Neuroscience and Biobehavioral Reviews Mar 2024This systematic review of 52 studies provides a quantitative synthesis of the empirical literature on social and circadian rhythm correlates of suicidal thoughts and... (Meta-Analysis)
Meta-Analysis Review
This systematic review of 52 studies provides a quantitative synthesis of the empirical literature on social and circadian rhythm correlates of suicidal thoughts and behaviors (STB). Small-to-medium pooled effect sizes were observed for associations between evening chronotype and STB and suicidal ideation (SI), although the pooled effect size diminished when accounting for publication bias. Three studies employed longitudinal designs and suggested eveningness was predictive of future STB, with a small-to-medium effect size. Social rhythm irregularity was also a significant correlate of STB with pooled effect sizes in the medium range. Overall circadian rhythm disruption was not associated with STB, although certain circadian rhythm metrics, including mean daytime activity, circadian rhythm sleep-wake disorder diagnosis, and actigraphy-assessed amplitude were associated with STB. Pooled effect sizes for these indices were in the medium to large range. There is a need for additional longitudinal research on actigraphy-based circadian parameters and objective markers of circadian phase (i.e., dim-light melatonin onset) to gain a clearer understanding of associations of endogenous circadian function and STB beyond that which can be captured via self-report.
Topics: Humans; Sleep; Suicide; Circadian Rhythm; Chronobiology Disorders; Suicidal Ideation; Melatonin
PubMed: 38272337
DOI: 10.1016/j.neubiorev.2024.105560 -
Spine Deformity Nov 2022To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery.
METHODS
A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies.
RESULTS
Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt-chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°-55.42°] and Ti 32.58° [24.62°-40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°-29.53°] and Ti 20.15° [18.0°-22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7-22%) for CoCr and 12% (- 8-32%) for stainless steel (SS) (n = 2 studies each; Chi = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1-22%) for Ti (n = 3 studies) and 10% (2-19) for CoCr (n = 1 study). Among 6.0-6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°-14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°-40.62°), and pelvic tilt angle was 21.11° (18.35°-23.86°).
CONCLUSIONS
For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided.
LEVEL OF EVIDENCE
III.
Topics: Adult; Humans; Spinal Fusion; Stainless Steel; Titanium; Chromium Alloys; Pseudarthrosis; Cobalt; Chromium
PubMed: 35904725
DOI: 10.1007/s43390-022-00556-y -
Journal of Orthodontic Science 2023A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we... (Review)
Review
A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we aimed to assess the various metallurgical characteristics of the said metals and alloys. Four hundred and eighty-two documents in total were found after a thorough search of the online journals, and 169 of the papers were initially chosen. Ultimately, 16 documents were selected that satisfied the necessary inclusion and exclusion criteria, primarily studies, literature reviews, and comparative analyses. NiTi alloy was found to be the most commonly used alloy in construction of orthodontic wires across all the studies that we had selected for our review. It also had better performance and consistency in terms of its usage as depicted by the meta-analysis performed, with stainless steel wires being a close second primarily due to its lesser cost compared to the former. Metallurgy and orthodontics are inextricably linked with one another. The various components of orthodontics such as wires, pliers, and other instruments utilize the metallurgical characteristics of metals and alloys that are specially prepared for the challenges of this field. CRD42022378444.
PubMed: 37881657
DOI: 10.4103/jos.jos_52_23 -
The Journal of Contemporary Dental... Aug 2023The present systematic review aimed to report the studies concerning the primers in improving bond strength and identifying pertinent primers for a particular dental... (Meta-Analysis)
Meta-Analysis
AIM
The present systematic review aimed to report the studies concerning the primers in improving bond strength and identifying pertinent primers for a particular dental alloy by adhering to PRISMA precepts.
MATERIALS AND METHODS
PubMed and Semantic Scholar databases were scoured for articles using 10 search terms. studies satisfying the inclusion criteria were probed which were meticulously screened and scrutinized for eligibility adhering to the 11 exclusion criteria. The quality assessment tool for studies (QUIN Tool) containing 12 criteria was employed to assess the risk of bias (RoB).
RESULTS
A total of 48 studies assessing shear bond strength (SBS) and 15 studies evaluating tensile bond strength (TBS) were included in the qualitative synthesis. Concerning SBS, 33.4% moderate and 66.6% high RoB was observed. Concerning TBS, 26.8% moderate and 73.2% high RoB was discerned. Seventeen and two studies assessing SBS and TBS, respectively, were included in meta-analyses.
CONCLUSIONS
Shear bond strength and TBS increased for the primed alloys. Cyclic disulfide primer is best-suited for noble alloys when compared with thiol/thione primers. Phosphoric acid- and phosphonic acid ester-based primers are opportune for base alloys.
CLINICAL SIGNIFICANCE
The alloy-resin interface (ARI) would fail if an inappropriate primer was selected. Therefore, the selection of an appropriate alloy adhesive primer for an alloy plays a crucial role in prosthetic success. This systematic review would help in the identification and selection of a congruous primer for a selected alloy.
Topics: Databases, Factual; Dental Alloys; Disulfides; Thiones; Dental Cements
PubMed: 38193174
DOI: 10.5005/jp-journals-10024-3514 -
Clinical and Experimental Dental... Aug 2022This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces. (Review)
Review
OBJECTIVES
This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces.
MATERIAL AND METHODS
An electronic search for literature was conducted on PubMed, Embase, Scopus, and Web of Science and a total of 14 studies were included. Neutrophil responses were assessed based on adhesion, cell number, surface coverage, cell structure, cytokine secretion, reactive oxygen species (ROS) production, neutrophil activation, receptor expression, and neutrophil extracellular traps (NETs) release. The method of assessing the risk of bias was done using the toxicological data reliability assessment tool (TOXRTOOL).
RESULTS
Ten studies have identified a significant increase in neutrophil functions, such as surface coverage, cell adhesion, ROS production, and NETs released when interacting with rough titanium surfaces. Moreover, neutrophil interaction with rough-hydrophilic surfaces seems to produce less proinflammatory cytokines and ROS when compared to naive smooth and rough titanium surfaces. Regarding membrane receptor expression, two studies have reported that the FcγIII receptor (CD16) is responsible for initial neutrophil adhesion to hydrophilic titanium surfaces. Only one study compared neutrophil interaction with titanium alloy and zirconia toughened alumina surfaces and reported no significant differences in neutrophil cell count, activation, receptor expression, and death.
CONCLUSIONS
There are not enough studies to conclude neutrophil interactions with titanium and zirconia surfaces. However, different topographic modifications such as roughness and hydrophilicity might influence neutrophil interactions with titanium implant surfaces.
Topics: Dental Implants; Neutrophils; Reactive Oxygen Species; Reproducibility of Results; Surface Properties; Titanium; Zirconium
PubMed: 35535662
DOI: 10.1002/cre2.582 -
Journal of Esthetic and Restorative... Dec 2023The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. (Review)
Review
OBJECTIVE
The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning.
MATERIALS AND METHODS
An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded.
RESULTS
A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications.
CONCLUSIONS
The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions.
CLINICAL SIGNIFICANCE
ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Topics: Dental Implants; Dental Impression Technique; Computer-Aided Design; Research Design; Imaging, Three-Dimensional
PubMed: 37381677
DOI: 10.1111/jerd.13074 -
Clinical Oral Investigations Dec 2023To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
METHODS
An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done.
RESULTS
Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up.
CONCLUSION
Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055).
CLINICAL RELEVANCE
The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Topics: Humans; Dental Implants; Treatment Outcome; Dental Restoration Failure; Zirconium; Titanium; Dental Prosthesis Design
PubMed: 38135804
DOI: 10.1007/s00784-023-05401-8 -
Materials (Basel, Switzerland) Jun 2021The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch... (Review)
Review
The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch prostheses. A literature search was conducted on MEDLINE, Scopus and Cochrane Library, until the 1st of March 2021, with the following search terms: framework or substructure combined with "dental implants". The outcomes evaluated were: implant and prosthesis survival, bone resorption, biological and technical complications. The Cochrane Handbook for Systematic Reviews of Interventions was employed to assess the risk of bias in randomized clinical trials. The Newcastle-Ottawa quality assessment scale was used for non-randomized studies. In total, 924 records were evaluated for title and abstract, and 11 studies were included in the review: 4 clinical randomized trials and 7 cohort studies. The framework materials investigated were: gold alloy, titanium, silver-palladium alloy, zirconia and polymers including acrylic resin and carbon-fiber-reinforced composites. High implant and prosthetic cumulative survival rates were recorded by all included studies. Various materials and different fabrication techniques are now available as alternatives to traditional cast metal frameworks, for full-arch implant-supported rehabilitations. Further long-term studies are needed to validate the use of these materials and clarify their specific clinical indications and manufacturing protocols to optimize their clinical outcomes.
PubMed: 34204681
DOI: 10.3390/ma14123251 -
Journal of Functional Biomaterials Apr 2023Zinc-based biodegradable metals (BMs) have been developed for biomedical implant materials. However, the cytotoxicity of Zn and its alloys has caused controversy. This... (Review)
Review
Zinc-based biodegradable metals (BMs) have been developed for biomedical implant materials. However, the cytotoxicity of Zn and its alloys has caused controversy. This work aims to investigate whether Zn and its alloys possess cytotoxic effects and the corresponding influence factors. According to the guidelines of the PRISMA statement, an electronic combined hand search was conducted to retrieve articles published in PubMed, Web of Science, and Scopus (2013.1-2023.2) following the PICOS strategy. Eighty-six eligible articles were included. The quality of the included toxicity studies was assessed utilizing the ToxRTool. Among the included articles, extract tests were performed in 83 studies, and direct contact tests were conducted in 18 studies. According to the results of this review, the cytotoxicity of Zn-based BMs is mainly determined by three factors, namely, Zn-based materials, tested cells, and test system. Notably, Zn and its alloys did not exhibit cytotoxic effects under certain test conditions, but significant heterogeneity existed in the implementation of the cytotoxicity evaluation. Furthermore, there is currently a relatively lower quality of current cytotoxicity evaluation in Zn-based BMs owing to the adoption of nonuniform standards. Establishing a standardized in vitro toxicity assessment system for Zn-based BMs is required for future investigations.
PubMed: 37103296
DOI: 10.3390/jfb14040206 -
BMC Oral Health Jul 2022Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also...
BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.
Topics: Artifacts; Humans; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires; Stainless Steel
PubMed: 35854295
DOI: 10.1186/s12903-022-02317-9