Medical Engineering & Physics Oct 2023As an important indicator of human health, heart rate is related to the diagnosis of cardiovascular diseases. In recent years, extracting the heart rate from the mobile...
As an important indicator of human health, heart rate is related to the diagnosis of cardiovascular diseases. In recent years, extracting the heart rate from the mobile phone image has become a research hotspot. However, the illumination intensity of the background, frame rate of the video, and resolution of the image influence heart rate detection accuracy. To overcome these problems, this study proposed a novel heart rate extraction method based on mobile video. Firstly, the mobile phone camera is engaged to record the finger video, the region of interest (ROI) is extracted through the iterative threshold, and the pulse signal is obtained according to the grayscale change of the resolution within the ROI. Then, a low-pass and a high-pass Butterworth filters are exploited to filter out the noise and interframes from the extracted pulse signal. Finally, an improved adaptive peak extraction algorithm is proposed to detect the pulse peaks and the heart rate derived from the difference in pulse peaks. The experimental results show that light intensity, frame rate and resolution all have an influence on the heart rate extraction accuracy, with the most obvious influence of light, the average accuracy of the experiment can reach 99.32 % under good lighting conditions, while only 72.23 % under poor lighting conditions. In terms of frame rate, increasing the frame rate from 30 fps to 60 fps, the accuracy is improved by 0.9 %. For the resolution, increasing the resolution from 1080 p to 2160 p, the accuracy is improved by 1.12 %. While comparing the proposed method with existing methods, the proposed method has a higher accuracy rate, which has important practical value and application prospects in telemedicine and daily monitoring.
Topics: Humans; Heart Rate; Cell Phone; Fingers; Algorithms; Upper Extremity
PubMed: 37838408
DOI: 10.1016/j.medengphy.2023.104051 -
Annual International Conference of the... Jul 2022Pulse rate variability (PRV) has been proposed as a surrogate for the estimation of Heart Rate Variability (HRV), which is a non-invasive technique used to assess the...
Pulse rate variability (PRV) has been proposed as a surrogate for the estimation of Heart Rate Variability (HRV), which is a non-invasive technique used to assess the cardiac autonomic activity. However, both physiological and technical factors may affect the relationship between HRV and PRV, and there are no standards for the analysis of PRV from photoplethysmographic (PPG) signals. The aim of this study was to determine the best outlier management strategies for PRV analysis. 117 PPG signals with randomly generated PRV information were simulated using Gaussian signals. From these, interbeat intervals were detected and different outlier detection and correction techniques were applied. Time and frequency-domain and non-linear PRV indices were extracted and compared with respect to the gold standard values obtained from the simulated PRV information. The results show that, in good quality PPG signals, there is no need to apply any outlier management technique for the extraction of PRV information. Clinical relevance- Establishing guidelines for PRV mea-surement can lead to more reliable and comparable results, as well as to the increase in the use of this variable for the diagnosis and monitoring of cardiovascular and autonomic conditions.
Topics: Autonomic Nervous System; Heart; Heart Rate; Normal Distribution; Photoplethysmography
PubMed: 36086146
DOI: 10.1109/EMBC48229.2022.9871942 -
Computers in Biology and Medicine Jun 2020A non-invasive yet inexpensive method for heart rate (HR) monitoring is of great importance in many real-world applications including healthcare, psychology...
A non-invasive yet inexpensive method for heart rate (HR) monitoring is of great importance in many real-world applications including healthcare, psychology understanding, affective computing and biometrics. Face videos are currently utilized for such HR monitoring, but unfortunately this can lead to errors due to the noise introduced by facial expressions, out-of-plane movements, camera parameters (like focus change) and environmental factors. We alleviate these issues by proposing a novel face video based HR monitoring method MOMBAT, that is, MOnitoring using Modeling and BAyesian Tracking. We utilize out-of-plane face movements to define a novel quality estimation mechanism. Subsequently, we introduce a Fourier basis based modeling to reconstruct the cardiovascular pulse signal at the locations containing the poor quality, that is, the locations affected by out-of-plane face movements. Furthermore, we design a Bayesian decision theory based HR tracking mechanism to rectify the spurious HR estimates. Experimental results reveal that our proposed method, MOMBAT outperforms state-of-the-art HR monitoring methods and performs HR monitoring with an average absolute error of 1.329 beats per minute and the Pearson correlation between estimated and actual heart rate is 0.9746. Moreover, it demonstrates that HR monitoring is significantly improved by incorporating the pulse modeling and HR tracking.
Topics: Algorithms; Bayes Theorem; Face; Heart Rate; Movement; Photoplethysmography; Signal Processing, Computer-Assisted
PubMed: 32568683
DOI: 10.1016/j.compbiomed.2020.103813 -
Annual International Conference of the... Jul 2020Heart rate variability (HRV) is a noninvasive marker of cardiac autonomic activity and has been used in different circumstances to assess the autonomic responses of the...
Heart rate variability (HRV) is a noninvasive marker of cardiac autonomic activity and has been used in different circumstances to assess the autonomic responses of the body. Pulse rate variability (PRV), a similar variable obtained from pulse waves, has been used in recent years as a valid surrogate of HRV. However, the effect that localized changes in autonomic activity have in the relationship between HRV and PRV has not been entirely understood. In this study, a whole-body cold exposure protocol was performed to generate localized changes in autonomic activity, and HRV and PRV from different body sites were obtained. PRV measured from the earlobe and the finger was shown to differ from HRV, and the correlation between these variables was affected by the cold. Also, it was found that PRV from the finger was more affected by cold exposure than PRV from the earlobe. In conclusion, PRV is affected differently to HRV when localized changes in autonomic activity occur. Hence, PRV should not be considered as a valid surrogate of HRV under certain circumstances.Clinical Relevance- This indicates that pulse rate variability is affected differently to heart rate variability when autonomic activity is modified and suggests that pulse rate variability is not always a valid surrogate of heart rate variability.
Topics: Autonomic Nervous System; Electrocardiography; Fingers; Heart Rate; Photoplethysmography
PubMed: 33018543
DOI: 10.1109/EMBC44109.2020.9175856 -
Sensors (Basel, Switzerland) Jul 2023Not long ago, hearables paved the way for biosensing, fitness, and healthcare monitoring. Smart earbuds today are not only producing sound but also monitoring vital... (Review)
Review
Not long ago, hearables paved the way for biosensing, fitness, and healthcare monitoring. Smart earbuds today are not only producing sound but also monitoring vital signs. Reliable determination of cardiovascular and pulmonary system information can explore the use of hearables for physiological monitoring. Recent research shows that photoplethysmography (PPG) signals not only contain details on oxygen saturation level (SPO2) but also carry more physiological information including pulse rate, respiration rate, blood pressure, and arterial-related information. The analysis of the PPG signal from the ear has proven to be reliable and accurate in the research setting. (1) Background: The present integrative review explores the existing literature on an in-ear PPG signal and its application. This review aims to identify the current technology and usage of in-ear PPG and existing evidence on in-ear PPG in physiological monitoring. This review also analyzes in-ear (PPG) measurement configuration and principle, waveform characteristics, processing technology, and feature extraction characteristics. (2) Methods: We performed a comprehensive search to discover relevant in-ear PPG articles published until December 2022. The following electronic databases: Institute of Electrical and Electronics Engineers (IEEE), ScienceDirect, Scopus, Web of Science, and PubMed were utilized to conduct the studies addressing the evidence of in-ear PPG in physiological monitoring. (3) Results: Fourteen studies were identified but nine studies were finalized. Eight studies were on different principles and configurations of hearable PPG, and eight studies were on processing technology and feature extraction and its evidence in in-ear physiological monitoring. We also highlighted the limitations and challenges of using in-ear PPG in physiological monitoring. (4) Conclusions: The available evidence has revealed the future of in-ear PPG in physiological monitoring. We have also analyzed the potential limitation and challenges that in-ear PPG will face in processing the signal.
Topics: Photoplethysmography; Monitoring, Physiologic; Blood Pressure; Arteries; Respiratory Rate; Heart Rate; Signal Processing, Computer-Assisted
PubMed: 37514778
DOI: 10.3390/s23146484 -
Journal of Clinical Monitoring and... Oct 2021Feedback indicators can improve chest compression quality during cardiopulmonary resuscitation (CPR). However, the application of feedback indicators in the clinic...
Feedback indicators can improve chest compression quality during cardiopulmonary resuscitation (CPR). However, the application of feedback indicators in the clinic practice is rare. Pulse oximetry has been widely used and reported to correlate spontaneous circulation restoration during CPR. However, it is unclear if pulse oximetry can monitor the quality of chest compression. We hypothesized that pulse rate monitored by pulse oximetry can be used as a feedback indicator of the chest compression rate during CPR in a porcine model of cardiac arrest. Seven domestic male pigs (30-35 kg) were utilized in this study. Eighteen intermittent chest compression periods of 2 min were performed on each animal. Chest compression and pulse oximetry plethysmographic waveforms were recorded simultaneously. Chest compression and pulse rates were calculated based on both waveforms. Compression interruption and synchronous pulse interruption times were also measured. Agreement was analyzed between pulse rates and synchronous chest compression rates, as well as between compression interruption times and synchronous pulse interruption times. A total of 126 compression periods of 2 min were performed on seven animals. Interclass correlation coefficients and Bland-Altman analysis revealed reliable agreement between pulse rates and synchronous chest compression rates. Similarly, compression interruption and synchronous pulse interruption times obtained also showed high agreement. Pulse rate can be used as an alternative indicator of chest compression rate during CPR in a porcine model of cardiac arrest. Pulse interruption time also can be used to reflect compression interruption time precisely in this model.
Topics: Animals; Cardiopulmonary Resuscitation; Feedback; Heart Arrest; Heart Rate; Male; Oximetry; Swine
PubMed: 32780354
DOI: 10.1007/s10877-020-00576-x -
PloS One 2023Heart failure is a chronic progressive disease in which the heart muscle is unable to pump enough blood to meet the body's need. It is a severe health problem around the...
INTRODUCTION
Heart failure is a chronic progressive disease in which the heart muscle is unable to pump enough blood to meet the body's need. It is a severe health problem around the world with high re-hospitalization and death rates. The main aim of this study was to identify the factors associated with longitudinal change of pulse rate and survival time to death of congestive heart failure patients treated at Arba Minch General Hospital.
METHODS
A retrospective study design was undertaken on congestive heart failure patients admitted to the Arba Minch General Hospital from January 2017 to December 2020. Data was collected from a total of 199 patients. After evaluating the longitudinal data with a linear mixed model and the survival time to death data with cox proportional model, Bayesian joint model of both sub models was fitted in R software using JMbayes2 package.
RESULTS
Findings from Bayesian joint model revealed that the estimated value for the association parameter was positive and statistically significant. This indicates that there is significant evidence of an association between the mean longitudinal change of pulse rate and the risk of death. Weight of patients at baseline, gender, chronic kidney disease, left ventricular ejection fraction, New York Heart Association classification, diabetes, tuberculosis, pneumonia and family history were statistically significant factors associated with mean evolution of pulse rate of congestive heart failure patients. Left ventricular ejection fraction, etiology of congestive heart failure, type of congestive heart failure, chronic kidney disease, smoking, family history, alcohol and diabetes were found to be statistically significant factors associated with survival time to death.
CONCLUSION
To reduce the risk level, health professionals should give attention to congestive heart failure patients with high pulse rate, co-morbidities of chronic kidney disease, tuberculosis, diabetic, smoking status, family history, and pneumonia in the study area.
Topics: Humans; Heart Rate; Bayes Theorem; Ethiopia; Hospitals, General; Retrospective Studies; Stroke Volume; Ventricular Function, Left; Heart Failure
PubMed: 36881600
DOI: 10.1371/journal.pone.0282637 -
Annual International Conference of the... Jul 2020Motivated by the need for continuous cardiovascular monitoring, we present a system for performing photoplethysmography sensing at multiple facial locations. As a...
Motivated by the need for continuous cardiovascular monitoring, we present a system for performing photoplethysmography sensing at multiple facial locations. As a proof-of-concept, our system incorporates an optical sensor array into a wearable face mask form factor for application in a surgical hemodynamic monitoring use case. Here we demonstrate that our design can accurately detect pulse timing by validating estimated heart rate against ground truth electrocardiogram recordings. In an experiment across 10 experimental subjects, our system achieves an error standard deviation of 2.84 beats per minute. This system shows promise for performing non-invasive, continuous pulse waveform recording from multiple locations on the face.
Topics: Electrocardiography; Heart Rate; Hemodynamic Monitoring; Monitoring, Physiologic; Photoplethysmography
PubMed: 33018918
DOI: 10.1109/EMBC44109.2020.9176700 -
Journal of Community Health Nursing 2021The purpose of this evidence-based education initiative was to increase A Fib detection in a cardiovascular diseased population in which participants were taught radial...
The purpose of this evidence-based education initiative was to increase A Fib detection in a cardiovascular diseased population in which participants were taught radial pulse palpation and signs/symptoms of A Fib. Participants were evaluated after initial education on performance of radial pulse palpation and teach back of signs/symptoms of the arrhythmia and again at three weeks on adherence to daily self-screening and recall of signs/symptoms of A Fib. Post initial education, 88% of eligible participants learned pulse-palpation and 93% could verbalize at minimum one sign/symptom. After three weeks, 94.7% reported daily self-screening, but only 44.7% could verbalize at minimum one sign/symptom. This indicated that participants were continuing to self-screen, but in need of booster education sessions. Educating individuals on self-screening and signs/symptoms of A Fib is clinically feasible.
Topics: Adult; Aged; Aged, 80 and over; Atrial Fibrillation; Female; Heart Rate; Humans; Male; Middle Aged; Palpation; Patient Education as Topic; Self-Assessment
PubMed: 34148433
DOI: 10.1080/07370016.2021.1932973 -
Investigative Ophthalmology & Visual... Apr 2020To study the effect of changing heart rate on the ocular pulse and the dynamic biomechanical behavior of the optic nerve head (ONH) using a comprehensive mathematical...
PURPOSE
To study the effect of changing heart rate on the ocular pulse and the dynamic biomechanical behavior of the optic nerve head (ONH) using a comprehensive mathematical model.
METHODS
In a finite element model of a healthy eye, a biphasic choroid consisted of a solid phase with connective tissues and a fluid phase with blood, and the lamina cribrosa (LC) was viscoelastic as characterized by a stress-relaxation test. We applied arterial pressures at 18 ocular entry sites (posterior ciliary arteries), and venous pressures at four exit sites (vortex veins). In the model, the heart rate was varied from 60 to 120 bpm (increment: 20 bpm). We assessed the ocular pulse amplitude (OPA), pulse volume, ONH deformations, and the dynamic modulus of the LC at different heart rates.
RESULTS
With an increasing heart rate, the OPA decreased by 0.04 mm Hg for every 10 bpm increase in heart rate. The ocular pulse volume decreased linearly by 0.13 µL for every 10 bpm increase in heart rate. The storage modulus and the loss modulus of the LC increased by 0.014 and 0.04 MPa, respectively, for every 10 bpm increase in heart rate.
CONCLUSIONS
In our model, the OPA, pulse volume, and ONH deformations decreased with an increasing heart rate, whereas the LC became stiffer. The effects of blood pressure/heart rate changes on ONH stiffening may be of interest for glaucoma pathology.
Topics: Animals; Biomechanical Phenomena; Finite Element Analysis; Glaucoma; Heart Rate; Humans; Intraocular Pressure; Models, Biological; Models, Theoretical; Optic Disk; Sensitivity and Specificity; Tonometry, Ocular
PubMed: 32315378
DOI: 10.1167/iovs.61.4.27