Alternative Therapies in Health and... Jan 2024In China, there have been instances of sudden cardiac death among university students, with a significant number of students being at risk of cardiovascular diseases....
BACKGROUND
In China, there have been instances of sudden cardiac death among university students, with a significant number of students being at risk of cardiovascular diseases. This risk is often attributed to sub-health conditions such as weight gain and obesity, which are triggered by sedentary lifestyles, irregular living habits, and unregulated diets. Therefore, it is crucial to enhance the guidance for participation in physical activities, encouraging students to actively reduce their risk of cardiovascular diseases (CVD). Jogging, characterized by its convenience, simplicity, and low-risk participation, has been widely accepted by university students. This study takes the impact of jogging on the cardiovascular function of university students as a starting point. It aims to explore the content of the changing process suitable for the development of cardiovascular function in university students. The ultimate goal is to promote the healthy development of the cardiovascular system function in university students and improve their adherence to physical activities.
METHODS
The study recruited 60 university students with no exercise habits through on-campus poster advertisements. These 60 participants were randomly divided into two groups. The students in the experimental group were required to jog no less than three times a week, with each session lasting at least 30 minutes. The organizers of the experiment would remind the students daily in a WeChat group to complete their weekly exercise plan and persist in jogging, promoting the benefits of this activity. During jogging, the students used the Keep mobile application to record their jogging time and heart rate, which they then uploaded to the WeChat group. Follow-ups were conducted with students who did not complete their exercise plan, providing encouragement and guidance to continue participating in the experiment. The study employed a comparative research approach between the experimental group and the control group.
RESULTS
According to the experimental protocol, after 12 weeks of jogging intervention, the cardiovascular health indicators of both male and female students in the experimental group showed positive changes. Measurements of cardiac function indicators in the experimental group of boys SPTI, DPTI, ED has decreased, SEVR has increased, the relevant indicators compared with the relevant indicators of the control group (P < .05) is significant; in the experimental group of girls, SPTI, DPTI, SEVR indicators decreased, ED increased, and compared with the relevant indicators of the control group (P < .01) has a very significant significance. Changes in vascular indicators in the experimental and control groups after the experiment, SBP, DBP, PP, CAP decreased in the experimental group, and DBP, CAP in the male and female groups were found to be (P < .01), with highly significant changes; while SBP, PP intergroup comparison (P < .05), with significant changes.
CONCLUSION
Jogging is a good aerobic exercise program characterized by convenient ways of carrying out simple methods and low risk of participation. The benefits of jogging are not only reflected physiologically but also psychologically; it can make participants enhance their self-confidence and make their moods more pleasant. It can also improve sleep quality and maintain a good mental state. Long-term jogging habits can effectively improve endothelial function and heart contraction function, reduce blood pressure effectively prevent atherosclerosis and prevent CVD by reducing the incidence of CVD risk factors.
PubMed: 38290441
DOI: No ID Found -
Communications Medicine Feb 2024Long-term monitoring of Electrocardiogram (ECG) recordings is crucial to diagnose arrhythmias. Clinicians can find it challenging to diagnose arrhythmias, and this is a...
BACKGROUND
Long-term monitoring of Electrocardiogram (ECG) recordings is crucial to diagnose arrhythmias. Clinicians can find it challenging to diagnose arrhythmias, and this is a particular issue in more remote and underdeveloped areas. The development of digital ECG and AI methods could assist clinicians who need to diagnose arrhythmias outside of the hospital setting.
METHODS
We constructed a large-scale Chinese ECG benchmark dataset using data from 272,753 patients collected from January 2017 to December 2021. The dataset contains ECG recordings from all common arrhythmias present in the Chinese population. Several experienced cardiologists from Shanghai First People's Hospital labeled the dataset. We then developed a deep learning-based multi-label interpretable diagnostic model from the ECG recordings. We utilized Accuracy, F1 score and AUC-ROC to compare the performance of our model with that of the cardiologists, as well as with six comparison models, using testing and hidden data sets.
RESULTS
The results show that our approach achieves an F1 score of 83.51%, an average AUC ROC score of 0.977, and 93.74% mean accuracy for 6 common arrhythmias. Results from the hidden dataset demonstrate the performance of our approach exceeds that of cardiologists. Our approach also highlights the diagnostic process.
CONCLUSIONS
Our diagnosis system has superior diagnostic performance over that of clinicians. It also has the potential to help clinicians rapidly identify abnormal regions on ECG recordings, thus improving efficiency and accuracy of clinical ECG diagnosis in China. This approach could therefore potentially improve the productivity of out-of-hospital ECG diagnosis and provides a promising prospect for telemedicine.
PubMed: 38418628
DOI: 10.1038/s43856-024-00464-4 -
Diagnostics (Basel, Switzerland) Sep 2023A 36-year-old professional marathon runner reported sudden irregular palpitations occurring during competitions, with heart rates (HR) up to 230 bpm recorded on a sports...
A 36-year-old professional marathon runner reported sudden irregular palpitations occurring during competitions, with heart rates (HR) up to 230 bpm recorded on a sports HR monitor (HRM) over 4 years. These episodes subsided upon the cessation of exercise. Electrocardiograms, echocardiography, and cardiac magnetic resonance imaging results were borderline for athlete's heart. Because an electrophysiology study and standard exercise tests provoked no arrhythmia, doctors suspected Munchausen syndrome. Ultimately, an exercise test that simulated the physical effort of a competition provoked tachyarrhythmia consistent with the HRM readings. This case demonstrates the diagnostic difficulties related to exercise-induced arrhythmia and the diagnostic usefulness of sports HRMs.
PubMed: 37761288
DOI: 10.3390/diagnostics13182917 -
Materials (Basel, Switzerland) Aug 2023Commonly used tool materials for machining wood-based materials are WC-Co carbides. Although they have been known for a long time, there is still much development in the...
Commonly used tool materials for machining wood-based materials are WC-Co carbides. Although they have been known for a long time, there is still much development in the field of sintered tool materials, especially WC-Co carbides and superhard materials. The use of new manufacturing methods (such as FAST-field-assisted sintering technology), which use pulses of electric current for heating, can improve the properties of the materials used for cutting tools, thereby increasing the cost-effectiveness of machining. The ability to increase tool life without the downtime associated with tool wear allows significant cost savings, particularly in mass production. This paper presents the results of a study of the effect of grain size and cobalt content of carbide tool sinters on the tribological properties of the materials studied. The powders used for consolidation were characterised by irregular shape and formed agglomerates of different sizes. Tribological tests were carried out using the T-01 (ball-on-disc) method. In order to determine the wear kinetics, the entire friction path was divided into 15 cycles of 200 m and the weight loss was measured after each stage. In order to determine the mechanism and intensity of wear of the tested materials under technically dry friction conditions, the surface of the tested sinters was observed before the test and after 5, 10, and 15 cycles. The conclusions of the study indicate that the predominant effect of surface cooperation at the friction node is abrasion due to the material chipping that occurs during the process. The results confirm the influence of sintered grain size and cobalt content on durability. In the context of the application of the materials in question for cutting tools, it can be pointed out that sintered WC(0.4)_4 has the highest potential for use in the manufacture of cutting tools.
PubMed: 37687529
DOI: 10.3390/ma16175836 -
The British Journal of Ophthalmology Oct 2023Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically...
BACKGROUND
Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing.
METHODS
Eleven patients with primary open-angle glaucoma (POAG) previously implanted with a telemetric IOP sensor (Eyemate-IO) were instructed to look straight ahead for 1 min as a baseline measurement. Next, 6 repeats of blinking on instruction with 10 s intervals in between were performed. In addition, 5 repeats of eyelid closure (n=9), eyelid squeezing and eyelid rubbing (n=7) were performed with 15 s intervals in between. IOP was recorded via an external antenna placed around the study eye. Average peak IOP increases from baseline were analysed and tested against zero (no change) with one-sample t-tests.
RESULTS
For eyelid rubbing, the average peak ∆ IOP increase (mean±SEM) was 59.1±9.6 mm Hg (p<0.001) from baseline. It was 42.2±5.8 mm Hg (p<0.0001) for eyelid squeezing, 3.8±0.6 mm Hg (n=9, p<0.01) for eyelid closure and 11.6±2.4 mm Hg (p<0.001) for voluntary blinking. No IOP change except for a short irregularity in the ocular pulse was observed during involuntary blinking.
CONCLUSION
Eyelid manoeuvres in patients with POAG elicited brief increases in IOP that were particularly large with squeezing and rubbing. Further investigation of the potential implications for glaucoma progression is warranted.
Topics: Humans; Intraocular Pressure; Glaucoma, Open-Angle; Tonometry, Ocular; Glaucoma; Eyelids; Oculomotor Muscles
PubMed: 35701079
DOI: 10.1136/bjophthalmol-2021-320508 -
Translational Vision Science &... Sep 2023To evaluate the efficacy of topical losartan after blast injury-simulating irregular phototherapeutic keratectomy (PTK) in rabbits.
PURPOSE
To evaluate the efficacy of topical losartan after blast injury-simulating irregular phototherapeutic keratectomy (PTK) in rabbits.
METHODS
Twelve NZW rabbits underwent 100 pulse 6.5 mm diameter PTK over a metal screen to generate severe surface irregularity and inhibit epithelial basement membrane regeneration. Corneas were treated with 0.8 mg/mL losartan in balanced salt solution (BSS) or BSS 50 µL six times per day for six weeks after PTK. All corneas had slit lamp photography, with and without 1% fluorescein at two, four, and six weeks after PTK, and were analyzed using immunohistochemistry for the myofibroblast marker α-smooth muscle actin (α-SMA), keratocyte marker keratocan, mesenchymal cell marker vimentin, transforming growth factor (TGF)-β1, and collagen type IV.
RESULTS
Topical 0.8 mg/mL losartan six times a day significantly decreased anterior stromal α-SMA intensity units compared to BSS at six weeks after anterior stromal irregularity-inducing screened PTK (P = 0.009). Central corneal opacity, however, was not significantly different between the two groups. Keratocan, vimentin, TGF-β1, or collagen type IV levels in the anterior stroma were not significantly different between the two groups.
CONCLUSIONS
Topical losartan effectively decreased myofibroblast generation after surface blast simulation irregular PTK. However, these results suggest initial masking-smoothing PTK, along with adjuvant topical losartan therapy, may be needed to decrease corneal stromal opacity after traumatic injuries that produce severe surface irregularity.
TRANSLATIONAL RELEVANCE
Topical losartan decreased scar-producing stromal myofibroblasts after irregular PTK over a metal screen but early smoothing of irregularity would also likely be needed to significantly decrease corneal opacity.
Topics: Rabbits; Animals; Losartan; Myofibroblasts; Vimentin; Collagen Type IV; Corneal Opacity
PubMed: 37750746
DOI: 10.1167/tvst.12.9.20 -
Frontiers in Physiology 2023In atrial fibrillation (AF), the ECG P-wave, which represents atrial depolarization, is replaced with chaotic and irregular fibrillation waves (f waves). The f-wave...
In atrial fibrillation (AF), the ECG P-wave, which represents atrial depolarization, is replaced with chaotic and irregular fibrillation waves (f waves). The f-wave frequency, , shows significant variations over time. Cardiorespiratory interactions regulated by the autonomic nervous system have been suggested to play a role in such variations. We conducted a simulation study to test whether the spatiotemporal release pattern of the parasympathetic neurotransmitter acetylcholine (ACh) modulates the frequency of atrial reentrant circuits. Understanding parasympathetic involvement in AF may guide more effective treatment approaches and could help to design autonomic markers alternative to heart rate variability (HRV), which is not available in AF patients. 2D tissue and 3D whole-atria models of human atrial electrophysiology in persistent AF were built. Different ACh release percentages (8% and 30%) and spatial ACh release patterns, including spatially random release and release from ganglionated plexi (GPs) and associated nerves, were considered. The temporal pattern of ACh release, ACh(), was simulated following a sinusoidal waveform of frequency 0.125 Hz to represent the respiratory frequency. Different mean concentrations and peak-to-peak ranges of ACh (ΔACh) were tested. We found that temporal variations in , (), followed the simulated temporal ACh() pattern in all cases. The temporal mean of (), , depended on the fibrillatory pattern (number and location of rotors), the percentage of ACh release nodes and . The magnitude of () modulation, Δ , depended on the percentage of ACh release nodes and ΔACh. The spatial pattern of ACh release did not have an impact on and only a mild impact on Δ . The f-wave frequency, being indicative of vagal activity, has the potential to drive autonomic-based therapeutic actions and could replace HRV markers not quantifiable from AF patients.
PubMed: 38235381
DOI: 10.3389/fphys.2023.1189464 -
Nanomaterials (Basel, Switzerland) Mar 2024Multi-exciton generation by multi-photon absorption under low-energy photons can be thought a reasonable method to reduce the risk of optical damage, especially in...
Multi-exciton generation by multi-photon absorption under low-energy photons can be thought a reasonable method to reduce the risk of optical damage, especially in photoelectric quantum dot (QD) devices. The lifetime of the multi-exciton state plays a key role in the utilization of photon-induced carriers, which depends on the dynamics of the exciton generation process in materials. In this paper, the exciton generation dynamics of the photon absorption under low-frequency light in CdSe QDs are successfully detected and studied by the temporal resolution transient absorption (TA) spectroscopy method. Since the cooling time of hot excitons extends while the rate of auger recombination is accelerated when incident energy is increased, the filling time of defect states is irregular, and exciton generation experiences a transition from single-photon absorption to multi-photon absorption. This result shows how to change the excitation. Optical parameters can prolong the lifetime of excitons, thus fully extracting excitons and improving the photoelectric conversion efficiency of QD optoelectronic devices, which provides theoretical and experimental support for the development of QD optoelectronic devices.
PubMed: 38607093
DOI: 10.3390/nano14070558 -
Heliyon Mar 2024This work analyzes hemodynamic phenomena within the aorta of two elderly patients and their impact on blood flow behavior, particularly affected by an endovascular...
This work analyzes hemodynamic phenomena within the aorta of two elderly patients and their impact on blood flow behavior, particularly affected by an endovascular prosthesis in one of them (Patient II). Computational Fluid Dynamics (CFD) was utilized for this study, involving measurements of velocity, pressure, and wall shear stress (WSS) at various time points during the third cardiac cycle, at specific positions within two cross sections of the thoracic aorta. The first cross-section (Cross-Section 1, CS1) is located before the initial fluid bifurcation, just before the right subclavian artery. The second cross-section (Cross-Section 2, CS2) is situated immediately after the left subclavian artery. The results reveal that, under regular aortic geometries, velocity and pressure magnitudes follow the principles of fluid dynamics, displaying variations. However, in Patient II, an endoprosthesis near the CS2 and the proximal border of the endoprosthesis significantly disrupts fluid behavior owing to the pulsatile flow. The cross-sectional areas of Patient I are smaller than those of Patient II, leading to higher flow magnitudes. Although in CS1 of Patient I, there is considerable variability in velocity magnitudes, they exhibit a more uniform and predictable transition. In contrast, CS2 of Patient II, where magnitude variation is also high, displays irregular fluid behavior due to the endoprosthesis presence. This cross-section coincides with the border of the fluid bifurcation. Additionally, the irregular geometry caused by endovascular aneurysm repair contributes to flow disruption as the endoprosthesis adjusts to the endothelium, reshaping itself to conform with the vessel wall. In this context, significant alterations in velocity values, pressure differentials fluctuating by up to 10%, and low wall shear stress indicate the pronounced influence of the endovascular prosthesis on blood flow behavior. These flow disturbances, when compounded by the heart rate, can potentially lead to changes in vascular anatomy and displacement, resulting in a disruption of the prosthesis-endothelium continuity and thereby causing clinical complications in the patient.
PubMed: 38434340
DOI: 10.1016/j.heliyon.2024.e26355 -
American Heart Journal May 2024Atrial fibrillation (AF) increases the risk of death, stroke, heart failure, cognitive decline, and healthcare costs but is often asymptomatic and undiagnosed. There is... (Observational Study)
Observational Study
BACKGROUND
Atrial fibrillation (AF) increases the risk of death, stroke, heart failure, cognitive decline, and healthcare costs but is often asymptomatic and undiagnosed. There is currently no national screening program for AF. The advent of validated hand-held devices allows AF to be detected in non-healthcare settings, enabling screening to be undertaken within the community.
METHOD AND RESULTS
In this novel observational study, we embedded a MyDiagnostick single lead ECG sensor into the handles of shopping trolleys in four supermarkets in the Northwest of England: 2155 participants were recruited. Of these, 231 participants either activated the sensor or had an irregular pulse, suggesting AF. Some participants agreed to use the sensor but refused to provide their contact details, or consent to pulse assessment. In addition, some data were missing, resulting in 203 participants being included in the final analyses. Fifty-nine participants (mean age 73.6 years, 43% female) were confirmed or suspected of having AF; 20 were known to have AF and 39 were previously undiagnosed. There was no evidence of AF in 115 participants and the remaining 46 recordings were non-diagnostic, mainly due to artefact. Men and older participants were significantly more likely to have newly diagnosed AF. Due to the number of non-diagnostic ECGs (n = 46), we completed three levels of analyses, excluding all non-diagnostic ECGs, assuming all non-diagnostic ECGs were masking AF, and assuming all non-diagnostic ECGs were not AF. Based on the results of the three analyses, the sensor's sensitivity (95% CI) ranged from 0.70 to 0.93; specificity from 0.15 to 0.97; positive predictive values (PPV) and negative predictive values (NPV) ranged from 0.24 to 0.56 and 0.55 to 1.00, respectively. These values should be interpreted with caution, as the ideal reference standard on 1934 participants was imperfect.
CONCLUSION
The study demonstrates that the public will engage with AF screening undertaken as part of their daily routines using hand-held devices. Sensors can play a key role in identifying asymptomatic patients in this way, but the technology must be further developed to reduce the quantity of non-diagnostic ECGs.
Topics: Humans; Atrial Fibrillation; Male; Female; Feasibility Studies; Aged; Electrocardiography; Mass Screening; England; Middle Aged; Aged, 80 and over
PubMed: 38395294
DOI: 10.1016/j.ahj.2024.02.011