Wiener Klinische Wochenschrift Aug 2021Valve degeneration after surgical tricuspid valve replacement or repair is frequent and may require repeat replacement/repair. For high-risk patients, transcatheter... (Review)
Review
Valve degeneration after surgical tricuspid valve replacement or repair is frequent and may require repeat replacement/repair. For high-risk patients, transcatheter valve-in-valve and valve-in-ring procedures have emerged as valuable treatment alternatives. Preprocedural transthoracic echocardiography is the method of choice to detect malfunction of the prosthesis including degenerative stenosis and/or regurgitation requiring reintervention. Subsequently, computed tomography is helpful for detailed anatomical analysis and periprocedural planning. Device selection and sizing depend on the size and structural details of the implanted ring or prosthesis. The procedure is mainly guided by fluoroscopy; however, transesophageal echocardiography provides complementary guidance during device implantation. Preferred access route is the right femoral vein but in cases of more horizontal implants a jugular approach might be feasible. Suitable transcatheter valves are the Edwards Sapien 3 and the Medtronic Melody valves. Differences in surgical prostheses or annuloplasty implants are important for device selection, height consideration and additional ballooning prior to or after implantation. Transesophageal echocardiography postimplantation is convenient for the assessment of transvalvular gradients or paravalvular leaks.
Topics: Aortic Valve; Cardiac Catheterization; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Prosthesis Design; Treatment Outcome; Tricuspid Valve
PubMed: 33791869
DOI: 10.1007/s00508-021-01842-x -
Current Cardiology Reports Oct 2022Paravalvular leak (PVL) is a relatively uncommon complication associated with prosthetic valve implantation. PVL can occasionally lead to serious adverse consequences... (Review)
Review
PURPOSE OF REVIEW
Paravalvular leak (PVL) is a relatively uncommon complication associated with prosthetic valve implantation. PVL can occasionally lead to serious adverse consequences such as congestive heart failure, infective endocarditis, and hemolytic anemia. Surgical re-operation carries a high mortality risk.
RECENT FINDINGS
Transcatheter closure therapy provides a viable alternative for the treatment of this disorder with reasonable procedural and clinical success. The recent advent of hybrid imaging modalities has increased procedural success. This article summarizes the pathophysiology, clinical characteristics, and treatment modalities surroundings prosthetic paravalvular leak.
Topics: Cardiac Catheterization; Heart Failure; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Prosthesis Failure; Reoperation; Treatment Outcome
PubMed: 36152141
DOI: 10.1007/s11886-022-01744-y -
Current Opinion in Cardiology Mar 2020A thorough understanding of the modes of bioprosthetic valve failure is critical as clinicians will be facing an increasing number of patients presenting with failed... (Review)
Review
PURPOSE OF REVIEW
A thorough understanding of the modes of bioprosthetic valve failure is critical as clinicians will be facing an increasing number of patients presenting with failed bioprostheses in coming years. The purpose of this article is to review modes of bioprosthestic valve degeneration, their management, and identify gaps for future research.
RECENT FINDINGS
Guidelines recommend monitoring hemodynamic performance of prosthetic valves using serial echocardiograms to determine valve function and presence of valve degeneration. Modes of bioprosthetic valve failure may be categorized as structural degeneration (calcification, tears, fibrosis, flail), nonstructural degeneration (pannus), thrombosis, and endocarditis. Calcification is the most common form of structural valve degeneration. Predictors of bioprosthetic valve failure include valves implanted in the mitral position, younger age, and type of valve (porcine versus bovine pericardial). Failed bioprosthetic valves are managed with either redo surgical replacement or transcatheter valve-in-valve implantation.
SUMMARY
Several modes of bioprosthetic valve failure exist, which vary based on patient, implant position, and valve characteristics. Further research is required to characterize factors associated with early failure to delay structural valve degeneration and improve patient prognosis.
Topics: Animals; Aortic Valve; Bioprosthesis; Calcinosis; Cattle; Endocarditis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Prosthesis Failure; Swine
PubMed: 31972604
DOI: 10.1097/HCO.0000000000000711 -
Surgery Today Apr 2022Recently developed prosthetic valves are reliable and essential for the treatment of valvular heart disease. The mechanical valve evolved remarkably following the... (Review)
Review
Recently developed prosthetic valves are reliable and essential for the treatment of valvular heart disease. The mechanical valve evolved remarkably following the introduction of pyrolite carbon material, which enabled the creation of a bileaflet form incorporated with a pivot mechanism. The improved durability of the biological valve is attributed mainly to the development of a tissue fixation process and anti-calcification treatments. However, optimal antithrombogenicity and durability have not yet been achieved for either prosthetic valve type. To select the most suitable prosthetic valve for each individual patient from among the many clinically available prosthetic valves, it is necessary to have a thorough understanding of the characteristics of each valve.
Topics: Heart Valve Diseases; Heart Valve Prosthesis; Heart Valves; Humans; Japan; Prosthesis Design
PubMed: 34435247
DOI: 10.1007/s00595-021-02361-y -
The American Journal of Cardiology Jul 2021The long-term outcome of mechanical aortic and mitral prosthetic valve (A-PV, M-PV) dysfunction (PVD) remains a serious complication associated with high morbidity and...
The long-term outcome of mechanical aortic and mitral prosthetic valve (A-PV, M-PV) dysfunction (PVD) remains a serious complication associated with high morbidity and mortality. We sought to evaluate the incremental diagnostic value of combined transthoracic echocardiography (TTE) and fluoroscopy (F) in patients with suspected PVD. A total of 354 patients (178 A-PV, 176 M-PV) were imaged by TTE and F within 5 days of hospital admission. PVD was confirmed by transesophageal echocardiography, computed tomography, effective thrombolysis, or surgical inspection. PVD was confirmed in 101 patients (57%) with M-PV and 99 (55%) with A-PV. Regardless of the mechanism of PVD, TTE shows good sensitivity and specificity, with accuracy of 80% for M-PV and 91% for A-PV. F shows high specificity, but low sensitivity with accuracy of 68% for M-PV and 78% for A-PV. The integration of TTE + F significantly improved accuracy both for M-PV (83%) and A-PV (96%). At ROC analysis, the combined model of TTE + F showed the highest area under the curve for the detection of PVD compared with TTE and F alone (p < 0.001). In conclusion, in patients with a clinical suspicion of PVD, the combined model of TTE + F offers incremental value over TTE or F alone. This multimodality imaging approach overcomes limitations of TTE or F alone and provides prompt identification of patients who may require further imaging assessment and/or closer follow up.
Topics: Aged; Echocardiography; Female; Fluoroscopy; Heart Valve Prosthesis; Humans; Italy; Male; Middle Aged; Prosthesis Failure; Retrospective Studies; Sensitivity and Specificity; Thrombolytic Therapy; Tomography, X-Ray Computed
PubMed: 34020771
DOI: 10.1016/j.amjcard.2021.03.055 -
Annals of Cardiac Anaesthesia 2022Worldwide, about 13% of the 200,000 annual recipients of prosthetic heart valves (PHV) present for various surgical procedures. Also, more and more females are opting... (Review)
Review
Worldwide, about 13% of the 200,000 annual recipients of prosthetic heart valves (PHV) present for various surgical procedures. Also, more and more females are opting for pregnancies after having PHV. All patients with PHV present unique challenges for the anesthesiologists, surgeons and obstetricians (in case of deliveries). They have to deal with the perioperative management of anticoagulation and a host of other issues involved. We reviewed the English language medical literature relevant to the different aspects of perioperative management of patients with PHV, particularly the guidelines of reputed societies that appeared in the last 20 years. Regression of cardiac pathophysiology following valve replacement is variable both in extent and timeline. The extent to which reverse remodeling occurs depends on the perioperative status of the heart. We discussed the perioperative assessment of patients with PHV, including focused history and relevant investigations with the inferences drawn. We examined the need for prophylaxis against infective endocarditis and management of anticoagulation in such patients in the perioperative period and the guidelines of reputed societies. We also reviewed the conduct of anesthesia, including general and regional anesthesia (neuraxial and peripheral nerve/plexus blocks) in such patients. Finally, we discussed the management of delivery in this group of high-risk patients. From the discussion of different aspects of perioperative management of patients with PHV, we hope to guide in formulating the comprehensive plan of management of safe anesthesia in such patients.
Topics: Anticoagulants; Endocarditis; Female; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Heart Valves; Humans; Pregnancy
PubMed: 35799551
DOI: 10.4103/aca.aca_109_21 -
Internal Medicine (Tokyo, Japan) Feb 2024
Topics: Humans; Candida; Endocarditis, Bacterial; Heart Valve Prosthesis; Endocarditis; Candidiasis; Antifungal Agents
PubMed: 37316271
DOI: 10.2169/internalmedicine.1987-23 -
Clinical Imaging Aug 2023Prosthetic heart valve (PHV) dysfunction is a serious complication. Echocardiography remains the first-line imaging investigation to assess PHV dysfunction. However, the...
BACKGROUND
Prosthetic heart valve (PHV) dysfunction is a serious complication. Echocardiography remains the first-line imaging investigation to assess PHV dysfunction. However, the role of Computed Tomography (CT) scanning in this type of case has not been thoroughly studied yet. The objective of our study was to determine if cardiac Computed Tomography (CT) had a potentially complementary role to play alongside echocardiography in diagnosing the mechanism of prosthetic valve dysfunction.
METHODS AND RESULTS
This prospective cohort study was conducted on 54 patients with suspected PHV dysfunction. All patients underwent routine diagnosis work-up (transthoracic and transesophageal echocardiography) and additional cardiac CT. Cardiac CT showed findings that were not detected by echocardiography in seven patients (12%) namely aortic pannus (5) and pseudoaneurysm (2). An underlying thrombus was detected by echocardiography and missed by cardiac CT in 15 patients (27%). However, in these thrombotic cases, cardiac CT contributed to the functional evaluation of leaflets.
CONCLUSION
This study demonstrates that an integrated approach including transthoracic, transesophageal echocardiography and computed tomography is useful in patients with suspected PHV dysfunction. While computed tomography is more accurate in the diagnosis of pannus formation and periannular complications, echocardiography is superior at detecting thrombus.
Topics: Humans; Heart Valve Prosthesis; Prospective Studies; Tomography; Echocardiography, Transesophageal; Thrombosis; Heart Valves; Prosthesis Failure
PubMed: 37146521
DOI: 10.1016/j.clinimag.2023.02.011 -
Journal of Cardiac Surgery Jul 2021Although aortic valve replacement (AVR) has been the standard of treatment for severe aortic stenosis, a small aortic annulus (SAA) poses significant challenges.... (Review)
Review
BACKGROUND
Although aortic valve replacement (AVR) has been the standard of treatment for severe aortic stenosis, a small aortic annulus (SAA) poses significant challenges. Improvements in valve designs and evolution in surgical techniques have led to improved outcomes, however, the ideal prosthetic valve remains elusive.
METHODS
We performed a comprehensive literature review to discuss the surgical management of aortic stenosis, with a special focus on patients with SAA.
RESULTS
Stentless valves and root replacement techniques have been shown to overcome the hemodynamic challenges associated with conventional stented bioprostheses, but are technically challenging and require longer cross-clamp times. Sutureless and rapid deployment valves mitigate the long operative time while maintaining the hemodynamic advantages. The use of transcatheter AVR has emerged as another reasonable alternative and has shown promise among patients with SAA, however, long-term outcomes are awaited.
CONCLUSION
There is no consensus regarding the type of valve prosthesis or replacement technique among patients with SAA. Consideration of patient comorbidities and valvular anatomy is paramount in planning the optimal strategy for AVR. Further long-term clinical trials are necessary to assess outcomes and achieve progress toward the development of the ideal prosthesis.
Topics: Aortic Valve; Aortic Valve Stenosis; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Prosthesis Design; Treatment Outcome
PubMed: 33821514
DOI: 10.1111/jocs.15555 -
Journal of Cardiac Surgery Dec 2022The hemodynamics of most prosthetic valves are often inferior to that of the normal native valve, and a significant proportion of patients undergoing surgical (SAVR) or... (Review)
Review
BACKGROUND
The hemodynamics of most prosthetic valves are often inferior to that of the normal native valve, and a significant proportion of patients undergoing surgical (SAVR) or transcatheter aortic valve replacement (TAVR) have high residual transaortic pressure gradients due to prosthesis-patient mismatch (PPM). As the experience with TAVR has increased and long-term outcomes are reported, a close look at the PPM literature is required in light of new evidence.
METHODS
For this review, we searched the Embase, Medline, and Cochrane databases from 2000 to 2022. Articles reporting PPM as an outcome following aortic valve replacements were identified and reviewed.
RESULTS
The impact of PPM on clinical outcomes in aortic valve replacement has not been clear as multiple studies failed to report PPM incidence. However, the PPM outcomes after SAVR vary more widely than after TAVR, ranging from 8% to 80% in SAVR and from 24% to 35% in TAVR. Incidence of severe PPM following redo SAVR ranges from 2% to 9% and following valve-in-valve TAVR is from 14% to 33%, however, while PPM is higher in valve-in-valve TAVR, patients had better survival rates.
CONCLUSIONS
The gap between valve performance and clinical outcomes in SAVR and TAVR could be reduced by carefully selecting patients for either treatment option. Understanding predictors of PPM can add to the safety, effectiveness, and increased survival benefit of both SAVR and TAVR.
Topics: Humans; Transcatheter Aortic Valve Replacement; Heart Valve Prosthesis Implantation; Aortic Valve Stenosis; Treatment Outcome; Aortic Valve; Heart Valve Prosthesis; Risk Factors
PubMed: 36378858
DOI: 10.1111/jocs.17217