
PubMed: 37872282
DOI: 10.1038/s41598-023-45419-2 -
Advanced Science (Weinheim,... Sep 2023Limbless crawling on land requires breaking symmetry of the friction with the ground and exploiting an actuation mechanism to generate propulsive forces. Here, kirigami...
Limbless crawling on land requires breaking symmetry of the friction with the ground and exploiting an actuation mechanism to generate propulsive forces. Here, kirigami cuts are introduced into a soft magnetic sheet that allow to achieve effective crawling of untethered soft robots upon application of a rotating magnetic field. Bidirectional locomotion is achieved under clockwise and counterclockwise rotating magnetic fields with distinct locomotion patterns and crawling speed in forward and backward propulsions. The crawling and deformation profiles of the robot are experimentally characterized and combined with detailed multiphysics numerical simulations to extract locomotion mechanisms in both directions. It is shown that by changing the shape of the cuts and orientation of the magnet the robot can be steered, and if combined with translational motion of the magnet, complex crawling paths are programed. The proposed magnetic kirigami robot offers a simple approach to developing untethered soft robots with programmable motion.
PubMed: 37357135
DOI: 10.1002/advs.202301895