Materials (Basel, Switzerland) Apr 2020The advent of new technologies in the field of medicine and dentistry is giving improvements that lead the clinicians to have materials and procedures able to improve... (Review)
Review
The advent of new technologies in the field of medicine and dentistry is giving improvements that lead the clinicians to have materials and procedures able to improve patients' quality of life. In dentistry, the last digital techniques offer a fully digital computerized workflow that does not include the standard multiple traditional phases. The purpose of this study is to evaluate all clinical trials and clinical randomized trials related to the digital or dental impression technique in prosthetic dentistry trying to give the readers global information about advantages and disadvantages of each procedure. Data collection was conducted in the main scientific search engines, including articles from the last 10 years, in order to obtain results that do not concern obsolete impression techniques. Elsevier, Pubmed and Embase have been screened as sources for performing the research. The results data demonstrated how the working time appears to be improved with digital workflow, but without a significant result (P = 0.72596). The papers have been selected following the Population Intervention Comparison Outcome (PICO) question, which is related to the progress on dental impression materials and technique. The comparison between dentists or practitioners with respect to classic impression procedures, and students open to new device and digital techniques seem to be the key factor on the final impression technique choice. Surely, digital techniques will end up supplanting the analogical ones altogether, improving the quality of oral rehabilitations, the economics of dental practice and also the perception by our patients.
PubMed: 32340384
DOI: 10.3390/ma13081982 -
Bioengineering (Basel, Switzerland) Mar 2022Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants... (Review)
Review
Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants are used; however, no sole disinfectant can be designated as universal for all the impression materials. Thus, the aim of this study is to systemically review the literature to evaluate the effect of the existing disinfection procedures on the bacterial colonization of dental impression materials. This systematic review and meta-analysis was conducted according to the PRISMA statement. PubMed (MEDLINE), Web of Science, Scopus, EMBASE, and SciELO databases were screened up to April 2021. Eligibility criteria included in vitro studies reporting the antibacterial activity of disinfectant solutions in dental impression materials. The meta-analysis was performed using Review Manager (version 5.3.5). A global comparison was performed with the standardized mean difference based on random-effect models at a significance level of α = 0.05. A total of seven studies were included in the meta-analysis. The included studies described the effect of disinfection processes with chlorhexidine gluconate, alcohol, sodium hypochlorite, glutaraldehyde, and hydrogen peroxide in alginate, polyvinyl siloxane, and polyether impression materials. The meta-analyses showed that the use of chlorhexidine, alcohol, glutaraldehyde, and sodium hypochlorite reduced the colony-forming units by a milliliter (CFU/mL) in alginate (p < 0.001). On the other hand, glutaraldehyde, sodium hypochlorite, and alcohol reduced the CFU/mL in polyvinyl siloxane (p < 0.001). Finally, alcohol and glutaraldehyde reduced the CFU/mL in polyether material (p < 0.001). High heterogenicity was observed for the alginate and polyvinyl siloxane materials (I2 = 74%; I2 = 90%). Based on these in vitro studies, the disinfection of impression materials with several disinfection agents reduces the CFU/mL count.
PubMed: 35324812
DOI: 10.3390/bioengineering9030123 -
Journal of International Society of... 2020The purpose of this study is to compare digital and conventional impression methods by preclinical students in terms of time and ease and to evaluate their preferences...
AIMS AND OBJECTIVES
The purpose of this study is to compare digital and conventional impression methods by preclinical students in terms of time and ease and to evaluate their preferences and future expectations.
MATERIALS AND METHODS
Twenty volunteered, 2 year preclinical students (11 females and 9 males) participated in this study. Students took digital and conventional impressions of the left lower first molar which was made full ceramic crown preparation and opposite full arch from a typodont model (Frasaco, Frasaco GmbH, Tettnang, Germany). They used intraoral scanner (CEREC Omnicam, Sirona Dental GmbH, Bensheim, Germany) for digital impression and also used additional type (Express XT Penta H, 3M ESPE, Seefeld, Germany) and condensation type (Zetaplus, Zhermack SpA, Badia Polesine, Italy) silicones for conventional impression. Their taking impression time was measured. Before taking impression and after taking impression, two kinds of questionnaires were conducted to students about their preference, ease of impression methods, and their future expectations. Statistical analysis was performed by IBM SPSS 23 and Excel 2010 version. Differences between conventional and digital impression in terms of time were analyzed by student's-t paired test and effect of gender was analyzed by students's-t independent test.
RESULTS
There were statistically significant differences between digital and conventional impression methods in terms of taking impression and total impression time ( < 0.001). But there wasn't any statistically significant difference between two methods in terms of preparation time. About 85% of students preferred the digital impression method and also 85% of students found that the digital impression method was easy. 95% of students expected to find intraoral scanner in the clinic where working first time.
CONCLUSIONS
As a result of this study, it has been seen that the students preferred the digital impression method to the conventional impression method and found that the digital impression method was easier.
PubMed: 33042880
DOI: 10.4103/jispcd.JISPCD_330_18 -
Journal of Advanced Pharmaceutical... Dec 2022The present invention relates to dental compositions that include a phosphorescent material, more particularly, adding phosphorescent material to waxes that used in...
The present invention relates to dental compositions that include a phosphorescent material, more particularly, adding phosphorescent material to waxes that used in dentistry. The aim of the study is to develop a wax that has innate phosphorescent properties. Three groups of samples were taken in which the phosphorescent material was added. Three groups were later compared for their phosphorescent property in the material. All the samples in the initial molten state were poured into a mold made of silicone impression material and allowed to set. The material was placed in a dark room, and visual examination was done to compare the materials. From the samples obtained, paraffin wax showed more phosphorescent property than beeswax. The least phosphorescent property was seen in marginal wax. It can be concluded from this study that paraffin wax showed the most phosphorescent property.
PubMed: 36798543
DOI: 10.4103/japtr.japtr_195_22 -
Journal of Indian Prosthodontic Society 2023The present study was done to evaluate the knowledge and awareness of different provisional materials, especially polycaprolactone (PCL) and their application in...
AIM
The present study was done to evaluate the knowledge and awareness of different provisional materials, especially polycaprolactone (PCL) and their application in prosthodontic practice.
SETTING AND DESIGN
A questionnaire based survey was carried out to assess the knowledge and awareness of PCL and its applications as provisional material in prosthodontic practice.
MATERIALS AND METHOD
A questionnaire-based descriptive study consisting of 10 questions related to different provisional materials and their applications in prosthodontic practice was formulated on Google Forms. The link was created and circulated among the prosthodontist faculty members of various dental institutes and private practitioners of India with the use of digital platforms such as E-mail and social media. The data were collected and examined using Microsoft Excel software for statistical evaluation.
STATISTICAL ANALYSIS USED
For this descriptive type of study, knowledge and awareness among prosthodontists across India was evaluated using Microsoft Excel software.
RESULTS
The use of PCL was known only to 20.75% of prosthodontists. Moreover, its application and indications are known to only <1% of the study participants. Autopolymerizing resin was most commonly used for the custom tray and temporary base fabrication as well as temporization in crown and bridge prosthesis, while muscle deprogrammer and surgical template were commonly fabricated in heat-cure and clear acrylic resin, respectively. Pattern resin was found to be commonly used in splinting implant impression copings.
CONCLUSION
The use of PCL as a temporary denture base, custom tray, muscle deprogrammer, implant impression splinting, and provisional for crown and bridge and templates should be encouraged and incorporated to get benefits of its characteristic properties. Considering the overall performance of PCL, its use should be incorporated into prosthodontic research and practice.
Topics: Humans; Prosthodontics; Acrylic Resins; Dental Restoration, Temporary; Surveys and Questionnaires
PubMed: 36588379
DOI: 10.4103/jips.jips_224_22 -
Polymers Jul 2022The paper presents the influence of impression methods, polymer materials, and implant angulation on the accuracy of the definitive working model for the production of...
The paper presents the influence of impression methods, polymer materials, and implant angulation on the accuracy of the definitive working model for the production of implant-supported dental restorations, based on the analysis of results obtained using different impression methods, materials, and parallel and angulated implants. The study findings indicate that all aforementioned factors impact the accuracy of the definitive working model. Specifically, 20° implant angulation in relation to the vertical plane has a greater impact on the impression accuracy compared to parallel implants. The open and splint method in combination with addition silicone, as well as the splint method and polyether combination yielded more accurate results when using implants under 20° angulation compared to other method and material combinations. The splint method in combination with addition silicone resulted in the smallest mean deviations from the center of the parallel implant base compared to other combinations of methods and materials. Analysis results further revealed statistically significant differences in the measured indicators across impression methods, implants, and polymer materials.
PubMed: 35890598
DOI: 10.3390/polym14142821 -
Acta Stomatologica Croatica Sep 2021Hydrophilicity of dental impression materials is crucial for obtaining an accurate impression and necessary for the production of a well-fitting cast restoration. The...
INTRODUCTION
Hydrophilicity of dental impression materials is crucial for obtaining an accurate impression and necessary for the production of a well-fitting cast restoration. The most common technique for evaluation of hydrophilicity is a contact angle measurement. The aim of the present study was to compare the water contact angles of four groups of elastomeric impression materials, before and during setting.
MATERIAL AND METHODS
Flattened specimens (n=10) of tested impression materials were prepared by the use of a Teflon mold with specific dimensions. A 5μl droplet of deionized water fell on the specimen, and photos were taken using a Nikon D3200 DSLR camera and a 105 mm macro lens (Nikorr, Nikon) in specific time points.
RESULTS
The CAD/CAM material showed the highest contact angle measurements. The light body polyvinylsiloxane (PVS) material 1, polyether and vinylsiloxanether material showed comparable contact angle measurements especially at the initial time point. A statistically significant reduction of contact angles was reported during setup time for all PVS, PE and vinylsiloxanether materials, while the most expressed reduction of contact angle measurements, and thus the most significant increase of hydrophilicity were reported for light wash PVS material 2.
CONCLUSIONS
The CAD/CAM impression material showed the most hydrophobic behavior. PVS materials showed excellent hydrophilicity. Polyether and polyvinyloxanether impression materials presented lower contact angle measurements, and thus superior hydrophilicity, compared with other tested materials initially and during setting. All tested impression materials presented a stepwise development of hydrophilicity during the setting stage.
PubMed: 34658372
DOI: 10.15644/asc55/3/3 -
Cureus Jan 2024The accuracy of definitive impressions has a significant impact on the quality of the final prosthesis. Elastic impression materials are commonly used in the traditional... (Review)
Review
The accuracy of definitive impressions has a significant impact on the quality of the final prosthesis. Elastic impression materials are commonly used in the traditional approach to replicate anatomical structures while indirectly fabricating prostheses. Digital impression has gained increasing popularity due to its various advantages, including three-dimensional previsualization, cost-effectiveness, and reduced time consumption. The objective of this study is to evaluate existing studies to provide an overview of the comparative advantages of digital impression techniques over conventional techniques. The review will focus on evaluating the accuracy, patient acceptability, operator preference, and time effectiveness of digital impression techniques in comparison to conventional techniques. The Population, Intervention, Comparison, and Outcome framework served as the basis for this study's search strategy. We conducted a comprehensive literature review by electronically searching articles published between 2000 and 2023 in PubMed, Medline, Cochrane, and the Web of Science. Furthermore, additional manual searches were conducted. The study examined the differences between optical impressions and traditional impressions in terms of accuracy, patient outcomes, and operator outcomes. It included both clinical and preclinical studies as well as randomized controlled trials. In conclusion, this review provides a short summary indicating that digital impressions exhibit comparable accuracy to conventional impressions without any statistically significant difference. This conclusion is based on an evaluation of accuracy, patient preference, and operator preference.
PubMed: 38304652
DOI: 10.7759/cureus.51537 -
Clinical Oral Implants Research Jun 2022The use of intraoral scanners (IOSs) for digital implant impressions in daily clinical practice is increasing. However, no structured literature review on the accuracy... (Review)
Review
OBJECTIVES
The use of intraoral scanners (IOSs) for digital implant impressions in daily clinical practice is increasing. However, no structured literature review on the accuracy of digital implant impressions in clinical studies has been described to date. Therefore, this systematic review aimed to answer the PICO question: Which accuracy is described for digital implant impressions in clinical studies?
MATERIAL AND METHODS
An electronic database search was conducted in December 2021 using MeSH terms and free-text search. English-language studies addressing the accuracy of digital implant impressions in clinical studies involving at least 10 patients were included. All clinical indications were considered.
RESULTS
Eight publications between 2014 and 2021 matched the review criteria. However, the study designs showed considerable differences. The number of implants within the studies ranged from 1 to 6, and the number of patients ranged from 10 to 39. The oldest study (2014) revealed the highest deviation for linear distances at 1000 ± 650 µm, whereas the other studies reported data in the range of 360 ± 46 µm to 40 ± 20 µm. In one study, no numerical data were reported and all studies compared digital and conventional implant impressions.
CONCLUSIONS
The number of clinical studies on the accuracy of digital implant impressions is low. Thus, the impact of different factors, such as the scanpath or scanbody, could not be identified. However, the accuracy of recent IOSs for digital implant impressions in patients was shown to be clinically acceptable. Nevertheless, the transfer error still needs to be considered when fabricating implant-supported restorations.
Topics: Computer-Aided Design; Databases, Factual; Dental Implants; Dental Impression Technique; Humans; Imaging, Three-Dimensional; Models, Dental
PubMed: 35527511
DOI: 10.1111/clr.13951 -
Nigerian Journal of Clinical Practice Apr 2022Surgical procedures in posterior area of maxillary might cause an oroantral communication and iatrogenic sinusitis. An undetected oroantral communication can cause the... (Review)
Review
Surgical procedures in posterior area of maxillary might cause an oroantral communication and iatrogenic sinusitis. An undetected oroantral communication can cause the penetration of foreign bodies, such as dental impression materials, in the maxillary sinus, thereby contributing to persistent sinusitis. Given the occurrence of a very rare clinical and medicolegal case of persistent and drug-resistant sinusitis due to radiologically undetected fragments of silicone paste for dental impression in the maxillary antrum, a literature review was pursued through sensitive keywords in relevant databases for health sciences. All retrieved articles were considered and data about the kind of impression materials thrusted into the maxillary sinus, the diagnostic issues, the reported range of symptoms, and the occurrence of medicolegal issues were analyzed. The diagnosis resulted to be quite challenging and belatedly especially in case of healed oroantral communication and when the material retained in the maxillary sinus has similar radiodensity compared to the surrounding normal or inflammatory tissues. The case was then discussed in comparison with the reviewed literature for both clinical and medicolegal issues. Hints were provided to professionals to face the challenging diagnosis in similar rare cases and to avoid the possible related litigation.
Topics: Foreign Bodies; Humans; Maxillary Sinus; Maxillary Sinusitis; Oroantral Fistula; Sinusitis
PubMed: 35439893
DOI: 10.4103/njcp.njcp_1662_21