Journal of Cardiothoracic Surgery Jun 2024We aimed to summarise the existing knowledge regarding antithrombotic medications following surgical aortic valve replacement (SAVR) using a biological valve prosthesis. (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
We aimed to summarise the existing knowledge regarding antithrombotic medications following surgical aortic valve replacement (SAVR) using a biological valve prosthesis.
METHODS
We performed a meta-analysis of studies that reported the results of using antithrombotic medication to prevent thromboembolic events after SAVR using a biological aortic valve prosthesis and recorded the outcomes 12 months after surgery. Since no randomised controlled trials were identified, observational studies were included. The analyses were conducted separately for periods of 0-12 months and 3-12 months after surgery. A random effects model was used to calculate pooled outcome event rates and 95% confidence intervals (CIs).
RESULTS
The search yielded eight eligible observational studies covering 6727 patients overall. The lowest 0- to 12-month mortality was observed in patients with anticoagulation (2.0%, 95% CI 0.4-9.7%) and anticoagulation combined with antiplatelet therapy (2.2%, 95% CI 0.9-5.5%), and the highest was in patients without antithrombotic medication (7.3%, 95% CI 3.6-14.2%). Three months after surgery, mortality was lower in anticoagulant patients (0.5%, 95% CI 0.1-2.6%) than in antiplatelet patients (3.0%, 95% CI 1.2-7.4%) and those without antithrombotics (3.5%, 95% CI 1.3-9.3%). There was no eligible evidence of differences in stroke rates observed among medication strategies. At 0- to 12-month follow-up, all antithrombotic treatment regimens resulted in an increased bleeding rate (antiplatelet 4.2%, 95% CI 2.9-6.1%; anticoagulation 7.5%, 95% CI 3.8-14.4%; anticoagulation combined with antiplatelet therapy 8.3%, 95% CI 5.7-11.8%) compared to no antithrombotic medication (1.1%, 95% CI 0.4-3.4%). At 3- to 12-month follow-up, there was up to an eight-fold increase in the bleeding rate in patients with anticoagulation combined with antiplatelet therapy when compared to those with no antithrombotic medication. Overall, the evidence certainty was ranked as very low.
CONCLUSION
Although this meta-analysis reveals that anticoagulation therapy has a beneficial tendency in terms of mortality at 1 year after biological SAVR and suggests potential advantages in continuing anticoagulation beyond 3 months, it is limited by very low evidence certainty. The imperative for cautious interpretation and the urgent need for more robust randomised research underscore the complexity of determining optimal antithrombotic strategies in this patient population.
Topics: Humans; Fibrinolytic Agents; Heart Valve Prosthesis; Aortic Valve; Heart Valve Prosthesis Implantation; Thromboembolism; Bioprosthesis; Postoperative Complications; Anticoagulants; Platelet Aggregation Inhibitors
PubMed: 38926789
DOI: 10.1186/s13019-024-02863-z -
Frontiers in Cardiovascular Medicine 2023Occlusion of the left coronary circumflex artery (LCX) during surgical procedures of the mitral valve is an infrequent but potentially life-threatening complication... (Review)
Review
Occlusion of the left coronary circumflex artery (LCX) during surgical procedures of the mitral valve is an infrequent but potentially life-threatening complication (1-3). Due to its close anatomical relationship to the posterior mitral valve annulus, there is a relevant risk of causing a stenosis or an occlusion of the left circumflex artery, especially by surgical annular sutures. The perioperative clinical course is heterogeneous, ranging from-initially-asymptomatic or solely electrocardiographic abnormalities to cardiogenic shock. Both severely impaired ventricular contractility or malignant arrhythmia may potentially lead to a weaning failure from cardiopulmonary bypass (CPB) and eventually result in chronic heart failure with persistently reduced ejection fraction. Possible therapeutic strategies include the immediate reopening of causal sutures, aortocoronary bypass grafting or percutaneous coronary intervention (PCI), yet PCI seems to be the preferred method at present.
PubMed: 37965081
DOI: 10.3389/fcvm.2023.1183182 -
Journal of Cardiothoracic Surgery May 2024Although well-known for their thromboresistance, bileaflet mechanical heart valves (BMHV) require lifelong anti-thrombotic therapy. This must be associated with a...
BACKGROUND
Although well-known for their thromboresistance, bileaflet mechanical heart valves (BMHV) require lifelong anti-thrombotic therapy. This must be associated with a certain level of thrombogenicity. Since both thromboresistance and thrombogenicity are explained by the blood-artificial surface or liquid-solid interactions, the aim of the present study was to explore BMHV thromboresistance from new perspectives. The wettability of BMHV pyrolytic carbon (PyC) occluders was investigated in under-liquid conditions. The submerged BMHV wettability clarifies the mechanisms involved in the thromboresistance.
METHODS
The PyC occluders of a SJM Regent™ BMHV were previously laser irradiated, to create a surface hierarchical nano-texture, featuring three nano-configurations. Additionally, four PyC occluders of standard BMHV (Carbomedics, SJM Regent, Bicarbon, On-X), were investigated. All occluders were evaluated in under-liquid configuration, with silicon oil used as the working droplet, while water, simulating blood, was used as the surrounding liquid. The under-liquid droplet-substrate wetting interactions were analyzed using contact angle goniometry.
RESULTS
All the standard occluders showed very low contact angle, reflecting a pronounced affinity for non-polar molecules. No receding of the contact line could be observed for the untreated occluders. The smallest static contact angle of around 61° could be observed for On-X valve (the only valve made of full PyC). The laser-treated occluders strongly repelled oil in underwater conditions. A drastic change in their wetting behaviour was observed depending on the surrounding fluid, displaying a hydrophobic behaviour in the presence of air (as the surrounding medium), and showing instead a hydrophilic nature, when surrounded by water.
CONCLUSIONS
BMHV "fear" water and blood. The intrinsic affinity of BMHV for nonpolar fluids can be translated into a tendency to repel polar fluids, such as water and blood. The blood-artificial surface interaction in BMHV is minimized. The contact between blood and BMHV surface is drastically reduced by polar-nonpolar Van der Waals forces. The "hydro/bloodphobia" of BMHV is intrinsically related to their chemical composition and their surface energy, thus their material: PyC indeed. Pertaining to thromboresistance, the surface roughness does not play a significant role. Instead, the thromboresistance of BMHV lies in molecular interactions. BMHV wettability can be tuned by altering the surface interface, by means of nanotechnology.
Topics: Heart Valve Prosthesis; Wettability; Humans; Thrombosis; Prosthesis Design; Materials Testing
PubMed: 38760659
DOI: 10.1186/s13019-024-02786-9 -
Journal of Cardiothoracic Surgery Feb 2024The extent of aortic valve inflammation in patients undergoing aortic valve replacement (AVR) is unsettled. The significance of aortic valve histopathology in patients...
BACKGROUND
The extent of aortic valve inflammation in patients undergoing aortic valve replacement (AVR) is unsettled. The significance of aortic valve histopathology in patients undergoing AVR is undetermined.
METHODS
A total of 145 resected aortic valves of consecutive patients undergoing surgery for a local aortic valve disease with or without ascending aorta were investigated for histopathology. The extent of inflammation and degeneration were investigated. Unadjusted survival was evaluated by Kaplan-Meier analysis. Median follow-up was 2.7 years (interquartile range 1.5-3.9).
RESULTS
Mean patient age was 69 (SD 11) years. Though endocarditis was apparent in only six patients preoperatively, severe aortic valve inflammation was diagnosed histologically in 32 patients of whom 12 patients had acute, subacute or chronic endocarditis. Despite complete aortic valve resection, survival was decreased in patients with severe aortic valve inflammation as opposed to those without (log rank, P = 0.044), even after exclusion of patients with endocarditis, emergency and aortic surgery.
CONCLUSIONS
Aortic valve tissue analysis reveals severe inflammation that may require postoperative treatment. The association of severe but local aortic valve inflammation with patient outcome after aortic valve surgery merits further investigation.
Topics: Humans; Aged; Aortic Valve; Heart Valve Diseases; Treatment Outcome; Heart Valve Prosthesis Implantation; Heart Valve Prosthesis; Endocarditis; Inflammation; Retrospective Studies
PubMed: 38308340
DOI: 10.1186/s13019-024-02587-0 -
Open Heart Jan 2024A quarter of patients with severe aortic stenosis (AS) were asymptomatic, and only a third of them survived at the end of 4 years. Only a select subset of these patients... (Meta-Analysis)
Meta-Analysis
Systematic review and meta-analysis of early aortic valve replacement versus conservative therapy in patients with asymptomatic aortic valve stenosis with preserved left ventricle systolic function.
BACKGROUND
A quarter of patients with severe aortic stenosis (AS) were asymptomatic, and only a third of them survived at the end of 4 years. Only a select subset of these patients was recommended for aortic valve replacement (AVR) by the current American College of Cardiology/American Heart Association guidelines. We intended to study the effect of early AVR (eAVR) in this subset of asymptomatic patients with preserved left ventricle function.
METHODS AND RESULTS
We searched PubMed and Embase for randomised and observational studies comparing the effect of eAVR versus conservative therapy in patients with severe, asymptomatic AS and normal left ventricular function. The primary outcome was all-cause mortality. The secondary outcomes were composite major adverse cardiac events (MACE) (study defined), myocardial infarction (MI), stroke, cardiac death, sudden death, the development of symptoms, heart failure hospitalisations and major bleeding. We used GRADEPro to assess the certainty of the evidence. In the randomised controlled trial (RCT) only analysis, we found no significant difference in all-cause mortality between the early aortic intervention group versus the conservative arm (CA) (incidence rate ratio, IRR (CI): 0.5 (0.2 to 1.1), I=31%, p=0.09). However, in the overall cohort, we found mortality benefit for eAVR over CA (IRR (CI): 0.4 (0.3 to 0.7), I=84%, p<0.01). There were significantly lower MACE, cardiac death, sudden death, development of symptoms and heart failure hospitalisations in the eAVR group. We noticed no difference in MI, stroke and major bleeding.
CONCLUSION
We conclude that there is no reduction in all-cause mortality in the eAVR arm in patients with asymptomatic AS with preserved ejection fraction. However, eAVR reduces heart failure related hospitalisations and death or heart failure hospitalisations.
PROSPERO REGISTRATION NUMBER
CRD42022306132.
Topics: Humans; Aortic Valve; Aortic Valve Stenosis; Conservative Treatment; Death, Sudden, Cardiac; Heart Failure; Hemorrhage; Myocardial Infarction; Stroke; United States; Ventricular Function, Left; Heart Valve Prosthesis Implantation; Transcatheter Aortic Valve Replacement
PubMed: 38191233
DOI: 10.1136/openhrt-2023-002511 -
Innovations (Philadelphia, Pa.) 2024The surgical treatment of aortic stenosis continues to evolve, and sutureless aortic valve replacement (SUAVR) is an emerging technology. With the Perceval S (Corcym,... (Review)
Review
OBJECTIVE
The surgical treatment of aortic stenosis continues to evolve, and sutureless aortic valve replacement (SUAVR) is an emerging technology. With the Perceval S (Corcym, London, UK) as the only true sutureless valve on the market, the objective of this review is to analyze the current literature on Perceval S. Focusing on valve design and deployment as well as applications of the technology for challenging pathology, clinical outcomes are assessed, including a comparison with transcatheter AVR (TAVR).
METHODS
PubMed and MEDLINE were searched by 3 authors for studies analyzing SUAVR from inception to May 19, 2023.
RESULTS
SUAVR facilitates minimally invasive surgery and offers an alternative strategy for patients with small aortic annuli. It also has a time-saving advantage for patients who require complex operations. SUAVR results in excellent long-term morbidity, mortality, durability, and hemodynamic function. In comparison with conventional surgical AVR (SAVR), SUAVR does have a greater risk of postoperative pacemaker implantation; however, increasing user experience and refinements in implantation technique have contributed to reductions in this outcome. SUAVR results in morbidity and mortality that is similar to rapid-deployment AVR. Midterm outcomes are superior to TAVR; however, further robust investigation into all of these comparisons is ultimately necessary.
CONCLUSIONS
SUAVR bridges the gap in technology between SAVR and TAVR. The application of this exciting technology will undoubtedly grow in the coming years, during which additional investigation is paramount to optimize preoperative planning, valve deployment, and reintervention strategies.
Topics: Humans; Bioprosthesis; Heart Valve Prosthesis; Aortic Valve Stenosis; Aortic Valve; Sutureless Surgical Procedures; Transcatheter Aortic Valve Replacement; Heart Valve Prosthesis Implantation; Prosthesis Design; Minimally Invasive Surgical Procedures; Treatment Outcome
PubMed: 38465600
DOI: 10.1177/15569845241231989 -
JACC. Cardiovascular Imaging Jun 2024Conflicting results from 2 randomized clinical trials of transcatheter mitral valve edge-to-edge repair in secondary mitral regurgitation (SMR) have led to the... (Review)
Review
Conflicting results from 2 randomized clinical trials of transcatheter mitral valve edge-to-edge repair in secondary mitral regurgitation (SMR) have led to the recognition that SMR is a heterogeneous disease entity presenting with different functional and morphological phenotypes. This review summarizes the current knowledge on SMR caused primarily by atrial secondary mitral regurgitation (aSMR) and ventricular SMR pathology. Although aSMR is generally characterized by severe left atrial enlargement in the setting of preserved left ventricular anatomy and function, different patterns of mitral annular distortion cause different phenotypes of aSMR. In ventricular SMR, the relation of SMR severity to left ventricular dilation as well as the degree of pulmonary hypertension and right ventricular dysfunction are important phenotypic characteristics, which are key for a better understanding of prognosis and treatment response.
Topics: Mitral Valve Insufficiency; Humans; Phenotype; Mitral Valve; Echocardiography, Transesophageal; Predictive Value of Tests; Severity of Illness Index; Ventricular Function, Left; Randomized Controlled Trials as Topic; Treatment Outcome; Cardiac Catheterization; Heart Valve Prosthesis Implantation
PubMed: 38551534
DOI: 10.1016/j.jcmg.2024.01.012 -
Acta Biomaterialia Oct 2023Calcific degeneration is the most frequent type of heart valve failure, with rising incidence due to the ageing population. The gold standard treatment to date is valve...
Calcific degeneration is the most frequent type of heart valve failure, with rising incidence due to the ageing population. The gold standard treatment to date is valve replacement. Unfortunately, calcification oftentimes re-occurs in bioprosthetic substitutes, with the governing processes remaining poorly understood. Here, we present a multiscale, multimodal analysis of disturbances and extensive mineralisation of the collagen network in failed bioprosthetic bovine pericardium valve explants with full histoanatomical context. In addition to highly abundant mineralized collagen fibres and fibrils, calcified micron-sized particles previously discovered in native valves were also prevalent on the aortic as well as the ventricular surface of bioprosthetic valves. The two mineral types (fibres and particles) were detectable even in early-stage mineralisation, prior to any macroscopic calcification. Based on multiscale multimodal characterisation and high-fidelity simulations, we demonstrate that mineral occurrence coincides with regions exposed to high haemodynamic and biomechanical indicators. These insights obtained by multiscale analysis of failed bioprosthetic valves serve as groundwork for the evidence-based development of more durable alternatives. STATEMENT OF SIGNIFICANCE: Bioprosthetic valve calcification is a well-known clinically significant phenomenon, leading to valve failure. The nanoanalytical characterisation of bioprosthetic valves gives insights into the highly abundant, extensive calcification and disorganization of the collagen network and the presence of calcium phosphate particles previously reported in native cardiovascular tissues. While the collagen matrix mineralisation can be primarily attributed to a combination of chemical and mechanical alterations, the calcified particles are likely of host cellular origin. This work presents a straightforward route to mineral identification and characterization at high resolution and sensitivity, and with full histoanatomical context and correlation to hemodynamic and biomechanical indicators, hence providing design cues for improved bioprosthetic valve alternatives.
Topics: Animals; Cattle; Heart Valve Prosthesis; Bioprosthesis; Heart Valves; Calcinosis; Collagen; Heart Failure; Aortic Valve
PubMed: 37517619
DOI: 10.1016/j.actbio.2023.07.044 -
Journal of Cardiovascular Translational... Aug 2023Coronary flow obstruction following transcatheter aortic valve-in-valve implantation (VIV-TAVI) is associated with a high mortality risk. The aim of this work was to...
Coronary flow obstruction following transcatheter aortic valve-in-valve implantation (VIV-TAVI) is associated with a high mortality risk. The aim of this work was to quantify the coronary perfusion after VIV-TAVI in a high-risk aortic root anatomy. 3D printed models of small aortic root were used to simulate the implantation of a TAVI prosthesis (Portico 23) into surgical prostheses (Trifecta 19 and 21). The aortic root models were tested in a pulsatile in vitro bench setup with a coronary perfusion simulator. The tests were performed at baseline and post-VIV-TAVI procedure in aligned and misaligned commissural configurations under simulated hemodynamic rest and exercise conditions. The experimental design provided highly controllable and repeatable flow and pressure conditions. The left and right coronary mean flow did not differ significantly at pre- and post-VIV-TAVI procedure in any tested configurations. The commissural misalignment did not induce any significant alterations to the coronary flow. High-risk aortic root anatomy did not trigger coronary ostia obstruction or coronary flow alteration after transcatheter aortic valve implantation in a surgical bioprosthesis as shown from in-vitro flow loop tests.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Aorta, Thoracic; Heart Valve Prosthesis; Prosthesis Failure; Heart Valve Prosthesis Implantation; Perfusion; Coronary Occlusion; Bioprosthesis; Aortic Valve Stenosis; Prosthesis Design; Treatment Outcome
PubMed: 37097591
DOI: 10.1007/s12265-023-10364-y -
European Journal of Cardio-thoracic... Oct 2023Concomitant revascularization of coronary artery disease at the same time as treatment for aortic valvopathy favourably impacts survival. However, combined surgery may...
OBJECTIVES
Concomitant revascularization of coronary artery disease at the same time as treatment for aortic valvopathy favourably impacts survival. However, combined surgery may be associated with increased adverse outcomes compared to aortic valve replacement (AVR) or coronary artery bypass grafting in isolation.
METHODS
We retrospectively analyzed all patients who underwent AVR with bypass grafting between February 1996 and March 2019 using data from the National Adult Cardiac Surgery Audit. We used a generalized mixed-effects model to assess the effect of the number and type of bypass grafts associated with surgical AVR on in-hospital mortality, postoperative stroke, and the need for renal dialysis. Furthermore, we conducted an international cross-sectional survey of cardiac surgeons to explore their views about concomitant AVR with coronary bypass grafting interventions.
RESULTS
Fifty-one thousand two hundred and seventy-two patients were included in the study. Patients receiving 2 or more bypass grafts demonstrated more significant preoperative comorbidity and disease severity. Patients undergoing 2 and >2 grafts in addition to AVR had increased mortality as compared to patients undergoing AVR and only 1 graft [odds ratio (OR) 1.17, 95% confidence interval (CI) [1.05-1.30], P = 0.005 and OR 1.15, 95% CI [1.02-1.30], P = 0.024 respectively]. A single arterial conduit was associated with a reduction in mortality (OR 0.75, 95% CI [0.68-0.82], P < 0.001) and postoperative dialysis (OR 0.87, 95% CI [0.78-0.96], P = 0.006), but this association was lost with >1 arterial conduit. One hundred and three surgeons responded to our survey, with only a small majority believing that the number of bypass grafts can influence short- or long-term postoperative outcomes in these patients, and an almost equal split in responders supporting the use of staged or hybrid interventions for patients with concomitant pathology.
CONCLUSIONS
The number of grafts performed during combined AVR and coronary artery bypass grafting is associated with increased morbidity and mortality. The use of an arterial graft was also associated with reduced mortality. Future studies are needed to assess the effect of incomplete revascularization and measure long-term outcomes. Based on our data, current published evidence, and the collective expert opinion we gathered, we endorse future work to investigate the short and long-term efficacy and safety of hybrid intervention for patients with concomitant advanced coronary and aortic valve disease.
Topics: Adult; Humans; Aortic Valve; Retrospective Studies; Cross-Sectional Studies; Heart Valve Prosthesis Implantation; Treatment Outcome; Coronary Artery Bypass; Aortic Valve Stenosis; United Kingdom; Risk Factors; Postoperative Complications
PubMed: 37462523
DOI: 10.1093/ejcts/ezad259