Frontiers in Digital Health 2023This systematic review aims to assess the effectiveness of virtual reality (VR) and gamification interventions in addressing anxiety and depression. The review also... (Review)
Review
This systematic review aims to assess the effectiveness of virtual reality (VR) and gamification interventions in addressing anxiety and depression. The review also seeks to identify gaps in the current VR treatment landscape and provide guidelines for future research and development. A systematic literature search was conducted using Scopus, Web of Science, and PubMed databases, focusing on studies that utilized VR and gamification technology to address anxiety and depression disorders. A total of 2,664 studies were initially identified, 15 of those studies fulfilled the inclusion criteria for this systematic review. The efficacy of VR in addressing anxiety and depression was evident across all included studies. However, the diversity among VR interventions highlights the need for further investigation. It is advised to incorporate more diverse participant samples and larger cohorts and explore a broader spectrum of therapeutic approaches within VR interventions for addressing anxiety and depression to enhance the credibility of future research. Additionally, conducting studies in varying socioeconomic contexts would contribute to a more comprehensive understanding of their real-world applicability.
PubMed: 38026832
DOI: 10.3389/fdgth.2023.1239435 -
Journal of Neurology Mar 2023Several studies report mixed associations between the retinal nerve fiber layer (RNFL) thickness with cognitive and physical disability in persons with multiple... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Several studies report mixed associations between the retinal nerve fiber layer (RNFL) thickness with cognitive and physical disability in persons with multiple sclerosis (PwMS). Systematic synthesis of these findings is crucial in deriving credible conclusions.
METHODS
Five databases were searched from their inception to March 2022. The inclusion criteria for studies were MS-specific and required RNFL and cognitive performance data in order to be analyzed. The selection processes followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines.
RESULTS
The systematic review yielded 31 studies that investigated the association between RNFL thickness and cognitive performance. Twenty-two studies reported positive associations, and nine did not. The meta-analysis included 11 studies with a total of 782 PwMS with mean age of 40.5 years, mean Expanded Disability Status Scale (EDSS) of 2.7, and disease duration of 11.3 years. RNFL thickness was significantly associated Symbol Digit Modalities Test (pooled r = 0.306, p < 0.001), Paced Auditory Serial Addition Test (pooled r = 0.374, p < 0.001) and Word List Generation (WLG, pooled r = 0.177, p < 0.001). RNFL was also significantly correlated with visuospatial learning and memory tests (pooled r = 0.148, p = 0.042) and verbal learning and memory tests (pooled r = 0.245, p = 0.005). Within three eligible studies, no significant association between ganglion cell inner-plexiform layer and SDMT 0.083 (95% CI - 0.186, 0.352) was noted. The heterogeneity was high in all correlation studies (I > 63% and p < 0.008) except for the WLG and visuospatial memory findings.
CONCLUSION
RNFL thickness is associated with cognitive processing speed, verbal learning and memory, visual learning and memory, as well as verbal fluency in PwMS. The number of studies included in the meta-analyses were limited due to non-standardized reporting.
Topics: Humans; Adult; Multiple Sclerosis; Nerve Fibers; Tomography, Optical Coherence; Retina; Cognition
PubMed: 36396812
DOI: 10.1007/s00415-022-11449-5 -
Digital Health 2022The evidence of the impact of online health information-seeking (OHIS) on health outcomes has been conflicting. OHIS is increasingly recognised as a factor influencing... (Review)
Review
BACKGROUND
The evidence of the impact of online health information-seeking (OHIS) on health outcomes has been conflicting. OHIS is increasingly recognised as a factor influencing health behaviour but the impact of OHIS on medication adherence remains unclear.
OBJECTIVES
We conducted a systematic review and meta-analysis to examine the associations between OHIS and medication adherence.
METHODS
We searched Medline, Embase, Web of Science, Scopus, CINAHL and Psychology and Behavioural Science Collection for studies published up to December 2020. The inclusion criteria were studies that reported the associations of OHIS and medication adherence, quantitative design, reported primary data only, related to any health condition where medications are used and conducted on patients either in clinical or community settings. A meta-analysis was used to examine the association between OHIS and medication adherence.
RESULTS
A total of 17 studies involving 24,890 patients were included in this review. The study designs and results were mixed. In the meta-analysis, there was no significant association (n = 7, OR 1.356, 95% CI 0.793-2.322, p = 0.265), or correlation (n = 4, r = -0.085, 95% CI -0.572-0.446, p = 0.768) between OHIS and medication adherence. In the sub-group analysis of people living with HIV/AIDS, OHIS was associated with better medication adherence (OR 1.612, 95% CI 1.266-2.054, p < 0.001).
CONCLUSIONS
The current evidence of an association between OHIS and medication adherence is inconclusive. This review highlights methodological issues on how to measure OHIS objectively and calls for in-depth exploration of how OHIS affects health decisions and behaviour.
PubMed: 35586836
DOI: 10.1177/20552076221097784 -
NPJ Digital Medicine May 2023Given the limitations of traditional approaches, wearable artificial intelligence (AI) is one of the technologies that have been exploited to detect or predict...
Given the limitations of traditional approaches, wearable artificial intelligence (AI) is one of the technologies that have been exploited to detect or predict depression. The current review aimed at examining the performance of wearable AI in detecting and predicting depression. The search sources in this systematic review were 8 electronic databases. Study selection, data extraction, and risk of bias assessment were carried out by two reviewers independently. The extracted results were synthesized narratively and statistically. Of the 1314 citations retrieved from the databases, 54 studies were included in this review. The pooled mean of the highest accuracy, sensitivity, specificity, and root mean square error (RMSE) was 0.89, 0.87, 0.93, and 4.55, respectively. The pooled mean of lowest accuracy, sensitivity, specificity, and RMSE was 0.70, 0.61, 0.73, and 3.76, respectively. Subgroup analyses revealed that there is a statistically significant difference in the highest accuracy, lowest accuracy, highest sensitivity, highest specificity, and lowest specificity between algorithms, and there is a statistically significant difference in the lowest sensitivity and lowest specificity between wearable devices. Wearable AI is a promising tool for depression detection and prediction although it is in its infancy and not ready for use in clinical practice. Until further research improve its performance, wearable AI should be used in conjunction with other methods for diagnosing and predicting depression. Further studies are needed to examine the performance of wearable AI based on a combination of wearable device data and neuroimaging data and to distinguish patients with depression from those with other diseases.
PubMed: 37147384
DOI: 10.1038/s41746-023-00828-5 -
Journal of the Academy of... 2022Chronic cerebral hypoperfusion is a potential mechanism that causes cognitive impairment in patients with heart failure. Cognitive impairment in this population is... (Review)
Review
BACKGROUND
Chronic cerebral hypoperfusion is a potential mechanism that causes cognitive impairment in patients with heart failure. Cognitive impairment in this population is associated with an increased mortality and poorer quality of life. Understanding the etiopathogenesis of cognitive impairment is crucial to developing effective treatment. A left ventricular assist device (LVAD) is a durable mechanical circulatory support device that restores systemic perfusion in patients with heart failure, potentially reversing cerebral hypoperfusion and cognitive impairment.
OBJECTIVE
This case series and systematic review examines the effect of LVAD implantation on cognition in patients with heart failure.
METHODS
We report a case series of 4 LVAD recipients at a tertiary academic center who underwent preimplant and postimplant cognitive testing. We also conducted a systematic review of studies with adult recipients of a continuous-flow LVAD whose cognition was measured before and after implantation. We searched Medline, EMBASE, SCOPUS, and the Cochrane library (start of database to July 16, 2021) for longitudinal, peer-reviewed studies written in English.
RESULTS
Cognitive improvement after LVAD implantation was observed in the case series, with improvement on phonemic fluency and digit symbol coding assessments. Two out of 4 cases in the case series improved on Clinical Dementia Rating: one from moderate dementia to mild cognitive impairment and another from mild cognitive impairment to unimpaired. Seven studies were included in the systematic review and were heterogeneous regarding cognitive tests employed, follow-up period, and measured outcomes. Montreal Cognitive Assessment and Trail-Making Test Part B were used most commonly. Cognitive improvement was reported in all 7 studies with at least 1 study reporting statistically significant improvements in each the following cognitive domains: delayed and immediate recall, executive function, visuospatial function, verbal function, attention, and processing speed. Most studies had small sample sizes and lacked a control group.
CONCLUSIONS
LVAD implantation appears to be associated with improved cognition. Adequately powered, prospective studies are needed to examine the effect of LVAD on cognitive function in patients with heart failure. Additionally, studies that directly examine cerebral blood flow in conjunction with cognitive assessment are needed to establish the relationship between the reversal of cerebral hypoperfusion and improved cognition.
Topics: Adult; Humans; Heart-Assist Devices; Quality of Life; Heart Failure; Treatment Outcome; Cognition
PubMed: 36116764
DOI: 10.1016/j.jaclp.2022.09.003 -
Journal of Hand and Microsurgery Jun 2024Propeller perforator flaps (PPFs) have increased in popularity due to the freedom in design and ability to cover a variety of defects without sacrificing the major...
BACKGROUND
Propeller perforator flaps (PPFs) have increased in popularity due to the freedom in design and ability to cover a variety of defects without sacrificing the major vessels. Present reports of PPFs for upper limb reconstruction have not provided guidance for hand reconstruction, specifically. This study aims to review the current literature and evaluate techniques for use of PPFs in hand reconstruction.
METHODS
A comprehensive literature review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for articles published from 1991 to 2021. The database search was queried for records using appropriate Medical Subject Headings (MeSH) terms. Studies reporting PPFs were limited to English language and excluded lower extremity or upper extremity reconstruction not specific to defects in the hand or digits. Study characteristics, patient demographics, indications, preoperative testing, flap characteristics, flap survival, and complication rates were collected.
RESULTS
Out of the initial 1,348 citations yielded, 71 underwent full-text review. Ultimately, 25 unique citations were included encompassing 12 retrospective reviews (48%), 3 prospective cohort studies (10%), and 10 case series (40%). In review, 525 patients underwent reconstruction with a total of 613 propeller flaps performed to repair defects of the hand, digits, or both with use of 18 unique flap types. Overall flap survival was 97.8%. Acute wounds accounted for 72.9% of performed reconstructions. The mean flap coverage was 14.7 cm. Complications occurred in 19.8% of cases, with venous congestion and partial flap necrosis occurring in 5.5 and 6.5% of cases, respectively, leading to a flap failure rate of 2.1%.
CONCLUSION
PPFs are a reliable option for hand or digital reconstruction, allowing surgeons to cover a variety of defects without sacrificing local vasculature. Despite nearly a 20% reported complication rate, nearly all flaps with venous congestion and partial flap necrosis included in these articles resolved without the need for secondary intervention, retaining an excellent overall flap survival.
PubMed: 38855530
DOI: 10.1055/s-0043-1768482 -
Digital Health 2023Artificial intelligence (AI) has been increasingly applied in various fields of science and technology. In line with the current research, medicine involves an... (Review)
Review
OBJECTIVE
Artificial intelligence (AI) has been increasingly applied in various fields of science and technology. In line with the current research, medicine involves an increasing number of artificial intelligence technologies. The introduction of rapid AI can lead to positive and negative effects. This is a multilateral analytical literature review aimed at identifying the main branches and trends in the use of using artificial intelligence in medical technologies.
METHODS
The total number of literature sources reviewed is n = 89, and they are analyzed based on the literature reporting evidence-based guideline PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) for a systematic review.
RESULTS
As a result, from the initially selected 198 references, 155 references were obtained from the databases and the remaining 43 sources were found on open internet as direct links to publications. Finally, 89 literature sources were evaluated after exclusion of unsuitable references based on the duplicated and generalized information without focusing on the users.
CONCLUSIONS
This article is identifying the current state of artificial intelligence in medicine and prospects for future use. The findings of this review will be useful for healthcare and AI professionals for improving the circulation and use of medical AI from design to implementation stage.
PubMed: 37485326
DOI: 10.1177/20552076231189331 -
Digital Health 2023Artificial intelligence (AI) technologies are transforming medicine and healthcare. Scholars and practitioners have debated the philosophical, ethical, legal, and... (Review)
Review
BACKGROUND
Artificial intelligence (AI) technologies are transforming medicine and healthcare. Scholars and practitioners have debated the philosophical, ethical, legal, and regulatory implications of medical AI, and empirical research on stakeholders' knowledge, attitude, and practices has started to emerge. This study is a systematic review of published empirical studies of medical AI ethics with the goal of mapping the main approaches, findings, and limitations of scholarship to inform future practice considerations.
METHODS
We searched seven databases for published peer-reviewed empirical studies on medical AI ethics and evaluated them in terms of types of technologies studied, geographic locations, stakeholders involved, research methods used, ethical principles studied, and major findings.
FINDINGS
Thirty-six studies were included (published 2013-2022). They typically belonged to one of the three topics: exploratory studies of stakeholder knowledge and attitude toward medical AI, theory-building studies testing hypotheses regarding factors contributing to stakeholders' acceptance of medical AI, and studies identifying and correcting bias in medical AI.
INTERPRETATION
There is a disconnect between high-level ethical principles and guidelines developed by ethicists and empirical research on the topic and a need to embed ethicists in tandem with AI developers, clinicians, patients, and scholars of innovation and technology adoption in studying medical AI ethics.
PubMed: 37434728
DOI: 10.1177/20552076231186064 -
Digital Health 2020To date the application of eHealth strategies among adults and adolescents undergoing metabolic and bariatric surgery (MBS) has not been systematically reviewed. This... (Review)
Review
OBJECTIVE
To date the application of eHealth strategies among adults and adolescents undergoing metabolic and bariatric surgery (MBS) has not been systematically reviewed. This study comprehensively examines eHealth intervention studies among MBS patients within the RE-AIM framework to assess reach, effectiveness, adoption, implementation and maintenance of these efforts.
METHODS
A search was conducted using PubMed, EMBASE, CINAHL, PsycNET and SCOPUS of original research relating to eHealth strategies for MBS patients published in peer-reviewed journals and revealed 38 published articles between 2011 and 2019.
RESULTS
Studies varied widely in terms of design (qualitative to randomized controlled trials) and eHealth delivery method (telemedicine to blog post content) with a balance of pre- or post-MBS use. No studies included adolescents and very few reported (1) a conceptual framework to support study design/outcomes; and (2) race/ethnicity composition.
CONCLUSIONS
Although some studies report that eHealth strategies/interventions are effective in producing post-MBS weight loss and other positive health outcomes, most are pilot studies or have study design limitations. There is an opportunity for development of (1) tailored eHealth interventions to support pre- and post-MBS sustained behavior change and improved outcomes; and (2) rigorous studies that employ robust conceptual frameworks so dissemination and implementation efforts can be mapped to construct-driven outcomes.
PubMed: 32030193
DOI: 10.1177/2055207619898987 -
European Heart Journal. Digital Health Jun 2022High blood pressure (BP) is the commonest modifiable cardiovascular risk factor, yet its monitoring remains problematic. Wearable cuffless BP devices offer potential... (Review)
Review
AIMS
High blood pressure (BP) is the commonest modifiable cardiovascular risk factor, yet its monitoring remains problematic. Wearable cuffless BP devices offer potential solutions; however, little is known about their validity and utility. We aimed to systematically review the validity, features and clinical use of wearable cuffless BP devices.
METHODS AND RESULTS
We searched MEDLINE, Embase, IEEE Xplore and the Cochrane Database till December 2019 for studies that reported validating cuffless BP devices. We extracted information about study characteristics, device features, validation processes, and clinical applications. Devices were classified according to their functions and features. We defined devices with a mean systolic BP (SBP) and diastolic BP (DBP) biases of <5 mmHg as valid as a consensus. Our definition of validity did not include assessment of device measurement precision, which is assessed by standard deviation of the mean difference-a critical component of ISO protocol validation criteria. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies version 2 tool. A random-effects model meta-analysis was performed to summarise the mean biases for SBP and DBP across studies. Of the 430 studies identified, 16 studies (15 devices, 974 participants) were selected. The majority of devices (81.3%) used photoplethysmography to estimate BP against a reference device; other technologies included tonometry, auscultation and electrocardiogram. In addition to BP and heart rate, some devices also measured night-time BP ( = 5), sleep monitoring ( = 3), oxygen saturation ( = 3), temperature ( = 2) and electrocardiogram ( = 3). Eight devices showed mean biases of <5 mmHg for SBP and DBP compared with a reference device and three devices were commercially available. The meta-analysis showed no statistically significant differences between the wearable and reference devices for SBP (pooled mean difference = 3.42 mmHg, 95% CI: -2.17, 9.01, I 95.4%) and DBP (pooled mean = 1.16 mmHg, 95% CI: -1.26, 3.58, I 87.1%).
CONCLUSION
Several cuffless BP devices are currently available using different technologies, offering the potential for continuous BP monitoring. The variation in standards and validation protocols limited the comparability of findings across studies and the identification of the most accurate device. Challenges such as validation using standard protocols and in real-life settings must be overcome before they can be recommended for uptake into clinical practice.
PubMed: 36713001
DOI: 10.1093/ehjdh/ztac021