European Journal of Dentistry Jul 2023This study aimed to evaluate the effectiveness of conventional occlusal analysis in contrast with digital occlusal analysis in natural dentition. Occlusal analysis...
This study aimed to evaluate the effectiveness of conventional occlusal analysis in contrast with digital occlusal analysis in natural dentition. Occlusal analysis allows the identification of normal and abnormal occlusal contact points that alter the craniomandibular cervical system. We searched for articles with keywords [[dental occlusion]], [[natural dentition]], [[occlusal adjustment]], [[Immediate Complete Anterior Guidance Development]] [[mastication]], [[bite force]], [[premature contact]], [[occlusal balance]] [[articulating paper]]], [[spray]], [[Occlusal contacts]], and [[bite strength]]. They were considered observational , odds ratio and case control studies. We found 189 items. After evaluating the abstracts and full texts of the articles, 10 papers met the inclusion criteria. It was found that occlusal analysis allows the identification of the relationship between poor occlusion and the sensitivity of the teeth due to occlusal trauma, which is also related to temporomandibular joint pain in dynamic occlusion. The contacts of greater strength were observed in nonfunctional cusps, 48%, without ruling out the functional cusps, 24%. Despite being the universal method of occlusal control to date, the use of joint paper, remains subjective compared to the digital occlusal control device. Posture is considered directly related to occlusal trauma and temporomandibular disorders; without proper occlusal analysis, a clear diagnosis of the patient's joint condition cannot be obtained. Digital occlusal analysis is more objective than traditional occlusal analysis.
PubMed: 36252609
DOI: 10.1055/s-0042-1755626 -
Scientific Reports Dec 2023How to ensure dental stability in new positions and reduce the likelihood of relapse is a major clinical concern in the orthodontic field. Occlusal contacts between...
How to ensure dental stability in new positions and reduce the likelihood of relapse is a major clinical concern in the orthodontic field. Occlusal contacts between arches may affect the transmission of masticatory forces, thereby influencing the biological response of the periodontal and the oromandibular system. Occlusion factors that may influence the stability after orthodontic tooth movement (OTM) remain largely unknown. Hence, this research was conducted in order to investigate the influence of different occlusal contact patterns on tooth stability and oromandibular system including the masseter muscle and the temporomandibular joint following OTM. By modifying the occlusal surfaces, in vivo animal study models with distinct occlusal patterns corresponding to clinical circumstances were established. The relapse distance of teeth and the level of inflammatory factors in the gingival cervical fluid were analyzed. We also closely observed the histological remodeling of periodontal tissue, masseter tissue, and joint tissue after one week of relapse. Moreover, genes expression in the alveolar bone was analyzed to illustrate the potential biological mechanisms of relapse under the influence of different occlusal contact patterns following OTM. Different occlusal contact patterns after OTM in rats were established. The intercuspation contact between cusp and fossa group exhibited the lowest level of relapse movement, inflammatory factors and osteoclast activity (P < 0.05). On the other hand, groups with interferences or inadequate contacts exhibited more relapse movement, and tend to promote inflammation of periodontal tissue and activate bone resorption (P < 0.05). Adequate occlusal contacts without interference may enhance tooth stability and reduce the likelihood of relapse. After active orthodontic treatment, necessary occlusal adjustment should be made to achieve the desired intercuspation contact relationship and ensure adequate contact between the arches. The elimination of occlusal interferences is crucial to achieving optimal stability and promoting overall healthy condition of the oromandibular system.
Topics: Rats; Animals; Tooth Movement Techniques; Osteoclasts; Bone Resorption; Recurrence
PubMed: 38097596
DOI: 10.1038/s41598-023-46668-x -
BMC Oral Health Jun 2023This study is to investigate the referral pattern and treatment modality of dentists in the management of peri-implant diseases between periodontists and...
OBJECTIVES
This study is to investigate the referral pattern and treatment modality of dentists in the management of peri-implant diseases between periodontists and non-periodontist dentists (NPDs).
MATERIALS AND METHODS
A total of 167 validated questionnaires were obtained from periodontists and NPDs, who had experience of placing implants for at least one year. Question I to IV asked how the dentist would respond if a patient came for treatment of their peri-implant diseases with four different scenarios according to resource of patient and disease severity. For each Scenario, dentists also replied which treatment procedures they would use if they decide to treat the patient.
RESULTS
Periodontal training, resource of patient, and disease severity were shown to significantly influence the referral pattern and treatment modality in the management of peri-implant disease (p < 0.05). Periodontists were more likely to use variable treatment procedures, including occlusal adjustment (OR = 2.283, p < 0.01), oral hygiene instruction (OR = 3.751, p < 0.001), topical antiseptic agent (OR = 2.491, p < 0.005), non-surgical mechanical therapy (OR = 2.689, p < 0.001), surgical therapy (OR = 2.009, p < 0.01), and remove implant (OR = 3.486, p < 0.001) to treat peri-implant diseases, compared to NPDs.
CONCLUSION
The periodontal specialty training, resource of patient, and disease severity significantly influenced the referral pattern and treatment modality of dentist treating an implant diagnosed with peri-implant disease. This study also highlighted the importance of educating basic periodontal and peri-implant disease-related knowledge to all dentists regularly performing dental implant treatments.
CLINICAL RELEVANCE
Peri-implant diseases are highly prevalent among patients with dental implants. Periodontal specialty training could enhance using variable treatment procedures to treat peri-implant diseases for dentists.
Topics: Humans; Peri-Implantitis; General Practice, Dental; Dental Implants; Dentists; Referral and Consultation
PubMed: 37370067
DOI: 10.1186/s12903-023-03135-3 -
Clinical Oral Investigations Feb 2024Single denture rehabilitated patients have negative appraisals regarding oral function, mostly associated by stability and retention issues regarding mandibular... (Randomized Controlled Trial)
Randomized Controlled Trial
OBJECTIVES
Single denture rehabilitated patients have negative appraisals regarding oral function, mostly associated by stability and retention issues regarding mandibular prosthetics. Therefore, this study assessed patients' occlusal equilibration, muscle activity, and oral health-related quality of life (OHRQoL) receiving milled removable or fixed mandibular implant retained prostheses.
MATERIALS AND METHODS
Twenty-two edentulous mandibular ridges patients were randomly distributed into two groups based on the definitive prosthesis received. Group I: Removable mandibular implant-supported overdenture, Group II: Implant retained fixed prosthesis. Occlusal equilibration was evaluated utilizing Occlusense, muscle activity via Electromyograph (EMG) at delivery, after one, and three months. The OHRQoL was evaluated by Oral Health Impact Profile questionnaire (OHIP-19) before delivery and after follow-ups. Data were collected, tabulated, and analyzed, utilizing independent t-test and One-way ANOVA followed Tukey`s post-hoc test. Significance level set at P ≤ 0.05.
RESULTS
Groups I &II showed significant improvement in occlusal equilibration, muscle activity and OHRQoL. Group II demonstrated significantly higher improvement than group I in occlusal equilibration associated with muscle activity after 1 month, and in functional limitations domain in OHRQoL questionnaire after 3 months.
CONCLUSION
Implant retained mandibular prosthesis showed improvement in occlusal equilibration, muscle activity, and OHRQoL regardless of prosthesis type employed. Fixed implant-supported prosthesis revealed better outcomes than removable mandibular implant-supported overdenture concerning occlusal equilibration, muscle activity, and OHRQoL regarding functional limitations.
CLINICAL RELEVANCE
Implant retained mandibular prosthesis is one of best treatment options for single mandibular completely edentulous patients, as dental implants improved occlusal equilibration, muscle activity, and OHRQoL.
Topics: Humans; Dental Implants; Dental Prosthesis, Implant-Supported; Denture, Overlay; Jaw, Edentulous; Mandible; Mouth, Edentulous; Muscles; Occlusal Adjustment; Patient Satisfaction; Quality of Life
PubMed: 38378935
DOI: 10.1007/s00784-024-05558-w -
BMC Oral Health Mar 2024Overerupted maxillary molars is common in adults, which can lead to insufficient intermaxillary vertical space ,great difficulty in prosthetic reconstruction ,and cause...
BACKGROUND
Overerupted maxillary molars is common in adults, which can lead to insufficient intermaxillary vertical space ,great difficulty in prosthetic reconstruction ,and cause occlusal interference in movements.To reconstruct occlusal function, it is necessary to prepare enough space for prostheses. The aim of the present study was to evaluate the effect of space-adjustment occlusal splint on overerupted maxillary molars by clinical and electromyographic signals analysis.
METHODS
Eighteen patients with overerupted maxillary molars were selected to wear space-adjustment occlusal splint suppressing overerupted maxillary molars for three months. Satisfaction was assessed by 5-point Likert; intermaxillary vertical space and the teeth transportation distance were measured in models; clinical periodontal status were evaluated by periodontal probing depth (PPT) and bleeding index (BI); electromyographic recordings of the masseter and anterior temporal muscles were monitored by Cranio-Mandibular K7 Evaluation System.
RESULTS
All the patients were satisfied with the treatment effect (Likert scale ≧ 4). The intermaxillary space in edentulous areas after treatment showed statistically significant increasing when compared with those before treatment. PPT and BI showed no significant difference. No statistically significant differences were found in electromyographic activity of anterior temporal muscles, while a reduction of muscle activity in masseter in the contralateral side were detected in post-treatment evaluations compared with pre-treatment at mandibular rest position.
CONCLUSIONS
Space-adjustment occlusal splint is an efficient treatment option on overerupted maxillary molars by intruding the maxillary molar to obtain adequate intermaxillary space for prostheses.
Topics: Adult; Humans; Splints; Molar; Masseter Muscle; Temporal Muscle; Occlusal Splints; Electromyography
PubMed: 38431564
DOI: 10.1186/s12903-024-04039-6 -
BMC Oral Health Feb 2024This study aims to analyze the longitudinal variation of occlusal force distribution prior to and after fixed restoration for molar full-crowns with T-SCAN III which...
BACKGROUND
This study aims to analyze the longitudinal variation of occlusal force distribution prior to and after fixed restoration for molar full-crowns with T-SCAN III which provide reference for occlusal adjustment and long-term maintenance.
METHODS
We enrolled a total of 20 patients who received conventional restorative treatment for molars. The occlusion examination was conducted in 3 stages (before placement, immediately after placement, and 3 months after placement) using T-SCAN III (Tekscan South Boston, MA, USA, 10.0) to examine and measure the occlusal contact areas of the full dentition.
RESULTS
The results indicated that the occlusal force distribution in the molar region of the patients changed before and after the fixed restoration, but the percentages of occlusal force in the dental arch of the molar did not differ significantly before and after the restoration (P > 0.05). Three months after the fixed restoration, the percentage of occlusal force in the restored dental arches of lateral teeth increased significantly (P < 0.05).
CONCLUSION
The results of this study indicated that the occlusal forces of the patients changed with tooth movement and adaptation, which is mainly reflected in the increasing occlusal force. Quantitative occlusal force analysis using T-SCAN III occlusal analyzer can provide more objective and accurate data to effectively guide clinical occlusion adjustments.
Topics: Humans; Dental Occlusion; Bite Force; Molar; Crowns; Dentures
PubMed: 38388920
DOI: 10.1186/s12903-024-04014-1 -
The Journal of Prosthetic Dentistry Apr 2024The alignment of the maxillary and mandibular digital scans obtained with an intraoral scanner (IOS) generates digital interocclusal records. Although the accuracy of...
STATEMENT OF PROBLEM
The alignment of the maxillary and mandibular digital scans obtained with an intraoral scanner (IOS) generates digital interocclusal records. Although the accuracy of maxillary and mandibular digital scans obtained from an IOS is widely studied, the accuracy of digital interocclusal records obtained with them is not; even less studied is the accuracy (trueness and precision) of the alignment methods that are available to obtain them.
PURPOSE
The purpose of this in vitro study was to assess the precision under repeatability conditions (repeatability) of the different alignment methods used to obtain digital interocclusal records.
MATERIAL AND METHODS
Digital scans of maxillary and mandibular casts of a dentate healthy adult were acquired with an IOS. Casts were then mounted in maximum intercuspal position in a semi-adjustable mechanical articulator (1801 AR Model PSH Articulator), and left and right occlusal digital scans were acquired with the IOS. Occlusal digital scans were repeated 7 times under repeatability conditions. After obtaining each pair of occlusal digital scans, the software program of the IOS automatically aligned the maxillary and mandibular digital scans with occlusal digital scans (TRI method), resulting in 7 digital interocclusal records composed of aligned maxillary and mandibular digital scans and occlusal digital scans. All 7 sets of aligned digital scans were exported and realigned in a dental computer-aided design software program by means of global and reference alignment methods (EXO-B and EXO-R methods, respectively). To assess the repeatability, the 7 aligned digital scan sets of each group were repositioned in the common coordinate system by aligning maxillary digital scans, and repeatability was calculated in terms of the distance between the vertices of the mandibular digital scans for each of the possible nonrepeating combinations of pairs (C=21). The repeatability was tested by using the Kruskal-Wallis test for nonparametric distribution followed by the Mann-Whitney U test and Bonferroni correction for pairwise comparisons (α=.05).
RESULTS
The median with interquartile range for the TRI alignment method was 47 (27) μm for the EXO-B method 41 (25) μm and 16 (5) μm for EXO-R. The Kruskal-Wallis test showed statistical difference between test groups (P<.05). The post hoc Dunn test with Bonferroni adjustment detected significant statistical differences between the EXO-R-TRI (P<.001) and EXO-R-EXO-B (P<.001) alignment methods.
CONCLUSIONS
This study found that the alignment method could influence the repeatability of digital interocclusal records. The reference best-fit alignment method (EXO-R) provided better repeatability.
Topics: Imaging, Three-Dimensional; Models, Dental; Dental Impression Technique; Software; Computer-Aided Design
PubMed: 36115710
DOI: 10.1016/j.prosdent.2022.07.014 -
BMC Oral Health Mar 2024To compare the crown accuracy and time efficiency of a complete digital workflow, utilizing an auxiliary occlusal device and IO scanning, with a conventional workflow,... (Randomized Controlled Trial)
Randomized Controlled Trial
OBJECTIVES
To compare the crown accuracy and time efficiency of a complete digital workflow, utilizing an auxiliary occlusal device and IO scanning, with a conventional workflow, for multiple implant-supported single crowns.
MATERIALS AND METHODS
24 patients with two adjacent posterior implants were included. 12 patients were randomly assigned to digital workflow group, involving intra-oral scanning with an auxiliary occlusal device and manufacture of customized abutments and zirconia single crowns (test group). The other 12 were assigned to the conventional workflow (control group), involving conventional impression and CAD-CAM crowns based on stone casts. Crown scanning was done before and after clinical adjustment using an intraoral scanner. Two 3D digital models were overlapped to assess dimension changes. Chair-side and laboratory times for the entire workflow were recorded and a linear mixed model and Independent-sample t tests were used for the statistical analysis.
RESULTS
The maximum occlusal deviation was 279.67 ± 112.17 μm and 479.59 ± 203.63 μm in the test and control group, respectively (p < 0.001). The sizes of the occlusion adjustment areas were 12.12 ± 10.51 mm and 25.12 ± 14.14 mm in the test and control groups, respectively (p = 0.013). The mean laboratory time was 46.08 ± 5.45 and 105.92 ± 6.10 min in the test and control groups, respectively (p < 0.001).The proximal contact adjustment and mean chair-side time showed no statistically significant difference between two groups.
CONCLUSIONS
A digital workflow for two implants-supported single crowns using an auxiliary device required fewer occlusal crown adjustments, and less laboratory time compared to conventional workflow.
CLINICAL RELEVANCE
The use of auxiliary occlusal devices in IOS enhances the accuracy of virtual maxillomandibular relationship in extended edentulous spans. Consequently, employing a digital workflow for multiple implants-supported crowns using IO scanning and an auxiliary occlusal device proves to be a feasible, accurate and efficient approach.
Topics: Humans; Workflow; Dental Prosthesis Design; Dental Implants; Crowns; Computer-Aided Design
PubMed: 38519905
DOI: 10.1186/s12903-024-03986-4 -
Clinical Oral Investigations Jan 2024The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed...
OBJECTIVES
The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations.
MATERIALS AND METHODS
Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests.
RESULTS
Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs.
CONCLUSIONS
Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity.
CLINICAL RELEVANCE
Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided.
Topics: Dental Restoration Failure; Ceramics; Zirconium; Denture, Partial, Fixed; Dental Porcelain; Materials Testing; Dental Stress Analysis; Crowns
PubMed: 38221600
DOI: 10.1007/s00784-024-05501-z -
Heliyon Jan 2024The effect of using the custom disk method (CDM) for fabricating digital dentures on patients' masticatory function should be studied to support its use in clinical...
STATEMENT OF PROBLEM
The effect of using the custom disk method (CDM) for fabricating digital dentures on patients' masticatory function should be studied to support its use in clinical practice.
PURPOSE
To investigate the effect of digital dentures fabricated using CDM on patients' masticatory function.
MATERIAL AND METHODS
This single-center prospective clinical study included 20 patients with edentulous maxillary and mandibular arches who used a complete denture. The digital impression and complete denture manufacturing procedures using CDM have already been reported by Kanazawa et al. (2018) [32] and Soeda et al. (2022) [18] Thedigital dentures fabricated with CDM were delivered to the participants, and periodic adjustments were made until the patient could use the denture without pain. A color-changeable chewing gum, two types of gummy jellies that can evaluate the masticatory function, and pressure-sensitive sheets were used to evaluate the participants' masticatory function at baseline, 1 month, and 6 months following adjustment of the new digital complete dentures fabricated with CDM. These masticatory function values had already been measured in the previous conventional dentures and were recorded as baseline values.
RESULTS
The study participants included 8 women and 12 men (mean age, 77.6 years). The color-changeable chewing gum analysis indicated that there was no significant improvement of masticatory function from baseline to 1 M (P = .083) and 6 M (P = .157).The gummy jelly analysis indicated no significant differences between the masticatory function baseline and 1 month (P = .387); however, a significant improvement was observed from baseline to 6 months (P = .020). Tests with Glucolum indicated a significant improvement from baseline to 1 month (P = .012) and 6 months (P = .003). The maximum bite force and occlusal contact area showed no significant difference at any time point.
CONCLUSIONS
Significant improvement in masticatory function was observed upon evaluation with gummy jelly and Glucolum 6 months after delivering the new digital complete dentures. Under limited conditions, the digital denture fabricated using CDM resulted in good recovery of the masticatory function in elderly edentulous patients. The present results combined with the cost-effectiveness and patient satisfaction associated with CDM indicate its clinical utility.
PubMed: 38192789
DOI: 10.1016/j.heliyon.2023.e23938