Clinical Infectious Diseases : An... Jun 2020We conducted a systematic review of relevant syphilis diagnostic literature to address the question, "What is the sensitivity and specificity of the treponemal tests...
We conducted a systematic review of relevant syphilis diagnostic literature to address the question, "What is the sensitivity and specificity of the treponemal tests currently approved by the Food and Drug Administration (FDA) for the diagnosis of syphilis (by stage)?" There were 16 treponemal assays evaluated: 13 immunoassays and 3 manual assays (fluorescent treponemal antibody absorbed test [FTA-ABS], microhemagglutination assay for Treponema pallidum antibodies [MHA-TP], Treponema pallidum particle agglutination assay [TP-PA]). MHA-TP and FTA-ABS were less sensitive in primary and secondary syphilis than TP-PA; TP-PA is the most specific manual treponemal assay. There is insufficient evidence to recommend one particular treponemal immunoassay (eg, enzyme immunoassays, chemiluminescence immunoassays, microbead immunoassays) over another based on published performance data. For diagnosis of neurosyphilis, cerebrospinal fluid (CSF) TP-PA has similar performance to CSF FTA-ABS in studies with patients with definitive or presumptive neurosyphilis. However, CSF treponemal testing has limitations in its sensitivity and specificity and should be interpreted within the context of the clinical scenario, additional CSF test results and syphilis prevalence.
Topics: Antibodies, Bacterial; Humans; Neurosyphilis; Sensitivity and Specificity; Syphilis; Syphilis Serodiagnosis; Treponema pallidum
PubMed: 32578866
DOI: 10.1093/cid/ciaa349 -
Clinical Microbiology and Infection :... Jan 2022Pneumocystis jirovecii pneumonia (PCP) is an opportunistic infection commonly affecting immunocompromised people. Diagnosis usually requires invasive techniques to... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Pneumocystis jirovecii pneumonia (PCP) is an opportunistic infection commonly affecting immunocompromised people. Diagnosis usually requires invasive techniques to obtain respiratory specimens. Minimally invasive detection tests have been proposed, but their operating characteristics are poorly described.
OBJECTIVES
To systematically review and meta-analyse the performance of minimally invasive PCP detection tests to inform diagnostic algorithms.
DATA SOURCES
Medline, Embase, Cochrane Library (inception to 15 October 2020).
STUDY ELIGIBILITY CRITERIA
Studies of minimally invasive PCP detection tests were included if they contained a minimum of ten PCP cases.
PARTICIPANTS
Adults at risk of PCP.
TESTS
Non-invasive PCP detection tests.
REFERENCE STANDARD
Diagnosis using the combination of clinical and radiographical features with invasive sampling.
ASSESSMENT OF RISK BIAS
Using the QUADAS-2 tool.
METHODS
We used bivariate and, when necessary, univariate analysis models to estimate diagnostic test sensitivity and specificity.
RESULTS
Fifty-two studies were included; most studies (40) comprised exclusively human immunodeficiency virus (HIV) -infected individuals; nine were mixed (HIV and non-HIV), two were non-HIV and one study did not report HIV status. Sampling sites included induced sputum, nasopharyngeal aspirate, oral wash and blood. The four testing modalities evaluated were cytological staining, fluorescent antibody, PCR and lactate dehydrogenase. Induced sputum had the most data available; this modality was both highly sensitive at 99% (95% CI 51%-100%) and specific at 96% (95% CI 88%-99%). Induced sputum cytological staining had moderate sensitivity at 50% (95% CI 39%-61%) and high specificity at 100% (95% CI 100%-100%), as did fluorescent antibody testing with sensitivity 74% (95% CI 62%-87%) and specificity 100% (95% CI 91%-100%).
CONCLUSION
There are several promising minimally invasive PCP diagnostic tests available, some of which may reduce the need for invasive respiratory sampling. Understanding the operating characteristics of these tests can augment current diagnostic strategies and help establish a more confident clinical diagnosis of PCP. Further studies in non-HIV infected populations are needed.
Topics: Adult; HIV Infections; Humans; Immunocompromised Host; Pneumocystis carinii; Pneumonia, Pneumocystis; Sensitivity and Specificity; Sputum
PubMed: 34464734
DOI: 10.1016/j.cmi.2021.08.017 -
Frontiers in Immunology 2021Bispecific antibodies (BsAbs) are antibodies with two binding sites directed at two different antigens or two different epitopes on the same antigen. The clinical...
Bispecific antibodies (BsAbs) are antibodies with two binding sites directed at two different antigens or two different epitopes on the same antigen. The clinical therapeutic effects of BsAbs are superior to those of monoclonal antibodies (MoAbs), with broad applications for tumor immunotherapy as well as for the treatment of other diseases. Recently, with progress in antibody or protein engineering and recombinant DNA technology, various platforms for generating different types of BsAbs based on novel strategies, for various uses, have been established. More than 30 mature commercial technology platforms have been used to create and develop BsAbs based on the heterologous recombination of heavy chains and matching of light chains. The detailed mechanisms of clinical/therapeutic action have been demonstrated with these different types of BsAbs. Three kinds of BsAbs have received market approval, and more than 110 types of BsAbs are at various stages of clinical trials. In this paper, we elaborate on the classic platforms, mechanisms, and applications of BsAbs. We hope that this review can stimulate new ideas for the development of BsAbs and improve current clinical strategies.
Topics: Animals; Antibodies, Bispecific; Antibody Specificity; Binding Sites, Antibody; Biotechnology; Drug Design; Epitopes; Humans; Immunotherapy; Protein Engineering; Recombinant Proteins; Translational Research, Biomedical
PubMed: 34025638
DOI: 10.3389/fimmu.2021.626616 -
The Cochrane Database of Systematic... Nov 2022The diagnostic challenges associated with the COVID-19 pandemic resulted in rapid development of diagnostic test methods for detecting SARS-CoV-2 infection. Serology... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The diagnostic challenges associated with the COVID-19 pandemic resulted in rapid development of diagnostic test methods for detecting SARS-CoV-2 infection. Serology tests to detect the presence of antibodies to SARS-CoV-2 enable detection of past infection and may detect cases of SARS-CoV-2 infection that were missed by earlier diagnostic tests. Understanding the diagnostic accuracy of serology tests for SARS-CoV-2 infection may enable development of effective diagnostic and management pathways, inform public health management decisions and understanding of SARS-CoV-2 epidemiology.
OBJECTIVES
To assess the accuracy of antibody tests, firstly, to determine if a person presenting in the community, or in primary or secondary care has current SARS-CoV-2 infection according to time after onset of infection and, secondly, to determine if a person has previously been infected with SARS-CoV-2. Sources of heterogeneity investigated included: timing of test, test method, SARS-CoV-2 antigen used, test brand, and reference standard for non-SARS-CoV-2 cases.
SEARCH METHODS
The COVID-19 Open Access Project living evidence database from the University of Bern (which includes daily updates from PubMed and Embase and preprints from medRxiv and bioRxiv) was searched on 30 September 2020. We included additional publications from the Evidence for Policy and Practice Information and Co-ordinating Centre (EPPI-Centre) 'COVID-19: Living map of the evidence' and the Norwegian Institute of Public Health 'NIPH systematic and living map on COVID-19 evidence'. We did not apply language restrictions.
SELECTION CRITERIA
We included test accuracy studies of any design that evaluated commercially produced serology tests, targeting IgG, IgM, IgA alone, or in combination. Studies must have provided data for sensitivity, that could be allocated to a predefined time period after onset of symptoms, or after a positive RT-PCR test. Small studies with fewer than 25 SARS-CoV-2 infection cases were excluded. We included any reference standard to define the presence or absence of SARS-CoV-2 (including reverse transcription polymerase chain reaction tests (RT-PCR), clinical diagnostic criteria, and pre-pandemic samples).
DATA COLLECTION AND ANALYSIS
We use standard screening procedures with three reviewers. Quality assessment (using the QUADAS-2 tool) and numeric study results were extracted independently by two people. Other study characteristics were extracted by one reviewer and checked by a second. We present sensitivity and specificity with 95% confidence intervals (CIs) for each test and, for meta-analysis, we fitted univariate random-effects logistic regression models for sensitivity by eligible time period and for specificity by reference standard group. Heterogeneity was investigated by including indicator variables in the random-effects logistic regression models. We tabulated results by test manufacturer and summarised results for tests that were evaluated in 200 or more samples and that met a modification of UK Medicines and Healthcare products Regulatory Agency (MHRA) target performance criteria.
MAIN RESULTS
We included 178 separate studies (described in 177 study reports, with 45 as pre-prints) providing 527 test evaluations. The studies included 64,688 samples including 25,724 from people with confirmed SARS-CoV-2; most compared the accuracy of two or more assays (102/178, 57%). Participants with confirmed SARS-CoV-2 infection were most commonly hospital inpatients (78/178, 44%), and pre-pandemic samples were used by 45% (81/178) to estimate specificity. Over two-thirds of studies recruited participants based on known SARS-CoV-2 infection status (123/178, 69%). All studies were conducted prior to the introduction of SARS-CoV-2 vaccines and present data for naturally acquired antibody responses. Seventy-nine percent (141/178) of studies reported sensitivity by week after symptom onset and 66% (117/178) for convalescent phase infection. Studies evaluated enzyme-linked immunosorbent assays (ELISA) (165/527; 31%), chemiluminescent assays (CLIA) (167/527; 32%) or lateral flow assays (LFA) (188/527; 36%). Risk of bias was high because of participant selection (172, 97%); application and interpretation of the index test (35, 20%); weaknesses in the reference standard (38, 21%); and issues related to participant flow and timing (148, 82%). We judged that there were high concerns about the applicability of the evidence related to participants in 170 (96%) studies, and about the applicability of the reference standard in 162 (91%) studies. Average sensitivities for current SARS-CoV-2 infection increased by week after onset for all target antibodies. Average sensitivity for the combination of either IgG or IgM was 41.1% in week one (95% CI 38.1 to 44.2; 103 evaluations; 3881 samples, 1593 cases), 74.9% in week two (95% CI 72.4 to 77.3; 96 evaluations, 3948 samples, 2904 cases) and 88.0% by week three after onset of symptoms (95% CI 86.3 to 89.5; 103 evaluations, 2929 samples, 2571 cases). Average sensitivity during the convalescent phase of infection (up to a maximum of 100 days since onset of symptoms, where reported) was 89.8% for IgG (95% CI 88.5 to 90.9; 253 evaluations, 16,846 samples, 14,183 cases), 92.9% for IgG or IgM combined (95% CI 91.0 to 94.4; 108 evaluations, 3571 samples, 3206 cases) and 94.3% for total antibodies (95% CI 92.8 to 95.5; 58 evaluations, 7063 samples, 6652 cases). Average sensitivities for IgM alone followed a similar pattern but were of a lower test accuracy in every time slot. Average specificities were consistently high and precise, particularly for pre-pandemic samples which provide the least biased estimates of specificity (ranging from 98.6% for IgM to 99.8% for total antibodies). Subgroup analyses suggested small differences in sensitivity and specificity by test technology however heterogeneity in study results, timing of sample collection, and smaller sample numbers in some groups made comparisons difficult. For IgG, CLIAs were the most sensitive (convalescent-phase infection) and specific (pre-pandemic samples) compared to both ELISAs and LFAs (P < 0.001 for differences across test methods). The antigen(s) used (whether from the Spike-protein or nucleocapsid) appeared to have some effect on average sensitivity in the first weeks after onset but there was no clear evidence of an effect during convalescent-phase infection. Investigations of test performance by brand showed considerable variation in sensitivity between tests, and in results between studies evaluating the same test. For tests that were evaluated in 200 or more samples, the lower bound of the 95% CI for sensitivity was 90% or more for only a small number of tests (IgG, n = 5; IgG or IgM, n = 1; total antibodies, n = 4). More test brands met the MHRA minimum criteria for specificity of 98% or above (IgG, n = 16; IgG or IgM, n = 5; total antibodies, n = 7). Seven assays met the specified criteria for both sensitivity and specificity. In a low-prevalence (2%) setting, where antibody testing is used to diagnose COVID-19 in people with symptoms but who have had a negative PCR test, we would anticipate that 1 (1 to 2) case would be missed and 8 (5 to 15) would be falsely positive in 1000 people undergoing IgG or IgM testing in week three after onset of SARS-CoV-2 infection. In a seroprevalence survey, where prevalence of prior infection is 50%, we would anticipate that 51 (46 to 58) cases would be missed and 6 (5 to 7) would be falsely positive in 1000 people having IgG tests during the convalescent phase (21 to 100 days post-symptom onset or post-positive PCR) of SARS-CoV-2 infection.
AUTHORS' CONCLUSIONS
Some antibody tests could be a useful diagnostic tool for those in whom molecular- or antigen-based tests have failed to detect the SARS-CoV-2 virus, including in those with ongoing symptoms of acute infection (from week three onwards) or those presenting with post-acute sequelae of COVID-19. However, antibody tests have an increasing likelihood of detecting an immune response to infection as time since onset of infection progresses and have demonstrated adequate performance for detection of prior infection for sero-epidemiological purposes. The applicability of results for detection of vaccination-induced antibodies is uncertain.
Topics: Humans; SARS-CoV-2; COVID-19; Antibodies, Viral; Immunoglobulin G; COVID-19 Vaccines; Pandemics; Seroepidemiologic Studies; Immunoglobulin M
PubMed: 36394900
DOI: 10.1002/14651858.CD013652.pub2 -
Autoimmunity Reviews Jan 2021The testing of anti-neutrophil cytoplasmic antibodies (ANCA) takes an important place in the diagnostic workup to ANCA-associated vasculitis (AAV). Nowadays, it is... (Meta-Analysis)
Meta-Analysis
The testing of anti-neutrophil cytoplasmic antibodies (ANCA) takes an important place in the diagnostic workup to ANCA-associated vasculitis (AAV). Nowadays, it is recommended to screen for the presence of PR3 and MPO specific antibodies first using immunoassay, without the need for ANCA measurement by indirect immunofluorescence (IIF). A literature search was performed to assess the diagnostic test value of ANCA IIF and PR3- and MPO-antibody immunoassay to diagnose AAV. This meta-analysis shows that the c-ANCA testing by IIF has a pooled sensitivity of 75.2% and a pooled specificity of 98.4%. For PR3-antibody immunoassay, the pooled sensitivity depended on the immunoassay method used, and ranged from 79.8% to 86.6%, whereas the pooled specificity ranged from 96.8% to 98.3%. For both p-ANCA IIF and MPO-antibody immunoassay (all methods) sensitivity varied considerably showing pooled values of respectively 46.3% and 58.1%, whereas respective pooled specificity was 91.4% and 95.6%. These findings support the 2017 international consensus that primary anti-PR3 and anti-MPO screening by immunoassay, based on superior immunoassay sensitivity without the need for IIF ANCA testing, improves the diagnostic workup of AAV.
Topics: Anti-Neutrophil Cytoplasmic Antibody-Associated Vasculitis; Antibodies, Antineutrophil Cytoplasmic; Enzyme-Linked Immunosorbent Assay; Fluorescent Antibody Technique, Indirect; Humans; Immunoassay; Myeloblastin; Peroxidase
PubMed: 33197574
DOI: 10.1016/j.autrev.2020.102716 -
Current Pharmaceutical Biotechnology 2022Antibody-based therapeutics have been shown to be promising for the treatment of colorectal cancer patients. However, the size and long-circulating half-lives of...
BACKGROUND AND AIMS
Antibody-based therapeutics have been shown to be promising for the treatment of colorectal cancer patients. However, the size and long-circulating half-lives of antibodies can limit their reproducible manufacture in clinical studies. Consequently, in novel therapeutic approaches, conventional antibodies are minimized and engineered to produce fragments like Fab, scFv, nanobody, bifunctional antibody, bispecific antibody, minibody, and diabody to preserve their high affinity and specificity to target pharmaceutical nanoparticle conjugates. This systematic review for the first time aimed to elucidate the role of various antibody fragments in colorectal cancer treatment.
METHODS
A systematic literature search in the web of sciences, PubMed, Scopus, Google Scholar, and ProQuest was conducted. Reference lists of the articles were reviewed to identify the relevant papers. The full-text search included articles published in English during 19902021.
RESULTS
Most of the 53 included studies were conducted in vitro and in most conducted studies singlechain antibodies were among the most used antibody fragments. Most antibodies targeted CEA in the treatment of colorectal cancer. Moreover, a large number of studies observed apoptosis induction and tumor growth inhibition. In addition, few studies implicated the role of the innate immune system as an indirect mechanism of tumor growth by enhancing NK-cell killing.
CONCLUSION
Antibody-based therapy was demonstrated to be of great promise in the treatment of colorectal cancer rather than common treatments such as radiotherapy, chemotherapy, and surgical operations. This type of specified cancer treatment can also induce the activation of the innate and specific immune systems to eradicate tumor cells.
Topics: Antibodies, Bispecific; Antigens; Colorectal Neoplasms; Humans; Immunoglobulin Fragments; Killer Cells, Natural; Nanoparticles
PubMed: 34375187
DOI: 10.2174/1389201022666210810104226 -
The Journal of Infectious Diseases Nov 2023Adding additional specimen types (eg, serology or sputum) to nasopharyngeal swab (NPS) reverse transcription polymerase chain reaction (RT-PCR) increases respiratory... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Adding additional specimen types (eg, serology or sputum) to nasopharyngeal swab (NPS) reverse transcription polymerase chain reaction (RT-PCR) increases respiratory syncytial virus (RSV) detection among adults. We assessed if a similar increase occurs in children and quantified underascertainment associated with diagnostic testing.
METHODS
We searched databases for studies involving RSV detection in persons <18 years using ≥2 specimen types or tests. We assessed study quality using a validated checklist. We pooled detection rates by specimen and diagnostic tests and quantified performance.
RESULTS
We included 157 studies. Added testing of additional specimens to NP aspirate (NPA), NPS, and/or nasal swab (NS) RT-PCR resulted in statistically nonsignificant increases in RSV detection. Adding paired serology testing increased RSV detection by 10%, NS by 8%, oropharyngeal swabs by 5%, and NPS by 1%. Compared to RT-PCR, direct fluorescence antibody tests, viral culture, and rapid antigen tests were 87%, 76%, and 74% sensitive, respectively (pooled specificities all ≥98%). Pooled sensitivity of multiplex versus singleplex RT-PCR was 96%.
CONCLUSIONS
RT-PCR was the most sensitive pediatric RSV diagnostic test. Adding multiple specimens did not substantially increase RSV detection, but even small proportional increases could result in meaningful changes in burden estimates. The synergistic effect of adding multiple specimens should be evaluated.
Topics: Adult; Child; Humans; Respiratory Syncytial Virus Infections; Sensitivity and Specificity; Respiratory Syncytial Virus, Human; Viruses; Diagnostic Techniques and Procedures; Nasopharynx; Reverse Transcriptase Polymerase Chain Reaction
PubMed: 37285396
DOI: 10.1093/infdis/jiad185 -
Seminars in Arthritis and Rheumatism Feb 2021There is still an unmet need for a simple and reliable biomarker for the diagnosis of spondyloarthritis. Recent studies indicated that anti-CD74 antibody could act as a... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
There is still an unmet need for a simple and reliable biomarker for the diagnosis of spondyloarthritis. Recent studies indicated that anti-CD74 antibody could act as a biomarker for spondyloarthritis. Therefore, this review aims to evaluate the levels of anti-CD74 IgG and IgA antibodies in spondyloarthritis and the diagnostic value of anti-CD74 antibodies.
METHODS
PubMed, Web of Science and Medline were comprehensively searched from inception to August 7th, 2019. The pooled standard mean difference (SMD) with 95% confidence interval (CI) was used to estimate the differences of the levels of anti-CD74 IgG and IgA antibodies between spondyloarthritis patients and controls. Sensitivity, specificity and summary receiver operating characteristics (SROC) curve were used for evaluating the diagnostic value of anti-CD74 antibodies. The use of fixed-effect or random-effects model depended on heterogeneity.
RESULTS
Among 55 searched studies, 9 studies were finally included for analysis. Anti-CD74 IgG and IgA antibodies were both significantly increased in spondyloarthritis patients compared with matched controls (IgG: SMD = 0.88, 95% CI = 0.55 to 1.21; IgA: SMD = 0.98, 95% CI = 0.68 to 1.28). The pooled sensitivity, specificity and area under the SROC curve of anti-CD74 IgG antibodies were 0.61, 0.90 and 0.8881, while these indicators of anti-CD74 IgA antibodies were 0.59, 0.95 and 0.8671, respectively.
CONCLUSION
Anti-CD74 IgG and IgA antibodies were significantly increased in spondyloarthritis patients and suggest a high diagnostic specificity of spondyloarthritis. Anti-CD74 antibody could potentially be a biomarker for the diagnosis of spondyloarthritis, but many open questions remain.
Topics: Autoantibodies; Biomarkers; Humans; Immunoglobulin A; ROC Curve; Spondylarthritis
PubMed: 33340822
DOI: 10.1016/j.semarthrit.2020.12.002 -
Clinical Microbiology and Infection :... Sep 2021Appropriate laboratory diagnostics for emerging arboviruses are key for patient management, surveillance and intervention, including molecular tests and serological...
BACKGROUND
Appropriate laboratory diagnostics for emerging arboviruses are key for patient management, surveillance and intervention, including molecular tests and serological tests detecting viral antigen or virus-specific antibodies.
OBJECTIVES
We provide an overview of the challenges towards serological testing for the most important emerging arboviruses, including Zika, dengue and chikungunya viruses.
SOURCES
We retrieved a data set on performance of commercially available antibody- and antigen-detecting tests from 89 peer-reviewed articles conducting a systematic literature research in PubMed.
CONTENT
We identified commonly used antibody- and antigen-detecting tests and analysed their overall performance. We discuss how timing of serological testing and the use of paired samples from acute and convalescent phases of infection are crucial to optimize diagnostic sensitivity and specificity. We then exemplify how serological diagnostics are challenged by the patient's infection history through the 'original antigenic sin' and cross-reactive antibodies in the context of global co-circulation of antigenically related viruses. We highlight how individual infection histories with different arboviruses and with other pathogens such as herpes viruses and Plasmodia can produce inaccurate test results. We show that rapid tests for antibody and antigen detection in point-of-care settings have a significantly lower sensitivity compared with laboratory-based tests such as ELISA. We show that the performance of antibody- and antigen-detecting tests varies greatly between tropical regions of endemic transmission and non-endemic regions. Finally, we highlight that test sensitivity and specificity have to be equilibrated carefully and frequently either of them must be prioritized over the other, depending on disease prevalence and intended use of tests.
IMPLICATIONS
For reliable serological diagnostics, it is essential to be aware of inherent test limitations. Although multiplexed testing and testing of convalescence samples can improve diagnostic performance, global spread of (re-)emerging viruses requires careful implementation and evaluation of serological testing and unambiguous results may not always be achievable.
Topics: Antibodies, Viral; Antigens, Viral; Arbovirus Infections; Arboviruses; Humans; Sensitivity and Specificity; Serologic Tests
PubMed: 34111589
DOI: 10.1016/j.cmi.2021.05.047 -
Archives of Medical Science : AMS 2022The rapid transmission of coronavirus disease 2019 (COVID-19) requires a fast, accurate, and affordable detection method. Despite doubts of their diagnostic accuracy,... (Review)
Review
INTRODUCTION
The rapid transmission of coronavirus disease 2019 (COVID-19) requires a fast, accurate, and affordable detection method. Despite doubts of their diagnostic accuracy, rapid diagnostic tests (RDTs) are used worldwide due to their practicality. This systematic review aims to determine the diagnostic accuracy of antibody-based RDTs in detecting COVID-19.
MATERIAL AND METHODS
A literature search was carried out on five journal databases using the PRISMA-P 2015 method. We included all studies published up to February 2021. The risk of bias was evaluated using the Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Diagnostic Test Accuracy Studies. Data regarding peer-review status, study design, test kit information, immunoglobulin class, target antigen, and the number of samples were extracted and tabulated. We estimated the pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with a 95% confidence interval.
RESULTS
Thirty-three studies met the eligibility criteria. The pooled data results showed that the combined detection method of IgM or IgG had the highest sensitivity and NPV, which were 73.41% (95% CI: 72.22-74.57) and 75.34% (95% CI: 74.51-76.16), respectively. The single IgG detection method had the highest specificity and PPV of 96.68% (95% CI: 96.25-97.07) and 95.97% (95% CI: 95.47-96.42%), respectively.
CONCLUSIONS
Antibody-based RDTs are not satisfactory as primary diagnostic tests but have utility as a screening tool.
PubMed: 35832707
DOI: 10.5114/aoms/135910