International Journal of Ophthalmology 2024To assess the clinical efficacy and safety of combining panretinal photocoagulation (PRP) with intravitreal conbercept (IVC) injections for patients with high-risk...
AIM
To assess the clinical efficacy and safety of combining panretinal photocoagulation (PRP) with intravitreal conbercept (IVC) injections for patients with high-risk proliferative diabetic retinopathy (HR-PDR) complicated by mild or moderate vitreous hemorrhage (VH), with or without diabetic macular edema (DME).
METHODS
Patients diagnosed with VH with/without DME secondary to HR-PDR and received PRP combined with IVC injections were recruited in this retrospective study. Upon establishing the patient's diagnosis, an initial IVC was performed, followed by prompt administration of PRP. In cases who significant bleeding persisted and impeded the laser operation, IVC was sustained before supplementing with PRP. Following the completion of PRP, patients were meticulously monitored for a minimum of six months. Laser therapy and IVC injections were judiciously adjusted based on fundus fluorescein angiography (FFA) results. Therapeutic effect and the incidence of adverse events were observed.
RESULTS
Out of 42 patients (74 eyes), 29 were male and 13 were female, with a mean age of 59.17±12.74y (33-84y). The diabetic history was between 1wk and 26y, and the interval between the onset of visual symptoms and diagnosis of HR-PDR was 1wk-1y. The affected eye received 2.59±1.87 (1-10) IVC injections and underwent 5.5±1.02 (4-8) sessions of PRP. Of these, 68 eyes received PRP following 1 IVC injection, 5 eyes after 2 IVC injections, and 1 eye after 3 IVC injections. Complete absorption of VH was observed in all 74 eyes 5-50wk after initial treatment, with resolution of DME in 51 eyes 3-48wk after initial treatment. A newly developed epiretinal membrane was noted in one eye. Visual acuity significantly improved in 25 eyes. No complications such as glaucoma, retinal detachment, or endophthalmitis were reported.
CONCLUSION
The study suggests that the combination of PRP with IVC injections is an effective and safe modality for treating diabetic VH in patients with HR-PDR.
PubMed: 38895681
DOI: 10.18240/ijo.2024.06.11 -
BMC Ophthalmology Dec 2023Here we described a new threading technique for the universal fixation of any posterior chamber intraocular lens (IOL).
BACKGROUND
Here we described a new threading technique for the universal fixation of any posterior chamber intraocular lens (IOL).
METHODS
Twenty-seven eyes of 27 patients whose surgery done by Surgeon A with the needle-guided method or the suture needle retrograde threading (SNRT) method for intrascleral IOL fixation were enrolled in the first group. Thirty-four eyes of 34 patients whose surgery done by Surgeon A, Surgeon B or Surgeon C with the SNRT method for intrascleral IOL fixation were grouped into three sub-groups by surgeon. Information regarding age, sex, best-available visual acuity (BCVA), intraocular pressure (IOP), past ophthalmological history, threading time (from puncturing to externalizing suture) and complications during and after the surgery were gathered.
RESULTS
The analysis showed that the threading time was less in the SNRT group than needle-guided group by Surgeon A. There was one eye with suture needle slipping from the guide needle when guiding out of the eye. The threading procedure was completed one time without suture ruptures or loop slippage in the SNRT group operated by Surgeon A. And using the SNRT method, Surgeon A, Surgeon B, and Surgeon C did not show any significant difference in threading time. No complications (e.g., vitreous hemorrhage, hyphemia, retinal detachment, suprachoroidal hemorrhage, or hypotony) were observed during surgery or postoperatively in all cases. No leakage occurred at the site of the puncture after the operation.
CONCLUSIONS
The described technique appears to be a safe, simple, easy-to-learn, and universal surgical method, which is suitable for various types of IOLs.
Topics: Humans; Lens Implantation, Intraocular; Lenses, Intraocular; Sclera; Eye, Artificial; Suture Techniques; Sutures; Retrospective Studies; Postoperative Complications
PubMed: 38114950
DOI: 10.1186/s12886-023-03258-9 -
Indian Journal of Ophthalmology Aug 2023Aniridia is defined as missing iris tissue which can be partial, subtotal, or total. Characteristic clinical symptoms include photophobia and decreased visual acuity due...
BACKGROUND
Aniridia is defined as missing iris tissue which can be partial, subtotal, or total. Characteristic clinical symptoms include photophobia and decreased visual acuity due to an increased light perception. In addition to this, disturbing cosmetic problems are prevalent. Even after implantation of an intraocular lens, patients often tend to be unsatisfied.
PURPOSE
The answer to this problem lies in the implantation of an aniridic scleral fixation of intraocular lens (SFIOL), which has a central optical axis that acts as the refractive lens and a peripheral rim of a hyperpigmented area that mimics the iris and hence reduces photophobia. The purpose of the video was to demonstrate the use of black diaphragm intraocular lens (BDIOL) implantation, its surgical steps, and its outcomes.
SYNOPSIS
We report one such case where a young patient presented with post-traumatic aniridia with subluxated total cataract and spillover vitreous hemorrhage. He was subjected to a vitrectomy, cataract removal, and placement of an aniridic SFIOL with prolene 9-0 using the four-point fixation method. This gave an extremely gratifying outcome and solved both problems, that is, vision and photophobia. Highlight: Before implantation of the SFIOL, the patients had reduced visual acuity from aphakia and intolerable glare from aniridia. In this case-based approach and with relevant example, we tried to provide a solution for tricky scenarios like co-existing traumatic cataract and traumatic aniridia. The patient showed improved visual acuity and marked glare reduction after black diaphragm SFIOL implantation.
VIDEO LINK
https://youtu.be/atl60WetFsM.
Topics: Male; Humans; Lens Implantation, Intraocular; Photophobia; Lenses, Intraocular; Iris; Aniridia; Vision Disorders; Eye Injuries; Cataract
PubMed: 37530301
DOI: 10.4103/IJO.IJO_775_23 -
Bioengineered Dec 2024Exosomes are membranous structures measuring between 40-120 nm that are secreted by various cells of the human body into the body fluid system. Exosomes contain...
Exosomes are membranous structures measuring between 40-120 nm that are secreted by various cells of the human body into the body fluid system. Exosomes contain proteins, mRNA, miRNA, and signaling molecules, and physiologically they assist in the intercellular transport of proteins and RNA molecules. In this study, we used an immunoaffinity filter paper platform combined with scanning electron microscopy and microfluidic systems to detect the size of exosomes within the aqueous humor. Eight aqueous humor samples showed three distinct sizes of exosomes that were significantly different on scanning electron microscopy( < 0.01). We further used nanoparticle tracking analysis to assess the size distribution of exosomes within the aqueous humor. We found significantly different distributions of exosomes between patients with three different ocular diseases and patients with normal cataracts as controls. An obvious peak of exomeres(size around 35 nm)was found in the patients with central retinal vein occlusion and vitreous hemorrhage. Flare-ups of large exosomes(size 90-120 nm)were found in the patients with the inflammatory ocular disease pars planitis. No obvious peaks in exomeres or large exosomes were found in the control group. There was a high association between the distribution of exosomes and the pathogenesis of ocular diseases. After intravitreal anti-vascular endothelial growth factor treatment, the aqueous humor from the patients with neovascular diseases showed a significant reduction in exosomes in nanoparticle tracking analysis. These findings suggest that at least three distinct sizes of exosomes exist in the aqueous humor:(1)exomeres:<35 nm;(2)small exosomes:60-80 nm; and (3)large exosomes:90-120 nm. Different sizes of exosomes may have different implications in normal or diseased eyes.
Topics: Humans; Exosomes; Retinal Diseases; MicroRNAs; Aqueous Humor; Cataract
PubMed: 38155415
DOI: 10.1080/21655979.2023.2297320 -
Medicine Oct 2023To evaluate the safety and efficacy of modified Ahmed glaucoma valve (AGV) implantation (long scleral tunnel technique) in the treatment of neovascularization glaucoma...
To evaluate the safety and efficacy of modified Ahmed glaucoma valve (AGV) implantation (long scleral tunnel technique) in the treatment of neovascularization glaucoma (NVG). This retrospective observational case series included 23 patients (23 eyes) diagnosed with NVG secondary to proliferative diabetic retinopathy from January 2020 to June 2021. All 23 cases received anti-vascular endothelial growth factor treatment. Then, after 3 to 7 days, these cases were treated with modified AGV implantation (long scleral tunnel technique) and were followed up for at least 6 months. The best corrected visual acuity, intraocular pressure, numbers of antiglaucoma medications used, and postoperative complications were observed at 1 week and 1, 3, and 6 months after treatment. With treatment, the mean best corrected visual acuity improved significantly (P < .001) from 1.62 ± 0.52 logMAR preoperatively to 1.29 ± 0.36 logMAR at the 6-month follow-up. The mean postoperative intraocular pressure was significantly lower than that before modified AGV implantation during follow-up period, decreasing from 45.48 ± 7.86 mm Hg preoperatively to 14.87 ± 1.96 mm Hg at 1 week, 18.39 ± 2.25 mm Hg at 1 month, 16.61 ± 1.47 mm Hg at 3 months, and 17.48 ± 1.38 mm Hg at 6 months (F = 256.646, P < .001). The median number of antiglaucoma medications used by patients also significantly decreased from 3 (3-4) preoperatively to 0 (0-1) at the 6-month follow-up after surgery (Z = -4.248, P < .001). Postoperative complications included hyphema in 2 cases and vitreous hemorrhage in 1 case, and all 3 patients achieved satisfactory recovery with treatment. No drainage tube-related complications occurred among our patients. Long scleral tunnel technique is a safe and effective surgical treatment for NVG with fewer drainage tube-related complications.
Topics: Humans; Glaucoma Drainage Implants; Antiglaucoma Agents; Retrospective Studies; Glaucoma; Intraocular Pressure; Treatment Outcome; Postoperative Complications; Prosthesis Implantation; Drainage; Follow-Up Studies
PubMed: 37861521
DOI: 10.1097/MD.0000000000035745 -
Eye (London, England) Aug 2023To report 5-year real-world efficacy and safety data following the treatment of chronic diabetic macular oedema (DMO) with the intravitreal 0.19 mg fluocinolone...
BACKGROUND/AIM
To report 5-year real-world efficacy and safety data following the treatment of chronic diabetic macular oedema (DMO) with the intravitreal 0.19 mg fluocinolone acetonide implant(ILUVIEN).
METHODS
Retrospective cohort study of 31 eyes treated with ILUVIEN for chronic DMO at a tertiary centre in Birmingham (UK). Best corrected visual acuity (BCVA) and central retinal thickness (CRT) were recorded at baseline, and then at 1-,2-,3-, and 5-years. Safety was assessed based on intraocular pressure (IOP) -lowering medication, surgery, and other complications.
RESULTS
BCVA significantly improved 1-year post-ILUVIEN (+4.2 letters, p < 0.05) and gradually reverted to baseline levels over the 5-year period of follow-up (+0.2 letters at year-5). A significant and sustained CRT reduction was observed throughout the 5-years. The proportion of eyes on IOP-lowering medication increased from 16% at baseline, to 70% at 5-years (p < 0.001) with eyes on a mean of 1.3 medications. Laser trabeculoplasty (n = 2), cyclodiode laser (n = 1), and trabeculoplasty and trabeculotomy (n = 1, in the same eye; 3.2%) were required for uncontrolled IOP. Other complications included endophthalmitis (n = 1) and vitreous haemorrhage (n = 1). 58% of eyes required additional intravitreal injections, with a mean 29.2 months to first injection. We observed a 69% reduction in treatment burden following treatment with ILUVIEN implant.
CONCLUSIONS
Our real-world results confirm the efficacy of the ILUVIEN implant over 5 years, with two-thirds of eyes having improved or stable visual acuity 5 years after ILUVIEN, and an overall sustained improvement in anatomical outcome. Although the rate of IOP-lowering medications use was higher than previously reported, the rate of incisional IOP-lowering surgery and other complications remained low and in keeping with rates reported in larger studies.
Topics: Humans; Fluocinolone Acetonide; Glucocorticoids; Macular Edema; Diabetic Retinopathy; Retrospective Studies; Treatment Outcome; Intravitreal Injections; Drug Implants; Diabetes Mellitus
PubMed: 36513858
DOI: 10.1038/s41433-022-02338-2 -
Computational and Mathematical Methods... 2023[This retracts the article DOI: 10.1155/2022/7393661.].
Retracted: 23G Minimally Invasive Vitrectomy Combined with Glaucoma Drainage Valve Implantation and Phacoemulsification Cataract Extraction for Neovascular Glaucoma Secondary to Proliferative Diabetic Retinopathy with Vitreous Hemorrhage.
[This retracts the article DOI: 10.1155/2022/7393661.].
PubMed: 37538480
DOI: 10.1155/2023/9868749 -
Bilaterally subluxed diffractive intraocular lenses: big expectations and even bigger comorbidities.Journal of Cataract and Refractive... Mar 2024A 78-year-old woman with an ocular history of cataract surgery with a diffractive intraocular lens (IOL) in each eye has developed fluctuating vision, greater in the...
A 78-year-old woman with an ocular history of cataract surgery with a diffractive intraocular lens (IOL) in each eye has developed fluctuating vision, greater in the right eye than the left eye, after 4 years. She has a history of inactive central serous retinopathy and a vision potential of 20/25 + 2 in the right eye and 20/25 in the left eye. She has well-controlled diabetes, hypertension, and hypercholesterolemia. She has enjoyed her spectacle independence for some time and wishes to have her vision restored. On examination, her uncorrected distance visual acuity (UDVA) was 20/50 in the right eye and 20/25 in the left eye and her uncorrected near visual acuity (UNVA) was J3 in the right eye and J1 in the left eye. Intraocular pressures (IOPs) measured 22 mm Hg in the right eye and 18 mm Hg in the left eye. Pupils had limited reactivity with irregularity in the right eye but no obvious relative afferent pupillary defect. Motility and confrontation visual fields were unremarkable in both eyes. Retinal acuity meter was 20/20 in both eyes, and manifest refraction was plano -1.25 × 105 20/40, J3 in the right eye and +0.50 × 20/25, J1 in the left eye. Pertinent findings on slitlamp examination included temporal iris atrophy and transillumination defects greater in the right eye than the left eye, peripupillary pseudoexfoliative changes in both eyes, significant inferior subluxation of a diffractive 3-piece posterior chamber IOL in the capsular bag with lens-pitting peripherally and few central, moderate pseudophacodonesis, and an open posterior capsule in the right eye. In the left eye, she had mild inferior subluxation of a single-piece acrylic diffractive IOL in the capsular bag with moderate pseudophacodonesis and an open posterior capsule (Figure 1JOURNAL/jcrs/04.03/02158034-202403000-00019/figure1/v/2024-02-20T193212Z/r/image-tiff). All other anterior segment findings were unremarkable. On dilated posterior examination, she had a cup-to-disc ratio of 0.50 in the right eye and 0.65 in the left eye without edema hemorrhage or pallor. There were attenuated vessels in both eyes, posterior vitreous detachment in both eyes, and a few small drusen peripherally in both eyes. There was retinal pigment epithelium irregularity and dropout parafoveal in the right eye and subfoveal in the left eye (Figure 2). There was no evidence of macular edema, subretinal fluid, choroidal thickening, or neovascular membranes. The periphery was unremarkable in both eyes.JOURNAL/jcrs/04.03/02158034-202403000-00019/figure2/v/2024-02-20T193212Z/r/image-tiff What testing would you obtain preoperatively to help guide your decision-making? How would you counsel the patient regarding comorbid conditions and expectations?
Topics: Humans; Female; Aged; Lens Implantation, Intraocular; Motivation; Lenses, Intraocular; Cataract Extraction; Visual Acuity
PubMed: 38381619
DOI: 10.1097/j.jcrs.0000000000001388 -
Journal of Translational Medicine May 2024Diabetic retinopathy (DR) is the leading cause of blinding eye disease among working adults and is primarily attributed to the excessive proliferation of microvessels,...
BACKGROUND
Diabetic retinopathy (DR) is the leading cause of blinding eye disease among working adults and is primarily attributed to the excessive proliferation of microvessels, which leads to vitreous hemorrhage and retinal traction, thereby significantly impairing patient vision. NSUN2-mediated RNA mC methylation is implicated in various diseases, and in this investigation, we focused on elucidating the impact of NSUN2 on the regulation of the expression of the downstream gene MUC1, specifically through RNA mC methylation, on the progression of DR.
METHOD
Utilizing Microarray analysis, we examined patient vitreous fluid to pinpoint potential therapeutic targets for DR. Differential expression of NSUN2 was validated through qRT-PCR, Western blot, and immunofluorescence in human tissue, animal tissue, and cell model of DR. The relationship between NSUN2 and DR was explored in vitro and in vivo through gene knockdown and overexpression. Various techniques, such as MeRIP-qPCR and dot blot, were applied to reveal the downstream targets and mechanism of action of NSUN2.
RESULTS
The levels of both NSUN2 and RNA mC methylation were significantly elevated in the DR model. Knockdown of NSUN2 mitigated DR lesion formation both in vitro and in vivo. Mechanistically, NSUN2 promoted MUC1 expression by binding to the RNA mC reader ALYREF. Knockdown of ALYREF resulted in DR lesion alterations similar to those observed with NSUN2 knockdown. Moreover, MUC1 overexpression successfully reversed a series of DR alterations induced by NSUN2 silencing.
CONCLUSIONS
NSUN2 regulates the expression of MUC1 through ALYREF-mediated RNA mC methylation, thereby regulating the progression of DR and providing a new option for the treatment of DR in the future.
Topics: Animals; Humans; Male; Diabetic Retinopathy; Disease Progression; Gene Expression Regulation; Gene Knockdown Techniques; Methylation; Methyltransferases; Mice, Inbred C57BL; Mucin-1; RNA Methylation
PubMed: 38764010
DOI: 10.1186/s12967-024-05287-4 -
Ophthalmology Science 2024Automated machine learning (AutoML) has emerged as a novel tool for medical professionals lacking coding experience, enabling them to develop predictive models for...
PURPOSE
Automated machine learning (AutoML) has emerged as a novel tool for medical professionals lacking coding experience, enabling them to develop predictive models for treatment outcomes. This study evaluated the performance of AutoML tools in developing models predicting the success of pneumatic retinopexy (PR) in treatment of rhegmatogenous retinal detachment (RRD). These models were then compared with custom models created by machine learning (ML) experts.
DESIGN
Retrospective multicenter study.
PARTICIPANTS
Five hundred and thirty nine consecutive patients with primary RRD that underwent PR by a vitreoretinal fellow at 6 training hospitals between 2002 and 2022.
METHODS
We used 2 AutoML platforms: MATLAB Classification Learner and Google Cloud AutoML. Additional models were developed by computer scientists. We included patient demographics and baseline characteristics, including lens and macula status, RRD size, number and location of breaks, presence of vitreous hemorrhage and lattice degeneration, and physicians' experience. The dataset was split into a training (n = 483) and test set (n = 56). The training set, with a 2:1 success-to-failure ratio, was used to train the MATLAB models. Because Google Cloud AutoML requires a minimum of 1000 samples, the training set was tripled to create a new set with 1449 datapoints. Additionally, balanced datasets with a 1:1 success-to-failure ratio were created using Python.
MAIN OUTCOME MEASURES
Single-procedure anatomic success rate, as predicted by the ML models. F2 scores and area under the receiver operating curve (AUROC) were used as primary metrics to compare models.
RESULTS
The best performing AutoML model (F2 score: 0.85; AUROC: 0.90; MATLAB), showed comparable performance to the custom model (0.92, 0.86) when trained on the balanced datasets. However, training the AutoML model with imbalanced data yielded misleadingly high AUROC (0.81) despite low F2-score (0.2) and sensitivity (0.17).
CONCLUSIONS
We demonstrated the feasibility of using AutoML as an accessible tool for medical professionals to develop models from clinical data. Such models can ultimately aid in the clinical decision-making, contributing to better patient outcomes. However, outcomes can be misleading or unreliable if used naively. Limitations exist, particularly if datasets contain missing variables or are highly imbalanced. Proper model selection and data preprocessing can improve the reliability of AutoML tools.
FINANCIAL DISCLOSURES
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
PubMed: 38827487
DOI: 10.1016/j.xops.2024.100470