Materials (Basel, Switzerland) Sep 2021(1) Background: Hypersensitivity reactions to metals may arise in predisposed patients chronically exposed to metallic materials, including dental implants made of... (Review)
Review
(1) Background: Hypersensitivity reactions to metals may arise in predisposed patients chronically exposed to metallic materials, including dental implants made of titanium alloys. The purpose of this article was to systematically review titanium allergy manifestations in patients treated with dental implants and report a clinical case; (2) Methods: A systematic electronic search was performed for articles published in the English language until July 2021. The following eligibility criteria were adopted: (1) Population: individuals undergoing titanium and/or titanium alloy implant-supported rehabilitations; (2) Exposure: peri-implant soft tissue reactions attributable to implant insertion; (3) Outcome: evidence of titanium allergy, diagnostic methods, and forms of resolution; (3) Results: The included studies, in summary, presented evidence that titanium should not be considered an inert material, being able to trigger allergic reactions, and may be responsible for implant failure. A 55-year-old male patient received 3 implants in the posterior region of the left mandible and presented an epulis-like lesion developed from the peri-implant mucosa. The immunohistochemical analysis of the biopsy specimen confirmed the initial diagnosis of allergic reaction to titanium; (4) Conclusions: Although the evidence is weak, and titanium allergy has a low incidence, hypersensitivity reactions should not be underestimated. A rapid and conclusive diagnosis is mandatory to prevent further complications.
PubMed: 34576463
DOI: 10.3390/ma14185239 -
Clinical Oral Implants Research Sep 2023In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year?
MATERIALS AND METHODS
This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487).
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material.
CONCLUSIONS
Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.
Topics: Humans; Titanium; Dental Implants; Alloys; Aluminum Oxide
PubMed: 37750527
DOI: 10.1111/clr.14159 -
Materials (Basel, Switzerland) Mar 2022In recent years, implantology has made significant progress, as it has now become a safe and predictable practice. The development of new geometries, primary and... (Review)
Review
In recent years, implantology has made significant progress, as it has now become a safe and predictable practice. The development of new geometries, primary and secondary, of new surfaces and alloys, has made this possible. The purpose of this review is to analyze the different alloys present on the market, such as that in zirconia, and evaluate their clinical differences with those most commonly used, such as those in grade IV titanium. The review, conducted on major scientific databases such as Scopus, PubMed, Web of Science and MDPI yielded a startling number of 305 results. After the application of the filters and the evaluation of the results in the review, only 10 Randomized Clinical Trials (RCTs) were included. Multiple outcomes were considered, such as Marginal Bone Level (MBL), Bleeding on Probing (BoP), Survival Rate, Success Rate and parameters related to aesthetic and prosthetic factors. There are currently no statistically significant differences between the use of zirconia implants and titanium implants, neither for fixed prosthetic restorations nor for overdenture restorations. Only the cases reported complain about the rigidity and, therefore, the possibility of fracture of the zirconium. Certainly the continuous improvement in these materials will ensure that they could be used safely while maintaining their high aesthetic performance.
PubMed: 35269211
DOI: 10.3390/ma15051979 -
Clinical Oral Investigations Dec 2023To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
METHODS
An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done.
RESULTS
Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up.
CONCLUSION
Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055).
CLINICAL RELEVANCE
The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Topics: Humans; Dental Implants; Treatment Outcome; Dental Restoration Failure; Zirconium; Titanium; Dental Prosthesis Design
PubMed: 38135804
DOI: 10.1007/s00784-023-05401-8 -
Spine Deformity Nov 2022To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery.
METHODS
A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies.
RESULTS
Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt-chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°-55.42°] and Ti 32.58° [24.62°-40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°-29.53°] and Ti 20.15° [18.0°-22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7-22%) for CoCr and 12% (- 8-32%) for stainless steel (SS) (n = 2 studies each; Chi = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1-22%) for Ti (n = 3 studies) and 10% (2-19) for CoCr (n = 1 study). Among 6.0-6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°-14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°-40.62°), and pelvic tilt angle was 21.11° (18.35°-23.86°).
CONCLUSIONS
For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided.
LEVEL OF EVIDENCE
III.
Topics: Adult; Humans; Spinal Fusion; Stainless Steel; Titanium; Chromium Alloys; Pseudarthrosis; Cobalt; Chromium
PubMed: 35904725
DOI: 10.1007/s43390-022-00556-y -
Journal of Orthodontic Science 2023A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we... (Review)
Review
A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we aimed to assess the various metallurgical characteristics of the said metals and alloys. Four hundred and eighty-two documents in total were found after a thorough search of the online journals, and 169 of the papers were initially chosen. Ultimately, 16 documents were selected that satisfied the necessary inclusion and exclusion criteria, primarily studies, literature reviews, and comparative analyses. NiTi alloy was found to be the most commonly used alloy in construction of orthodontic wires across all the studies that we had selected for our review. It also had better performance and consistency in terms of its usage as depicted by the meta-analysis performed, with stainless steel wires being a close second primarily due to its lesser cost compared to the former. Metallurgy and orthodontics are inextricably linked with one another. The various components of orthodontics such as wires, pliers, and other instruments utilize the metallurgical characteristics of metals and alloys that are specially prepared for the challenges of this field. CRD42022378444.
PubMed: 37881657
DOI: 10.4103/jos.jos_52_23 -
Journal of International Society of... 2020Dental implants are considered the best treatment option for replacement of missing teeth due to high survival rates and diverse applications. However, not all dental... (Review)
Review
BACKGROUND
Dental implants are considered the best treatment option for replacement of missing teeth due to high survival rates and diverse applications. However, not all dental implant therapies are successful and some fail due to various biological and or/mechanical factors. The objective of this study was to systematically review primary studies that focus on the biomechanical properties of dental implants in order to determine which biomechanical properties are most important for success of dental implant therapy.
MATERIALS AND METHODS
An electronic database search was performed using MEDLINE (PubMed), EMBASE, Google Scholar, and CAB Abstracts. Six principal biomechanical properties were considered to prepare the search strategy for each database using key words and Boolean operators. Human and animal studies (observational studies, trials, and studies) were included in this review. Human studies that were considered eligible needed to have subjects above 18 years who received permanent restorations after implant surgery and followed up for at least 6 months after receiving permanent restorations. Studies with subjects who had absolute contraindications at the time of dental implant surgery were excluded.
RESULTS
In total, 28 studies were included in the review after application of the eligibility criteria; 18 studies, 5 cohort clinical studies, 3 animal studies, and 2 nonrandomized trials. Six studies assessed loss of preload, five studies assessed fatigue strength, four assessed implant abutment connection design, and one assessed implant diameter. Two nonrandomized trials assessed torque and six observational studies assessed the effect of cantilevers. Gold alloy coating of abutment screws resulted in higher preload values followed by titanium alloy coating and gold coating; there was a difference in preload values between coated and uncoated screws when tightened repeatedly. Preload values decreased as a function of time with majority of preload loss occurred within 10s of tightening. The 8-degree internal conical implant performed better than the internal hex design. Higher rate of complications (porcelain chipping, de-cementation) was observed in the cantilever groups in studies.
CONCLUSION
Biomechanical properties of implants like preload, torque, cantilever design, implant abutment design have profound effects on the survival rates of dental implants. With limiations, this review provides some important parameters to consider for successful implant therapy.
PubMed: 33437702
DOI: 10.4103/jispcd.JISPCD_138_20 -
Journal of Esthetic and Restorative... Dec 2023The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. (Review)
Review
OBJECTIVE
The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning.
MATERIALS AND METHODS
An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded.
RESULTS
A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications.
CONCLUSIONS
The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions.
CLINICAL SIGNIFICANCE
ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Topics: Dental Implants; Dental Impression Technique; Computer-Aided Design; Research Design; Imaging, Three-Dimensional
PubMed: 37381677
DOI: 10.1111/jerd.13074 -
Clinical and Experimental Dental... Aug 2022This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces. (Review)
Review
OBJECTIVES
This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces.
MATERIAL AND METHODS
An electronic search for literature was conducted on PubMed, Embase, Scopus, and Web of Science and a total of 14 studies were included. Neutrophil responses were assessed based on adhesion, cell number, surface coverage, cell structure, cytokine secretion, reactive oxygen species (ROS) production, neutrophil activation, receptor expression, and neutrophil extracellular traps (NETs) release. The method of assessing the risk of bias was done using the toxicological data reliability assessment tool (TOXRTOOL).
RESULTS
Ten studies have identified a significant increase in neutrophil functions, such as surface coverage, cell adhesion, ROS production, and NETs released when interacting with rough titanium surfaces. Moreover, neutrophil interaction with rough-hydrophilic surfaces seems to produce less proinflammatory cytokines and ROS when compared to naive smooth and rough titanium surfaces. Regarding membrane receptor expression, two studies have reported that the FcγIII receptor (CD16) is responsible for initial neutrophil adhesion to hydrophilic titanium surfaces. Only one study compared neutrophil interaction with titanium alloy and zirconia toughened alumina surfaces and reported no significant differences in neutrophil cell count, activation, receptor expression, and death.
CONCLUSIONS
There are not enough studies to conclude neutrophil interactions with titanium and zirconia surfaces. However, different topographic modifications such as roughness and hydrophilicity might influence neutrophil interactions with titanium implant surfaces.
Topics: Dental Implants; Neutrophils; Reactive Oxygen Species; Reproducibility of Results; Surface Properties; Titanium; Zirconium
PubMed: 35535662
DOI: 10.1002/cre2.582 -
The Journal of Prosthetic Dentistry Oct 2022Selective laser melting (SLM) additive manufacturing (AM) technologies provide an alternative to conventional casting and milling procedures in fabricating metal-ceramic... (Meta-Analysis)
Meta-Analysis Review
Adhesion of veneering porcelain to cobalt-chromium dental alloys processed with casting, milling, and additive manufacturing methods: A systematic review and meta-analysis.
STATEMENT OF PROBLEM
Selective laser melting (SLM) additive manufacturing (AM) technologies provide an alternative to conventional casting and milling procedures in fabricating metal-ceramic dental prostheses. However, the quality of porcelain bond strength to the SLM AM cobalt-chromium (Co-Cr) metal framework of a dental restoration is unclear.
PURPOSE
The purpose of this systematic review and meta-analysis was to identify in vitro studies that reported the porcelain bond strength to SLM AM Co-Cr dental metal alloys and compare the porcelain bond strength values to cast, milled, and additively manufactured Co-Cr dental alloys.
MATERIAL AND METHODS
An electronic systematic review was performed in different databases: MEDLINE/PubMed, EMBASE, World of Science, Cochrane, and Scopus. A manual search was also conducted. Studies that reported the porcelain bond strength to SLM Co-Cr metal alloys and in the English language were included. Two investigators evaluated the quality assessment of the studies by applying the JBI critical appraisal checklist for quasi-experimental studies (nonrandomized experimental studies). A third investigator was consulted to resolve lack of consensus. Two subgroups were created based on the test used, 3-point bend and shear bond strength tests. The porcelain bond strength of cast, milled, and AM Co-Cr dental alloys were compared. The I2 statistic and its associated P value were used to assess the heterogeneity between studies. The Eger test was used for determining significance of the funnel pots.
RESULTS
A total of 216 studies were collected from the electronic and manual searches. After independently evaluating the titles and abstracts by the reviewers, 26 articles were identified. Three of these were excluded after full-text revision. The porcelain bond strength comparison between the cast and AM alloys for the 3-point bend subgroup revealed a significant result for overall effect (P<.001) favoring the SLM method with considerable heterogeneity (I2=83%, P<.001). Furthermore, the porcelain bond strength comparison between cast and milled alloys for the shear bond strength subgroup revealed a significant test for overall effect (P=.04) favoring milled procedures with a nonsignificant unimportant heterogeneity (I2= 0%, P<.47) and for the 3-point bend subgroup (P<.001) favoring milled specimens with a significant considerable heterogeneity (I2=79%, P<.001).
CONCLUSIONS
The metal manufacturing method had no effect on the porcelain bond strength to Co-Cr dental metal alloys.
Topics: Dental Porcelain; Chromium Alloys; Metal Ceramic Alloys; Dental Bonding; Materials Testing; Surface Properties; Cobalt; Chromium; Dental Alloys
PubMed: 34294418
DOI: 10.1016/j.prosdent.2021.01.001