Yakugaku Zasshi : Journal of the... 2024Inspired by the mechanism by which microorganisms utilize siderophores to ingest iron, four different Fe complexes of typical artificial siderophore ligands containing... (Review)
Review
Inspired by the mechanism by which microorganisms utilize siderophores to ingest iron, four different Fe complexes of typical artificial siderophore ligands containing catecholate and/or hydroxamate groups, K[Fe-L], K[Fe-L], K[Fe-L], and [Fe-L], were prepared. They were modified on an Au substrate surface (Fe-L/Au) and applied as microorganism immobilization devices for fast, sensitive, selective detection of microorganisms, where HL, HL, HL, and HL denote the tri-catecholate, biscatecholate-monohydroxamate, monocatecholate-bishydroxamate, and tri-hydroxamate type of artificial siderophores, respectively. Their adsorption properties for the several microorganisms were investigated using scanning electron microscopy (SEM), quartz crystal microbalance (QCM), and electric impedance spectroscopy (EIS) methods. The artificial siderophore-iron complexes modified on the Au substrates Fe-L/Au, Fe-L/Au, Fe-L/Au, and Fe-L/Au showed specific microorganism immobilization behavior with selectivity based on the structure of the artificial siderophores. Their specificities corresponded well with the structural characteristics of natural siderophores that microorganisms release from the cell and/or use to take up an iron. These findings suggest that release and uptake are achieved through specific interactions between the artificial siderophore-Fe complexes and receptors on the cell surfaces of microorganisms. This study revealed that Fe-L/Au systems have specific potential to serve as effective immobilization probes of microorganisms for rapid, selective detection and identification of a variety of microorganisms.
Topics: Siderophores; Gold; Iron; Adsorption; Cells, Immobilized; Quartz Crystal Microbalance Techniques; Microscopy, Electron, Scanning; Ligands; Catechols; Hydroxamic Acids
PubMed: 38825473
DOI: 10.1248/yakushi.23-00197-3 -
Journal of Physical Therapy Science Jul 2023[Purpose] This study aimed to evaluate the reliability and validity of measuring the range of motion of joints using a remote videoconferencing system (Zoom) and a...
[Purpose] This study aimed to evaluate the reliability and validity of measuring the range of motion of joints using a remote videoconferencing system (Zoom) and a smartphone application. [Participants and Methods] This study included 16 young and healthy adults. The participants were instructed to perform shoulder joint flexion exercises in a seated position, with automatic motions, and maintain that posture throughout the measurement. Two measurements were performed: 1) angle measurement using a three-dimensional (3D) motion analyzer, and 2) angle measurement using the videoconference software, Zoom, and a smartphone application. Intra- and inter-rater reliabilities were calculated using the intraclass correlation coefficients (ICC). The degree of agreement between the representative values of each measurer and the 3D motion analyzer was examined. [Results] ICC (1, 1) for intra-examiner reliability were 0.912 and 0.996. For the inter-rater reliability, the ICC (2, 1) was 0.945. The correlation coefficient between each examiner's value and the value of the 3D motion analyzer was 0.955 and 0.980, respectively. The Bland-Altman analysis results indicated no systematic error. [Conclusion] The method of remotely measuring joint range of motion using Zoom and a smartphone application demonstrated high reliability and validity.
PubMed: 37405179
DOI: 10.1589/jpts.35.538 -
Multiple Sclerosis and Related Disorders Nov 2023Fatigue is one of the most common and debilitating symptoms in people with multiple sclerosis (PwMS). Disease-modifying therapies (DMTs) are currently the gold standard... (Review)
Review
INTRODUCTION
Fatigue is one of the most common and debilitating symptoms in people with multiple sclerosis (PwMS). Disease-modifying therapies (DMTs) are currently the gold standard in the treatment of MS and their effectiveness has been assessed through randomized clinical trials (RCTs). However, there is limited evidence on the impact of DMTs on fatigue in (PwMS). We conducted a systematic review to 1) understand whether fatigue is included as an outcome in MS trials of DMTs; 2) determine the effects on fatigue of treating MS with DMTs and 3) assess the quality of MS trials including fatigue as an outcome.
METHODS
Two independent researchers systematically searched MEDLINE, EMBASE and ClinicalTrials.gov from 1993 to January 2023 for RCTs that measured fatigue as an outcome. Adherence to reporting standards was assessed with the Consolidated Standards of Reporting Trials (CONSORT)-Patient-Reported Outcomes (PRO), while the risk of bias (RoB) was assessed with the RoB 2 tool by the Cochrane Handbook for Systematic Reviews of Interventions. The systematic review protocol was registered in PROSPERO (CRD42022383321).
RESULTS
The search strategy identified 130 RCTs of DMTs of which 7 (5%) assessed fatigue as an outcome. Of the 7 trials, only two presented statistically significant results. In addition, the reporting of fatigue among RCTs was suboptimal with a mean adherence to the CONSORT-PRO Statement of 36% across all trials. Of the 7 trials included, four were assessed as 'high' RoB..
CONCLUSIONS
Fatigue has a major impact on PwMS yet there is limited trial-based evidence on the impact of DMTs on fatigue. Assessment of fatigue as an outcome is underrepresented in trials of DMTs and the reporting of PRO trial data is suboptimal. Thus, it is imperative that MS researchers conduct RCTs that include fatigue as an outcome, to support clinicians and people with MS (PwMS) to consider the impact of the different DMTs on fatigue.
Topics: Humans; Fatigue; Multiple Sclerosis; Patient Reported Outcome Measures; Reference Standards; Systematic Reviews as Topic
PubMed: 37839365
DOI: 10.1016/j.msard.2023.105065 -
Foot (Edinburgh, Scotland) Jun 2024Plantar pressure measurement systems are routinely used in sports and health applications to assess locomotion. The purpose of this review is to describe and critically... (Review)
Review Comparative Study
Plantar pressure measurement systems are routinely used in sports and health applications to assess locomotion. The purpose of this review is to describe and critically discuss: (a) applications of the pressure measurement systems in sport and healthcare, (b) testing protocols and considerations for clinical gait analysis, (c) clinical recommendations for interpreting plantar pressure data, (d) calibration procedures and their accuracy, and (e) the future of pressure sensor data analysis. Rigid pressure platforms are typically used to measure plantar pressures for the assessment of foot function during standing and walking, particularly when barefoot, and are the most accurate for measuring plantar pressures. For reliable data, two step protocol prior to contacting the pressure plate is recommended. In-shoe systems are most suitable for measuring plantar pressures in the field during daily living or dynamic sporting movements as they are often wireless and can measure multiple steps. They are the most suitable equipment to assess the effects of footwear and orthotics on plantar pressures. However, they typically have lower spatial resolution and sampling frequency than platform systems. Users of pressure measurement systems need to consider the suitability of the calibration procedures for their chosen application when selecting and using a pressure measurement system. For some applications, a bespoke calibration procedure is required to improve validity and reliability of the pressure measurement system. The testing machines that are commonly used for dynamic calibration of pressure measurement systems frequently have loading rates of less than even those found in walking, so the development of testing protocols that truly measure the loading rates found in many sporting movements are required. There is clear potential for AI techniques to assist in the analysis and interpretation of plantar pressure data to enable the more complete use of pressure system data in clinical diagnoses and monitoring.
Topics: Humans; Pressure; Foot; Gait Analysis; Shoes; Calibration; Sports
PubMed: 38579518
DOI: 10.1016/j.foot.2024.102094 -
The American Journal of Clinical... Oct 2023Body composition assessment aids evaluation of energy stores and the impact of diseases and interventions on child growth. Current United States pediatric reference... (Observational Study)
Observational Study
BACKGROUND
Body composition assessment aids evaluation of energy stores and the impact of diseases and interventions on child growth. Current United States pediatric reference ranges from the National Health and Nutrition Examination Survey (NHANES) include 20% of children with obesity, body mass index of ≥95th percentile.
OBJECTIVES
This study aimed to develop dual energy X-ray absorptiometry (DXA) based reference ranges in a diverse cohort with low-obesity prevalence from the Bone Mineral Density in Childhood Study (BMDCS).
METHODS
This is a secondary analysis of a longitudinal, prospective, observational cohort. Healthy children (height and BMI within 3rd to 97th percentiles, ages 5-19 y at enrollment), from 5 United States centers were measured annually for ≤7 visits. Whole body scans were acquired using Hologic scanners. A subsample underwent repeat measurements to determine precision. We generated reference ranges for appendicular and total lean soft tissue mass index (LSTM Index), fat mass index (FMI), and other body composition measures. Resulting curves were compared to NHANES and across subgroups. Sex and age-specific equations were developed to adjust body composition Z-scores for height Z score.
RESULTS
We obtained 9846 scans of 2011 participants (51% female, 22% Black, 17% Hispanic, 48% White, 7% Asian/Pacific Islander, and 6% with obesity). Precision (percent coefficient of variation) ranged from 0.7% to 1.96%. Median and-2 standard deviation curves for BMDCS and NHANES were similar, but NHANES +2 standard deviation LSTM Index and FMI curves were distinctly greater than the respective BMDCS curves. Subgroup differences were more extreme for appendicular LSTM Index-Z (mean ± SD: Asian -0.52 ± 0.93 compared with Black 0.77 ± 0.87) than for FMI-Z (Hispanic 0.29 ± 0.98 compared with Black -0.14 ± 1.1) and were smaller for Z-scores adjusted for height Z-score.
CONCLUSIONS
These reference ranges add to sparse normative data regarding body composition in children and adolescents and are based on a cohort with an obesity prevalence similar to current BMI charts. Awareness of subgroup differences aids in interpreting results.
Topics: Adolescent; Humans; Female; Child; United States; Male; Absorptiometry, Photon; Bone Density; Nutrition Surveys; Reference Values; Prospective Studies; Body Composition; Obesity; Body Mass Index
PubMed: 37598746
DOI: 10.1016/j.ajcnut.2023.08.006 -
Critical Care Medicine Dec 2023To address areas in which there is no consensus for the technologies, effort, and training necessary to integrate and interpret information from multimodality...
OBJECTIVES
To address areas in which there is no consensus for the technologies, effort, and training necessary to integrate and interpret information from multimodality neuromonitoring (MNM).
DESIGN
A three-round Delphi consensus process.
SETTING
Electronic surveys and virtual meeting.
SUBJECTS
Participants with broad MNM expertise from adult and pediatric intensive care backgrounds.
INTERVENTIONS
None.
MEASUREMENTS AND MAIN RESULTS
Two rounds of surveys were completed followed by a virtual meeting to resolve areas without consensus and a final survey to conclude the Delphi process. With 35 participants consensus was achieved on 49% statements concerning MNM. Neurologic impairment and the potential for MNM to guide management were important clinical considerations. Experts reached consensus for the use of MNM-both invasive and noninvasive-for patients in coma with traumatic brain injury, aneurysmal subarachnoid hemorrhage, and intracranial hemorrhage. There was consensus that effort to integrate and interpret MNM requires time independent of daily clinical duties, along with specific skills and expertise. Consensus was reached that training and educational platforms are necessary to develop this expertise and to provide clinical correlation.
CONCLUSIONS
We provide expert consensus in the clinical considerations, minimum necessary technologies, implementation, and training/education to provide practice standards for the use of MNM to individualize clinical care.
Topics: Adult; Child; Humans; Consensus; Delphi Technique; Surveys and Questionnaires; Reference Standards; Clinical Competence
PubMed: 37607072
DOI: 10.1097/CCM.0000000000006016 -
Journal of Cachexia, Sarcopenia and... Oct 2023Investigators are increasingly measuring skeletal muscle (SM) and adipose tissue (AT) change during cancer treatment to understand impact on patient outcomes. Recent... (Review)
Review
Investigators are increasingly measuring skeletal muscle (SM) and adipose tissue (AT) change during cancer treatment to understand impact on patient outcomes. Recent meta-analyses have reported high heterogeneity in this literature, representing uncertainty in the resulting estimates. Using the setting of palliative-intent chemotherapy as an exemplar, we aimed to systematically summarize the sources of variability among studies evaluating SM and AT change during cancer treatment and propose standards for future studies to enable reliable meta-analysis. Studies that measured computed tomography-defined SM and/or AT change in adult patients during palliative-intent chemotherapy for solid tumours were included, with no date or geographical limiters. Of 2496 publications screened by abstract/title, 83 were reviewed in full text and 38 included for extraction, representing 34 unique cohorts across 8 tumour sites. The timing of baseline measurement was frequently defined as prior to treatment, while endpoint timing ranged from 6 weeks after treatment start to time of progression. Fewer than 50% specified the actual time interval between measurements. Measurement error was infrequently discussed (8/34). A single metric (cm /m , cm or %) was used to describe SM change in 18/34 cohorts, while multiple metrics were presented for 10/34 and no descriptive metrics for 6/34. AT change metrics and sex-specific reporting were available for 10/34 cohorts. Associations between SM loss and overall survival were evaluated in 24 publications, with classification of SM loss ranging from any loss to >14% loss over variable time intervals. Age and sex were the most common covariates, with disease response in 50% of models. Despite a wealth of data and effort, heterogeneity in study design, reporting and statistical analysis hinders evidence synthesis regarding the severity and outcomes of SM and AT change during cancer treatment. Proposed standards for study design include selection of homogenous cohorts, clear definition of baseline/endpoint timing and attention to measurement error. Standard reporting should include baseline SM and AT by sex, actual scan interval, SM and AT change using multiple metrics and visualization of the range of change observed. Reporting by sex would advance understanding of sexual dimorphism in SM and AT change. Evaluating the impact of tissue change on outcomes requires adjustment for relevant covariates and concurrent disease response. Adoption of these standards by researchers and publishers would alter the current paradigm to enable meta-analysis of future studies and move the field towards meaningful application of SM and AT change to clinical care.
Topics: Adult; Female; Humans; Male; Adipose Tissue; Muscle, Skeletal; Neoplasms; Obesity; Reference Standards; Tomography, X-Ray Computed; Meta-Analysis as Topic
PubMed: 37675809
DOI: 10.1002/jcsm.13318 -
JACC. Cardiovascular Imaging Dec 2023Myocardial deformation by echocardiographic strain imaging is a key measurement in cardiology, providing valuable diagnostic and prognostic information. Reference ranges...
BACKGROUND
Myocardial deformation by echocardiographic strain imaging is a key measurement in cardiology, providing valuable diagnostic and prognostic information. Reference ranges for strain should be established from large healthy populations with minimal methodologic biases and variability.
OBJECTIVES
The aim of this study was to establish echocardiographic reference ranges, including lower normal limits of global strains for all 4 cardiac chambers, by guideline-directed dedicated views from a large healthy population and to evaluate the influence of subject-specific characteristics on strain.
METHODS
In total, 1,329 healthy participants from HUNT4Echo, the echocardiographic substudy of the 4th wave of the Trøndelag Health Study, were included. Echocardiographic recordings specific for each chamber were optimized according to current recommendations. Two experienced sonographers recorded all echocardiograms using GE HealthCare Vivid E95 scanners. Analyses were performed by experts using GE HealthCare EchoPAC.
RESULTS
The reference ranges for left ventricular (LV) global longitudinal strain and right ventricular free-wall strain were -24% to -16% and -35% to -17%, respectively. Correspondingly, left atrial (LA) and right atrial (RA) reservoir strains were 17% to 49% and 17% to 59%. All strains showed lower absolute values with higher age, except for LA and RA contractile strains, which were higher. The feasibility for strain was overall good (LV 96%, right ventricular 83%, LA 94%, and RA 87%). All chamber-specific strains were associated with age, and LV strain was associated with sex.
CONCLUSIONS
Reference ranges of strain for all cardiac chambers were established based on guideline-directed chamber-specific recordings. Age and sex were the most important factors influencing reference ranges and should be considered when using strain echocardiography.
Topics: Humans; Reference Values; Global Longitudinal Strain; Predictive Value of Tests; Echocardiography; Heart Atria; Ventricular Function, Left
PubMed: 37921718
DOI: 10.1016/j.jcmg.2023.08.011 -
Clinica Chimica Acta; International... Apr 2024Metrology in clinical chemistry aims to ensure the equivalence of measurement results from different in-vitro diagnostic measurement devices (IVD MD) for use in... (Review)
Review
Metrology in clinical chemistry aims to ensure the equivalence of measurement results from different in-vitro diagnostic measurement devices (IVD MD) for use in healthcare. The metrological traceability of measurement results to higher-order references is the cornerstone to achieving equivalent results. However, other fundamentals are also needed, including the commutability of reference materials and external quality assessment (EQA) materials for monitoring the equivalence of measurement results at the end-user level. This manuscript summarizes the findings and opinions expressed at the Joint Community for Traceability in Laboratory Medicine (JCTLM) workshop held on December 4-5, 2023. The workshop explored the relationship between EQA/proficiency testing and metrological traceability to higher-order references. EQA monitors the equivalence of measurement results from end-user IVD MDs. The workshop discussed the role and challenges of using EQA to improve and maintain the equivalence of measurement results. It also elucidated current developments in establishing the clinical suitability of laboratory results expressed as analytical performance specifications (APS).
Topics: Clinical Laboratory Techniques; Laboratories; Laboratory Proficiency Testing; Quality Assurance, Health Care; Reference Standards
PubMed: 38493945
DOI: 10.1016/j.cca.2024.117876 -
The Journal of Applied Laboratory... Jul 2023N-terminal pro-B-type natriuretic peptide (NT-proBNP) is a cardiac biomarker used in the clinical management of heart failure. We sought to create updated reference...
BACKGROUND
N-terminal pro-B-type natriuretic peptide (NT-proBNP) is a cardiac biomarker used in the clinical management of heart failure. We sought to create updated reference intervals for NT-proBNP for healthy US children, adolescents, and adults.
METHODS
We identified a population of healthy individuals using the 1999 to 2004 cycles of the National Health and Nutrition Examination Survey (NHANES). We measured serum NT-proBNP in 12 346 adults and 15 752 children and adolescents with the Elecsys NT-proBNP assay on the Roche e601 autoanalyzer. We compared 4 methods for reference interval calculation, and presented the final reference intervals using the robust method partitioned by age and sex categories.
RESULTS
NT-proBNP values were available for 1949 healthy adults and 5250 healthy children and adolescents. NT-proBNP concentrations in males and females varied according to age, being higher in early childhood, relatively lower in late adolescence, and highest through middle age and older age. Females tended to have higher NT-proBNP concentrations compared to men from late adolescence until middle age. The upper reference limit, or 97.5th percentile, for 50 to 59 year-old men was 225 ng/L (90% CI: 158 to 236), and for 50 to 59 year-old women, 292 ng/L (90% CI: 242 to 348).
CONCLUSIONS
Among healthy individuals, NT-proBNP concentrations varied greatly according age and sex. The reference intervals presented here should inform future clinical decision limits and suggest that age- and sex-specific intervals may be necessary to more precisely characterize risk.
Topics: Male; Middle Aged; Humans; Adult; Child; Child, Preschool; Female; Adolescent; Natriuretic Peptide, Brain; Nutrition Surveys; Reference Values; Peptide Fragments
PubMed: 37279581
DOI: 10.1093/jalm/jfad024