-
Annals of Biomedical Engineering Nov 2023A common feature of congenital heart disease is the presence of right ventricular outflow tract (RVOT) obstruction that can range from mild to severe and can lead to... (Review)
Review
A common feature of congenital heart disease is the presence of right ventricular outflow tract (RVOT) obstruction that can range from mild to severe and can lead to atresia of the pulmonary valve, in extreme conditions. RVOT abnormalities can frequently be corrected surgically or via interventional means. However, most of these patients will ultimately develop pulmonary valve insufficiency and eventual right ventricular dilation, which will require a pulmonary valve replacement at some point in their life to mitigate the detrimental effects of pulmonary valve regurgitation (PVR) on the right ventricle (RV). The evolution from the studies done by Philip Bonhoeffer to implant a pulmonary valve via transcatheter means, have provided a bedrock for transcatheter pulmonary valve replacement (TPVR). Yet, several areas of unmet need for a demographic of patients still exist. Here, we discuss the clinical unmet needs in children under 20 Kg and expand the use of hybrid and other TPVR approaches along with the current indications and contraindications for pulmonary valve replacement. The constraints and limitations from commercially available pulmonary valves will be discussed from a clinical standpoint. Finally, we explore the use of hybrid and periventricular delivery of transcatheter pulmonary valves in younger patients.
Topics: Child; Humans; Pulmonary Valve; Heart Valve Prosthesis Implantation; Heart Valve Prosthesis; Prosthesis Design; Cardiac Catheterization; Treatment Outcome; Pulmonary Valve Insufficiency; Heart Defects, Congenital; Ventricular Outflow Obstruction, Right; Retrospective Studies
PubMed: 37543538
DOI: 10.1007/s10439-023-03328-5 -
Indian Heart Journal 2024There is conclusive evidence for relief of pulmonary valve obstruction immediately after balloon pulmonary valvuloplasty (BPV) and at follow-up. Development of... (Review)
Review
There is conclusive evidence for relief of pulmonary valve obstruction immediately after balloon pulmonary valvuloplasty (BPV) and at follow-up. Development of infundibular obstruction is seen in more severe PS cases and in older subjects. Reappearance of PS was observed in approximately 10 % of patients following BPV. The reasons for recurrence were found to be balloon/annulus ratio less than 1.2 and immediate post-BPV pulmonary valve peak gradients greater than 30 mmHg. Recurrent stenosis is successfully addressed by repeating BPV with lager balloons than used initially. Long-term results revealed continue relief of obstruction, but with development of pulmonary insufficiency, some patients requiring replacement of the pulmonary valve. It was concluded that BPV is the treatment of choice in the management valvar PS and that balloon/annuls ratio used for BPV should be lowered to 1.2 to 1.25. It was also suggested that strategies should be developed to prevent/reduce pulmonary insufficiency at long-term follow-up.
Topics: Humans; Balloon Valvuloplasty; Pulmonary Valve Stenosis; Pulmonary Valve; Treatment Outcome
PubMed: 38147974
DOI: 10.1016/j.ihj.2023.12.007 -
Frontiers in Cardiovascular Medicine 2023Despite numerous advantages of the Ross procedure, it presents a risk of late autograft and right ventricular outflow tract conduit failure. This study aimed to analyze...
BACKGROUND
Despite numerous advantages of the Ross procedure, it presents a risk of late autograft and right ventricular outflow tract conduit failure. This study aimed to analyze the outcomes of autograft dysfunction reoperations using autograft-sparing and root replacement techniques.
METHODS
Between 2015 and 2023, 49 patients underwent redo root surgery in our institution. Autograft valve-sparing procedures (VSP) were performed in 20 cases and the Bentall procedure (BP) in 29 patients. The short and long-term clinical outcomes along with echocardiographic results of VSP and BP were investigated.
RESULTS
Overall early mortality rate was 2.0% with no significant difference between the groups. Severe autograft valve insufficiency at the time of redo (OR 4.07, = 0.03) and patient age (OR 1.07, = 0.04) were associated with a valve replacement procedure instead of VSP. The median follow-up duration was 34 months. No late deaths occurred in either group. Freedom from VSP failure and aortic prosthesis dysfunction were 93.8% and 94.1% in the VSP and BP groups, respectively. No reoperations were necessary in either group.
CONCLUSION
Redo aortic root surgery can be safely performed in patients with autograft failure. Both root replacement and autograft valve-sparing procedures demonstrated acceptable results at mid-term follow-up. Early redo surgery pre-empting severe aortic insufficiency increases the likelihood of preservation of the dilated autograft valve.
PubMed: 38155981
DOI: 10.3389/fcvm.2023.1306445 -
Circulation. Cardiovascular Imaging Jul 2023Tricuspid regurgitation (TR) is common in chronic heart failure (HF) and is associated with negative prognosis. However, evidence on prognostic implications of TR in...
BACKGROUND
Tricuspid regurgitation (TR) is common in chronic heart failure (HF) and is associated with negative prognosis. However, evidence on prognostic implications of TR in acute HF is lacking. We sought to investigate the association between TR and mortality and the interaction with pulmonary hypertension (PH) in patients admitted for acute HF.
METHODS
We enrolled 1176 consecutive patients with a primary diagnosis of acute HF and with available noninvasive estimation of TR and pulmonary arterial systolic pressure.
RESULTS
Moderate-severe TR was present in 352 patients (29.9%) and was associated with older age and more comorbidities. The prevalence of PH (ie, pulmonary arterial systolic pressure >40 mm Hg), right ventricular dysfunction, and mitral regurgitation was higher in moderate-severe TR. At 1 year, 184 (15.6%) patients died. Moderate-severe TR was associated with higher 1-year mortality risk after adjustment for other echocardiographic parameters (pulmonary arterial systolic pressure, left ventricle ejection fraction, right ventricular dysfunction, mitral regurgitation, left and right atrial indexed volumes; hazard ratio, 1.718; =0.009), and the association with outcome was maintained when clinical variables (eg, natriuretic peptides, serum creatinine and urea, systolic blood pressure, atrial fibrillation) were added to the multivariable model (hazard ratio, 1.761; =0.024). The association between moderate-severe TR and outcome was consistent in patients with versus without PH, with versus without right ventricular dysfunction, and with versus without left ventricle ejection fraction <50%. Patients with coexistent moderate-severe TR and PH had 3-fold higher 1-year mortality risk compared with patients with no TR or PH (hazard ratio, 3.024; <0.001).
CONCLUSIONS
In patients hospitalized for acute HF, the severity of TR is associated with 1-year survival, regardless of the presence of PH. The coexistence of moderate-severe TR and estimated PH was associated with a further increase in mortality risk. Our data must be interpreted in the context of potential underestimation of pulmonary arterial systolic pressure in patients with severe TR.
Topics: Humans; Tricuspid Valve Insufficiency; Hypertension, Pulmonary; Mitral Valve Insufficiency; Ventricular Dysfunction, Right; Retrospective Studies; Heart Failure
PubMed: 37381900
DOI: 10.1161/CIRCIMAGING.122.014988 -
Multimedia Manual of Cardiothoracic... Nov 2023The Ross-Personalized External Aortic Root Support procedure is a surgical aortic valve replacement technique in which the autologous pulmonary valve is transposed in...
The Ross-Personalized External Aortic Root Support procedure is a surgical aortic valve replacement technique in which the autologous pulmonary valve is transposed in the aortic position to replace the malfunctioning aortic valve and a homograft is implanted in the pulmonary position. To prevent autograft dilatation, a Personalized External Aortic Root Support prosthesis is included in the proximal autograft anastomosis and wrapped around the ascending aorta. The aorta is transected transversely, the aortic valve is resected, and the coronary arteries are mobilized and cut out of the sinuses, leaving a rim. The pulmonary autograft is harvested by transecting the pulmonary artery and part of the right ventricular outflow tract. The autograft is approximated to the aortic root and inverted inside the ventricle. The proximal anastomosis is performed including the prosthesis between the aortic root and the autograft. The coronary buttons are threaded through appropriately positioned and sized holes in the prosthesis and reimplanted into the autograft. The ascending aorta is appropriately adapted and anastomosed with the distal autograft. When the patient is off cardiopulmonary bypass, the prosthesis can be closed longitudinally and is anchored to the distal aortic adventitia.
Topics: Humans; Autografts; Aorta, Thoracic; Transplantation, Autologous; Aortic Valve; Aorta; Aortic Valve Stenosis; Aortic Valve Insufficiency; Pulmonary Valve; Heart Valve Prosthesis Implantation; Reoperation
PubMed: 37942704
DOI: 10.1510/mmcts.2023.077 -
Journal of Cardiac Failure Sep 2023Right heart failure (RHF) is associated with a dismal prognosis in patients with pulmonary hypertension (PH). Exercise right heart catheterization may unmask right heart...
BACKGROUND
Right heart failure (RHF) is associated with a dismal prognosis in patients with pulmonary hypertension (PH). Exercise right heart catheterization may unmask right heart maladaptation as a sign of RHF. We sought to (1) define the normal limits of right atrial pressure (RAP) increase during exercise; (2) describe the right heart adaptation to exercise in PH owing to heart failure with preserved ejection fraction (PH-HFpEF) and in pulmonary arterial hypertension (PAH); and (3) identify the factors associated with right heart maladaptation during exercise.
METHODS AND RESULTS
We analyzed rest and exercise right heart catheterization from patients with PH-HFpEF and PAH. Right heart adaptation was described by absolute or cardiac output (CO)-normalized changes of RAP during exercise. Individuals with noncardiac dyspnea (NCD) served to define abnormal RAP responses (>97.5th percentile). Thirty patients with PH-HFpEF, 30 patients with PAH, and 21 patients with NCD were included. PH-HFpEF were older than PAH, with more cardiovascular comorbidities, and a higher prevalence of severe tricuspid regurgitation (P < .05). The upper limit of normal for peak RAP and RAP/CO slope in NCD were >12 mm Hg and ≥1.30 mm Hg/L/min, respectively. PH-HFpEF had higher peak RAP and RAP/CO slope than PAH (20 mm Hg [16-24 mm Hg] vs 12 mm Hg [9-19 mm Hg] and 3.47 mm Hg/L/min [2.02-6.19 mm Hg/L/min] vs 1.90 mm Hg/L/min [1.01-4.29 mm Hg/L/min], P < .05). A higher proportion of PH-HFpEF had RAP/CO slope and peak RAP above normal (P < .001). Estimated stressed blood volume at peak exercise was higher in PH-HFpEF than PAH (P < .05). In the whole PH cohort, the RAP/CO slope was associated with age, the rate of increase in estimated stressed blood volume during exercise, severe tricuspid regurgitation, and right atrial dilation.
CONCLUSIONS
Patients with PH-HFpEF display a steeper increase of RAP during exercise than those with PAH. Preload-mediated mechanisms may play a role in the development of exercise-induced RHF.
Topics: Humans; Hypertension, Pulmonary; Stroke Volume; Heart Failure; Tricuspid Valve Insufficiency; Noncommunicable Diseases; Hemodynamics; Cardiac Catheterization; Dyspnea; Exercise Test; Exercise Tolerance
PubMed: 37150503
DOI: 10.1016/j.cardfail.2023.04.009 -
JACC. Cardiovascular Interventions Aug 2023The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or... (Clinical Trial)
Clinical Trial
BACKGROUND
The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or surgically repaired right ventricular outflow tract (RVOT).
OBJECTIVES
One-year safety and effectiveness of the Harmony TPV were evaluated in patients from the Harmony Native Outflow Tract Early Feasibility Study, Harmony TPV Pivotal Study, and Continued Access Study, representing the largest cohort to date of Harmony TPV recipients.
METHODS
Eligible patients had severe PR by echocardiography or PR fraction ≥ 30% by cardiac magnetic resonance imaging and clinical indications for pulmonary valve replacement. The primary analysis included 87 patients who received a commercially available TPV22 (n = 42) or TPV25 (n = 45) device; 19 patients who received an early device iteration prior to its discontinuation were evaluated separately.
RESULTS
In the primary analysis, median patient age at treatment was 26 years (IQR: 18-37 years) in the TPV22 group and 29 years (IQR: 19-42 years) in the TPV25 group. At 1 year, there were no deaths; 98% of TPV22 and 91% of TPV25 patients were free from the composite of PR, stenosis, and reintervention (moderate or worse PR, mean RVOT gradient >40 mmHg, device-related RVOT reoperation, and catheter reintervention). Nonsustained ventricular tachycardia occurred in 16% of patients. Most patients had none/trace or mild PR (98% of TPV22 patients, 97% of TPV25 patients). Outcomes with the discontinued device are reported separately.
CONCLUSIONS
The Harmony TPV device demonstrated favorable clinical and hemodynamic outcomes across studies and valve types through 1 year. Further follow-up will continue to assess long-term valve performance and durability.
Topics: Humans; Cardiac Catheterization; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Prospective Studies; Pulmonary Valve; Pulmonary Valve Insufficiency; Treatment Outcome; Ventricular Outflow Obstruction
PubMed: 37278682
DOI: 10.1016/j.jcin.2023.03.002