Current Hypertension Reports Jan 2020Aortic stiffness (AS) is widely associated with hypertension and considered as a major predictor of coronary heart disease (CHD). AS is measured using carotid-femoral... (Review)
Review
PURPOSE OF REVIEW
Aortic stiffness (AS) is widely associated with hypertension and considered as a major predictor of coronary heart disease (CHD). AS is measured using carotid-femoral pulse wave velocity (PWV), particularly when this parameter is associated with an index involving age, gender, heart rate, and mean blood pressure. The present review focuses on the interest of measurement of PWV and the calculation of individual PWV index for the prediction of CHD, in addition with the use of new statistical nonlinear models enabling results with very high levels of accuracy.
RECENT FINDINGS
PWV index may so constitute a substantial marker of large arteries prediction and damage in CHD and may be also used in cerebrovascular and renal circulations models. PWV index determinations are particularly relevant to consider in angiographic CHD decisions and in the presence of vulnerable plaques with high cardiovascular risk. Due to the variability in symptoms and clinical characteristics of patients, together with some imperfections in results, there is no very simple adequate diagnosis approach enabling to improve the so defined CHD prediction in usual clinical practice. In recent works in relation to "artificial intelligence" and involving "decision tree" models and "artificial neural networks," it has been possible to determine consistent pathways introducing predictive medicine and enabling to obtain efficient algorithm classification models of coronary prediction.
Topics: Coronary Disease; Heart Rate; Humans; Hypertension; Pulse Wave Analysis; Vascular Stiffness
PubMed: 31925555
DOI: 10.1007/s11906-019-1006-z -
Medical & Biological Engineering &... Oct 2023Remote photoplethysmography (rPPG) enables contact-free monitoring of the pulse rate by using a color camera. The fundamental limitation is that motion artifacts and...
Remote photoplethysmography (rPPG) enables contact-free monitoring of the pulse rate by using a color camera. The fundamental limitation is that motion artifacts and changes in ambient light conditions greatly affect the accuracy of pulse-rate monitoring. We propose use of a high-speed camera and a motion suppression algorithm with high computational efficiency. This system incorporates a number of major improvements including reproduction of pulse wave details, high-precision pulse-rate monitoring of moving subjects, and excellent scene scalability. A series of quantization methods were used to evaluate the effect of different frame rates and different algorithms in pulse-rate monitoring of moving subjects. The experimental results show that use of 180-fps video and a Plane-Orthogonal-to-Skin (POS) algorithm can produce high-precision pulse-rate monitoring results with mean absolute error can be less than 5 bpm and the relative accuracy reaching 94.5%. Thus, it has significant potential to improve personal health care and intelligent health monitoring.
Topics: Humans; Heart Rate; Pulse; Skin; Photoplethysmography; Motion; Algorithms; Signal Processing, Computer-Assisted
PubMed: 37474842
DOI: 10.1007/s11517-023-02884-1 -
Sensors (Basel, Switzerland) Dec 2021Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR)...
Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easily corrupted by noise and respiration activity since the heartbeat signal has less power compared with the breathing signal and its harmonics. In this paper, a signal processing technique for a UWB radar system was developed to detect the heart rate and respiration rate. There are four main stages of signal processing: (1) clutter removal to reduce the static random noise from the environment; (2) independent component analysis (ICA) to do dimension reduction and remove noise; (3) using low-pass and high-pass filters to eliminate the out of band noise; (4) modified covariance method for spectrum estimation. Furthermore, higher harmonics of heart rate were used to estimate heart rate and minimize respiration interference. The experiments in this article contain different scenarios including bed angle, body position, as well as interference from the visitor near the bed and away from the bed. The results were compared with the ECG sensor and respiration belt. The average mean absolute error (MAE) of heart rate results is 1.32 for the proposed algorithm.
Topics: Algorithms; Heart Rate; Monitoring, Physiologic; Radar; Respiration; Respiratory Rate; Signal Processing, Computer-Assisted; Vital Signs
PubMed: 35009628
DOI: 10.3390/s22010083 -
Annual International Conference of the... Jul 2023Vital sign monitoring is an invaluable tool for healthcare professionals, both in the hospital and at home. Traditional measurement devices provide accurate readings but...
Vital sign monitoring is an invaluable tool for healthcare professionals, both in the hospital and at home. Traditional measurement devices provide accurate readings but require physical contact with the patient which often is unsuitable, furthermore contact-based devices have been reported to fail by loosing contact due to movement as severe events occur, therefore, a contactless method is necessary.We hypothesize that, in ideal scenarios, it is possible to estimate both SpO and pulse rate using only facial video recorded with a smartphone's front-facing camera. To test this hypothesis, a dataset of 10 healthy subjects performing various breathing patterns while being recorded with a smartphone camera was collected during ideal lighting conditions.Using advanced image and signal processing methods to acquire remote photoplethysmography (rPPG) estimates from a patient's forehead, our proposed method can achieve SpO estimation results with A = 1.34% (accuracy RMS) and MAE ± STD = 1.26 ± 0.68% (mean average error) across a SpO range of 92% to 99% (percentage point SpO) and pulse rate estimation results with A = 3.91 bpm (beats per minute) and MAE ± STD = 3.24±2.11 bpm across a pulse rate range of 60 bpm to 90 bpm. We conclude from these results, that remote vital sign estimation using facial videos recorded entirely with a smartphone camera is possible.
Topics: Humans; Heart Rate; Smartphone; Oxygen Saturation; Face; Signal Processing, Computer-Assisted
PubMed: 38083785
DOI: 10.1109/EMBC40787.2023.10340995 -
Methods (San Diego, Calif.) Oct 2023Heart rate variability (HRV) is an important indicator of autonomic nervous system activity and can be used for the identification of affective states. The development...
Heart rate variability (HRV) is an important indicator of autonomic nervous system activity and can be used for the identification of affective states. The development of remote Photoplethysmography (rPPG) technology has made it possible to measure pulse rate variability (PRV) using a camera without any sensor-skin contact, which is highly correlated to HRV, thus, enabling contactless assessment of emotional states. In this study, we employed ten machine learning techniques to identify emotions using camera-based PRV features. Our experimental results show that the best classification model achieved a coordination correlation coefficient of 0.34 for value recognition and 0.36 for arousal recognition. The rPPG-based measurement has demonstrated promising results in detecting HAHV (high-arousal high-valence) emotions with high accuracy. Furthermore, for emotions with less noticeable variations, such as sadness, the rPPG-based measure outperformed the baseline deep network for facial expression analysis.
Topics: Heart Rate; Emotions; Machine Learning; Skin
PubMed: 37678514
DOI: 10.1016/j.ymeth.2023.08.014 -
Scientific Reports Apr 2022This study presents findings in the terahertz (THz) frequency spectrum for non-contact cardiac sensing applications. Cardiac pulse information is simultaneously...
This study presents findings in the terahertz (THz) frequency spectrum for non-contact cardiac sensing applications. Cardiac pulse information is simultaneously extracted using THz waves based on the established principles in electronics and optics. The first fundamental principle is micro-Doppler motion effect. This motion based method, primarily using coherent phase information from the radar receiver, has been widely exploited in microwave frequency bands and has recently found popularity in millimeter waves (mmWave) for breathe rate and heart rate detection. The second fundamental principle is reflectance based optical measurement using infrared or visible light. The variation in the light reflection is proportional to the volumetric change of the heart, often referred as photoplethysmography (PPG). Herein, we introduce the concept of terahertz-wave-plethysmography (TPG), which detects blood volume changes in the upper dermis tissue layer by measuring the reflectance of THz waves, similar to the existing remote PPG (rPPG) principle. The TPG principle is justified by scientific deduction, electromagnetic wave simulations and carefully designed experimental demonstrations. Additionally, pulse measurements from various peripheral body parts of interest (BOI), palm, inner elbow, temple, fingertip and forehead, are demonstrated using a wideband THz sensing system developed by the Terahertz Electronics Lab at Arizona State University, Tempe. Among the BOIs under test, it is found that the measurements from forehead BOI gives the best accuracy with mean heart rate (HR) estimation error 1.51 beats per minute (BPM) and standard deviation 1.08 BPM. The results validate the feasibility of TPG for direct pulse monitoring. A comparative study on pulse sensitivity is conducted between TPG and rPPG. The results indicate that the TPG contains more pulsatile information from the forehead BOI than that in the rPPG signals in regular office lighting condition and thus generate better heart rate estimation statistic in the form of empirical cumulative distribution function of HR estimation error. Last but not least, TPG penetrability test for covered skin is demonstrated using two types of garment materials commonly used in daily life.
Topics: Heart Rate; Humans; Photoplethysmography; Plethysmography; Pulse; Radar
PubMed: 35428772
DOI: 10.1038/s41598-022-09801-w -
Sensors (Basel, Switzerland) Jan 2023Despite the notable recent developments in the field of remote photoplethysmography (rPPG), extracting a reliable pulse rate variability (PRV) signal still remains a...
Despite the notable recent developments in the field of remote photoplethysmography (rPPG), extracting a reliable pulse rate variability (PRV) signal still remains a challenge. In this study, eight image-based photoplethysmography (iPPG) extraction methods (GRD, AGRD, PCA, ICA, LE, SPE, CHROM, and POS) were compared in terms of pulse rate (PR) and PRV features. The algorithms were made robust for motion and illumination artifacts by using ad hoc pre- and postprocessing steps. Then, they were systematically tested on the public dataset UBFC-RPPG, containing data from 42 subjects sitting in front of a webcam (30 fps) while playing a time-sensitive mathematical game. The performances of the algorithms were evaluated by statistically comparing iPPG-based and finger-PPG-based PR and PRV features in terms of Spearman's correlation coefficient, normalized root mean square error (NRMSE), and Bland-Altman analysis. The study revealed POS and CHROM techniques to be the most robust for PR estimation and the assessment of overall autonomic nervous system (ANS) dynamics by using PRV features in time and frequency domains. Furthermore, we demonstrated that a reliable characterization of the vagal tone is made possible by computing the Poincaré map of PRV series derived from the POS and CHROM methods. This study supports the use of iPPG systems as promising tools to obtain clinically useful and specific information about ANS dynamics.
Topics: Humans; Photoplethysmography; Signal Processing, Computer-Assisted; Heart Rate; Diagnostic Imaging; Algorithms; Wearable Electronic Devices
PubMed: 36772543
DOI: 10.3390/s23031505 -
Physiological Reports Jun 2022Trauma patients may suffer significant blood loss, and noninvasive methods to diagnose hypovolemia in these patients are needed. Physiologic effects of hypovolemia,...
Trauma patients may suffer significant blood loss, and noninvasive methods to diagnose hypovolemia in these patients are needed. Physiologic effects of hypovolemia, aiming to maintain blood pressure, are largely mediated by increased sympathetic nervous activity. Trauma patients may however experience pain, which also increases sympathetic nervous activity, potentially confounding measures of hypovolemia. Elucidating the common and separate effects of the two stimuli on diagnostic methods is therefore important. Lower body negative pressure (LBNP) and cold pressor test (CPT) are experimental models of central hypovolemia and pain, respectively. In the present analysis, we explored the effects of LBNP and CPT on pre-ejection period and pulse transit time, aiming to further elucidate the potential use of these variables in diagnosing hypovolemia in trauma patients. We exposed healthy volunteers to four experimental sequences with hypovolemia (LBNP 60 mmHg) or normovolemia (LBNP 0 mmHg) and pain (CPT) or no pain (sham) in a 2 × 2 fashion. We calculated pre-ejection period and pulse transit time from ECG and ascending aortic blood velocity (suprasternal Doppler) and continuous noninvasive arterial pressure waveform (volume-clamp method). Fourteen subjects were available for the current analyses. This experimental study found that pre-ejection period increased with hypovolemia and remained unaltered with pain. Pulse transit time was reduced by pain and increased with hypovolemia. Thus, the direction of change in pulse transit time has the potential to distinguish hypovolemia and pain.
Topics: Healthy Volunteers; Heart Rate; Humans; Hypovolemia; Lower Body Negative Pressure; Pain; Pulse Wave Analysis
PubMed: 35748055
DOI: 10.14814/phy2.15355 -
Journal of Neurophysiology Dec 2021Phrenic afferents project to brainstem areas responsible for cardiorespiratory control and the mid-cervical spinal cord containing the phrenic motor nucleus. Our purpose...
Phrenic afferents project to brainstem areas responsible for cardiorespiratory control and the mid-cervical spinal cord containing the phrenic motor nucleus. Our purpose was to quantify the impact of small- and large-diameter phrenic afferent activation on phrenic motor output. Anesthetized and ventilated rats received unilateral phrenic nerve stimulation while contralateral phrenic motor output and blood pressure were recorded. Twelve currents of 40-Hz inspiratory-triggered stimulation were delivered (20 s on, 5 min off) to establish current response curves. Stimulation pulse width was varied to preferentially activate large-diameter phrenic afferents (narrow pulse width) and recruit small-diameter fibers (wide pulse width). Contralateral phrenic amplitude was elevated immediately poststimulation at currents above 35 µA for wide and 70 µA for narrow pulse stimulation when compared with animals not receiving stimulation (time controls). Wide pulse width stimulation also increased phrenic burst frequency at currents ≥35 µA, caused a transient decrease in mean arterial blood pressure at currents ≥50 µA, and resulted in a small change in heart rate at 300 µA. Unilateral dorsal rhizotomy attenuated stimulation-induced cardiorespiratory responses indicating that phrenic afferent activation is required. Additional analyses compared phrenic motor amplitude with output before stimulation and showed that episodic activation of phrenic afferents with narrow pulse stimulation can induce short-term plasticity. We conclude that the activation of phrenic afferents ) enhances contralateral phrenic motor amplitude when large-diameter afferents are activated, and ) when small-diameter fibers are recruited, the amplitude response is associated with changes in burst frequency and cardiovascular parameters. Acute, inspiratory-triggered stimulation of phrenic afferents increases contralateral phrenic motor amplitude in adult rats. When small-diameter afferents are recruited, the amplitude response is accompanied by an increase in phrenic burst frequency, a transient decrease in mean arterial blood pressure, and a slight increase in heart rate. Repeated episodes of large-diameter phrenic afferent activation may also be capable of inducing short-term plasticity.
Topics: Afferent Pathways; Animals; Arterial Pressure; Blood Gas Analysis; Electrophysiological Phenomena; Female; Heart Rate; Hemodynamics; Inhalation; Male; Neuronal Plasticity; Neurons, Afferent; Phrenic Nerve; Rats; Rats, Sprague-Dawley
PubMed: 34788165
DOI: 10.1152/jn.00433.2021 -
IEEE Transactions on Bio-medical... May 2020Near-infrared (NIR) remote photoplethysmography (PPG) promises attractive applications in darkness, as it involves unobtrusive, invisible light. However, since the PPG...
Near-infrared (NIR) remote photoplethysmography (PPG) promises attractive applications in darkness, as it involves unobtrusive, invisible light. However, since the PPG strength (AC/DC) is much lower in the NIR spectrum than in the RGB spectrum, robust vital signs monitoring is more challenging. In this paper, we propose a new PPG-extraction method, DIScriminative signature based extraction (DIS), to significantly improve the pulse-rate measurement in NIR. Our core idea is to use both the color signals containing blood absorption variations and additional disturbance signals as input for PPG extraction. By defining a discriminative signature, we use one-step least-squares regression (joint optimization) to retrieve the pulsatile component from color signals and suppress disturbance signals simultaneously. A large-scale lab experiment, recorded in NIR with heavy body motions, shows the significant improvement of DIS over the state-of-the-art method, whereas its principle is simple and generally applicable.
Topics: Heart Rate; Least-Squares Analysis; Photoplethysmography; Signal Processing, Computer-Assisted
PubMed: 31484105
DOI: 10.1109/TBME.2019.2938564