Clinical Oral Investigations Dec 2021The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures... (Review)
Review
OBJECTIVES
The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secondary aim was to verify the effectiveness of IOS procedures based on available prosthodontic outcomes.
MATERIALS AND METHODS
Electronic and manual literature searches were performed to collect evidence concerning the outcomes of IOS and CI performed during the treatment of partially and complete edentulous patients for tooth- or implant-supported restorations. Qualitative analysis was conducted to evaluate the time efficiency and PROMs produced by the two different techniques. Clinical prosthodontic outcomes were analyzed among the included studies when available.
RESULTS
Seventeen studies (9 randomized controlled trials and 8 prospective clinical studies) were selected for qualitative synthesis. The 17 included studies provided data from 430 IOS and 370 CI performed in 437 patients. A total of 7 different IOS systems and their various updated versions were used for digital impressions. The results demonstrated that IOS was overall faster than CI independent of whether quadrant or complete-arch scanning was utilized, regardless of the nature of the restoration (tooth or implant supported). IOS was generally preferred over CI regardless of the size of the scanned area and nature of the restoration (tooth- or implant-supported). Similar prosthodontic outcomes were reported for workflows implementing CI and IOS.
CONCLUSIONS
Within the limitations of this systematic review, IOS is faster than CI, independent of whether a quadrant or complete arch scan is conducted. IOS can improve the patient experience measured by overall preference and comfort and is able to provide reliable prosthodontic outcomes.
CLINICAL RELEVANCE
Reduced procedure working time associated with the use of IOS can improve clinical efficiency and the patient experience during impression procedures. Patient-reported outcome measures (PROMs) are an essential component of evidence-based dental practice as they allow the evaluation of therapeutic modalities from the perspective of the patient. IOS is generally preferred by patients over conventional impressions.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Technique; Humans; Patient Comfort; Prospective Studies; Prosthodontics
PubMed: 34568955
DOI: 10.1007/s00784-021-04157-3 -
Gels (Basel, Switzerland) Mar 2022Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to... (Review)
Review
Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to delayed dentin sealing (DDS), a technique in which hybridization is performed following the provisional phase and just before the indirect restoration luting procedure. This study aimed to compare the bond strength of restorations to dentin of the IDS and the DDS techniques throughout a systematic review and meta-analysis. The following PICOS framework was used: population, indirect restorations; intervention, IDS; control, DDS; outcomes, bond strength; and study design, in vitro studies. PubMed (MedLine), The Cochrane Library, ISI Web of Science, Scielo, Scopus, and Embase were screened up to January 2022 by two reviewers (L.H. and R.B.). In vitro papers studying the bond strength to human dentin of the IDS technique compared to the DDS technique were considered. Meta-analyses were carried out by using a software program (Review Manager v5.4.1; The Cochrane Collaboration). Comparisons were made by considering the adhesive used for bonding (two-step etch-and-rinse, three step etch-and-rinse, one-step self-etch, two-step self-etch, and universal adhesives). A total of 3717 papers were retrieved in all databases. After full-text assessment, 22 potentially eligible studies were examined for qualitative analysis, leaving a total of 21 articles for the meta-analysis. For the immediate bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p < 0.001). Taking into account the subgroup analysis, it seems that the use of the IDS technique with a two-step etch-and-rinse or a one-step self-etch adhesive system does not represent any advantage over the DDS technique (p = 0.07, p = 0.15). On the other hand, for the aged bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p = 0.001). The subgroups analysis shows that this improvement is observed only when a three-step etch-and-rinse adhesive system (p < 0.001) or when a combination of an adhesive system plus a layer of flowable resin (p = 0.01) is used. The in vitro evidence suggests that the use of the IDS technique improves the bond strength of dentin to resin-based restorations regardless of the adhesive strategy used. The use of a three-step etch-and-rinse adhesive system or the combination of an adhesive system plus a layer of flowable resin seems to considerably enhance the bond strength in the long term.
PubMed: 35323288
DOI: 10.3390/gels8030175 -
Clinical Oral Investigations Sep 2022The purpose of this systematic review was to compare the accuracy of digital and conventional full-arch impressions in vivo. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The purpose of this systematic review was to compare the accuracy of digital and conventional full-arch impressions in vivo.
MATERIALS AND METHODS
This systematic review was conducted according to the PRISMA and registered at the PROSPERO (CRD42021232736). Electronic and hand searches were performed to identify in vivo studies comparing the linear or 3D accuracy of digital and conventional impressions. The risk of bias (ROB) of included studies was assessed by QUADAS-2, and the overall quality of evidence was assessed by GRADE.
RESULTS
Twenty-two studies met the inclusion criteria, and 13 studies were included in the meta-analysis. There was no significant difference between digital and conventional impressions in the linear measurements of tooth width, anterior Bolton ratio, overall Bolton ratio, intercanine distance (ICD), and intermolar distance (IMD). The repeated measurement mean errors (RMEs) were less than 0.1 mm, the intra-examiner intraclass correlation coefficient (ICC) values were more than 0.9, and the inter-examiner ICC values were more than 0.87 for both impression techniques. The 3D deviation between digital and alginate impressions was 0.09 mm. The 3D precision of both impression techniques was less than 0.1 mm.
CONCLUSIONS
The trueness of digital and alginate full-arch impressions was similar, and both impression techniques showed high precision. More research was needed to compare digital impressions and other conventional impression materials.
CLINICAL RELEVANCE
For patients with completely natural dentition, the digital impressions obtained directly from intraoral scanning can be considered a viable alternative to alginate impressions.
Topics: Alginates; Computer-Aided Design; Dental Arch; Dental Impression Materials; Dental Impression Technique; Humans; Imaging, Three-Dimensional; Models, Dental
PubMed: 35786783
DOI: 10.1007/s00784-022-04607-6 -
Journal of Prosthodontics : Official... Oct 2020To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant... (Meta-Analysis)
Meta-Analysis
PURPOSE
To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant impressions for partially and completely edentulous patients.
MATERIALS AND METHODS
Electronic and manual searches were conducted to identify in vitro and clinical studies, reporting on the 3D accuracy between digital and conventional implant impressions. Secondary outcomes were the effect of implant angulation, type of conventional impression technique, and type of intraoral scanner on the accuracy of implant impressions.
RESULTS
The inclusion criteria were met by 9 in vitro studies and 1 clinical study reporting on completely edentulous impressions, while 6 in vitro and 2 clinical studies reported on partially edentulous impressions. Quantitative meta-analysis was performed for 5 completely edentulous and 6 partially edentulous studies. The studies exhibited high values for heterogeneity. A random effects model was conducted to estimate the effect size. Based on 5 in vitro studies on completely edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 8.20 µm (95% CI: -53.56, 37.15) and the digital impressions had nominally less deviation (p = 0.72). Based on 1 clinical and 5 in vitro studies on partially edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 52.31 µm (95% CI: 6.30, 98.33) and the conventional impressions had nominally less deviation (p = 0.03). Five in vitro and 2 clinical studies were not included in the quantitative analysis due to heterogeneity in the methodology. Implant angulation affected the accuracy in favor of the partially edentulous conventional impressions whereas the effect of different scanners was not statistically significant on the completely edentulous impressions (p = 0.82).
CONCLUSIONS
Digital scans appear to have comparable 3D accuracy with conventional implant impressions based mainly on in vitro studies. However, clinical trials are recommended to investigate the clinical accuracy of digital scans and digitally fabricated interim or prototype prostheses, before digital implant scans can be recommended for routine clinical use.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Materials; Dental Impression Technique; Humans; Models, Dental; Mouth, Edentulous
PubMed: 32613641
DOI: 10.1111/jopr.13211 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case...
PURPOSE
This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.
STUDY SELECTION
We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis. We report evidence from clinical papers and case reports, digital impression-taking methods, and maxillomandibular relationship (MMR) records.
RESULTS
A case report electronically published in 2019 introduced a clasp-retained RPD fabricated via a full-digital workflow without a gypsum definitive cast. Computer-aided design and computer-aided manufacturing of double-crown-retained RPDs with nonmetal materials were described in some case reports. Intraoral scanners were used to obtain digital impressions and MMR records in the fabrication of digital RPDs, which have potential advantages for reducing the number of clinical appointments and simplifying laboratory procedures. Evidence from clinical trials is scarce; a randomized controlled trial reported higher patient satisfaction with digital clasp-retained RPDs than with conventional RPDs.
CONCLUSIONS
Full-digital RPDs can be fabricated without a gypsum definitive cast. However, the indication for full-digital RPDs is limited to cases with Kennedy Class III/IV partially edentulous arches with several missing teeth. Challenges in digital impression-taking and MMR recording remain to be solved to extend these indications. More evidence from clinical trials is required to evaluate the efficacy and usefulness of digital RPDs.
Topics: Computer-Aided Design; Denture, Partial, Removable; Humans; Mouth, Edentulous; Randomized Controlled Trials as Topic
PubMed: 33504721
DOI: 10.2186/jpr.JPR_D_20_00116 -
Journal of Esthetic and Restorative... Dec 2023The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. (Review)
Review
OBJECTIVE
The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning.
MATERIALS AND METHODS
An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded.
RESULTS
A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications.
CONCLUSIONS
The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions.
CLINICAL SIGNIFICANCE
ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Topics: Dental Implants; Dental Impression Technique; Computer-Aided Design; Research Design; Imaging, Three-Dimensional
PubMed: 37381677
DOI: 10.1111/jerd.13074 -
Bioengineering (Basel, Switzerland) Mar 2022Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants... (Review)
Review
Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants are used; however, no sole disinfectant can be designated as universal for all the impression materials. Thus, the aim of this study is to systemically review the literature to evaluate the effect of the existing disinfection procedures on the bacterial colonization of dental impression materials. This systematic review and meta-analysis was conducted according to the PRISMA statement. PubMed (MEDLINE), Web of Science, Scopus, EMBASE, and SciELO databases were screened up to April 2021. Eligibility criteria included in vitro studies reporting the antibacterial activity of disinfectant solutions in dental impression materials. The meta-analysis was performed using Review Manager (version 5.3.5). A global comparison was performed with the standardized mean difference based on random-effect models at a significance level of α = 0.05. A total of seven studies were included in the meta-analysis. The included studies described the effect of disinfection processes with chlorhexidine gluconate, alcohol, sodium hypochlorite, glutaraldehyde, and hydrogen peroxide in alginate, polyvinyl siloxane, and polyether impression materials. The meta-analyses showed that the use of chlorhexidine, alcohol, glutaraldehyde, and sodium hypochlorite reduced the colony-forming units by a milliliter (CFU/mL) in alginate (p < 0.001). On the other hand, glutaraldehyde, sodium hypochlorite, and alcohol reduced the CFU/mL in polyvinyl siloxane (p < 0.001). Finally, alcohol and glutaraldehyde reduced the CFU/mL in polyether material (p < 0.001). High heterogenicity was observed for the alginate and polyvinyl siloxane materials (I2 = 74%; I2 = 90%). Based on these in vitro studies, the disinfection of impression materials with several disinfection agents reduces the CFU/mL count.
PubMed: 35324812
DOI: 10.3390/bioengineering9030123 -
The Journal of Prosthetic Dentistry Sep 2023Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are... (Review)
Review
STATEMENT OF PROBLEM
Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are currently unknown.
PURPOSE
The purpose of this systematic review was to evaluate the clinical and laboratory procedures for digital complete dentures, their outcomes, and associated complications.
MATERIAL AND METHODS
Electronic literature searches were conducted on PubMed/Medline, Embase, and Web of Science for studies published from January 2000 to September 2022 and screened by 2 independent reviewers. Information on digital complete denture procedures, materials, their outcomes, and associated complications was extracted.
RESULTS
Of 266 screened studies, 39 studies were included. While 26 assessed definitive complete dentures, 7 studies assessed denture bases, 2 assessed trial dentures, and 4 assessed the digital images only. Twenty-four studies used border molded impression technique, 3 studies used a facebow record, and 7 studies used gothic arch tracing. Only 13 studies performed trial denture placement. Twenty-one studies used milling, and 17 studies used 3D printing for denture fabrication. One study reported that the retention of maxillary denture bases fabricated from a border-molded impression (14.5 to 16.1 N) was statistically higher than the retention of those fabricated from intraoral scanning (6.2 to 6.6 N). The maximum occlusal force of digital complete denture wearers was similar across different fabrication procedures. When compared with the conventional workflow, digital complete dentures required statistically shorter clinical time with 205 to 233 minutes saved. Up to 37.5% of participants reported loss of retention and up to 31.3% required a denture remake. In general, ≥1 extra visit and 1 to 4 unscheduled follow-up visits were needed. The outcomes for patient satisfaction and oral health-related quality of life were similar between conventional, milled, and 3D-printed complete dentures.
CONCLUSIONS
Making a border-molded impression is still preferred for better retention, and trial denture placement is still recommended to optimize the fabrication of definitive digital complete dentures.
PubMed: 37689573
DOI: 10.1016/j.prosdent.2023.07.027 -
The Journal of Prosthetic Dentistry Jan 2023Lithium disilicate crowns can be manufactured by computer-aided design and computer-aided manufacturing (CAD-CAM) or with the heat-pressed technique. The outcome of... (Meta-Analysis)
Meta-Analysis Review
STATEMENT OF PROBLEM
Lithium disilicate crowns can be manufactured by computer-aided design and computer-aided manufacturing (CAD-CAM) or with the heat-pressed technique. The outcome of studies comparing the effect of the manufacturing method on the marginal adaptation of these crowns is not clear.
PURPOSE
The purpose of this systematic review and meta-analysis was to investigate the effect of the CAD-CAM system and pressing technique on the marginal adaptation of lithium disilicate crowns.
MATERIAL AND METHODS
This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. A literature research was conducted in MEDLINE via PubMed and Scopus databases, relevant journal sites, and the authors' collected references, from January 2009 to April 2019.
RESULTS
The electronic and manual searches that could be read in full totaled 24 studies; of which, 9 were included in the systematic review and meta-analysis, 7 of which were in vitro and 2 in vivo. Statistical analyses were conducted by using Review Manager software program. Meta-analyses were performed with the random effects model (α=.05). In vitro studies showed no difference in the manufacturing (P>.001; 95% confidence interval -0.687 to 0.632), and no significant difference was found for in vivo studies (P=.7, 95% confidence interval 0.00 to 54.77). In the joint analysis of the in vivo and in vitro articles, there was a significant difference between the manufacturing methods (P<.001).
CONCLUSIONS
Differences were detected between the marginal adaptation of lithium disilicate crowns fabricated with the CAD-CAM system and the pressing technique, but the accuracy values were clinically acceptable.
Topics: Hot Temperature; Dental Prosthesis Design; Dental Impression Technique; Dental Marginal Adaptation; Dental Porcelain; Crowns; Computer-Aided Design
PubMed: 34147239
DOI: 10.1016/j.prosdent.2021.03.021 -
European Journal of Oral Sciences Dec 2022Advances of digital technology are rapidly adopted in dental practice. This systematic review aimed to collect evidence on the accuracy of fit of different types of... (Review)
Review
Advances of digital technology are rapidly adopted in dental practice. This systematic review aimed to collect evidence on the accuracy of fit of different types of fixed dental prostheses (FDPs) fabricated through digital, conventional, or combination impression techniques. Data collection was based on the guidelines of the preferred reporting items for systematic reviews and meta-analyses (PRISMA). Two databases (PubMed, Scopus) were searched for articles in English published between 2010 and 2021 resulting in 480 articles. Of those, 35 studies fulfilled the inclusion criteria. These articles referred to three groups of materials/techniques including all-ceramic (zirconia; lithium disilicate) and porcelain-fused-to-metal (PFM) restorations. Results showed clinically acceptable marginal fit (< 120 μm) for all materials and impression techniques. Α fully digital workflow appears more promising for the construction of short-span zirconia FDPs. Nevertheless, most articles evaluated marginal/internal fit of single crowns or short-span FDPs in vitro, while clinical data are limited for long-span FDPs. The necessity for gingival retraction remains a major drawback of all impression techniques, increasing procedural time and patient discomfort. Besides, factors related to the fabrication process, including milling and 3D printing of working models significantly influence the outcome. Overall, there still some way to go before digital technology can be incorporated in complex treatment plans in prosthodontics.
Topics: Humans; Dental Prosthesis; Dental Restoration, Permanent
PubMed: 36346664
DOI: 10.1111/eos.12902