Acta Cardiologica Sep 2023Transcatheter aortic valve implantation (TAVI) has been established as a reasonable alternative to surgical aortic valve replacement (SAVR) in patients with severe... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Transcatheter aortic valve implantation (TAVI) has been established as a reasonable alternative to surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis. However, long-term outcomes including valve durability and the need for reintervention are unanswered, especially in younger patients who tend to be low surgical risk. We performed a meta-analysis comparing clinical outcomes after TAVI and SAVR over 5 years stratified to low, intermediate, and high surgical risks.
METHODS
We identified propensity score-matched observational studies and randomised controlled trials comparing TAVI and SAVR. Primary outcomes, including all-cause mortality, moderate or severe aortic regurgitation, moderate or severe paravalvular regurgitation, pacemaker placement, and stroke, were extracted. Meta-analyses of outcomes after TAVI compared to SAVR were conducted for different periods of follow-up. Meta-regression was also performed to analyse the correlation of outcomes over time.
RESULTS
A total of 36 studies consisting of 7 RCTs and 29 propensity score-matched studies were selected. TAVI was associated with higher all-cause mortality at 4-5 years in patients with low or intermediate surgical risk. Meta-regression time demonstrated an increasing trend in the risk of all-cause mortality after TAVI compared with SAVR. TAVI was generally associated with a higher risk of moderate or severe aortic regurgitation, moderate or severe paravalvular regurgitation, and pacemaker placement.
CONCLUSIONS
TAVI demonstrated an increasing trend of all-cause mortality compared with SAVR when evaluated over a long-term follow-up. More long-term data from recent studies using newer-generation valves and state-of-the-art techniques are needed to accurately assign risks.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Heart Valve Prosthesis Implantation; Aortic Valve Insufficiency; Aortic Valve Stenosis; Risk Factors; Treatment Outcome
PubMed: 37294002
DOI: 10.1080/00015385.2023.2218025 -
Archives of Cardiovascular Diseases Dec 2023Leaflet thrombosis and reduced leaflet motion have become a concern with the expanding use of transcatheter aortic valve replacement in lower-risk patients. (Meta-Analysis)
Meta-Analysis
BACKGROUND
Leaflet thrombosis and reduced leaflet motion have become a concern with the expanding use of transcatheter aortic valve replacement in lower-risk patients.
AIMS
To assess the proportions, predictors and clinical impact of leaflet thrombosis and reduced leaflet motion after transcatheter aortic valve replacement.
METHODS
We performed a meta-analysis of studies assessing the proportions of and/or clinical outcomes according to the presence of leaflet thrombosis after transcatheter aortic valve replacement identified with computed tomography and/or echocardiography.
RESULTS
Fifty-three studies, representing 25,258 patients undergoing transcatheter aortic valve replacement, were considered. The proportion of leaflet thrombosis was 5.2% overall, and was higher in computed tomography versus echocardiography (16.4% vs. 1.1%, respectively); reduced leaflet motion was identified in 11% of patients with four-dimensional computed tomography. Intra-annular bioprostheses were associated with a higher proportion of leaflet thrombosis, whereas chronic oral anticoagulation was protective for leaflet thrombosis in both computed tomography and echocardiographic studies (9.7% vs. 17.5%; relative risk [RR]: 0.51, 95% confidence interval [95% CI]: 0.37-0.71 and 0.9% vs. 2.7%; RR: 0.22, 95% CI: 0.06-0.79, respectively) and for reduced leaflet motion (2.5% vs. 12.4%; RR: 0.32, 95% CI: 0.13-0.76). Leaflet thrombosis was not associated with an increased risk of death, but with a higher risk of stroke in computed tomography studies (2.8% vs. 2.4%; RR: 1.63, 95% CI: 1.05-2.55), a difference more pronounced when considering reduced leaflet motion (3.5% vs. 1.7%; RR: 2.39, 95% CI: 0.63-8.34).
CONCLUSIONS
The proportion of leaflet thrombosis is highly variable according to the screening approach, the type of valve and the use of oral anticoagulation. The occurrence of cerebral events is increased when leaflet thrombosis and/or reduced leaflet motion are diagnosed, but leaflet thrombosis has no impact on survival.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Heart Valve Prosthesis; Thrombosis; Anticoagulants; Aortic Valve Stenosis; Treatment Outcome
PubMed: 37968182
DOI: 10.1016/j.acvd.2023.10.003 -
Journal of Cardiac Surgery Dec 2022To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. (Review)
Review
OBJECTIVES
To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement.
METHODS
We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature.
RESULTS
Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%-6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%-3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%-0.7% and Perceval 0%-1%), endocarditis (Intuity 0.2%-0.7% and Perceval 1.6%-6.6%), stroke (Intuity 0.36%-1.4% and Perceval 0%-0.8%), MI (Intuity 0.07%-0.26%), and SVD (Intuity 0.12%-0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%-2.1% for SFS. Hospital costs outcomes ranged from $37,187-$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%.
CONCLUSIONS
This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.
Topics: Humans; Aortic Valve; Aortic Valve Stenosis; Bioprosthesis; Heart Valve Prosthesis; Prosthesis Design; Retrospective Studies; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 36403259
DOI: 10.1111/jocs.17231 -
Cardiovascular Revascularization... Sep 2022
Meta-Analysis
Commentary on the Prognostic Impact of Pre- and Post-Procedural Renal Dysfunction on Late All-Cause Mortality Outcome Following Transcatheter Edge-to-Edge Repair of the Mitral Valve: A Systematic Review and Meta-Analysis.
Topics: Heart Valve Prosthesis Implantation; Humans; Kidney Diseases; Mitral Valve; Mitral Valve Insufficiency; Prognosis
PubMed: 35811241
DOI: 10.1016/j.carrev.2022.04.022 -
International Journal of Infectious... Apr 2022We aimed to describe the clinical, microbiological, and imaging characteristics of patients with infective endocarditis (IE) in studies from Latin America (LATAM). (Review)
Review
OBJECTIVES
We aimed to describe the clinical, microbiological, and imaging characteristics of patients with infective endocarditis (IE) in studies from Latin America (LATAM).
METHODS
A systematic search through PubMed, EMBASE, LILACS, and SciELO from inception until February 2021 was conducted. We included observational studies that assessed adults with IE from LATAM and reported data on clinical, microbiological, or imaging characteristics. Data were independently extracted by 2 authors and the risk of bias was evaluated by study design with its respective tool. Findings were summarized using descriptive statistics.
RESULTS
Forty-four studies were included. Most cases were male (68.5%), had a predisposing condition including valve disease (24.3%), or had a prosthetic valve (23.4%). Clinical manifestations included fever (83.9%), malaise (63.2%), or heart murmur (57.7%). A total of 36.4% and 27.1% developed heart failure or embolism, respectively. Blood cultures were negative in 23.9% and S. aureus (18.6%) and the viridans group streptococci (17.8%) were the most common isolates. Most cases were native valve IE (67.3%) affecting mainly left-sided valves. Echocardiographic findings included vegetations (84.3%) and regurgitation (75.9%). In-hospital mortality was 25.1%.
CONCLUSIONS
This is the first systematic review that evaluated the characteristics of IE in LATAM patients. A lack of multicenter studies reflects the need for these studies in LATAM.
Topics: Adult; Echocardiography; Endocarditis; Endocarditis, Bacterial; Humans; Latin America; Male; Retrospective Studies; Staphylococcus aureus
PubMed: 35181535
DOI: 10.1016/j.ijid.2022.02.022 -
The Journal of Invasive Cardiology Nov 2023Transcatheter edge-to-edge repair (TEER) using the MitraClip (Abbott Vascular) system has emerged as a standard treatment for patients with symptomatic severe secondary... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Transcatheter edge-to-edge repair (TEER) using the MitraClip (Abbott Vascular) system has emerged as a standard treatment for patients with symptomatic severe secondary or inoperable primary mitral regurgitation (MR). The relatively recent approval of the PASCAL Transcatheter Valve Repair System (Edwards Lifesciences) has expanded the options of TEER devices. However, evidence comparing PASCAL with MitraClip systems is still limited.
METHODS
We conducted a systematic literature research and meta-analysis in PubMed, Medline, and EMBASE databases for studies comparing PASCAL and MitraClip systems.
RESULTS
Four observational studies and 1 randomized controlled trial, involving 1315 patients total, were eligible for inclusion. All patients exhibited symptomatic (NYHA II-IV) MR grades 3+ or 4+. Baseline characteristics were comparable across all included studies. The clinical outcomes were assessed according to the Mitral Valve Academic Research Consortium consensus. The procedural success rates for the 2 devices were comparable in terms of achieving post-procedural MR grades of less than or equal to 2+ and less than or equal to 1+. Furthermore, most patients improved their clinical status, with no significant differences between patients treated with PASCAL and those treated with MitraClip. In terms of safety, both procedures exhibited low overall mortality rates and occurrence of major adverse events (MAE), without significant difference between the 2 devices. These findings remained consistent in both short- and long-term follow-up assessments.
CONCLUSIONS
Our study revealed similar effectiveness and safety profiles between the PASCAL and MitraClip devices in patients experiencing significant symptomatic MR.
Topics: Humans; Cardiac Catheterization; Cardiac Surgical Procedures; Catheters; Heart Valve Prosthesis Implantation; Mitral Valve; Mitral Valve Insufficiency; Treatment Outcome
PubMed: 37992330
DOI: 10.25270/jic/23.00218 -
Journal of Cardiac Surgery Sep 2022Valvular heart disease (VHD) is a prominent problem in healthcare today with mitral regurgitation (MR) being the leading cause of VHD in the elderly population. While... (Review)
Review
BACKGROUND
Valvular heart disease (VHD) is a prominent problem in healthcare today with mitral regurgitation (MR) being the leading cause of VHD in the elderly population. While mitral valve repair (MVr) surgery is one of the only options for the end-stage disease, octogenarians are often denied MVr due to concerns with operative mortality and postoperative morbidity. To provide information on this underrepresented group of surgical patients, a systematic approach was taken to review the mortality and morbidity rates of octogenarians who received MVr.
METHODS
Pubmed and Medline were searched for articles containing outcomes of octogenarians receiving surgical mitral valve repair (SMVr) or transcatheter mitral valve repair (TMVr) published after 2000. Ten articles met the inclusion criteria for a total of 7968 patients included in the analysis using Microsoft Excel, Version 2105.
RESULTS
Short-term mortality rates for SMVr and TMVr were 2.6% and 1.4% for in-hospital, and 7.8% and 3.3% for 30 days, respectively. The average incidence of stroke, acute kidney injury, infection, and major bleeding for SMVr were 3.2%, 11.2%, 7.7%, and 24%, respectively, and 0.3%, 6.7%, 2.7%, and 7.9% for TMVr, respectively.
CONCLUSION
Octogenarians receiving SMVr or TMVr experienced similar rates of short-term mortality and morbidity as younger populations, and when considering life expectancy, midterm mortality was also similar. With these results, denying octogenarians MVr operations based on age alone should be reconsidered. Depending on risk factors and comorbidities, either SMVr or TMVr is a viable and relatively safe option for octogenarians with severe MR.
Topics: Aged; Aged, 80 and over; Cardiac Catheterization; Heart Valve Diseases; Heart Valve Prosthesis Implantation; Humans; Mitral Valve; Mitral Valve Insufficiency; Morbidity; Octogenarians; Treatment Outcome
PubMed: 35652892
DOI: 10.1111/jocs.16653 -
Open Heart Aug 2023Assessment of frailty prior to aortic valve intervention is recommended in European and North American valvular heart disease guidelines. However, there is a lack of... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
Assessment of frailty prior to aortic valve intervention is recommended in European and North American valvular heart disease guidelines. However, there is a lack of consensus on how it is best measured. The Clinical Frailty Scale (CFS) is a well-validated measure of frailty that is relatively quick to calculate. This meta-analysis sought to examine whether the CFS predicts mortality and morbidity following either transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR).
METHODS
Nine electronic databases were searched systematically for data on clinical outcomes post-TAVI/SAVR, where patients had undergone preoperative frailty assessment using the CFS. The primary endpoint was 12-month mortality. TAVI and SAVR data were assessed and reported separately. For each individual study, the incidence of adverse outcomes was extracted according to a CFS score of 5-9 (ie, frail) versus 1-4 (ie, non-frail), with meta-analysis performed using a random effects model.
RESULTS
Of 2612 records screened, nine were included in the review (five TAVI, three SAVR and one which included both interventions). Among 4923 TAVI patients, meta-analysis showed 12-month mortality rates of 19.1% for the frail cohort versus 9.8% for the non-frail cohort (RR 2.53 (1.63 to 3.95), p<0.001, I=83%). For the smaller cohort of SAVR patients (n=454), mortality rates were 20.3% versus 3.9% for the frail and non-frail cohorts, respectively (RR 5.08 (2.31 to 11.15), p<0.001, I=5%).
CONCLUSIONS
Frailty, as determined by the CFS, was associated with an increased mortality risk in the 12 months following either TAVI or SAVR. These data would support its use in the preoperative assessment of elderly patients undergoing aortic valve interventions.
Topics: Humans; Aged; Aortic Valve; Aortic Valve Stenosis; Frailty; Risk Factors; Transcatheter Aortic Valve Replacement
PubMed: 37567604
DOI: 10.1136/openhrt-2023-002354 -
Clinical Research in Cardiology :... Aug 2022Periinterventional stroke is one of the most feared potential complication, among patients treated with transcatheter aortic valve implantation (TAVI). The purpose of... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
Periinterventional stroke is one of the most feared potential complication, among patients treated with transcatheter aortic valve implantation (TAVI). The purpose of this review was to investigate the incidence of cerebrovascular events and the influence of postinterventional neurologic check-up in patients undergoing TAVI.
METHODS
A systematic review and meta-analysis were conducted according to the PRISMA guideline. Three separate electronic searches of the public domains Medline and Clinicaltrials.gov were performed to identify the 30-day incidence of stroke within randomized controlled trials (RCTs) and registries for patients undergoing a TAVI procedure. A meta-analysis was conducted to evaluate the 30-day incidence of stroke within RCTs. Furthermore, we pooled the RCTs in which a scheduled neurological check-up was conducted or not to investigate the effect of this intervention.
RESULTS
Twenty-three studies including 399,491 TAVI patients were included, 6370 from RCTs, 833 from cerebral-embolic protection device RCTs and 392,288 were adopted from registries. The mean 30-day incidence of stroke among all reviewed studies was 2.33%. In RCTs evaluating TAVI the pooled stroke incidence was 3.86%, among RCTs focused CEP the incidence was 6.36% and in registries the incidence was 2.29%. Ten RCTs conducted scheduled neurological check-ups, the incidence in these was 4.03% and among the remaining RCTs it was 2.47%. In the meta-analysis, the pooled 30-day stroke incidence was 3.61% (95% CI 2.57-4.79%).
CONCLUSION
This systematic review demonstrates that the stroke incidences following TAVI differ strongly according to the study design and neurological follow-up. Intense neurological testing increases the incidence of a stroke after TAVI.
Topics: Aortic Valve; Aortic Valve Stenosis; Heart Valve Prosthesis Implantation; Humans; Incidence; Registries; Risk Factors; Stroke; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 35298700
DOI: 10.1007/s00392-022-01997-1 -
Herz Apr 2021Since readmission rate is an important clinical index to determine the quality of inpatient care and hospital performance, the aim of this study was to explain the... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Since readmission rate is an important clinical index to determine the quality of inpatient care and hospital performance, the aim of this study was to explain the causes and predictors of readmission following transcatheter aortic valve implantation (TAVI) at short-term and mid-term follow-up.
METHODS AND RESULTS
A systematic review and meta-analysis of all published articles from Embase, Pubmed/MEDLINE, and Ovid was carried out. In all, 10 studies including 52,702 patients were identified. The pooled estimate for the overall event rate was 0.15, and cardiovascular causes were the main reason for 30-day readmission (0.42, 95% confidence interval [CI]: 0.39-0.45). In addition, the pooled incidence of 1‑year readmission was 0.31, and cardiovascular events were still the main cause (0.41, 95% CI: 0.33-0.48). Patients with major and life-threatening bleeding, new permanent pacemaker implantation, and clinical heart failure were associated with a high risk for early readmission after TAVI. Moreover, an advanced (≥3) New York Heart Association classification, acute kidney injury, paravalvular leak, mitral regurgitation (≥ moderate), and major bleeding predicted unfavorable outcome to 1‑year readmission. Female gender and transfemoral TAVI was associated with a lower risk for unplanned rehospitalization.
CONCLUSIONS
This meta-analysis found cardiovascular factors to be the main causes for both 30-day and 1‑year rehospitalization. Heart failure represented the most common cardiovascular event at both short-term and mid-term follow-up. Several baseline characteristics and procedure-related factors were deemed unfavorable predictors of readmission. Importantly, transfemoral access and female gender were associated with a lower risk of readmission.
Topics: Aortic Valve; Aortic Valve Stenosis; Female; Heart Valve Prosthesis; Humans; Mitral Valve Insufficiency; Patient Readmission; Postoperative Complications; Risk Factors; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 31807789
DOI: 10.1007/s00059-019-04870-6