BMC Medical Imaging Nov 2023The purpose of this study was to investigate the utility of contrast-enhanced ultrasound (CEUS) in percutaneous renal space-occupying lesion puncture biopsy.
OBJECTIVE
The purpose of this study was to investigate the utility of contrast-enhanced ultrasound (CEUS) in percutaneous renal space-occupying lesion puncture biopsy.
METHODS
Ultrasound (US)-guided percutaneous needle biopsies were performed on 55 patients with renal space-occupying lesions, and the results were analyzed retrospectively. The US group included 36 patients receiving conventional US, and the contrast-enhanced ultrasound (CEUS) group included 22 patients, including 19 patients receiving CEUS directly and 3 patients receiving additional enhanced ultrasound due to the first conventional ultrasound puncture failure. The relevant data were subjected to statistical analysis.
RESULTS
The results of this study showed that the successful rate of obtaining effective tissue (100% vs. 75%) and the puncture accuracy (100% vs. 88.89%) in CEUS group were significantly higher than those in US group (P < 0.05). CEUS-guided puncture biopsy of renal mass, especially in the case of urothelial carcinoma of the renal pelvis, outperforms conventional ultrasound, and the difference was statistically significant (P < 0.05).
CONCLUSION
Percutaneous renal space-occupying lesion puncture biopsies aided by CEUS yield more effective tissue and improved puncture accuracy.
Topics: Humans; Retrospective Studies; Carcinoma, Transitional Cell; Contrast Media; Urinary Bladder Neoplasms; Biopsy, Needle; Ultrasonography; Punctures; Biopsy
PubMed: 37940851
DOI: 10.1186/s12880-023-01137-9 -
The Lancet. Microbe Apr 2024Post-mortem examinations continue to play a crucial role in understanding the epidemiology and pathogenesis of infectious diseases. However, the perceived infection risk... (Review)
Review
Post-mortem examinations continue to play a crucial role in understanding the epidemiology and pathogenesis of infectious diseases. However, the perceived infection risk can preclude traditional, invasive, complete diagnostic autopsy. Post-mortem examination is especially important in emerging infectious diseases with potentially unknown infection risks, but rapid acquisition of good quality tissue samples is needed as part of the scientific and public health response. Needle biopsy post-mortem is a minimally invasive, rapid, closed-body autopsy technique that was originally developed to minimise the infection risk to practitioners. Since its inception, needle biopsy post-mortem has also been used as a technique to support complete diagnostic autopsy provision in poorly resourced regions and to facilitate post-mortem examinations in communities that might have religious or cultural objections to an invasive autopsy. This Review analyses the evolution and applicability of needle biopsy post-mortem in investigating endemic and emerging infectious diseases.
PubMed: 38604206
DOI: 10.1016/S2666-5247(24)00044-2 -
Pulmonology Jan 2024Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the standard approach for lung cancer staging. However, its diagnostic utility for other...
INTRODUCTION
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the standard approach for lung cancer staging. However, its diagnostic utility for other mediastinal diseases might be hampered by the limited tissue retrieved. Recent evidence suggests the novel sampling strategies of forceps biopsy and cryobiopsy as auxiliary techniques to EBUS-TBNA, considering their capacity for larger diagnostic samples.
METHODS
This study determined the added value of forceps biopsy and cryobiopsy for the diagnosis of mediastinal diseases. Consecutive patients with mediastinal lesions of 1 cm or more in the short axis were enrolled. Following completion of needle aspiration, three forceps biopsies and one cryobiopsy were performed in a randomised pattern. Primary endpoints included diagnostic yield defined as the percentage of patients for whom mediastinal biopsy led to a definite diagnosis, and procedure-related complications.
RESULTS
In total, 155 patients were recruited and randomly assigned. Supplementing EBUS-TBNA with either forceps biopsy or cryobiopsy increased diagnostic yield, with no significant difference between EBUS-TBNA plus forceps biopsy and EBUS-TBNA plus cryobiopsy (85.7 % versus 91.6 %, P = 0.106). Yet, samples obtained by additional cryobiopsies were more qualified for lung cancer molecular testing than those from forceps biopsies (100.0 % versus 89.5 %, P = 0.036). When compared directly, the overall diagnostic yield of cryobiopsy was superior to forceps biopsy (85.7 % versus 70.8 %, P = 0.001). Cryobiopsies produced greater samples in shorter procedural time than forceps biopsies. Two (1.3 %) cases of postprocedural pneumothorax were detected.
CONCLUSIONS
Transbronchial mediastinal cryobiopsy might be a promising complementary tool to supplement traditional needle biopsy for increased diagnostic yield and tissue harvesting.
TRIAL REGISTRATION
ChiCTR2000030373.
PubMed: 38182469
DOI: 10.1016/j.pulmoe.2023.12.002 -
Heliyon Feb 2024Percutaneous needle insertion is a minimally invasive surgery with broad medical application prospects, such as biopsy and brachytherapy. However, the currently adopted... (Review)
Review
Percutaneous needle insertion is a minimally invasive surgery with broad medical application prospects, such as biopsy and brachytherapy. However, the currently adopted rigid needles have limitations, as they cannot bypass obstacles or correct puncture deviations and can only travel along a straight path. Bevel-tip flexible needles are increasingly being adopted to address these issues, owing to their needle body's ease of deformation and bending. Successful puncture of flexible needles relies on accurate models and path planning, ensuring the needle reaches the target while avoiding vital tissues. This review investigates puncture models and path-planning algorithms by reviewing recent literature, focusing on the path-planning part. According to the literature, puncture models can be divided into three types: mechanical, finite element method (FEM), and kinematic models, while path-planning algorithms are categorized and discussed following the division used for mobile robots, which differs from the conventional approach for flexible needles-an innovation in this review. This review systematically summarizes the following categories: graph theory search, sampling-based, intelligent search, local obstacle avoidance, and other algorithms, including their implementation, advantages, and disadvantages, to further explore the potential to overcome obstacles in path planning for minimally invasive puncture needles. Finally, this study proposes future development trends in path-planning algorithms, providing possible directions for subsequent research for bevel-tipped flexible needles. This research aims to provide a resource for researchers to quickly learn about common path-planning algorithms, their backgrounds, and puncture models.
PubMed: 38322890
DOI: 10.1016/j.heliyon.2024.e25002 -
Current Oncology (Toronto, Ont.) Feb 2024Biopsy is a pivotal component in the diagnostic process of bone and soft tissue tumors. The objective is to obtain adequate tissue without compromising local tumor... (Review)
Review
Biopsy is a pivotal component in the diagnostic process of bone and soft tissue tumors. The objective is to obtain adequate tissue without compromising local tumor dissemination and the patient's survival. This review explores contemporary principles and practices in musculoskeletal biopsies, emphasizing the critical role of diagnostic accuracy while also delving into the evolving landscape of liquid biopsies as a promising alternative in the field. A thorough literature search was done in PubMed and Google Scholar as well as in physical books in libraries to summarize the available biopsy techniques for musculoskeletal tumors, discuss the available methods, risk factors, and complications, and to emphasize the challenges related to biopsies in oncology. Research articles that studied the basic principles and specialized techniques of biopsy techniques in tumor patients were deemed eligible. Their advantages and disadvantages, technical and pathophysiological mechanisms, and possible risks and complications were reviewed, summarized, and discussed. An inadequately executed biopsy may hinder diagnosis and subsequently impact treatment outcomes. All lesions should be approached with a presumption of malignancy until proven otherwise. Liquid biopsies have emerged as a potent non-invasive tool for analyzing tumor phenotype, progression, and drug resistance and guiding treatment decisions in bone sarcomas and metastases. Despite advancements, several barriers remain in biopsies, including challenges related to costs, scalability, reproducibility, and isolation methods. It is paramount that orthopedic oncologists work together with radiologists and pathologists to enhance diagnosis, patient outcomes, and healthcare costs.
Topics: Humans; Biopsy, Needle; Reproducibility of Results; Bone Neoplasms; Biopsy; Soft Tissue Neoplasms; Musculoskeletal Diseases
PubMed: 38392061
DOI: 10.3390/curroncol31020067 -
Respirology (Carlton, Vic.) Oct 2023Needle-based confocal laser endomicroscopy (nCLE) allows real-time microscopic imaging at the needle tip. nCLE malignancy criteria are used for tool-in-lesion...
BACKGROUND AND OBJECTIVE
Needle-based confocal laser endomicroscopy (nCLE) allows real-time microscopic imaging at the needle tip. nCLE malignancy criteria are used for tool-in-lesion confirmation during bronchoscopic lung nodule analysis. However, to date, nCLE criteria for granulomas are lacking. The aim was to identify and validate nCLE granuloma criteria and assess if blinded raters can distinguish malignant from granulomatous nCLE videos.
METHODS
In patients with suspected sarcoidosis, nCLE-imaging of mediastinal lymph nodes was performed during endoscopic ultrasound procedures, followed by needle aspiration. nCLE granuloma criteria were identified by comparison with pathology and final diagnoses. Additionally, nCLE-videos of granulomatous lung nodules part of prospective trials and clinical care were compared to the proposed nCLE granuloma criteria. Blinded raters validated nCLE videos of sarcoid and reactive mediastinal lymph nodes and malignant and granulomatous lung nodules twice.
RESULTS
Granuloma criteria were identified (brighter-toned, homogeneous and well-demarcated lesions) based on nCLE-imaging in 14 sarcoidosis patients. Raters evaluated 26 nCLE-videos obtained in lymph nodes (n = 15 sarcoidosis; n = 11 reactive and total of 260 ratings). Granuloma criteria were recognized with 88% accuracy. The inter-observer (κ = 0.63, 95% CI 0.54-0.72) and intra-observer reliability (κ = 0.70 ± 0.06) were substantial. Based on 12 nCLE-videos obtained in lung nodules (n = 4 granulomas, n = 6 malignancy, n = 2 malignancy + granulomas and total of 120 ratings) granuloma and malignancy criteria were recognized with 92% and 75% accuracy.
CONCLUSION
nCLE imaging facilitates real-time granuloma visualization. Blinded raters accurately and consistently recognized granulomas on nCLE-imaging and distinguished nCLE granuloma criteria from malignancy. Our data show the potential of nCLE as a real-time bronchoscopic guidance tool for lung nodule analysis.
Topics: Humans; Prospective Studies; Reproducibility of Results; Microscopy, Confocal; Granuloma; Sarcoidosis; Lasers; Endoscopic Ultrasound-Guided Fine Needle Aspiration
PubMed: 37562791
DOI: 10.1111/resp.14542 -
Frontiers in Oncology 2023Accurate pathologic diagnosis and molecular classification of breast mass biopsy tissue is important for determining individualized therapy for (neo)adjuvant systemic...
Accurate pathologic diagnosis and molecular classification of breast mass biopsy tissue is important for determining individualized therapy for (neo)adjuvant systemic therapies for invasive breast cancer. The CassiII rotational core biopsy system is a novel biopsy technique with a guide needle and a "stick-freeze" technology. The comprehensive assessments including the concordance rates of diagnosis and biomarker status between CassiII and core needle biopsy were evaluated in this study. Estrogen receptor (ER), progesterone receptor (PgR), human epidermal growth factor receptor 2 (HER2), and Ki67 were analyzed through immunohistochemistry. In total, 655 patients with breast cancer who underwent surgery after biopsy at Sir Run Run Shaw Hospital between January 2019 to December 2021 were evaluated. The concordance rates (CRs) of malignant surgical specimens with CassiII needle biopsy was significantly high compared with core needle biopsy. Moreover, CassiII needle biopsy had about 20% improvement in sensitivity and about 5% improvement in positive predictive value compared to Core needle biopsy. The characteristics including age and tumor size were identified the risk factors for pathological inconsistencies with core needle biopsies. However, CassiII needle biopsy was associated with tumor diameter only. The CRs of ER, PgR, HER2, and Ki67 using Cassi needle were 98.08% (kappa, 0.941; p<.001), 90.77% (kappa, 0.812; p<.001), 69.62% (kappa, 0.482; p<.001), and 86.92% (kappa, 0.552; p<.001), respectively. Post-biopsy complications with CassiII needle biopsy were also collected. The complications of CassiII needle biopsy including chest stuffiness, pain and subcutaneous ecchymosis are not rare. The underlying mechanism of subcutaneous congestion or hematoma after CassiII needle biopsy might be the larger needle diameter and the effect of temperature on coagulation function. In summary, CassiII needle biopsy is age-independent and has a better accuracy than CNB for distinguishing carcinoma and invasive carcinoma.
PubMed: 37823052
DOI: 10.3389/fonc.2023.1067246 -
Cell Reports. Medicine Oct 2023Patients with early-stage HER2-overexpressing breast cancer struggle with treatment resistance in 20%-40% of cases. More information is needed to predict HER2 therapy...
Patients with early-stage HER2-overexpressing breast cancer struggle with treatment resistance in 20%-40% of cases. More information is needed to predict HER2 therapy response and resistance in vivo. In this study, we perform (phospho)proteomics analysis of pre-treatment HER2 needle biopsies of early-stage invasive breast cancer to identify molecular signatures predictive of treatment response to trastuzumab, pertuzumab, and chemotherapy. Our data show that accurate quantification of the estrogen receptor (ER) and HER2 biomarkers, combined with the assessment of associated biological features, has the potential to enable better treatment outcome prediction. In addition, we identify cellular mechanisms that potentially precondition tumors to resist therapy. We find proteins with expression changes that correlate with resistance and constitute to a strong predictive signature for treatment success in our patient cohort. Our results highlight the multifactorial nature of drug resistance in vivo and demonstrate the necessity of deep tumor profiling.
Topics: Humans; Female; Breast Neoplasms; Receptor, ErbB-2; Proteomics; Biomarkers, Tumor; Neoadjuvant Therapy; Biopsy, Needle
PubMed: 37794585
DOI: 10.1016/j.xcrm.2023.101203 -
Cancer Imaging : the Official... Oct 2023To compare the genomic testing based on specimens obtained from percutaneous core-needle biopsy (CNB) before and immediately after coaxial microwave ablation (MWA) in...
Percutaneous core-needle biopsy before and immediately after coaxial microwave ablation in solid non-small cell lung cancer: the comparison of genomic testing from specimens.
PURPOSE
To compare the genomic testing based on specimens obtained from percutaneous core-needle biopsy (CNB) before and immediately after coaxial microwave ablation (MWA) in solid non-small cell lung cancer (NSCLC), and to investigate the diagnostic performance of CNB immediately after coaxial MWA in solid NSCLC.
METHODS
Coaxial MWA and CNB were performed for NSCLC patients, with a power of 30 or 40 watts (W) in MWA between the pre- and post-ablation CNB, followed by continuous ablation after the second CNB on demand. The paired specimens derived from the same patient were compared for pathological diagnosis and genomic testing. DNA/RNA extracted from the paired specimens were also compared.
RESULTS
A total of 33 NSCLC patients with solid lesions were included. There were two patients (6.1%) without atypical cells and three patients (9.1%) who had the technical failure of genomic testing in post-ablation CNB. The concordance rate of pathological diagnosis between the twice CNB was 93.9% (kappa = 0.852), while that of genomic testing was 90.9% (kappa = 0.891). For the comparisons of DNA/RNA extracted from pre- and post-ablation CNB in 30 patients, no significant difference was found when the MWA between twice CNB has a power of 30 or 40 W and ablation time within five minutes (P = 0.174).
CONCLUSIONS
If the pre-ablation CNB presented with a high risk of pneumothorax or hemorrhage, the post-ablation CNB could be performed to achieve accurate pathological diagnosis and genomic testing and the maximum effect of ablation, which might allow for the diagnosis of genomic testing in 90.9% of solid NSCLC.
Topics: Humans; Carcinoma, Non-Small-Cell Lung; Lung Neoplasms; Microwaves; Biopsy, Large-Core Needle; Genetic Testing; DNA; RNA; Retrospective Studies
PubMed: 37789413
DOI: 10.1186/s40644-023-00610-6 -
Ultrasound in Medicine & Biology Jan 2024Endobronchial ultrasound (EBUS) is commonly used to guide transbronchial needle biopsies for the staging of lymph nodes in non-small cell lung cancer patients. Although...
OBJECTIVE
Endobronchial ultrasound (EBUS) is commonly used to guide transbronchial needle biopsies for the staging of lymph nodes in non-small cell lung cancer patients. Although contrast-enhanced ultrasound (CEUS) and microbubbles (MBs) can improve the diagnostic accuracy in tumors, the ability of contrast-enhanced EBUS (CE-EBUS) to image MBs has not yet been comprehensively evaluated. In this study, we assessed the ability of a CE-EBUS system (Olympus EU-ME2 PREMIER and BF-UC180F bronchoscope) to detect laboratory-synthesized MBs in comparison to clinical (Toshiba Aplio SSA-790A) and pre-clinical (VisualSonics Vevo 2100) CEUS systems in vitro and in vivo, respectively.
METHODS
Agar flow phantoms and reference tissue were used to assess CE-EBUS MB imaging in vitro, and A549 tumor-bearing athymic nude and AE17-OVA tumor-bearing C57BL/6 mice were used to assess MB detectability and perfusion in vivo, respectively.
RESULTS
Results revealed that despite the lower sensitivity of CE-EBUS to MB concentration in comparison to clinical CEUS, CE-EBUS yielded a similar contrast-to-tissue ratio (CTR) in vitro of 28.9 ± 4.5 dB for CE-EBUS, compared with 29.7 ± 2.6 dB for clinical CEUS (p < 0.05). In vivo, CE-EBUS generated a perfusion curve highly correlated with that obtained with the pre-clinical CEUS system (Pearson correlation coefficient = 0.927, p < 0.05). Moreover, CE-EBUS yielded a CTR 2.7 times higher than that obtained with the pre-clinical ultrasound system.
CONCLUSION
These findings together suggest that CE-EBUS can perform contrast imaging comparable to that produced by commercial pre-clinical and clinical ultrasound systems, with potential for clinical characterization of mediastinal lymph nodes in lung cancer patients.
Topics: Mice; Animals; Humans; Lung Neoplasms; Carcinoma, Non-Small-Cell Lung; Microbubbles; Sensitivity and Specificity; Lymphatic Metastasis; Bronchoscopy; Neoplasm Staging; Mice, Inbred C57BL; Lymph Nodes; Endoscopic Ultrasound-Guided Fine Needle Aspiration; Retrospective Studies
PubMed: 37813701
DOI: 10.1016/j.ultrasmedbio.2023.08.020