Clinical Oral Implants Research Sep 2023The aim of this study was to review available evidence for Type 1A (immediate implant placement and immediate loading) of single tooth replacement in the maxillary... (Meta-Analysis)
Meta-Analysis Review
Selection criteria for immediate implant placement and immediate loading for single tooth replacement in the maxillary esthetic zone: A systematic review and meta-analysis.
OBJECTIVES
The aim of this study was to review available evidence for Type 1A (immediate implant placement and immediate loading) of single tooth replacement in the maxillary esthetic zone.
MATERIALS AND METHODS
An electronic search was conducted utilizing the databases of MEDLINE, Embase, and Cochrane to identify publications reporting on the outcomes of Type 1A for single tooth replacement in the maxillary esthetic zone. The success and survival rates of the included articles were reported, which were further categorized according to the clinical criteria reported in Type 1A. Mean survival rates were univariately compared between risk groups and additionally between studies published before and since 2012 using bias-corrected and study size-weighed bootstrap tests. A study time-correcting meta-analysis was then performed to obtain an overall effect for the study pool.
RESULTS
A total of 3118 publications were identified in the search, with a total of 68 articles included. A mean number of implants per study were 37.2 and mean follow-up was 2.8 years. All the included studies utilizing Type 1A report highly selective inclusion and exclusion criteria. Univariate risk group comparison determined that studies before 2012 report a significantly lower mean survival rate (difference of -1.9 percentage points [PP], 95% CI: [-0.3, -4.0], p = .02), facial gap dimension had an impact on survival rates (+3.1 PP [0.2, 5.3] for width >2 mm, p = .04), as well as presence of endodontic infection (+2.6 PP [0.9, 5.1], p = .004).
CONCLUSIONS
Type 1A has a high survival rate in studies reporting strict patient and site selection criteria. Further research is required to assess esthetic and functional success with Type 1A treatments.
Topics: Humans; Patient Selection; Dental Implants; Esthetics, Dental; Databases, Factual
PubMed: 37750515
DOI: 10.1111/clr.14109 -
Journal of Prosthodontics : Official... Oct 2020To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant... (Meta-Analysis)
Meta-Analysis
PURPOSE
To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant impressions for partially and completely edentulous patients.
MATERIALS AND METHODS
Electronic and manual searches were conducted to identify in vitro and clinical studies, reporting on the 3D accuracy between digital and conventional implant impressions. Secondary outcomes were the effect of implant angulation, type of conventional impression technique, and type of intraoral scanner on the accuracy of implant impressions.
RESULTS
The inclusion criteria were met by 9 in vitro studies and 1 clinical study reporting on completely edentulous impressions, while 6 in vitro and 2 clinical studies reported on partially edentulous impressions. Quantitative meta-analysis was performed for 5 completely edentulous and 6 partially edentulous studies. The studies exhibited high values for heterogeneity. A random effects model was conducted to estimate the effect size. Based on 5 in vitro studies on completely edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 8.20 µm (95% CI: -53.56, 37.15) and the digital impressions had nominally less deviation (p = 0.72). Based on 1 clinical and 5 in vitro studies on partially edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 52.31 µm (95% CI: 6.30, 98.33) and the conventional impressions had nominally less deviation (p = 0.03). Five in vitro and 2 clinical studies were not included in the quantitative analysis due to heterogeneity in the methodology. Implant angulation affected the accuracy in favor of the partially edentulous conventional impressions whereas the effect of different scanners was not statistically significant on the completely edentulous impressions (p = 0.82).
CONCLUSIONS
Digital scans appear to have comparable 3D accuracy with conventional implant impressions based mainly on in vitro studies. However, clinical trials are recommended to investigate the clinical accuracy of digital scans and digitally fabricated interim or prototype prostheses, before digital implant scans can be recommended for routine clinical use.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Materials; Dental Impression Technique; Humans; Models, Dental; Mouth, Edentulous
PubMed: 32613641
DOI: 10.1111/jopr.13211 -
The European Journal of Prosthodontics... Nov 2022The objective of this systematic review was to compare the longevity of direct amalgam and composite resin restorations, in posterior teeth, through clinical,...
OBJECTIVES
The objective of this systematic review was to compare the longevity of direct amalgam and composite resin restorations, in posterior teeth, through clinical, prospective or retrospective studies, with at least 5 years of follow-up.
MATERIALS AND METHODS
Studies published in the last 15 years (from 2006 to 2021) were collected using the PubMed and Medline databases.
RESULTS
The search strategy associated with the established inclusion and exclusion criteria resulted in a total of 17 articles. Factors related to failures in the performance of restorations were analyzed together with the clinical performance results of each material over the years of study, according to the methodology of each article.
CONCLUSIONS
Regardless of the restorative material, the successful results over more than 5 years are due much more to the correct application of the technique, the operator's skill/knowledge and factors related to the patient, such as the type of tooth, number of faces involved in the restoration and oral hygiene.
Topics: Humans; Prospective Studies; Retrospective Studies; Composite Resins; Dental Materials
PubMed: 35438266
DOI: 10.1922/EJPRD_2371Maciel09 -
Clinical Oral Implants Research Mar 2023The significance on the association between the peri-implant bucco-lingual dimension (BLD) at the stage of implant placement and the occurrence of biological and... (Review)
Review
BACKGROUND
The significance on the association between the peri-implant bucco-lingual dimension (BLD) at the stage of implant placement and the occurrence of biological and esthetic complications is yet unknown.
MATERIAL AND METHODSS
Systematic screening of electronic sources was carried out to identify clinical and preclinical studies reporting on the baseline BLD and/or buccal bone thickness (BBT) values. A secondary objective was to assess the effect of simultaneous grafting at sites with deficient or no buccal bone wall (BBW) at baseline. The primary outcome variables were BBT, BLD, and buccal vertical bone loss (VBL) at re-evaluation. Moreover, radiographic, clinical, and patient-reported outcome measures (PROMs) were evaluated.
RESULTS
Overall, 12 clinical and four preclinical studies met the inclusion criteria. Inconsistencies were found in defining the critical BBT across the clinical and preclinical data evaluated. The clinical evidence demonstrated that during healing, dimensional changes occur in the alveolar bone and in the BBW that may compromise the integrity of the peri-implant bone, leading to VBL and mucosal recession (MR), particularly in scenarios exhibiting a thin BBW. The preclinical evidence validated the fact that implants placed in the presence of a thin BBW, are more prone to exhibit major dimensional changes and VBL. Moreover, the clinical data supported that, in scenarios where dehiscence-type defects occur and are left for spontaneous healing, greater VBL and MR together with the occurrence of biologic complications are expected. Furthermore, the augmentation of dehiscence-type defects is associated with hard and soft tissue stability. PROMs were not reported.
CONCLUSIONS
Dimensional changes occur as result of implant placement in healed ridges that may lead to instability of the peri-implant hard and soft tissues. Sites presenting a thin BBW are more prone to exhibit major changes that may compromise the integrity of the buccal bone and may lead to biologic and esthetic complications.
Topics: Humans; Dental Implants; Dental Implantation, Endosseous; Wound Healing; Biological Products; Treatment Outcome
PubMed: 36626118
DOI: 10.1111/clr.14029 -
The Journal of Prosthetic Dentistry Apr 2024When restoring endodontically treated teeth, a post system is indicated to retain a core. Clinicians can choose from different post materials and types. However, the... (Meta-Analysis)
Meta-Analysis Review
STATEMENT OF PROBLEM
When restoring endodontically treated teeth, a post system is indicated to retain a core. Clinicians can choose from different post materials and types. However, the literature is inconclusive on the long-term clinical performance of available post systems.
PURPOSE
The purpose of this systematic review and meta-analysis was to analyze the survival and failure rates of endodontically treated teeth restored either with glass-fiber-reinforced or metal posts.
MATERIAL AND METHODS
The research question was formulated by following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines by using the Population, Intervention, Comparison, Outcome, Study Type (PICOS) tool. Medline (PubMed), Embase, and Scopus searches complemented by manual search were performed for randomized controlled clinical trials with a follow-up of at least 2 years. Two independent authors performed screening and data extraction of the articles. Meta-analyses were performed with the RevMan software program. Homogeneity was checked by using chi and I tests, and random-effects meta-analyses were applied. Odds ratio and 95% confidence interval were calculated (α=.05). The publication bias was evaluated by using funnel plots and the Begg and Egger tests.
RESULTS
A total of 184 studies were retrieved through the electronic searches, and an additional 4 through the hand search. After title- and abstract-level exclusion, 23 studies remained for full-text analyses, of which 7 were selected for data extraction. Meta-analyses revealed an overall survival rate of 92.8% for endodontically treated teeth restored with glass-fiber-reinforced posts compared with 78.1% of those restored with metal posts. No statistically significant difference (P>.05) was found in the survival, success, or failure rates.
CONCLUSIONS
No statistically significant differences were found between the survival and failure rates of endodontically treated teeth restored either with glass-fiber-reinforced or metal posts. The overall survival rate was 92.8% for glass fiber posts and 78.1% for metal posts. Both are reliable materials when a significant amount of coronal tooth structure is missing and treatment with a post is indicated.
Topics: Humans; Post and Core Technique; Tooth, Nonvital; Survival Rate; Glass; Metals; Tooth Fractures; Composite Resins
PubMed: 35430048
DOI: 10.1016/j.prosdent.2022.01.003 -
Operative Dentistry Jan 2021Composite resin or ceramic inlays, onlays, and overlays can achieve high long-term survival and success rates. (Meta-Analysis)
Meta-Analysis
CLINICAL RELEVANCE
Composite resin or ceramic inlays, onlays, and overlays can achieve high long-term survival and success rates.
Topics: Ceramics; Composite Resins; Dental Porcelain; Inlays
PubMed: 33882133
DOI: 10.2341/19-107-LIT -
Clinical and Experimental Dental... Dec 2022This systematic review aims to investigate the effect of different preparation designs on the marginal fit and fracture strength of ceramic occlusal veneers. (Review)
Review
OBJECTIVES
This systematic review aims to investigate the effect of different preparation designs on the marginal fit and fracture strength of ceramic occlusal veneers.
MATERIALS AND METHODS
Based on the PICO question and the search terms, an electronic search was performed in Google Scholar, PubMed (MEDLINE), Scopus, Cochrane Library, Web of Science, Science Direct, Wiley, Ovid, and SAGE for articles published up to July 2022. After including English in vitro studies that evaluated posterior ceramic occlusal overlays at the posterior with ceramic restorations by following the PRISMA statement, the extracted data was tabulated. The methodological quality of the included studies was evaluated. Risk of bias assessment was done independently by two authors using the modified MINORS scale.
RESULTS
About 3138 search results were screened, of which 22 were selected due to their titles. Twenty-one full-text articles were assessed for eligibility. Seventeen in-vitro studies were finalized for the extraction of quantitative data. All 17 articles had a low risk of bias and were retained. The influencing items for evaluating the research were different in most studies; therefore, qualitative synthesis of the results was feasible. They generally included preparation design, material thickness, depth of preparation in the tooth, internal divergence angle, and finish line. Meta-analysis was not done due to heterogeneity of preparation types and evaluation methods. Results revealed that fracture resistance of occlusal veneers is higher than normal mastication force, and it is sufficient to prepare the occlusal surface, use a self-etching primer for bonding, and an acceptable minimum ceramic thickness. The marginal discrepancy of occlusal veneers is clinically acceptable. However, this systematic review faces some limitations due to the lack of in vivo studies, different preparation designs in included studies, different follow-ups, and lack of comprehensive explanations in articles.
CONCLUSIONS
The preparation design of occlusal veneers influences both marginal adaptation and fracture resistance. Various preparation designs are proven to have clinically acceptable fracture strength and marginal adaptation.
Topics: Dental Porcelain; Dental Veneers; Flexural Strength; Dental Stress Analysis; Materials Testing; Ceramics
PubMed: 36062841
DOI: 10.1002/cre2.653 -
BMC Oral Health Aug 2023Large cavity designs and access cavities impair endodontically treated tooth fracture resistance. As the tooth's strength is known to reduce significantly after the root...
BACKGROUND
Large cavity designs and access cavities impair endodontically treated tooth fracture resistance. As the tooth's strength is known to reduce significantly after the root canal treatment, occlusal loading as a result of functions such as chewing, biting and certain parafunctional tendencies makes the endodontically treated tooth vulnerable to fracture. Hence, after endodontic treatment, it is vital to give adequate and appropriate restorative material to avoid tooth fractures. Accordingly, the choice of such restorative material should be dictated by the property of fracture resistance.
OBJECTIVE
The goal of this study was to conduct a systematic review and critical analysis of available data from in vitro studies examining the fracture resistance of endodontically treated posterior teeth restored with fiber-reinforced composites.
METHODOLOGY
The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRIS-MA) Statement was used to guide the reporting of this systematic review A comprehensive literature search was performed using MEDLINE (via PubMed), Scopus, ScienceDirect, Google Scholar, and LILACS. A manual search of the reference lists of the articles was also performed. The databases provided a total of 796 studies from the electronic systematic search. The databases provided a total of 796 studies from the electronic systematic search. Two reviewers scrutinized the papers for eligibility based on inclusion/exclusion criteria and extracted data. The studies were assessed for their potential risk of bias. Based on modified JBI & CRIS (checklist for reporting in vitro studies) guidelines, along with the methodology and treatment objective, we have formulated 13 parameters specifically to assess the risk of bias. A total of 18 studies met the inclusion criteria and were included for qualitative analysis. Considering the high heterogeneity of the studies included, a meta-analysis could not be performed.
RESULTS
The majority of the included studies had a moderate or high risk of bias. When compared to traditional hybrid composites, fiber-reinforced composites showed increased fracture resistance of endodontically treated teeth in the majority of investigations. On the other hand, limited evidence was found for the bulk fill composites. Moreover, moderate evidence was found for the fracture resistance of inlays and fiber posts with fiber-reinforced composites for core build-up in endodontically treated teeth. No evidence could be found comparing the fracture resistance of endo crowns and fiber-reinforced composites in endodontically treated teeth.
CONCLUSION
According to the research, using fiber-reinforced composites instead of conventional hybrid composites improves the fracture resistance of endodontically treated teeth. However, there was a high risk of bias in the research considered. No judgments could be reached about the superiority of one material over another based-on comparisons between other core restorations.
Topics: Humans; Tooth, Nonvital; Dental Materials; Crowns; Tooth Fractures; Composite Resins; Dental Stress Analysis
PubMed: 37574536
DOI: 10.1186/s12903-023-03217-2 -
Operative Dentistry Nov 2021The following PICO (Patient/Population, Intervention, Comparison, and Outcomes) question was proposed: "Are retention rates of composite resin restorations in noncarious... (Meta-Analysis)
Meta-Analysis
PURPOSE
The following PICO (Patient/Population, Intervention, Comparison, and Outcomes) question was proposed: "Are retention rates of composite resin restorations in noncarious cervical lesions (NCCLs) when using adhesives considered "gold standard" (OptiBond FL and Clearfil SE Bond) higher than those obtained with other adhesives brands"?
METHODS
A search was performed in February 2019 (updated in November 2019) in the PubMed/MEDLINE, EMBASE, LILACS, BBO, Web of Science, Cochrane Library, Grey Literature, and IADR abstracts (1990-2018); unpublished and ongoing trial registries, dissertations, and theses were also searched. Only randomized clinical trials (RCTs) conducted in NCCLs that compared either OptiBond FL or Clearfil SE Bond adhesive with other commercially available adhesives were included. The risk of bias (RoB) was applied by using the Cochrane Collaboration tool. A meta-analysis was performed for retention rates at different follow-up times using a random effects model for both the adhesives. Heterogeneity was assessed with the Cochran Q test and I2 statistics. Grading of Recommendations: Assessment, Development and Evaluation (GRADE) assessed the quality of evidence.
RESULTS
After removal of duplicates and noneligible articles, 25 studies remained for qualitative synthesis, as one study was common to the two adhesives, of which 9 studies were used for the OptiBond FL meta-analysis and 14 for the Clearfil SE Bond meta-analysis. No significant differences were observed for retention rates in follow-up periods of 12-24 months (p=0.97), 36-48 months (p=0.72), or 108-156 months (p=0.73) for OptiBond FL; and for 12-24 months (p=0.10) and 36-48 months (p=0.17) for Clearfil SE Bond. A significant difference was only found for OptiBond FL at 60-96 months (p=0.02), but only three studies were included in this meta-analysis.
CONCLUSIONS
The evidence from available RCTs conducted in NCCLs that compared OptiBond FL or Clearfil SE Bond does not support the widespread concept that these adhesives are better than any other competitive brands available in the dental market.
Topics: Composite Resins; Dental Bonding; Dental Cements; Dental Restoration, Permanent; Dentin-Bonding Agents; Humans; Resin Cements
PubMed: 34919728
DOI: 10.2341/20-059-LIT -
The Journal of Prosthetic Dentistry Jul 2023Screwmentable prostheses were developed to combine the benefits of screw retention and cement retention. However, data are limited on the clinical performance of this... (Review)
Review
STATEMENT OF PROBLEM
Screwmentable prostheses were developed to combine the benefits of screw retention and cement retention. However, data are limited on the clinical performance of this type of prosthesis.
PURPOSE
The purpose of this systematic review was to collect scientific evidence on screwmentable prostheses and evaluate their long-term clinical behavior.
MATERIAL AND METHODS
An electronic search was conducted by 2 independent reviewers for articles published in scientific dental journals in English from 2004 to April 2020. The search strategy followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Inclusion criteria were scientific studies concerning the screwmentable type of prosthesis.
RESULTS
The search provided 494 records. Of these, 24 studies fulfilled the inclusion criteria and were included in the review. The included articles presented significant heterogeneity concerning the manufacturing process and the materials used. One randomized clinical trial, 2 prospective clinical studies, 14 in vitro studies, 3 protocol descriptions, 1 case series, and 3 case reports were included.
CONCLUSIONS
Based on the systematic search of the literature, it is concluded that the screwmentable prosthesis combines advantages of both cement-retained and screw-retained restorations, including passive fit, retrievability, excess cement control, tissue-friendly emergence profile, and improved esthetics. Nevertheless, data from well-designed clinical trials are limited, and further research is required to provide evidence on their long-term clinical behavior.
Topics: Dental Implants; Dental Prosthesis Retention; Prospective Studies; Dental Prosthesis, Implant-Supported; Esthetics, Dental; Dental Cements; Glass Ionomer Cements; Randomized Controlled Trials as Topic
PubMed: 34740460
DOI: 10.1016/j.prosdent.2021.08.027