-
The Cochrane Database of Systematic... Jun 2021Miscarriage, defined as the spontaneous loss of a pregnancy before 24 weeks' gestation, is common with approximately 25% of women experiencing a miscarriage in their... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Miscarriage, defined as the spontaneous loss of a pregnancy before 24 weeks' gestation, is common with approximately 25% of women experiencing a miscarriage in their lifetime. An estimated 15% of pregnancies end in miscarriage. Miscarriage can lead to serious morbidity, including haemorrhage, infection, and even death, particularly in settings without adequate healthcare provision. Early miscarriages occur during the first 14 weeks of pregnancy, and can be managed expectantly, medically or surgically. However, there is uncertainty about the relative effectiveness and risks of each option.
OBJECTIVES
To estimate the relative effectiveness and safety profiles for the different management methods for early miscarriage, and to provide rankings of the available methods according to their effectiveness, safety, and side-effect profile using a network meta-analysis.
SEARCH METHODS
We searched the Cochrane Pregnancy and Childbirth's Trials Register (9 February 2021), ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform (ICTRP) (12 February 2021), and reference lists of retrieved studies.
SELECTION CRITERIA
We included all randomised controlled trials assessing the effectiveness or safety of methods for miscarriage management. Early miscarriage was defined as less than or equal to 14 weeks of gestation, and included missed and incomplete miscarriage. Management of late miscarriages after 14 weeks of gestation (often referred to as intrauterine fetal deaths) was not eligible for inclusion in the review. Cluster- and quasi-randomised trials were eligible for inclusion. Randomised trials published only as abstracts were eligible if sufficient information could be retrieved. We excluded non-randomised trials.
DATA COLLECTION AND ANALYSIS
At least three review authors independently assessed the trials for inclusion and risk of bias, extracted data and checked them for accuracy. We estimated the relative effects and rankings for the primary outcomes of complete miscarriage and composite outcome of death or serious complications. The certainty of evidence was assessed using GRADE. Relative effects for the primary outcomes are reported subgrouped by the type of miscarriage (incomplete and missed miscarriage). We also performed pairwise meta-analyses and network meta-analysis to determine the relative effects and rankings of all available methods.
MAIN RESULTS
Our network meta-analysis included 78 randomised trials involving 17,795 women from 37 countries. Most trials (71/78) were conducted in hospital settings and included women with missed or incomplete miscarriage. Across 158 trial arms, the following methods were used: 51 trial arms (33%) used misoprostol; 50 (32%) used suction aspiration; 26 (16%) used expectant management or placebo; 17 (11%) used dilatation and curettage; 11 (6%) used mifepristone plus misoprostol; and three (2%) used suction aspiration plus cervical preparation. Of these 78 studies, 71 (90%) contributed data in a usable form for meta-analysis. Complete miscarriage Based on the relative effects from the network meta-analysis of 59 trials (12,591 women), we found that five methods may be more effective than expectant management or placebo for achieving a complete miscarriage: · suction aspiration after cervical preparation (risk ratio (RR) 2.12, 95% confidence interval (CI) 1.41 to 3.20, low-certainty evidence), · dilatation and curettage (RR 1.49, 95% CI 1.26 to 1.75, low-certainty evidence), · suction aspiration (RR 1.44, 95% CI 1.29 to 1.62, low-certainty evidence), · mifepristone plus misoprostol (RR 1.42, 95% CI 1.22 to 1.66, moderate-certainty evidence), · misoprostol (RR 1.30, 95% CI 1.16 to 1.46, low-certainty evidence). The highest ranked surgical method was suction aspiration after cervical preparation. The highest ranked non-surgical treatment was mifepristone plus misoprostol. All surgical methods were ranked higher than medical methods, which in turn ranked above expectant management or placebo. Composite outcome of death and serious complications Based on the relative effects from the network meta-analysis of 35 trials (8161 women), we found that four methods with available data were compatible with a wide range of treatment effects compared with expectant management or placebo: · dilatation and curettage (RR 0.43, 95% CI 0.17 to 1.06, low-certainty evidence), · suction aspiration (RR 0.55, 95% CI 0.23 to 1.32, low-certainty evidence), · misoprostol (RR 0.50, 95% CI 0.22 to 1.15, low-certainty evidence), · mifepristone plus misoprostol (RR 0.76, 95% CI 0.31 to 1.84, low-certainty evidence). Importantly, no deaths were reported in these studies, thus this composite outcome was entirely composed of serious complications, including blood transfusions, uterine perforations, hysterectomies, and intensive care unit admissions. Expectant management and placebo ranked the lowest when compared with alternative treatment interventions. Subgroup analyses by type of miscarriage (missed or incomplete) agreed with the overall analysis in that surgical methods were the most effective treatment, followed by medical methods and then expectant management or placebo, but there are possible subgroup differences in the effectiveness of the available methods. AUTHORS' CONCLUSIONS: Based on relative effects from the network meta-analysis, all surgical and medical methods for managing a miscarriage may be more effective than expectant management or placebo. Surgical methods were ranked highest for managing a miscarriage, followed by medical methods, which in turn ranked above expectant management or placebo. Expectant management or placebo had the highest chance of serious complications, including the need for unplanned or emergency surgery. A subgroup analysis showed that surgical and medical methods may be more beneficial in women with missed miscarriage compared to women with incomplete miscarriage. Since type of miscarriage (missed and incomplete) appears to be a source of inconsistency and heterogeneity within these data, we acknowledge that the main network meta-analysis may be unreliable. However, we plan to explore this further in future updates and consider the primary analysis as separate networks for missed and incomplete miscarriage.
Topics: Abortion, Incomplete; Abortion, Missed; Abortion, Spontaneous; Drug Therapy, Combination; Female; Humans; Mifepristone; Misoprostol; Network Meta-Analysis; Oxytocics; Placebos; Pregnancy; Pregnancy Trimester, First; Randomized Controlled Trials as Topic; Suction; Vacuum Curettage; Watchful Waiting
PubMed: 34061352
DOI: 10.1002/14651858.CD012602.pub2 -
PloS One 2023Medical device-related pressure injury (MDRPI) in intensive care unit (ICU) patients is a serious issue. We aimed to evaluate the risk factors for MDRPI associated with... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Medical device-related pressure injury (MDRPI) in intensive care unit (ICU) patients is a serious issue. We aimed to evaluate the risk factors for MDRPI associated with ICU patients through systematic review and meta-analysis, and provide insights into the clinical prevention of MDRPI.
METHODS
We searched PubMed, Embase, Web of Science, China National Knowledge Infrastructure (CNKI), WanFang Database, and China BioMedical Literature Database (CBM) (from inception to January 2023) for studies that identified risk factors of MDRPI in ICU patients. In order to avoid the omission of relevant literature, we performed a secondary search of the above database on February 15, 2023. Meta-analysis was performed using Revman 5.3.
RESULTS
Fifteen studies involving 4850 participants were selected to analyze risk factors for MDRPI in ICU patients. While conducting a meta-analysis, we used sensitivity analysis to ensure the reliability of the results for cases with significant heterogeneity among studies. When the source of heterogeneity cannot be determined, we only described the risk factor. The risk factors for MDRPI in ICU patients were elder age (OR = 1.06, 95% CI: 1.03-1.10), diabetes mellitus (OR = 3.20, 95% CI: 1.96-5.21), edema (OR = 3.62, 95% CI: 2.31-5.67), lower Braden scale score (OR = 1.22, 95%CI: 1.11-1.33), higher SOFA score (OR = 4.21, 95%CI: 2.38-7.47), higher APACHE II score (OR = 1.38, 95%CI: 1.15-1.64), longer usage time of medical devices (OR = 1.11, 95%CI: 1.05-1.19), use of vasoconstrictors (OR = 6.07, 95%CI: 3.15-11.69), surgery (OR = 4.36, 95% CI: 2.07-9.15), prone position (OR = 24.71, 95% CI: 7.34-83.15), and prone position ventilation (OR = 17.51, 95% CI: 5.86-52.36). Furthermore, we found that ICU patients who used subglottic suction catheters had a higher risk of MDRPI, whereas ICU patients with higher hemoglobin and serum albumin levels had a lower risk of MDRPI.
CONCLUSION
This study reported the risk factors for MDRPI in ICU patients. A comprehensive analysis of these risk factors will help to prevent and optimize interventions, thereby minimizing the occurrence of MDRPI.
Topics: Humans; Aged; Pressure Ulcer; Reproducibility of Results; Intensive Care Units; Critical Care; Crush Injuries; Risk Factors
PubMed: 37352180
DOI: 10.1371/journal.pone.0287326 -
European Spine Journal : Official... Mar 2022The considered benefit of surgical drain use after spinal surgery is to prevent local accumulation of a haematoma by decompressing the closed space in the approach of... (Review)
Review
PURPOSE
The considered benefit of surgical drain use after spinal surgery is to prevent local accumulation of a haematoma by decompressing the closed space in the approach of the surgical site. In this context, the aim of the present systematic review was to prove the benefit of the routine use of closed-suction drains.
METHODS
We conducted a comprehensive systematic review of the literature according to the Preferred reporting items for systematic reviews and meta-analyses (PRISMA) checklist and algorithm.
RESULTS
Following the literature search, 401 potentially eligible investigations were identified. Eventually, a total of 24 studies with 8579 participants were included. Negative suction drainage led to a significantly higher volume of drainage fluid. Drainage duration longer than 72 h may be associated with a higher incidence of Surgical side infections (SSI); however, accompanying antibiotic treatment is unnecessary. Regarding postoperative haematoma and neurological complications, no evidence exists concerning their prevention. Hospital stay length and related costs may be elevated in patients with drainage but appear to depend on surgery type.
CONCLUSIONS
With regard to the existing literature, the use of closed-suction drainage in elective thoracolumbar spinal surgery is not associated with any proven benefit for patients and cannot decrease postoperative complications.
Topics: Drainage; Humans; Length of Stay; Postoperative Complications; Suction; Surgical Wound Infection
PubMed: 35092451
DOI: 10.1007/s00586-021-07079-6 -
Cureus Jul 2023Airway suctioning is routinely performed in the majority of care circumstances, including acute care, subacute care, home-based settings, and long-term care. Using an... (Review)
Review
Airway suctioning is routinely performed in the majority of care circumstances, including acute care, subacute care, home-based settings, and long-term care. Using an artificial airway to suction the patient allows for the mobilization and evacuation of secretions. When a patient can't independently remove all of the secretions from their respiratory tract, suction is used. This can occur when the body produces excessive secretion or it is not eliminated quickly enough, causing the respiratory system's upper and lower respiratory secretions to accumulate. Airway blockage and inadequate breathing may result from this. Ultimately, this leads to a shortage of oxygen and carbon dioxide from the air, both of which are necessary for ideal cellular activity. Artificial airway suctioning is one of the most crucial components of airway care and a core competency for medical professionals trying to ensure airway patency. Artificial airway suctioning is a standard treatment carried out every day globally and is frequently done in both outpatient and inpatient patients. Therefore, specialists must know the safest and most efficient ways to perform surgery and any potential side effects. In ventilated infants and children, the removal of obstructive secretions by endotracheal suctioning is frequently done. It is unknown how suctioning affects the mechanics of breathing. This study used a prospective observational clinical design to examine the immediate impact of airway resistance in endotracheal suctioning, tidal volume, and dynamic lung regulation in mechanically ventilated adult patients and mechanically ventilated pediatric patients. The preparation, process, and indications for intraoperative fusion treatment in various circumstances are covered in this systematic review.
PubMed: 37641766
DOI: 10.7759/cureus.42579 -
Surgical Endoscopy Jun 2024Appendicitis is an extremely common disease with a variety of medical and surgical treatment approaches. A multidisciplinary expert panel was convened to develop...
BACKGROUND
Appendicitis is an extremely common disease with a variety of medical and surgical treatment approaches. A multidisciplinary expert panel was convened to develop evidence-based recommendations to support clinicians and patients in decisions regarding the diagnosis and treatment of appendicitis.
METHODS
A systematic review was conducted from 2010 to 2022 to answer 8 key questions relating to the diagnosis of appendicitis, operative or nonoperative management, and specific technical and post-operative issues for appendectomy. The results of this systematic review were then presented to a panel of adult and pediatric surgeons. Evidence-based recommendations were formulated using the GRADE methodology by subject experts.
RESULTS
Conditional recommendations were made in favor of uncomplicated and complicated appendicitis being managed operatively, either delayed (>12h) or immediate operation (<12h), either suction and lavage or suction alone, no routine drain placement, treatment with short-term antibiotics postoperatively for complicated appendicitis, and complicated appendicitis previously treated nonoperatively undergoing interval appendectomy. A conditional recommendation signals that the benefits of adhering to a recommendation probably outweigh the harms although it does also indicate uncertainty.
CONCLUSIONS
These recommendations should provide guidance with regard to current controversies in appendicitis. The panel also highlighted future research opportunities where the evidence base can be strengthened.
Topics: Appendicitis; Humans; Appendectomy; Anti-Bacterial Agents; Evidence-Based Medicine
PubMed: 38740595
DOI: 10.1007/s00464-024-10813-y -
Endoscopic Ultrasound 2021The optimal sampling techniques for EUS-FNA remain unclear and have not been standardized. To improve diagnostic accuracy, suction techniques for EUS-FNA have been... (Review)
Review
The optimal sampling techniques for EUS-FNA remain unclear and have not been standardized. To improve diagnostic accuracy, suction techniques for EUS-FNA have been developed and are widely used among endoscopists. The aim of this study was to compare wet-suction and dry-suction EUS-FNA techniques for sampling solid lesions. We performed a comprehensive literature search of major databases (from inception to June 2020) to identify prospective studies comparing wet-suction EUS-FNA and dry-suction EUS-FNA. Specimen adequacy, sample contamination, and histologic accuracy were assessed by pooling data using a random-effects model expressed in terms of odds ratio (OR) and 95% confidence interval (CI). Six studies including a total of 418 patients (365 wet suction vs. 377 dry suction) were included in our final analysis. The study included a total of 535 lesions (332 pancreatic lesions and 203 nonpancreatic lesions). The pooled odds of sample adequacy was 3.18 (CI: 1.82-5.54, P = 0.001) comparing wet- and dry-suction cohorts. The pooled odds of blood contamination was 1.18 (CI: 0.75-1.86, P = 0.1). The pooled rate for blood contamination was 58.33% (CI: 53.65%-62.90%) in the wet-suction cohort and 54.60% (CI 49.90%- 59.24%) in the dry-suction cohort (P = 0.256). The pooled odds of histological diagnosis was 3.68 (CI 0.82-16.42, P = 0.1). Very few adverse events were observed and did not have an impact on patient outcomes using either method. EUS-FNA using the wet-suction technique offers higher specimen quality through comparable rates of blood contamination and histological accuracy compared to dry-suction EUS-FNA.
PubMed: 34259217
DOI: 10.4103/EUS-D-20-00198 -
European Urology Focus Jan 2024Controversy exists regarding the therapeutic benefit of suction use during percutaneous nephrolithotripsy (PCNL). (Review)
Review
CONTEXT
Controversy exists regarding the therapeutic benefit of suction use during percutaneous nephrolithotripsy (PCNL).
OBJECTIVE
To review and highlight the options available in the use of suction for PCNL, and to discuss their strengths and limitations.
EVIDENCE ACQUISITION
A systematic literature search was performed using Scopus, EMBASE, and PubMed. Thirty four studies were included. There was one ex vivo study. Among clinical studies, 24 used a vacuum/suctioning sheath and nine a handpiece suction device/direct-in-scope suction. The suction technique was employed in standard, mini-PCNL, supermini-PCNL, and enhanced supermini‑PCNL techniques.
EVIDENCE SYNTHESIS
Handpiece suction devices demonstrated better safety and efficiency in treating large stones than nonsuction PCNL and in a much shorter time. Trilogy and ShockPulse-SE were equally effective, safe, and versatile for standard PCNL and mini-PCNL. The heavier handpiece makes Trilogy less ergonomically friendly. Laser suction handpiece devices can potentiate laser lithotripsy by allowing for better laser control with simultaneous suction of small fragments and dust. Integrated suction-based sheaths are available in reusable and disposable forms for mini-PCNL only. Mini-PCNL with suction reported superior outcomes for operative time and stone-free rate to mini-PCNL. This also helped minimize infectious complications by a combination of intrarenal pressure reduction and faster aspiration of irrigation fluid reducing the risk of sepsis, enhance intraoperative vision, and improve lithotripsy efficiency, which makes it a very attractive evolution for PCNL.
CONCLUSIONS
Suction devices in PCNL are reforming the way PCNL is being done. Adding suction to mini-PCNL reduces infectious complications and improves the stone-free rate. Our review shows that despite the limited evidence, suction techniques appear to improve PCNL outcomes.
PATIENT SUMMARY
In this review, we looked at the intra- and perioperative outcomes of percutaneous nephrolithotripsy (PCNL) with the addition of suction. With better stone fragmentation and fewer postoperative infections, this technology is very useful particularly for mini-PCNL.
Topics: Humans; Kidney Calculi; Suction; Lithotripsy; Lithotripsy, Laser; Postoperative Complications
PubMed: 37442721
DOI: 10.1016/j.euf.2023.06.010 -
Vascular Medicine (London, England) Dec 2022There are no randomized trials studying the outcomes of mechanical aspiration thrombectomy (MAT) for management of pulmonary embolism (PE). (Meta-Analysis)
Meta-Analysis
INTRODUCTION
There are no randomized trials studying the outcomes of mechanical aspiration thrombectomy (MAT) for management of pulmonary embolism (PE).
METHODS
We performed a systematic review and meta-analysis of existing literature to evaluate the safety and efficacy of MAT in the setting of PE. Inclusion criteria were as follows: studies reporting more than five patients, study involved MAT, and reported clinical outcomes and pulmonary artery pressures. Studies were excluded if they failed to separate thrombectomy data from catheter-directed thrombolysis data. Databases searched include PubMed, EMBASE, Web of Science until April, 2021.
RESULTS
Fourteen case series were identified, consisting of 516 total patients (mean age 58.4 ± 13.6 years). Three studies had only high-risk PE, two studies had only intermediate-risk PE, and the remaining nine studies had a combination of both high-risk and intermediate-risk PE. Six studies used the Inari FlowTriever device, five studies used the Indigo Aspiration system, and the remaining three studies used the Rotarex or Aspirex suction thrombectomy system. Four total studies employed thrombolytics in a patient-specific manner, with seven receiving local lysis and 17 receiving systemic lysis, and 40 receiving both. A random-effects meta-analyses of proportions of in-hospital mortality, major bleeding, technical success, and clinical success were calculated, which yielded estimate pooled percentages [95% CI] of 3.6% [0.7%, 7.9%], 0.5% [0.0%, 1.8%], 97.1% [94.8%, 98.4%], and 90.7% [85.5%, 94.3%].
CONCLUSION
There is significant heterogeneity in clinical, physiologic, and angiographic data in the currently available data on MAT. RCTs with consistent parameters and outcomes measures are still needed.
Topics: Adult; Aged; Humans; Middle Aged; Pulmonary Embolism; Thrombectomy; Suction
PubMed: 36373768
DOI: 10.1177/1358863X221124681 -
Gastrointestinal Endoscopy May 2023Evidence is limited on the comparative diagnostic performance of tissue sampling techniques for EUS-guided fine-needle biopsy sampling of pancreatic masses. We performed... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND AND AIMS
Evidence is limited on the comparative diagnostic performance of tissue sampling techniques for EUS-guided fine-needle biopsy sampling of pancreatic masses. We performed a systematic review with network meta-analysis to compare these techniques.
METHODS
Rates of sample adequacy, blood contamination, and tissue integrity using fine-needle biopsy sampling needles were evaluated. Direct and indirect comparisons were performed among the slow-pull, dry-suction, modified wet-suction, or no-suction techniques. Results are expressed as risk ratio (RR) and 95% confidence interval (CI).
RESULTS
Overall, 9 randomized controlled trials (756 patients) were identified. On network meta-analysis, the no-suction technique was significantly inferior to the other techniques (RR, .85 [95% CI, .78-.92] vs slow pull; RR, .85 [95% CI, .78-.92] vs dry suction; RR, .83 [95% CI, .76-.90] vs modified wet suction) in terms of sample adequacy. Consequently, modified wet suction was shown to be the best technique (surface under the cumulative ranking curve score, .90), with the no-suction technique showing poorer performance in terms of sample adequacy (surface under the cumulative ranking curve score, .14). Dry suction was associated with significantly higher rates of blood contamination as compared with the slow-pull technique (RR, 1.44; 95% CI, 1.15-1.80), whereas no suction led to less blood contamination of samples in comparison with other techniques (RR, .71 [95% CI, .52-.97] vs slow pull; RR, .49 [95% CI, .36-.66] vs dry suction; RR, .57 [95% CI, .40-.81] vs modified wet suction). The modified wet-suction technique significantly outperformed dry suction in terms of tissue integrity of the sample (RR, 1.36; 95% CI, 1.06-1.75).
CONCLUSIONS
Modified wet suction seemed to provide high rates of integrity and adequate samples, albeit with high blood contamination. The no-suction technique performed significantly worse than other sampling strategies.
Topics: Humans; Pancreatic Neoplasms; Network Meta-Analysis; Endoscopic Ultrasound-Guided Fine Needle Aspiration; Suction
PubMed: 36657607
DOI: 10.1016/j.gie.2023.01.024 -
Current Opinion in Urology Jul 2023Retrograde intra renal surgery (RIRS) with laser lithotripsy represents the gold-standard to treat renal stones up to 20 mm. Controlling intraoperative parameters such...
PURPOSE OF REVIEW
Retrograde intra renal surgery (RIRS) with laser lithotripsy represents the gold-standard to treat renal stones up to 20 mm. Controlling intraoperative parameters such as intrarenal pressure (IRP) and temperature (IRT) is mandatory to avoid complications. This article reviews advances in IRP and IRT over the last 2 years.
RECENT FINDINGS
We conducted a PubMed/Embase search and reviewed publications that include temperature and pressure during RIRS. Thirty-four articles have been published which met the inclusion criteria. Regarding IRP, a consensus has emerged to control IRP during RIRS, in order to avoid (barotraumatic and septic) complications. Several monitoring devices are under evaluation but none of them are clinically approved for RIRS. Ureteral access sheath, low irrigation pressure and occupied working channel help to maintain a low IRP. Robotic systems and suction devices would improve IRP intraoperative management and monitoring. IRT determinants are the irrigation flow and laser settings. Low power settings(<20 W) with minimal irrigation flow (5-10 ml/min) are sufficient to maintain low IRT and allows continuous laser activation.
SUMMARY
Recent evidence suggests that IRP and IRT are closely related. IRP depends on inflow and outflow rates. Continuous monitoring would help to avoid surgical and infectious complications. IRT depends on the laser settings and the irrigation flow.
Topics: Humans; Temperature; Kidney; Kidney Calculi; Ureter; Lithotripsy, Laser
PubMed: 37140545
DOI: 10.1097/MOU.0000000000001102