Catheterization and Cardiovascular... Jul 2021Pseudoaneurysm (PSA) formation is a rare but well-known complication of coronary stenting. It develops after a procedural perforation disrupts the integrity of the...
Pseudoaneurysm (PSA) formation is a rare but well-known complication of coronary stenting. It develops after a procedural perforation disrupts the integrity of the vessel wall but is contained by a single wall layer, usually pericardium, extravascular thrombosis and later fibrosis. Medical literature of PSA consists primarily of case reports. A systematic review of pseudoaneurysm after coronary stenting was performed to summarize its presentation, diagnostic imaging modalities, natural history, and management approaches. Clinical presentations range from asymptomatic to hemodynamic collapse, size from small to "giant," and treatment approaches from surgical or percutaneous exclusion to "watchful waiting" and imaging surveillance. Based on current information, a management algorithm is provided recommending urgent to emergent exclusion for symptomatic PSA, elective exclusion for large and giant PSA, and "watchful waiting" and periodic imaging surveillance for small to moderate sized PSA.
Topics: Aneurysm, False; Coronary Angiography; Humans; Pericardium; Stents; Treatment Outcome
PubMed: 33016651
DOI: 10.1002/ccd.29312 -
Surgical and Radiologic Anatomy : SRA Jun 2023To present two cases of Internal Carotid Artery (ICA) agenesis and conduct a systematic review to assess for associations with other anomalies and intracranial aneurysms. (Review)
Review
PURPOSE
To present two cases of Internal Carotid Artery (ICA) agenesis and conduct a systematic review to assess for associations with other anomalies and intracranial aneurysms.
METHODOLOGY
We performed a retrospective review of published cases of patients with ICA agenesis with intercavernous anastomosis in MEDLINE database on August 2022 using search terms "internal carotid artery", "agenesis" and "transcavernous anastomosis". We also included two cases of ICA agenesis with type D collateral that we encountered.
RESULTS
Total of 46 studies that included 48 patients and two of our cases resulted in 50 patients. Only 70% of studies reported the location of a collateral vessel of which more than two-thirds were on the floor of sella. More than half of the vessels connected cavernous segments of ICA. A1 segment ipsilateral to the side of ICA agenesis was absent in most of the cases but was not true for all cases. Aneurysm was seen in more than one-quarter of the patients. It can also mimic microadenoma as in prior reported cases as well as in one of our cases.
CONCLUSION
ICA agenesis with type D collateral is a rare anomaly but clinically relevant due to the increased risk of an aneurysm or mimic microadenoma or false alarm for occlusion of ICA but knowledge of this rare variant can help in better management of these patients.
Topics: Humans; Carotid Artery, Internal; Cerebral Arteries; Cerebral Veins; Intracranial Aneurysm; Vascular Malformations; Anastomosis, Surgical
PubMed: 36899092
DOI: 10.1007/s00276-023-03117-8 -
Biomedicines Oct 2023Subarachnoid hemorrhage resulting from cerebral aneurysm rupture is a significant cause of morbidity and mortality. Early identification of aneurysms on Computed... (Review)
Review
Subarachnoid hemorrhage resulting from cerebral aneurysm rupture is a significant cause of morbidity and mortality. Early identification of aneurysms on Computed Tomography Angiography (CTA), a frequently used modality for this purpose, is crucial, and artificial intelligence (AI)-based algorithms can improve the detection rate and minimize the intra- and inter-rater variability. Thus, a systematic review and meta-analysis were conducted to assess the diagnostic accuracy of deep-learning-based AI algorithms in detecting cerebral aneurysms using CTA. PubMed (MEDLINE), Embase, and the Cochrane Library were searched from January 2015 to July 2023. Eligibility criteria involved studies using fully automated and semi-automatic deep-learning algorithms for detecting cerebral aneurysms on the CTA modality. Eligible studies were assessed using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines and the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. A diagnostic accuracy meta-analysis was conducted to estimate pooled lesion-level sensitivity, size-dependent lesion-level sensitivity, patient-level specificity, and the number of false positives per image. An enhanced FROC curve was utilized to facilitate comparisons between the studies. Fifteen eligible studies were assessed. The findings indicated that the methods exhibited high pooled sensitivity (0.87, 95% confidence interval: 0.835 to 0.91) in detecting intracranial aneurysms at the lesion level. Patient-level sensitivity was not reported due to the lack of a unified patient-level sensitivity definition. Only five studies involved a control group (healthy subjects), whereas two provided information on detection specificity. Moreover, the analysis of size-dependent sensitivity reported in eight studies revealed that the average sensitivity for small aneurysms (<3 mm) was rather low (0.56). The studies included in the analysis exhibited a high level of accuracy in detecting intracranial aneurysms larger than 3 mm in size. Nonetheless, there is a notable gap that necessitates increased attention and research focus on the detection of smaller aneurysms, the use of a common test dataset, and an evaluation of a consistent set of performance metrics.
PubMed: 38001922
DOI: 10.3390/biomedicines11112921 -
Pacing and Clinical Electrophysiology :... Jan 2024This meta-analysis evaluated long-term efficacy and safety of cryoballoon ablation (CB) of atrial fibrillation (AF). (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
This meta-analysis evaluated long-term efficacy and safety of cryoballoon ablation (CB) of atrial fibrillation (AF).
METHODS
PubMed, Cochrane Library, and Web of Science were searched until July 31, 2023, for published works investigating efficacy and safety of CB of AF in which mean/median follow-up time was not less than 36 months. Safety was assessed by adverse events. Efficacy was assessed by AF recurrence, defined as any atrial arrhythmias lasting more than 30 s.
RESULTS
A total of 19 clinical studies were included. After an average of 58.1 months of follow-up, the overall AF recurrence rate was about 37%. The predictors of recurrence were duration of AF (HR 1.00; 95% CI [1.00 ∼ 1.01]), early recurrence of atrial fibrillation (HR 3.96; 95%CI [1.12 ∼ 14.02]), left atrial diameter (HR 1.04; 95%CI [1.02 ∼ 1.06]), and persistent AF (HR1.47; 95% CI [1.19 ∼ 1.82]). In terms of safety, the incidence of transient phrenic paralysis (PNP) was the highest, about 3%; followed by vascular complications (about 2%); pseudoaneurysm, permanent PNP, and all-cause death was (about 1%); and pericardial effusion and stroke / TIA was very low.
CONCLUSION
CB is associated with low rates of severe complications and reasonable success rates.
Topics: Humans; Atrial Fibrillation; Cryosurgery; Treatment Outcome; Pulmonary Veins; Recurrence; Catheter Ablation
PubMed: 37988273
DOI: 10.1111/pace.14881 -
Neurosurgical Focus May 2023Pseudoaneurysms (PSAs) are complex vascular lesions. Flow diversion has been proposed as an alternative treatment to parent artery occlusion that preserves laminar flow.... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Pseudoaneurysms (PSAs) are complex vascular lesions. Flow diversion has been proposed as an alternative treatment to parent artery occlusion that preserves laminar flow. The authors of the present study investigated the safety and short-term (< 1 year) and long-term (≥ 1 year) aneurysm occlusion rates following the treatment of intracranial and extracranial PSAs using the Pipeline embolization device (PED).
METHODS
An electronic database search for full-text English-language articles in Ovid MEDLINE and Epub Ahead of Print, Ovid Embase, Ovid Cochrane Central Register of Controlled Trials, Ovid Cochrane Database of Systematic Reviews, and Scopus was conducted following the PRISMA guidelines. Studies of any design including at least 4 patients with intracranial or extracranial PSAs treated using a PED were included in this analysis. The primary outcome of interest was the rate of peri- and postprocedural complications. Secondarily, the authors analyzed the incidence of complete aneurysm occlusion.
RESULTS
A total of 90 patients with 96 PSAs across 9 studies were included. The mean age was 38.2 (SD 15.14) years, and 37.8% of the patients were women. The mean PSA size was 4.9 mm. Most PSAs were unruptured, and the most common etiology was trauma (n = 32, 35.5%), followed by spontaneous formation (n = 21, 23.3%) and iatrogenic injury (n = 19, 21.1%). Among the 51 (53.1%) intracranial and 45 (46.9%) extracranial PSAs were 19 (19.8%) dissecting PSAs. Sixty-six (77.6%) PSAs were in the internal carotid artery and 10 (11.8%) in the vertebral artery. Thirty-three (34.4%) PSAs were treated with ≥ 2 devices, and 8 (8.3%) underwent adjunctive coiling. The mean clinical and angiographic follow-up durations were 10.7 and 12.9 months, respectively. The short-term (< 1 year) and long-term (≥ 1 year) complete occlusion rates were 79% (95% CI 66%-88%, p = 0.82) and 84% (95% CI 70%-92%, p = 0.95), respectively. Complication rates were 8% for iatrogenic dissection (95% CI 3%-16%, p = 0.94), 10% for silent thromboembolism (95% CI 5%-21%, p = 0.77), and 12% for symptomatic thromboembolism (95% CI 6%-23%, p = 0.48). No treatment-related hemorrhage was observed. The overall mortality rate at the last follow-up was 14%.
CONCLUSIONS
The complete occlusion rate for PSAs treated with the PED was high and increased over time. Although postprocedural complications and mortality were not insignificant, flow diversion represents a reasonably safe option for managing these complex lesions.
Topics: Humans; Female; Adult; Male; Treatment Outcome; Aneurysm, False; Intracranial Aneurysm; Embolization, Therapeutic; Cerebral Angiography; Iatrogenic Disease; Retrospective Studies; Stents
PubMed: 37127035
DOI: 10.3171/2023.2.FOCUS22644 -
Journal of Cardiac Surgery Nov 2022The introduction of the frozen elephant trunk (FET) technique for total arch replacement (TAR) has revolutionized the field of aortovascular surgery. However, although... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The introduction of the frozen elephant trunk (FET) technique for total arch replacement (TAR) has revolutionized the field of aortovascular surgery. However, although FET yields excellent results, the risk of certain complications requiring secondary intervention remains present, negating its one-step hybrid advantage over conventional techniques. This systematic review and meta-analysis sought to evaluate controversies regarding the incidence of FET-related complications, with a focus on aortic remodeling, distal stent-graft induced new entry (dSINE) and endoleak, in patients with type A aortic dissection (TAAD) and/or thoracic aortic aneurysm.
MATERIALS AND METHODS
A comprehensive literature search was conducted using multiple electronic databases including EMBASE, Scopus, and PubMed/MEDLINE to identify evidence on TAR with FET in patients with TAAD and/or aneurysm. Studies published up until January 2022 were included, and after applying exclusion criteria, a total of 43 studies were extracted.
RESULTS
A total of 5068 patients who underwent FET procedure were included. The pooled estimates of dSINE and endoleak were 2% (95% confidence interval [CI] 0.01-0.06, I = 78%) and 3% (95% CI 0.01-0.11, I = 89%), respectively. The pooled rate of secondary thoracic endovascular aortic repair (TEVAR) post-FET was 7% (95% CI 0.05-0.12, I = 89%) while the pooled rate of false lumen thrombosis at the level of stent-graft was 91% (95% CI 0.75-0.97, I = 92%). After subgroup analysis, heterogeneity for distal stent-graft induced new entry (dSINE) and endoleak resolved among European patients, where Thoraflex Hybrid (THP) and E-Vita stent-grafts were used (both I = 0%). In addition, heterogeneity for secondary TEVAR after FET resolved among Asians receiving Cronus (I = 15.1%) and Frozenix stent-grafts (I = 1%).
CONCLUSION
Our results showed that the FET procedure in patients with TAAD and/or aneurysm is associated with excellent results, with a particularly low incidence of dSINE and endoleak as well as highly favorable aortic remodeling. However the type of stent-graft and the study location were sources of heterogeneity, emphasizing the need for multicenter studies directly comparing FET grafts. Finally, THP can be considered the primary FET device choice due to its superior results.
Topics: Aortic Dissection; Aorta, Thoracic; Aortic Aneurysm, Thoracic; Azides; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Deoxyglucose; Endoleak; Humans; Retrospective Studies; Stents; Treatment Outcome
PubMed: 36069163
DOI: 10.1111/jocs.16918 -
Journal of Endovascular Therapy : An... Jun 2023We present a case of successful endovascular repair of late ruptured aortic anastomotic pseudoaneurysm following previous left subclavian artery-descending thoracic... (Review)
Review
Solving Intraoperative Complications During Endovascular Repair of Late Contained Ruptured Aortic Pseudoaneurysm After Surgical De-coarctation: Case Report and Systematic Review of Literature.
AIM
We present a case of successful endovascular repair of late ruptured aortic anastomotic pseudoaneurysm following previous left subclavian artery-descending thoracic aorta bypass and concomitant emergency thoracic endovascular aortic repair (TEVAR) of complicated endovascular aortic de-coarctation never previously described is also presented. A review of the intraoperative, 30-day, and follow-up morbidity, mortality, and complications of TEVAR as endovascular treatment of late aneurysm/pseudoaneurysms after surgical aortic de-coarctation was also performed.
METHODS
The systematic review was performed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement and following PICO model. A literature search was conducted on MEDLINE, PubMed, EMBASE, Cochrane Library, Google Scholar, Science Direct, and Web of Science using the words "tevar of late complication of aortic coarctation surgical repair" and "endovascular repair of anastomotic pseudoaneurysm in coarctation" up to June 17, 2022. Data were extracted from study documents about study design, patient's demographics and comorbidities, details about primary surgical repair, type of late complication, time between open surgery and occurrence of complications, details of the secondary endovascular procedure with technical success, early, and follow-up mortality and morbidity.
RESULTS
A total of 18 papers were included with 78 patients (48 men, 69.5%). The most frequent type of primary open surgical repair was patch aortoplasty (46, 58.9%). Focusing on aneurysm and pseudoaneurysm as late complications, most of the patients were asymptomatic (45, 57.7%). All patients underwent TEVAR, 14 of them (17.9%) in urgent/emergent setting. The technical success was 98.7%, with 1 intraoperative death due to rupture of the aorta. In total, 31 patients out of 78 (39.7%) showed different complications in the immediate postoperative time, with type II endoleak being the most observed (8/31, 25.8%). The mean follow-up time was about 2 years (26.5 months, range 3-92). Overall, 30-day mortality was 2.6%. Complications occurred in 30 patients (39.4%), 23 of them resolved during the follow-up period.
CONCLUSIONS
With the limit of low-quality data, TEVAR can be considered a safe and effective option for the treatment of late complications after open surgery for aortic coarctation, even in urgent settings.
CLINICAL IMPACT
Different specialists have to face the technical complexities and risks related to treatment of late complications after surgical de-coartaction, which can be either surgical or endovascular, and depend on patient's ages. Although covered stents appear to have some protection from the development of stent fractures, doesn't provide complete protection from late aneurysm formation. In this setting, TEVAR may represent a valuable option, combining the advantages of the covered stent with those of a device that can cover a wider range of aortic length, especially in adult patients. This study shows thoracic endovascular repair can be considered a safe and effective option in clincal practice for the treatment of late complications after open surgery for AC, even in urgent settings.
PubMed: 37271989
DOI: 10.1177/15266028231177047 -
BJS Open Dec 2019Gastroduodenal artery (GDA) pseudoaneurysm is a serious complication following pancreatic resection, associated with high morbidity and mortality rates. This review...
BACKGROUND
Gastroduodenal artery (GDA) pseudoaneurysm is a serious complication following pancreatic resection, associated with high morbidity and mortality rates. This review aimed to report the incidence of GDA pseudoaneurysm after pancreatic surgery, and describe clinical presentation and management.
METHODS
MEDLINE and Embase were searched systematically for clinical studies evaluating postoperative GDA pseudoaneurysm. Incidence was calculated by dividing total number of GDA pseudoaneurysms by the total number of pancreatic operations. Additional qualitative data related to GDA pseudoaneurysm presentation and management following pancreatic resection were extracted and reviewed from individual reports.
RESULTS
Nine studies were selected for systematic review involving 4227 pancreatic operations with 55 GDA pseudoaneurysms, with a reported incidence of 1·3 (range 0·2-8·3) per cent. Additional data were extracted from 39 individual examples of GDA pseudoaneurysm from 14 studies. The median time for haemorrhage after surgery was at 15 (range 4-210) days. A preceding complication in the postoperative period was documented in four of 21 patients (67 per cent), and sentinel bleeding was observed in 14 of 20 patients (70 per cent). Postoperative complications after pseudoaneurysm management occurred in two-thirds of the patients (14 of 21). The overall survival rate was 85 per cent (33 of 39).
CONCLUSION
GDA pseudoaneurysm is a rare yet serious cause of haemorrhage after pancreatic surgery, with high mortality. The majority of the patients had a preceding complication. Sentinel bleeding was an important clinical indicator.
Topics: Aneurysm, False; Angiography; Embolization, Therapeutic; Endovascular Procedures; Hepatic Artery; Humans; Incidence; Pancreatectomy; Postoperative Hemorrhage; Survival Rate; Time Factors
PubMed: 31832579
DOI: 10.1002/bjs5.50210 -
Journal of Clinical Medicine Sep 2023Ruptured splenic artery aneurysms (r-SAA), although rare, are burdened by high morbidity and mortality, even despite emergent surgical repair. It is suggested that... (Review)
Review
BACKGROUND
Ruptured splenic artery aneurysms (r-SAA), although rare, are burdened by high morbidity and mortality, even despite emergent surgical repair. It is suggested that endovascular treatment can achieve reduction in peri-operative death and complication rates, as in other vascular diseases, but evidence of such benefits is still lacking in this particular setting. We report a case of an r-SAA treated by trans-arterial embolization and then converted to open surgery for persistent bleeding, and we provide a systematic review of current results of open and endovascular repair of r-SAAs.
MATERIALS AND METHODS
A 50-year-old male presenting in shock for a giant r-SAA underwent emergent coil embolization and recovered hemodynamic stability. On the following day, he underwent laparotomy for evacuation of the huge intraperitoneal hematoma, but residual bleeding was noted from the splenic artery, which was ligated after coil removal, and a splenectomy was performed. A systematic literature review of the reported mortality and complications of r-SAA undergoing open (OSR) or endovascular (EVT) treatment was performed using the main search databases. All primary examples of research published since 1990 were included regardless of sample size. The main outcome measures were mortality and reinterventions. Secondary outcomes were post-operative complications.
RESULTS
We selected 129 studies reporting on 350 patients-185 treated with OSR and 165 with EVT. Hemodynamically unstable patients and ruptures during pregnancy were more frequently treated with open repair. Overall, there were 37 deaths (mortality: 10.6%)-24 in the OSR group and 13 in the EVTr group (mortality: 12.9% and 7.8% respectively, -value: 0.84). There were 37 reinterventions after failed or complicated endovascular repair -6 treated with endovascular re-embolization and 31 with laparotomy and splenectomy (22.4%); there were 3 (1.6%) reinterventions after open repair. Overall complication rates were 7.3% in the EVT group (: 12) and 4.2% in the OSR group (: 7), and did not require reintervention. No significant differences in overall complications or in any specific complication rate were observed between the two groups.
CONCLUSIONS
Current results of r-SAA treatment show equipoise terms of morbidity and mortality between open and endovascular repair; however, in case of hemodynamic instability and rupture during pregnancy, open surgery might still be safer. Moreover, endovascular repair is still burdened by a significantly higher rate of reinterventions, mostly with conversions to open surgery.
PubMed: 37763025
DOI: 10.3390/jcm12186085 -
World Neurosurgery Aug 2023This study aims to systematically review the management and outcomes of pediatric patients who develop intracranial pseudoaneurysm (IPA) following head trauma or... (Review)
Review
OBJECTIVE
This study aims to systematically review the management and outcomes of pediatric patients who develop intracranial pseudoaneurysm (IPA) following head trauma or iatrogenic injury.
METHODS
Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a systematic literature review was performed. Additionally, a retrospective analysis was conducted on pediatric patients who underwent evaluation and endovascular treatment for IPA originating from head trauma or iatrogenic injury at a single institution.
RESULTS
Two hundred twenty-one articles in the original literature search. Fifty-one met inclusion criteria resulting in a total of 87 patients with 88 IPAs including our institution. Patients ranged in age from 0.5 months to 18 years. Parent vessel reconstruction was used as first-line treatment in 43 cases, parent vessel occlusion in 26, and direct aneurysm embolization (DAE) in 19. Intraoperative complications were observed in 3.00% of procedures. Complete aneurysm occlusion was achieved in 89.61% of cases. 85.54% of cases resulted in favorable clinical outcomes. The mortality rate after treatment was 3.61%. The DAE group had higher rates of aneurysm recurrence than other treatment strategies (P = 0.009). Patients with SAH had overall worse outcomes compared to patients who did not (P = 0.024). There were no differences in favorable clinical outcomes (P = 0.274) or complete aneurysm occlusion (P = 0.13) between primary treatment strategies.
CONCLUSIONS
IPAs were successfully obliterated, and favorable neurological outcomes were achieved at a high rate regardless of primary treatment strategy. DAE had a higher rate of recurrence than the other treatment groups. Each described treatment method in our review is safe and viable for the treatment of IPAs in pediatric patients.
Topics: Humans; Child; Retrospective Studies; Aneurysm, False; Treatment Outcome; Embolization, Therapeutic; Endovascular Procedures; Craniocerebral Trauma; Aneurysm; Iatrogenic Disease; Intracranial Aneurysm
PubMed: 37059359
DOI: 10.1016/j.wneu.2023.04.028