Clinical Infectious Diseases : An... Dec 2023Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is associated with high mortality and surgery is rarely performed. Thus, to inform on...
BACKGROUND
Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is associated with high mortality and surgery is rarely performed. Thus, to inform on preventive measures and treatment strategies, we investigated patient characteristics and microbiology of IE after TAVI.
METHODS
Using Danish nationwide registries, we identified patients with IE after TAVI, IE after non-TAVI prosthetic valve (nTPV), and native valve IE. Patient characteristics; overall, early (≤12 m), and late IE (>12 m) microbiology; and unadjusted and adjusted mortality were compared.
RESULTS
We identified 273, 1022, and 5376 cases of IE after TAVI, IE after nTPV, and native valve IE. Age and frailty were highest among TAVI IE (4.8%; median age: 82 y; 61.9% frail). Enterococcus spp. were common for IE after TAVI (27.1%) and IE after nTPV (21.2%) compared with native valve IE (11.4%). Blood culture-negative IE was rare in IE after TAVI (5.5%) compared with IE after nTPV (15.2%) and native valve IE (13.5%). The unadjusted 90-day mortality was comparable, but the 5-year mortality was highest for IE after TAVI (75.2% vs 57.2% vs 53.6%). In Cox models adjusted for patient characteristics and bacterial etiology for 1-90 days and 91-365 days, there was no significant difference in mortality rates.
CONCLUSIONS
Patients with IE after TAVI are older and frailer, enterococci and streptococci are often the etiologic agents, and are rarely blood culture negative compared with other IE patients. Future studies regarding antibiotic prophylaxis strategies covering enterococci should be considered in this setting.
Topics: Humans; Aged, 80 and over; Transcatheter Aortic Valve Replacement; Prosthesis-Related Infections; Endocarditis, Bacterial; Endocarditis; Enterococcus; Risk Factors; Treatment Outcome; Heart Valve Prosthesis
PubMed: 37470442
DOI: 10.1093/cid/ciad431 -
Current Cardiology Reviews 2023Prosthetic valve endocarditis can be difficult to diagnose and cause significant morbidity and mortality, especially when no culture data are available to guide therapy....
BACKGROUND
Prosthetic valve endocarditis can be difficult to diagnose and cause significant morbidity and mortality, especially when no culture data are available to guide therapy. Transthoracic and transesophageal echocardiograms, the studies of choice for initial endocarditis evaluation, can be less reliable due to artifact and post-surgical changes. Some less common forms of endocarditis may be difficult to culture and, due to their fastidious nature, may delay the identification of causative organisms. Given the lack of directed antimicrobial treatment, culturenegative prosthetic valve endocarditis is specifically difficult. A wide differential diagnosis is critical to make a timely diagnosis and initiate treatment.
CASE PRESENTATION
We present a case of a patient presenting with dyspnea which was found to have culture-negative endocarditis requiring mitral and aortic valve replacement that ultimately was complicated with culture-negative prosthetic valve endocarditis. Identifying a culprit organism made appropriate and timely antimicrobial treatment difficult, ultimately resulting in the patient dying from endocarditis complications.
CONCLUSION
A high index of suspicion is needed when managing infective endocarditis, especially when prosthetic valves are involved. Diagnostic accuracy of cultures and echocardiography may be reduced when dealing with prosthetic valve endocarditis; thus, alternative methods of diagnosis may be required to make a timely diagnosis of causative organisms.
Topics: Humans; Endocarditis, Bacterial; Heart Valve Prosthesis; Aortic Valve; Echocardiography; Anti-Infective Agents
PubMed: 37055889
DOI: 10.2174/1573403X19666230411151214 -
Nederlands Tijdschrift Voor Geneeskunde Feb 2022We report on three patients with infective endocarditis, which differ greatly in clinical manifestations. Infective endocarditis (IE) is defined by, a mostly bacterial,...
We report on three patients with infective endocarditis, which differ greatly in clinical manifestations. Infective endocarditis (IE) is defined by, a mostly bacterial, infection of a native or prosthetic heart valve, the endocardial surface or a cardiac device. It is a rare condition, but it's incidence is increasing because of an increased incidence of elderly patients with chronic disease and cardiac devices. IE is heterogeneous in aetiology, clinical manifestations, and course. It can involve almost any organ system. The presentation often remains subtle and varies with nonspecific symptoms ranging from a mild infection to septic shock and multiorgan failure. IE remains a highly mortal disease, since the diagnosis is missed often. A thorough anamnesis and physical examination can be helpful. Blood cultures prior to antibiotics and echocardiography are key diagnostic steps if there's a clinical suspicion of IE.
Topics: Aged; Anti-Bacterial Agents; Echocardiography; Endocarditis; Endocarditis, Bacterial; Heart Valve Prosthesis; Humans
PubMed: 35129893
DOI: No ID Found -
The Canadian Journal of Cardiology Jul 2021Surgical replacement remains the primary option to treat the rapidly growing number of patients with severe valvular heart disease. Although current valve... (Review)
Review
Surgical replacement remains the primary option to treat the rapidly growing number of patients with severe valvular heart disease. Although current valve replacements-mechanical, bioprosthetic, and cryopreserved homograft valves-enhance survival and quality of life for many patients, the ideal prosthetic heart valve that is abundantly available, immunocompatible, and capable of growth, self-repair, and life-long performance has yet to be developed. These features are essential for pediatric patients with congenital defects, children and young adult patients with rheumatic fever, and active adult patients with valve disease. Heart valve tissue engineering promises to address these needs by providing living valve replacements that function similarly to their native counterparts. This is best evidenced by the long-term clinical success of decellularised pulmonary and aortic homografts, but the supply of homografts cannot meet the demand for replacement valves. A more abundant and consistent source of replacement valves may come from cellularised valves grown in vitro or acellular off-the-shelf biomaterial/tissue constructs that recellularise in situ, but neither tissue engineering approach has yet achieved long-term success in preclinical testing. Beyond the technical challenges, heart valve tissue engineering faces logistical, economic, and regulatory challenges. In this review, we summarise recent progress in heart valve tissue engineering, highlight important outcomes from preclinical and clinical testing, and discuss challenges and future directions toward clinical translation.
Topics: Biocompatible Materials; Heart Valve Diseases; Heart Valve Prosthesis; Humans; Long Term Adverse Effects; Materials Testing; Tissue Engineering; Translational Research, Biomedical
PubMed: 33839245
DOI: 10.1016/j.cjca.2021.03.022 -
Journal of Thrombosis and Thrombolysis Apr 2023Since the beginning of the SARS-CoV-2 (COVID-19) pandemic, correlation of venous thromboembolism (VTE) and COVID-19 infection has been well established. Increased... (Review)
Review
Since the beginning of the SARS-CoV-2 (COVID-19) pandemic, correlation of venous thromboembolism (VTE) and COVID-19 infection has been well established. Increased inflammatory response in the setting of COVID-19 infection is associated with VTE and hypercoagulability. Venous and arterial thrombotic events in COVID-19 infection have been well documented; however, few cases have been reported involving cardiac valve prostheses. In this review, we present a total of eight cases involving COVID-19-related prosthetic valve thrombosis (PVT), as identified in a systematic review. These eight cases describe valve position (mitral versus aortic) and prosthesis type (bioprosthetic versus mechanical), and all cases demonstrate incidents of PVT associated with simultaneous or recent COVID-19 infection. None of these eight cases display obvious non-adherence to anticoagulation; five of the cases occurred greater than three years after the most recent valve replacement. Our review offers insights into PVT in COVID-19 infected patients including an indication for increased monitoring in the peri-infectious period. We explore valve thrombosis as a mechanism for prosthetic valve failure. We describe potential differences in antithrombotic strategies that may offer added antithrombotic protection during COVID-19 infection. With the growing population of valve replacement patients and recurring COVID-19 infection surges, it is imperative to explore relationships between COVID-19 and PVT.
Topics: Humans; Fibrinolytic Agents; Venous Thromboembolism; COVID-19; SARS-CoV-2; Heart Valve Diseases; Heart Valve Prosthesis; Thrombosis; Aortic Valve
PubMed: 36528721
DOI: 10.1007/s11239-022-02746-x -
JACC. Cardiovascular Imaging Jan 2021Catheter-based interventions to improve mitral valve function are dependent on anatomic and functional information provided by noninvasive imaging to plan, perform, and... (Review)
Review
Catheter-based interventions to improve mitral valve function are dependent on anatomic and functional information provided by noninvasive imaging to plan, perform, and evaluate each intervention. In this review we highlight the importance of imaging guidance for catheter-based interventions on prosthetic mitral valves, surgical rings, and native valve annular calcification. Both repair and replacement procedures are discussed. We review the general features common to this collection of procedures and discuss specific imaging issues and concerns for each procedure. Figures and intraprocedural videos emphasize central messages using case examples.
Topics: Cardiac Catheterization; Heart Valve Diseases; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Mitral Valve; Predictive Value of Tests; Treatment Outcome
PubMed: 32771581
DOI: 10.1016/j.jcmg.2019.10.027 -
Journal of the American Heart... May 2023Background Guidelines for choice of prosthetic heart valve in people of reproductive age are not well established. Although biologic heart valves (BHVs) have risk of...
Background Guidelines for choice of prosthetic heart valve in people of reproductive age are not well established. Although biologic heart valves (BHVs) have risk of deterioration, mechanical heart valves (MHVs) require lifelong anticoagulation. This study aimed to characterize the association of prosthetic valve type with maternal and fetal outcomes in pregnant patients. Methods and Results Using the 2008 to 2019 National Inpatient Sample, we identified all adult patients hospitalized for delivery with prior heart valve implantation. Multivariable regressions were used to analyze the primary outcome, major adverse cardiovascular events, and secondary outcomes, including maternal and fetal complications, length of stay, and costs. Among 39 871 862 birth hospitalizations, 4152 had MHVs and 874 had BHVs. Age, comorbidities, and cesarean birth rates were similar between patients with MHVs and BHVs. The presence of a prosthetic valve was associated with over 22-fold increase in likelihood of major adverse cardiovascular events (MHV: adjusted odds ratio, 22.1 [95% CI, 17.3-28.2]; BHV: adjusted odds ratio, 22.5 [95% CI, 13.9-36.5]) as well as increased duration of stay and hospitalization costs. However, patients with MHVs and BHVs had no significant difference in the odds of any maternal outcome, including major adverse cardiovascular events, hypertensive disease of pregnancy, and ante/postpartum hemorrhage. Similarly, fetal complications were more likely in patients with valve prostheses, including a 4-fold increase in odds of stillbirth, but remained comparable between MHVs and BHVs. Conclusions Patients hospitalized for delivery with prior valve replacement carry substantial risk of adverse maternal and fetal events, regardless of valve type. Our findings reveal comparable outcomes between MHVs and BHVs.
Topics: Pregnancy; Adult; Female; Humans; Heart Valves; Heart Valve Prosthesis; Prenatal Care; Parturition; Cardiovascular Diseases; Bioprosthesis
PubMed: 37183876
DOI: 10.1161/JAHA.122.028653 -
Journal of the American College of... Apr 2024During the past 6 decades, there have been numerous changes in prosthetic valve endocarditis (PVE), currently affecting an older population and increasing in incidence... (Review)
Review
During the past 6 decades, there have been numerous changes in prosthetic valve endocarditis (PVE), currently affecting an older population and increasing in incidence in patients with transcatheter-implanted valves. Significant microbiologic (molecular biology) and imaging diagnostic (fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography) advances have been incorporated into the 2023 Duke-International Society for Cardiovascular Infectious Diseases infective endocarditis diagnostic criteria, thus increasing the diagnostic sensitivity for PVE without sacrificing specificity in validation studies. PVE is a life-threatening disease requiring management by multidisciplinary endocarditis teams in cardiac centers to improve outcomes. Novel surgical options are now available, and an increasing set of patients may avoid surgical intervention despite indication. Selected patients may complete parenteral or oral antimicrobial treatment at home. Finally, patients with prosthetic valves implanted surgically or by the transcatheter approach are candidates for antibiotic prophylaxis before invasive dental procedures.
Topics: Humans; Endocarditis, Bacterial; Heart Valve Prosthesis; Prosthesis-Related Infections; Endocarditis; Positron Emission Tomography Computed Tomography
PubMed: 38599718
DOI: 10.1016/j.jacc.2024.01.037 -
Medicina (Kaunas, Lithuania) Nov 2022Developing a prosthetic heart valve that combines the advantageous hemodynamic properties of its biological counterpart with the longevity of mechanical prostheses has...
Developing a prosthetic heart valve that combines the advantageous hemodynamic properties of its biological counterpart with the longevity of mechanical prostheses has been a major challenge for heart valve development. Anatomically inspired artificial polymeric heart valves have the potential to combine these beneficial properties, and innovations in 3D printing have given us the opportunity to rapidly test silicone prototypes of new designs to further the understanding of biophysical properties of artificial heart valves. TRISKELION is a promising prototype that we have developed, tested, and further improved in our institution. Materials and STL files of our prototypes were designed with FreeCad 0.19.2 and 3D printed with an Agilista 3200W (Keyence, Osaka, Japan) using silicones of Shore hardness 35 or 65. Depending on the valve type, the support structures were printed in AR-M2 plastics. The prototypes were then tested using a hemodynamic pulse duplicator (HKP 2.0) simulating an aortic valve cycle at 70 bpm with 70 mL stroke volume (cardiac output 4.9 L/min). Valve opening cycles were visualized with a high-speed camera (Phantom Miro C320). The resulting values led to further improvements of the prototype (TRISKELION) and were compared to a standard bioprosthesis (Edwards Perimount 23 mm) and a mechanical valve (Bileaflet valve, St. Jude Medical). : We improved the silicone prototype with currently used biological and mechanical valves measured in our setup as benchmarks. The regurgitation fractions were 22.26% ± 4.34% (TRISKELION) compared to 8.55% ± 0.22% (biological) and 13.23% ± 0.79% (mechanical). The mean systolic pressure gradient was 9.93 ± 3.22 mmHg (TRISKELION), 8.18 ± 0.65 mmHg (biological), and 10.15 ± 0.16 mmHg (mechanical). The cardiac output per minute was at 3.80 ± 0.21 L/min (TRISKELION), 4.46 ± 0.01 L/min (biological), and 4.21 ± 0.05 L/min (mechanical). The development of a heart valve with a central structure proves to be a promising concept. It offers another principle to address the problem of longevity in currently used heart valves. Using 3D printing to develop new prototypes provides a fast, effective, and accurate way to deepen understanding of its physical properties and requirements. This opens the door for translating and combining results into modern prototypes using highly biocompatible polymers, internal structures, and advanced valve layouts.
Topics: Humans; Heart Valves; Printing, Three-Dimensional; Polymers; Heart Valve Prosthesis; Silicones
PubMed: 36422234
DOI: 10.3390/medicina58111695 -
European Heart Journal. Cardiovascular... Aug 2022Diagnosis of prosthetic valve endocarditis (PVE) by positron emission computed tomography angiography (PET/CTA) is based on visual and quantitative morpho-metabolic...
AIMS
Diagnosis of prosthetic valve endocarditis (PVE) by positron emission computed tomography angiography (PET/CTA) is based on visual and quantitative morpho-metabolic features. However, the fluorodeoxyglucose (FDG) uptake pattern can be sometimes visually unclear and susceptible to subjectivity. This study aimed to validate a new parameter, the valve uptake index [VUI, maximum standardized uptake value (SUVmax)-mean standardized uptake value (SUVmean)/SUVmax], designed to provide a more objective indication of the distribution of metabolic activity. Secondly, to re-evaluate the utility of traditionally used PVE imaging criteria and determine the potential value of adding the VUI in the diagnostic algorithm of PVE.
METHODS AND RESULTS
Retrospective analysis of 122 patients (135 prosthetic valves) admitted for suspicion of endocarditis, with a conclusive diagnosis of definite (N = 57) or rejected (N = 65) PVE, and who had undergone a cardiac PET/CTA scan as part of the diagnostic evaluation. We measured the VUI and recorded the SUVmax, SUVratio, uptake pattern, and the presence of endocarditis-related anatomic lesions. The VUI, SUVmax, and SUVratio values were 0.54 ± 0.1 vs. 0.36 ± 0.08, 7.68 ± 3.07 vs. 3.72 ± 1.11, and 4.28 ± 1.93 vs. 2.16 ± 0.95 in the 'definite' PVE group vs. the 'rejected' group, respectively (mean ± SD; P < 0.001). A cut-off value of VUI > 0.45 showed a sensitivity, specificity, and diagnostic accuracy for PVE of 85%, 88%, and 86.7% and increased diagnostic ability for confirming endocarditis when combined with the standard diagnostic criteria.
CONCLUSIONS
The VUI demonstrated good diagnostic accuracy for PVE, even increasing the diagnostic power of the traditionally used morphometabolic parameters, which also confirmed their own diagnostic performance. More research is needed to assess whether the integration of the VUI into the PVE diagnostic algorithm may clarify doubtful cases and thus improve the diagnostic yield of PET/CTA.
Topics: Endocarditis; Endocarditis, Bacterial; Fluorodeoxyglucose F18; Heart Valve Prosthesis; Humans; Positron Emission Tomography Computed Tomography; Prosthesis-Related Infections; Radiopharmaceuticals; Retrospective Studies
PubMed: 34999818
DOI: 10.1093/ehjci/jeab279