Clinical Oral Investigations Oct 2023Nano-modified surfaces for dental implants may improve gingival fibroblast adhesion and antibacterial characteristics through cell-surface interactions. The present...
OBJECTIVES
Nano-modified surfaces for dental implants may improve gingival fibroblast adhesion and antibacterial characteristics through cell-surface interactions. The present study investigated how a nanocavity titanium surface impacts the viability and adhesion of human gingival fibroblasts (HGF-1) and compared its response to Porphyromonas gingivalis with those of marketed implant surfaces.
MATERIAL AND METHODS
Commercial titanium and zirconia disks, namely, sandblasted and acid-etched titanium (SLA), sandblasted and acid-etched zirconia (ZLA), polished titanium (PT) and polished zirconia (ZrP), and nanostructured disks (NTDs) were tested. Polished titanium disks were etched with a 1:1 combination of 98% HSO and 30% HO (piranha etching) for 5 h at room temperature to produce the NTDs. Atomic force microscopy was used to measure the surface topography, roughness, adhesion force, and work of adhesion. MTT assays and immunofluorescence staining were used to examine cell viability and adhesion after incubation of HGF-1 cells on the disk surfaces. After incubation with P. gingivalis, conventional culture, live/dead staining, and SEM were used to determine the antibacterial properties of NTD, SLA, ZLA, PT, and ZrP.
RESULTS
Etching created nanocavities with 10-20-nm edge-to-edge diameters. Chemical etching increased the average surface roughness and decreased the surface adherence, while polishing and flattening of ZrP increased adhesion. However, only the NTDs inhibited biofilm formation and bacterial adherence. The NTDs showed antibacterial effects and P. gingivalis vitality reductions. The HGF-1 cells demonstrated greater viability on the NTDs compared to the controls.
CONCLUSION
Nanocavities with 10-20-nm edge-to-edge diameters on titanium disks hindered P. gingivalis adhesion and supported the adhesion of gingival fibroblasts when compared to the surfaces of currently marketed titanium or zirconia dental implants.
CLINICAL RELEVANCE
This study prepared an effective antibacterial nanoporous surface, assessed its effects against oral pathogens, and demonstrated that surface characteristics on a nanoscale level influenced oral pathogens and gingival fibroblasts.
CLINICAL TRIAL REGISTRATION
not applicable.
Topics: Humans; Dental Implants; Titanium; Hydrogen Peroxide; Biofilms; Nanostructures; Anti-Bacterial Agents; Surface Properties; Fibroblasts
PubMed: 37653076
DOI: 10.1007/s00784-023-05235-4 -
Materials (Basel, Switzerland) Aug 2023Fog-harvesting performance is influenced by surface wettability, patterned structure and the heat transfer coefficient. In this work, we have prepared different surfaces...
Fog-harvesting performance is influenced by surface wettability, patterned structure and the heat transfer coefficient. In this work, we have prepared different surfaces with a stripe array of superhydrophilic, superslippery and superslippery/superhydrophilic surfaces for fog harvesting on silicon substrates using photolithography and silver-assisted chemical etching. The surface wettability and heat transfer coefficients of the above samples have been investigated. We analyzed the contact angle, sliding angle and transport state of droplets on these surfaces. The fog-harvesting rate of all samples under different voltages of the cooling pad (V = 0, 2.0, 2.5, 3.0, 3.5 V) was measured. Results showed that the superslippery/superhydrophilic striped surface could achieve rapid droplet nucleation, directional transport and efficient collection due to its superhydrophilic striated channels and the Laplace pressure difference between different wettability regions. At a condensation voltage of 3.5 V, the fog-harvesting rate efficiencies of the uniformly striped superhydrophilic and superslippery surface were 1351 mg·cm·h and 1265 mg·cm·h, respectively, while the fog-harvesting rate of the superslippery/superhydrophilic striped surface was 1748 mg·cm·h. Compared with the original silicon surface, the maximum fog-harvesting rate of the superslippery/superhydrophilic striped surface was improved by 86.9%. This study offers significant insights into the impact of heat transfer and silicon surface wettability on the process of fog collection.
PubMed: 37570127
DOI: 10.3390/ma16155423 -
Micromachines Oct 2023The surface-tension-driven coalescence of drops has been extensively studied because of the omnipresence of the phenomenon and its significance in various natural and... (Review)
Review
The surface-tension-driven coalescence of drops has been extensively studied because of the omnipresence of the phenomenon and its significance in various natural and engineering systems. When two drops come into contact, a liquid bridge is formed between them and then grows in its lateral dimensions. As a result, the two drops merge to become a bigger drop. The growth dynamics of the bridge are governed by a balance between the driving force and the viscous and inertial resistances of involved liquids, and it is usually represented by power-law scaling relations on the temporal evolution of the bridge dimension. Such scaling laws have been well-characterized for the coalescence of unconfined or freely suspended drops. However, drops are often confined by solid or liquid surfaces and thus are a different shape from spheres, which affects their coalescence dynamics. As such, the coalescence of confined drops poses more complicated interfacial fluid dynamics challenges compared to that of unconfined drops. Although there have been several studies on the coalescence of confined drops, they have not been systematically reviewed in terms of the properties and geometry of the confining surface. Thus, we aim to review the current literature on the coalescence of confined drops in three categories: drop coalescence on a solid surface, drop coalescence on a deformable surface, and drop coalescence between two parallel surfaces with a small gap (i.e., Hele-Shaw cell), with a focus on power-law scaling relations, and to suggest challenges and outlooks for future research on the phenomena.
PubMed: 38004903
DOI: 10.3390/mi14112046 -
Computational and Structural... Dec 2024The study of protein molecular surfaces enables to better understand and predict protein interactions. Different methods have been developed in computer vision to...
The study of protein molecular surfaces enables to better understand and predict protein interactions. Different methods have been developed in computer vision to compare surfaces that can be applied to protein molecular surfaces. The present work proposes a method using the Wave Kernel Signature: Protein LOcal Surficial Similarity Screening (PLO3S). The descriptor of the PLO3S method is a local surface shape descriptor projected on a unit sphere mapped onto a 2D plane and called Surface Wave Interpolated Maps (SWIM). PLO3S allows to rapidly compare protein surface shapes through local comparisons to filter large protein surfaces datasets in protein structures virtual screening protocols.
PubMed: 38189058
DOI: 10.1016/j.csbj.2023.12.002 -
Nanomaterials (Basel, Switzerland) Aug 2023Transparent superhydrophobic coatings have been extensively investigated due to their ability to provide self-cleaning properties for outdoor applications. However, the... (Review)
Review
Transparent superhydrophobic coatings have been extensively investigated due to their ability to provide self-cleaning properties for outdoor applications. However, the widespread implementation of these coatings on a large scale is impeded by the challenges of poor durability and complex fabrication procedures. In this review, the fundamentals and theories governing the mutually exclusive properties of superhydrophobicity, optical transparency, and susceptibility to wear are introduced, followed by a discussion of representative examples of advanced surface design and processing optimizations. Also, robust evaluation protocols for assessing mechanical and chemical stabilities are briefed and potential research directions are presented. This review can offer the research community a better understanding of durable and transparent superhydrophobic surfaces, thereby facilitating their development for real-world applications.
PubMed: 37630944
DOI: 10.3390/nano13162359 -
Bioengineering (Basel, Switzerland) Oct 2023The purpose of this study was to investigate the effects of different peri-implantitis treatment methods (Er,Cr:YSGG laser, diode laser, and electrocautery) on various...
The purpose of this study was to investigate the effects of different peri-implantitis treatment methods (Er,Cr:YSGG laser, diode laser, and electrocautery) on various titanium implant surfaces: machined; sandblasted, large-grit, and acid-etched; and femtosecond laser-treated surfaces. Grade 4 titanium (Ti) disks, with a diameter of 10 mm and a thickness of 1 mm, were fabricated and treated using the aforementioned techniques. Subsequently, each treated group of disks underwent different peri-implantitis treatment methods: Er,Cr:YSGG laser (Biolase, Inc., Foothill Ranch, CA, USA), diode laser (Biolase, Inc., Foothill Ranch, CA, USA), and electrocautery (Ellman, Hicksville, NY, USA). Scanning electron microscopy, energy-dispersive X-ray spectroscopy, and wettability were used to characterize the chemical compositions and surfaces of the treated titanium surfaces. Significant changes in surface roughness were observed in both the electrocautery (Sa value of machined surface = 0.469, SLA surface = 1.569, femtosecond laser surface = 1.741, and = 0.025) and Er,Cr:YSGG laser (Ra value of machined surface = 1.034, SLA surface = 1.380, femtosecond laser surface = 1.437, and = 0.025) groups. On femtosecond laser-treated titanium implant surfaces, all three treatment methods significantly reduced the surface contact angle (control = 82.2°, diode laser = 74.3°, Er,Cr:YSGG laser = 73.8°, electrocautery = 76.2°, and = 0.039). Overall, Er,Cr:YSGG laser and electrocautery treatments significantly altered the surface roughness of titanium implant surfaces. As a result of surface composition after different peri-implantitis treatment methods, relative to the diode laser and electrocautery, the Er,Cr:YSGG laser increased oxygen concentration. The most dramatic change was observed after Er:Cr;YSGG laser treatment, urging caution for clinical applications. Changes in surface composition and wettability were observed but were not statistically significant. Further research is needed to understand the biological implications of these peri-implantitis treatment methods.
PubMed: 38002374
DOI: 10.3390/bioengineering10111251 -
Polymers Jun 2023There is a constant need to improve patient comfort and product performance associated with the use of medical devices. Efforts to optimise the tribological... (Review)
Review
There is a constant need to improve patient comfort and product performance associated with the use of medical devices. Efforts to optimise the tribological characteristics of medical devices usually involve modifying existing devices without compromising their main design features and functionality. This article constitutes a state-of-the-art review of the influence of dry friction on polymeric components used in medical devices, including those having microscale surface features. Surface tribology and contact interactions are discussed, along with alternative forms of surface texturing. Evident gaps in the literature, and areas warranting future research are highlighted; these include friction involving polymer Vs polymer surfaces, information regarding which topologies and feature spacings provide the best performing textured surfaces, and design guidelines that would assist manufacturers to minimise or maximise friction under non-lubricated conditions.
PubMed: 37447503
DOI: 10.3390/polym15132858 -
Materials (Basel, Switzerland) Aug 2023The article reports the results of experimental study of vibratory surface grinding in the range of low excitation frequencies and variable directions of excited...
The article reports the results of experimental study of vibratory surface grinding in the range of low excitation frequencies and variable directions of excited vibrations in the plane of the table, and investigates the effect of these directions on the roughness and waviness of the ground surface. The tests were conducted on a production surface grinder with a vibrating table on which the samples were mounted. The table made it possible to change the direction for the introduction of vibrations to the workpiece (longitudinally, transversely, and obliquely to the longitudinal feed of the table) and the parameters of the introduced vibrations, frequency and amplitude. In the course of the study, selected parameters of surface roughness and waviness of samples ground conventionally and with vibrations introduced on the workpiece were compared. The results show an improvement in the roughness and waviness parameters of the vibration-ground surfaces compared to surfaces ground without vibration (conventionally). The profile of the ground surface was subjected to Fourier analysis and the harmonic components of the surface shape of the ground samples were determined to characterize the effect of the introduced vibrations on the surface roughness. It was determined that the direction of vibration introduction, which is most favorable in terms of the parameters of the geometric structure of the ground surface, is the direction perpendicular to the longitudinal feed of the grinding table. In other directions of vibration introduction, the simultaneous effect of improving both parameters of the geometric structure of the ground surface profile was not obtained.
PubMed: 37687512
DOI: 10.3390/ma16175819 -
Journal of Functional Biomaterials Apr 2024Zirconia ceramic implants are commercially available from a rapidly growing number of manufacturers. Macroscopic and microscopic surface design and characteristics are... (Review)
Review
Zirconia ceramic implants are commercially available from a rapidly growing number of manufacturers. Macroscopic and microscopic surface design and characteristics are considered to be key determining factors in the success of the osseointegration process. It is, therefore, crucial to assess which surface modification promotes the most favorable biological response. The purpose of this study was to conduct a comparison of modern surface modifications that are featured in the most common commercially available zirconia ceramic implant systems. A review of the currently available literature on zirconia implant surface topography and the associated bio-physical factors was conducted, with a focus on the osseointegration of zirconia surfaces. After a review of the selected articles for this study, commercially available zirconia implant surfaces were all modified using subtractive protocols. Commercially available ceramic implant surfaces were modified or enhanced using sandblasting, acid etching, laser etching, or combinations of the aforementioned. From our literature review, laser-modified surfaces emerged as the ones with the highest surface roughness and bone-implant contact (BIC). It was also found that surface roughness could be controlled to achieve optimal roughness by modifying the laser output power during manufacturing. Furthermore, laser surface modification induced a very low amount of preload microcracks in the zirconia. Osteopontin (OPN), an early-late osteogenic differentiation marker, was significantly upregulated in laser-treated surfaces. Moreover, surface wettability was highest in laser-treated surfaces, indicating favorable hydrophilicity and thus promoting early bone forming, cell adhesion, and subsequent maturation. Sandblasting followed by laser modification and sandblasting followed by acid etching and post-milling heat treatment (SE-H) surfaces featured comparable results, with favorable biological responses around zirconia implants.
PubMed: 38667548
DOI: 10.3390/jfb15040091 -
Ultramicroscopy Nov 2023Fermi surfaces of transition metals, which describe all thermodynamical and transport quantities of solids, often fail to be modeled by one-electron mean-field theory...
Fermi surfaces of transition metals, which describe all thermodynamical and transport quantities of solids, often fail to be modeled by one-electron mean-field theory due to strong correlations among the valence electrons. In addition, relativistic spin-orbit coupling pronounced in heavier elements lifts the degeneracy of the energy bands and further modifies the Fermi surface. Palladium and rhodium, two 4d metals attributed to show significant spin-orbit coupling and electron correlations, are ideal for a systematic and fundamental study of the two fundamental physical phenomena and their interplay in the electronic structure. In this study, we explored the Fermi surface of the 4d noble metals palladium and rhodium obtained via high-resolution constant initial state momentum microscopy. The complete 3D-Fermi surfaces of palladium and rhodium were tomographically mapped using soft X-ray photon energies from 34 eV up to 660 eV. To fully capture the orbital angular momentum of states across the Fermi surface, the Fermi surface tomography was performed using p- and s- polarized light. Applicability and limitations of the nearly-free electron final state model in photoemission are discussed using a complex band structure model supported by experimental evidence. The significance of spin-orbit coupling and electron correlations across the Fermi surfaces will be discussed within the context of the photoemission results. State-of-the-art fully relativistic Korringa-Kohn-Rostoker (KKR) calculations within the one-step model of photoemission are used to support the experimental results.
PubMed: 37586245
DOI: 10.1016/j.ultramic.2023.113820