Heliyon Oct 2020Accurate, robust and reproducible delineation of tumour in Positron Emission Tomography (PET) is essential for diagnosis, treatment planning and response assessment.... (Review)
Review
Accurate, robust and reproducible delineation of tumour in Positron Emission Tomography (PET) is essential for diagnosis, treatment planning and response assessment. Since standardized uptake value (SUV) - a normalized semiquantitative parameter used in PET is represented by the intensity of the PET images and related to the radiotracer uptake, a SUV based threshold method is a natural choice to delineate the tumour. However, determination of an optimum threshold value is a challenging task due to low spatial resolution, and signal-to-noise ratio (SNR) along with finite image sampling constraint. The aim of the review is to summarize different fixed and adaptive threshold-based PET image segmentation approaches under a common mathematical framework Advantages and disadvantages of different threshold based methods are also highlighted from the perspectives of diagnosis, treatment planning and response assessment. Several fixed threshold values (30%-70% of the maximum SUV of the tumour (SUV)) have been investigated. It has been reported that the fixed threshold-based method is very much dependent on the SNR, tumour to background ratio (TBR) and the size of the tumour. Adaptive threshold-based method, an alternative to fixed threshold, can minimize these dependencies by accounting for tumour to background ratio (TBR) and tumour size. However, the parameters for the adaptive methods need to be calibrated for each PET camera system (e.g., scanner geometry, image acquisition protocol, reconstruction algorithm etc.) and it is not straight forward to implement the same procedure to other PET systems to obtain similar results. It has been reported that the performance of the adaptive methods is also not optimum for smaller volumes with lower TBR and SNR. Statistical analysis carried out on the NEMA thorax phantom images also indicates that regions segmented by the fixed threshold method are significantly different for all cases. On the other hand, the adaptive method provides significantly different segmented regions only for low TBR with different SNR. From this viewpoint, a robust threshold based segmentation method that will be less sensitive to , SNR, TBR and volume needs to be developed. It was really challenging to compare the performance of different threshold-based methods because the performance of each method was tested on dissimilar data set with different data acquisition and reconstruction protocols along with different TBR, SNR and volumes. To avoid such difficulties, it will be desirable to have a common database of clinical PET images acquired with different image acquisition protocols and different PET cameras to compare the performance of automatic segmentation methods. It is also suggested to report the changes in SNR and TBR while reporting the response using threshold based methods.
PubMed: 33163642
DOI: 10.1016/j.heliyon.2020.e05267 -
European Journal of Nuclear Medicine... Dec 2021In this contribution, several opportunities and challenges for long axial field of view (LAFOV) PET are described. It is an anthology in which the main issues have been... (Review)
Review
In this contribution, several opportunities and challenges for long axial field of view (LAFOV) PET are described. It is an anthology in which the main issues have been highlighted. A consolidated overview of the camera system implementation, business and financial plan, opportunities and challenges is provided. What the nuclear medicine and molecular imaging community can expect from these new PET/CT scanners is the delivery of more comprehensive information to the clinicians for advancing diagnosis, therapy evaluation and clinical research.
Topics: Humans; Molecular Imaging; Nuclear Medicine; Positron Emission Tomography Computed Tomography; Positron-Emission Tomography
PubMed: 34136956
DOI: 10.1007/s00259-021-05461-6 -
Journal of Applied Clinical Medical... Jun 2020The novel scintillator-based system described in this study is capable of accurately and remotely measuring surface dose during Total Skin Electron Therapy (TSET); this...
PURPOSE
The novel scintillator-based system described in this study is capable of accurately and remotely measuring surface dose during Total Skin Electron Therapy (TSET); this dosimeter does not require post-exposure processing or annealing and has been shown to be re-usable, resistant to radiation damage, have minimal impact on surface dose, and reduce chances of operator error compared to existing technologies e.g. optically stimulated luminescence detector (OSLD). The purpose of this study was to quantitatively analyze the workflow required to measure surface dose using this new scintillator dosimeter and compare it to that of standard OSLDs.
METHODS
Disc-shaped scintillators were attached to a flat-faced phantom and a patient undergoing TSET. Light emission from these plastic discs was captured using a time-gated, intensified, camera during irradiation and converted to dose using an external calibration factor. Time required to complete each step (daily QA, dosimeter preparation, attachment, removal, registration, and readout) of the scintillator and OSLD surface dosimetry workflows was tracked.
RESULTS
In phantoms, scintillators and OSLDs surface doses agreed within 3% for all data points. During patient imaging it was found that surface dose measured by OSLD and scintillator agreed within 5% and 3% for 35/35 and 32/35 dosimetry sites, respectively. The end-to-end time required to measure surface dose during phantom experiments for a single dosimeter was 78 and 202 sec for scintillator and OSL dosimeters, respectively. During patient treatment, surface dose was assessed at 7 different body locations by scintillator and OSL dosimeters in 386 and 754 sec, respectively.
CONCLUSION
Scintillators have been shown to report dose nearly twice as fast as OSLDs with substantially less manual work and reduced chances of human error. Scintillator dose measurements are automatically saved to an electronic patient file and images contain a permanent record of the dose delivered during treatment.
Topics: Electrons; Humans; Phantoms, Imaging; Radiation Dosimeters; Radiometry; Workflow
PubMed: 32306551
DOI: 10.1002/acm2.12880 -
Scientific Reports Sep 2021The radioiodine isotope pair I/I is used in a theranostic approach for patient-specific treatment of differentiated thyroid cancer. Lesion detectability is notably...
The radioiodine isotope pair I/I is used in a theranostic approach for patient-specific treatment of differentiated thyroid cancer. Lesion detectability is notably higher for I PET (positron emission tomography) than for I gamma camera imaging but can be limited for small and low uptake lesions. The recently introduced silicon-photomultiplier-based (SiPM-based) PET/CT (computed tomography) systems outperform previous-generation systems in detector sensitivity, coincidence time resolution, and spatial resolution. Hence, SiPM-based PET/CT shows an improved detectability, particularly for small lesions. In this study, we compare the size-dependant minimum detectable I activity (MDA) between the SiPM-based Biograph Vision and the previous-generation Biograph mCT PET/CT systems and we attempt to predict the response to I radioiodine therapy of lesions additionally identified on the SiPM-based system. A tumour phantom mimicking challenging conditions (derived from published patient data) was used; i.e., 6 small spheres (diameter of 3.7-9.7 mm), 9 low activity concentrations (0.25-25 kBq/mL), and a very low signal-to-background ratio (20:1). List-mode emission data (single-bed position) were divided into frames of 4, 8, 16, and 30 min. Images were reconstructed with ordinary Poisson ordered-subsets expectation maximization (OSEM), additional time-of-flight (OSEM-TOF) or TOF and point spread function modelling (OSEM-TOF+PSF). The signal-to-noise ratio and the MDA were determined. Absorbed dose estimations were performed to assess possible treatment response to high-activity I radioiodine therapy. The signal-to-noise ratio and the MDA were improved from the mCT to the Vision, from OSEM to OSEM-TOF and from OSEM-TOF to OSEM-TOF+PSF reconstructed images, and from shorter to longer emission times. The overall mean MDA ratio of the Vision to the mCT was 0.52 ± 0.18. The absorbed dose estimations indicate that lesions ≥ 6.5 mm with expected response to radioiodine therapy would be detectable on both systems at 4-min emission time. Additional smaller lesions of therapeutic relevance could be detected when using a SiPM-based PET system at clinically reasonable emission times. This study demonstrates that additional lesions with predicted response to I radioiodine therapy can be detected. Further clinical evaluation is warranted to evaluate if negative I PET scans on a SiPM-based system can be sufficient to preclude patients from blind radioiodine therapy.
PubMed: 34471170
DOI: 10.1038/s41598-021-95719-8 -
Annals of Nuclear Medicine Oct 2022Head motions during brain PET scan cause degradation of brain images, but head fixation or external-maker attachment become burdensome on patients. Therefore, we have...
OBJECTIVE
Head motions during brain PET scan cause degradation of brain images, but head fixation or external-maker attachment become burdensome on patients. Therefore, we have developed a motion correction method that uses a 3D face-shape model generated by a range-sensing camera (Kinect) and by CT images. We have successfully corrected the PET images of a moving mannequin-head phantom containing radioactivity. Here, we conducted a volunteer study to verify the effectiveness of our method for clinical data.
METHODS
Eight healthy men volunteers aged 22-45 years underwent a 10-min head-fixed PET scan as a standard of truth in this study, which was started 45 min after F-fluorodeoxyglucose (285 ± 23 MBq) injection, and followed by a 15-min head-moving PET scan with the developed Kinect based motion-tracking system. First, selecting a motion-less period of the head-moving PET scan provided a reference PET image. Second, CT images separately obtained on the same day were registered to the reference PET image, and create a 3D face-shape model, then, to which Kinect-based 3D face-shape model matched. This matching parameter was used for spatial calibration between the Kinect and the PET system. This calibration parameter and the motion-tracking of the 3D face shape by Kinect comprised our motion correction method. The head-moving PET with motion correction was compared with the head-fixed PET images visually and by standard uptake value ratios (SUVRs) in the seven volume-of-interest regions. To confirm the spatial calibration accuracy, a test-retest experiment was performed by repeating the head-moving PET with motion correction twice where the volunteer's pose and the sensor's position were different.
RESULTS
No difference was identified visually and statistically in SUVRs between the head-moving PET images with motion correction and the head-fixed PET images. One of the small nuclei, the inferior colliculus, was identified in the head-fixed PET images and in the head-moving PET images with motion correction, but not in those without motion correction. In the test-retest experiment, the SUVRs were well correlated (determinant coefficient, r = 0.995).
CONCLUSION
Our motion correction method provided good accuracy for the volunteer data which suggested it is useable in clinical settings.
Topics: Algorithms; Artifacts; Brain; Fluorodeoxyglucose F18; Humans; Image Processing, Computer-Assisted; Male; Motion; Phantoms, Imaging; Positron-Emission Tomography
PubMed: 35854178
DOI: 10.1007/s12149-022-01774-0 -
JACC. Cardiovascular Imaging Sep 2021This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation...
OBJECTIVES
This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED).
BACKGROUND
Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols.
METHODS
Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED.
RESULTS
Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv.
CONCLUSIONS
Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions.
Topics: Cardiology; Cross-Sectional Studies; Humans; Myocardial Perfusion Imaging; Predictive Value of Tests; Radiation Dosage; Software; Technology; Tomography, Emission-Computed, Single-Photon; Tomography, X-Ray Computed
PubMed: 33454257
DOI: 10.1016/j.jcmg.2020.11.011 -
Journal of Applied Clinical Medical... Jul 2021Electron radiation therapy dose distributions are affected by irregular body surface contours. This study investigates the feasibility of three-dimensional (3D) cameras...
PURPOSE
Electron radiation therapy dose distributions are affected by irregular body surface contours. This study investigates the feasibility of three-dimensional (3D) cameras to substitute for the treatment planning computerized tomography (CT) scan by capturing the body surfaces to be treated for accurate electron beam dosimetry.
METHODS
Dosimetry was compared for six electron beam treatments to the nose, toe, eye, and scalp using full CT scan, CT scan with Hounsfield Unit (HU) overridden to water (mimic 3D camera cases), and flat-phantom techniques. Radiation dose was prescribed to a depth on the central axis per physician's order, and the monitor units (MUs) were calculated. The 3D camera spatial accuracy was evaluated by comparing the 3D surface of a head phantom captured by a 3D camera and that generated with the CT scan in the treatment planning system. A clinical case is presented, and MUs were calculated using the 3D camera body contour with HU overridden to water.
RESULTS
Across six cases the average change in MUs between the full CT and the 3Dwater (CT scan with HU overridden to water) calculations was 1.3% with a standard deviation of 1.0%. The corresponding hotspots had a mean difference of 0.4% and a standard deviation of 1.9%. The 3D camera captured surface of a head phantom was found to have a 0.59 mm standard deviation from the surface derived from the CT scan. In-vivo dose measurements (213 ± 8 cGy) agreed with the 3D-camera planned dose of 209 ± 6 cGy, compared to 192 ± 6 cGy for the flat-phantom calculation (same MUs).
CONCLUSIONS
Electron beam dosimetry is affected by irregular body surfaces. 3D cameras can capture irregular body contours which allow accurate dosimetry of electron beam treatment as an alternative to costly CT scans with no extra exposure to radiation. Tools and workflow for clinical implementation are provided.
Topics: Electrons; Humans; Phantoms, Imaging; Radiometry; Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted; Tomography, X-Ray Computed
PubMed: 34042253
DOI: 10.1002/acm2.13283 -
Physics in Medicine and Biology Nov 2020Compton imaging or Compton camera imaging has been studied well, but its advantages in nuclear medicine and molecular imaging have not been demonstrated yet. Therefore,...
Compton imaging or Compton camera imaging has been studied well, but its advantages in nuclear medicine and molecular imaging have not been demonstrated yet. Therefore, the aim of this work was to compare Compton imaging with positron emission tomography (PET) by using the same imaging platform of whole gamma imaging (WGI). WGI is a concept that combines PET with Compton imaging by inserting a scatterer ring into a PET ring. This concept utilizes diverse types of gamma rays for 3D tomographic imaging. In this paper, we remodeled our previous WGI prototype for small animal imaging, and we developed an image reconstruction method based on a list-mode ordered subset expectation maximization algorithm incorporating detector response function modeling, random correction and normalization (sensitivity correction) for either PET and Compton imaging. To the best of our knowledge, this is the world's first realization of a full-ring Compton imaging system. We selected Zr as an imaging target because a Zr nuclide emits a 909 keV single-gamma ray as well as a positron, and we can directly compare Compton imaging of 909 keV photons with PET, a well-established modality. We measured a cylindrical phantom and a small rod phantom filled with Zr solutions of 10.3 MBq and 10.2 MBq activity, respectively, for 1 h each. The uniform radioactivity distribution of the cylindrical phantom was reconstructed with normalization in both PET and Compton imaging. Coefficients of variation for region-of-interest values were 4.2% for Compton imaging and 3.3% for PET; the difference might be explained by the difference in the detected count number. The small rod phantom experiment showed that the WGI Compton imaging had spatial resolution better than 3.0 mm at the peripheral region although the center region had lower resolution. PET resolved 2.2 mm rods clearly at any location. We measured a mouse for 1 h, 1 d after injection of 9.8 MBq Zr oxalate. The Zr assimilated in the mouse bony structures was clearly depicted, and Compton imaging results agreed well with PET images, especially for the region inside the scatterer ring. In conclusion, we demonstrated the performance of WGI using the developed Compton image reconstruction method. We realized Compton imaging with a quality approaching that of PET, which is supporting a future expectation that Compton imaging outperforms PET.
Topics: Algorithms; Animals; Imaging, Three-Dimensional; Mice; Phantoms, Imaging; Photons; Positron-Emission Tomography
PubMed: 32937613
DOI: 10.1088/1361-6560/abb92e -
Journal of Nuclear Medicine Technology Mar 2023Nuclear medicine (NM) started in Qatar in the mid-1980s with a 1-head γ-camera in Hamad General Hospital. However, Qatar is expanding, and now Hamad Medical Corp. has 2...
Nuclear medicine (NM) started in Qatar in the mid-1980s with a 1-head γ-camera in Hamad General Hospital. However, Qatar is expanding, and now Hamad Medical Corp. has 2 NM departments and 1 PET/CT Center for Diagnosis and Research, with several hybrid SPECT/CT and PET/CT cameras. Furthermore, 2 new NM departments will be established in Qatar in the coming 3 y. Therefore, there is a need to optimize radiation protection in NM imaging and establish diagnostic reference levels (DRLs) for the first time in Qatar. This need is not only for the NM part of the examination but also for the CT part, especially in hybrid SPECT/CT and PET/CT. Data for adult patients were collected from the 3 SPECT/CT machines in the 2 NM facilities and from the 2 PET/CT machines in the PET/CT center. The 75th percentile values (also known as the third quartile) were considered preliminary DRLs and were consistent with the most commonly administered activities. The results for various general NM protocols were described, especially Tc-based radiopharmaceuticals and PET/CT protocols including mainly oncologic applications. The first DRLs for NM imaging in Qatar adults were established. The values agreed with other published DRLs, as was the case, for example, for PET oncology using F-FDG, with DRLs of 258, 230, 370, 400, and 461-710 MBq for Qatar, Kuwait, Korea, the United Kingdom, and the United States, respectively. Similarly, for cardiac stress or rest myocardial perfusion imaging using Tc-methoxyisobutylisonitrile, the DRLs were 926, 976, 1,110, 800, and 945-1,402 MBq for Qatar, Kuwait, Korea, the United Kingdom, and the United States, respectively. The optimization of administered activity that this study will enable for NM procedures in Qatar will be of great value, especially for new departments that adhere to these DRLs.
Topics: Adult; Humans; Positron Emission Tomography Computed Tomography; Nuclear Medicine; Diagnostic Reference Levels; Qatar; Radiopharmaceuticals; Myocardial Perfusion Imaging
PubMed: 36041876
DOI: 10.2967/jnmt.122.264415 -
Advanced Science (Weinheim,... Nov 2022Establishing the biological basis of cognition and its disorders will require high precision spatiotemporal measurements of neural activity. Recently developed...
Establishing the biological basis of cognition and its disorders will require high precision spatiotemporal measurements of neural activity. Recently developed genetically encoded voltage indicators (GEVIs) report both spiking and subthreshold activity of identified neurons. However, maximally capitalizing on the potential of GEVIs will require imaging at millisecond time scales, which remains challenging with standard camera systems. Here, application of single photon avalanche diode (SPAD) sensors is reported to image neural activity at kilohertz frame rates. SPADs are electronic devices that when activated by a single photon cause an avalanche of electrons and a large electric current. An array of SPAD sensors is used to image individual neurons expressing the GEVI Voltron-JF525-HTL. It is shown that subthreshold and spiking activity can be resolved with shot noise limited signals at frame rates of up to 10 kHz. SPAD imaging is able to reveal millisecond scale synchronization of neural activity in an ex vivo seizure model. SPAD sensors may have widespread applications for investigation of millisecond timescale neural dynamics.
Topics: Photons; Neurons; Diagnostic Imaging; Electronics
PubMed: 36068166
DOI: 10.1002/advs.202203018