Diabetes Research and Clinical Practice Jun 2023To conduct a meta-analysis of differences in physical activity, sedentary behaviour, and physical fitness between children and adolescents with type 1 diabetes and their... (Meta-Analysis)
Meta-Analysis Review
AIMS
To conduct a meta-analysis of differences in physical activity, sedentary behaviour, and physical fitness between children and adolescents with type 1 diabetes and their healthy peers.
METHODS
The databases EMBASE, PubMed and SportsDiscus were searched for studies. Pooled effects were calculated using random effects inverse-variance models with the Hartung-Knapp-Sidik-Jonkman adjustment.
RESULTS
Thirty-five studies were included, comprising a total of 4,751 youths (53% girls, 2,452 with type 1 diabetes). Youth with type 1 diabetes were less physically active (Cohen's d = -0.23, 95%CI - 0.42 to -0.04), more sedentary (Cohen's d = 0.33, 95%CI 0.06 to 0.61), and had lower cardiorespiratory fitness (Cohen's d = -0.52, 95%CI - 0.73 to -0.31) than their healthy peers. This corresponds to -12.72 min/day of moderate-to-vigorous physical activity, 63.3 min/day of sedentary time (accelerometry) and -4.07 ml/kg/min of maximum/peak oxygen consumption. In addition, young people with type 1 diabetes were less likely to meet the international physical activity recommendations than their healthy peers (odds ratio = 0.44, 95%CI 0.31 to 0.62).
CONCLUSIONS
Keeping in mind the heterogeneity between studies in the design, population and assessment, our findings show that children and adolescents with type 1 diabetes seem to be less active, more sedentary, and have lower cardiorespiratory fitness levels than their healthy peers.
Topics: Female; Child; Humans; Adolescent; Male; Sedentary Behavior; Diabetes Mellitus, Type 1; Exercise; Physical Fitness; Cardiorespiratory Fitness
PubMed: 37169308
DOI: 10.1016/j.diabres.2023.110697 -
ESC Heart Failure Oct 2020Accelerometers are becoming increasingly commonplace for assessing physical activity; however, their use in patients with cardiovascular diseases is relatively... (Review)
Review
AIMS
Accelerometers are becoming increasingly commonplace for assessing physical activity; however, their use in patients with cardiovascular diseases is relatively substandard. We aimed to systematically review the methods used for collecting and processing accelerometer data in cardiology, using the example of heart failure, and to provide practical recommendations on how to improve objective physical activity assessment in patients with cardiovascular diseases by using accelerometers.
METHODS AND RESULTS
Four electronic databases were searched up to September 2019 for observational, interventional, and validation studies using accelerometers to assess physical activity in patients with heart failure. Study and population characteristics, details of accelerometry data collection and processing, and description of physical activity metrics were extracted from the eligible studies and synthesized. To assess the quality and completeness of accelerometer reporting, the studies were scored using 12 items on data collection and processing, such as the placement of accelerometer, days of data collected, and criteria for non-wear of the accelerometer. In 60 eligible studies with 3500 patients (of those, 536 were heart failure with preserved ejection fraction patients), a wide variety of accelerometer brands (n = 27) and models (n = 46) were used, with Actigraph being the most frequent (n = 12), followed by Fitbit (n = 5). The accelerometer was usually worn on the hip (n = 32), and the most prevalent wear period was 7 days (n = 22). The median wear time required for a valid day was 600 min, and between two and five valid days was required for a patient to be included in the analysis. The most common measures of physical activity were steps (n = 20), activity counts (n = 15), and time spent in moderate-to-vigorous physical activity (n = 14). Only three studies validated accelerometers in a heart failure population, showing that their accuracy deteriorates at slower speeds. Studies failed to report between one and six (median 4) of the 12 scored items, with non-wear time criteria and valid day definition being the most underreported items.
CONCLUSIONS
The use of accelerometers in cardiology lacks consistency and reporting on data collection, and processing methods need to be improved. Furthermore, calculating metrics based on raw acceleration and machine learning techniques is lacking, opening the opportunity for future exploration. Therefore, we encourage researchers and clinicians to improve the quality and transparency of data collection and processing by following our proposed practical recommendations for using accelerometers in patients with cardiovascular diseases, which are outlined in the article.
Topics: Accelerometry; Cardiovascular Diseases; Exercise; Heart Failure; Humans
PubMed: 32618431
DOI: 10.1002/ehf2.12781 -
The International Journal of Behavioral... Nov 2021Physical activity (PA) and sedentary behaviour (SB) of pre-school aged children are associated with important health and developmental outcomes. Accurate measurement of... (Review)
Review
A systematic review of the validity, reliability, and feasibility of measurement tools used to assess the physical activity and sedentary behaviour of pre-school aged children.
Physical activity (PA) and sedentary behaviour (SB) of pre-school aged children are associated with important health and developmental outcomes. Accurate measurement of these behaviours in young children is critical for research and practice in this area. The aim of this review was to examine the validity, reliability, and feasibility of measurement tools used to assess PA and SB of pre-school aged children.Searches of electronic databases, and manual searching, were conducted to identify articles that examined the measurement properties (validity, reliability or feasibility) of measurement tools used to examine PA and/or SB of pre-school aged children (3-7 years old). Following screening, data were extracted and risk of bias assessment completed on all included articles.A total of 69 articles, describing 75 individual studies were included. Studies assessed measurement tools for PA (n = 27), SB (n = 5), and both PA and SB (n = 43). Outcome measures of PA and SB differed between studies (e.g. moderate to vigorous activity, step count, posture allocation). Most studies examined the measurement properties of one measurement tool only (n = 65). Measurement tools examined included: calorimetry, direct observation, combined heart rate and accelerometry, heart rate monitors, accelerometers, pedometers, and proxy report (parent, carer or teacher reported) measures (questionnaires or diaries). Studies most frequently assessed the validity (criterion and convergent) (n = 65), face and content validity (n = 2), test-retest reliability (n = 10) and intra-instrument reliability (n = 1) of the measurement tools. Feasibility data was abstracted from 41 studies.Multiple measurement tools used to measure PA and SB in pre-school aged children showed some degree of validity, reliability and feasibility, but often for different purposes. Accelerometers, including the Actigraph (in particular GT3X versions), Actical, ActivPAL and Fitbit (Flex and Zip), and proxy reported measurement tools used in combination may be useful for a range of outcome measures, to measure intensity alongside contextual information.
Topics: Accelerometry; Child; Child, Preschool; Exercise; Feasibility Studies; Humans; Reproducibility of Results; Sedentary Behavior
PubMed: 34732219
DOI: 10.1186/s12966-021-01132-9 -
Preventive Medicine Reports Sep 2020Regular physical activity is associated with physiological and psychosocial benefits in both healthy and clinical populations. However, little is known about tailoring... (Review)
Review
Regular physical activity is associated with physiological and psychosocial benefits in both healthy and clinical populations. However, little is known about tailoring the analysis of physical activity using accelerometers to the specific characteristics of chronic conditions. Whilst accelerometry is broadly used to assess physical activity, recommendations on calibration in paediatric clinical groups are warranted. The aim of this systematic review was to provide a critical overview of protocols used to calibrate accelerometry in children and adolescents with clinical conditions, as well as to develop recommendations for calibration and validation of accelerometry in such populations. The search was performed between March to July 2017 using text words and subject headings in six databases. Studies had to develop moderate-to-vigorous intensity physical activity (MVPA) cut-points for paediatric clinical populations to be included. Risk of bias was assessed using a specific checklist. A total of 540,630 titles were identified, with 323 full-text articles assessed. Five studies involving 347 participants aged 9 to 15 years were included. Twenty-four MVPA cut-points were reported across seven clinical conditions, 16 of which were developed for different models of ActiGraph, seven for Actical and one for Tritrac-R3D. Statistical approaches included mixed regression, machine learning and receiver operating characteristic analyses. Disease-specific MVPA cut-points ranged from 152 to 735 counts·15 s, with lower cut-points found for inherited muscle disease and higher cut-points associated with intellectual disabilities. The lower MVPA cut-points for diseases characterised by both ambulatory and metabolic impairments likely reflect the higher energetic demands associated with those conditions.
PubMed: 32637301
DOI: 10.1016/j.pmedr.2020.101142 -
Psychological Medicine May 2022Psychomotor slowing is a key feature of depressive disorders. Despite its great clinical importance, the pathophysiology and prevalence across different diagnoses and... (Meta-Analysis)
Meta-Analysis Review
Psychomotor slowing is a key feature of depressive disorders. Despite its great clinical importance, the pathophysiology and prevalence across different diagnoses and mood states are still poorly understood. Actigraphy allows unbiased, objective, and naturalistic assessment of physical activity as a marker of psychomotor slowing. Yet, the true effect-sizes remain unclear as recent, large systematic reviews are missing. We conducted a novel meta-analysis on actigraphically measured slowing in depression with strict inclusion and exclusion criteria for diagnosis ascertainment and sample duplications. Medline/PubMed and Web-of-Science were searched with terms combining mood-keywords and actigraphy-keywords until September 2021. Original research measuring actigraphy for ⩾24 h in at least two groups of depressed, remitted, or healthy participants and applying operationalized diagnosis was included. Studies in somatically ill patients, N < 10 participants/group, and studies using consumer-devices were excluded. Activity-levels between groups were compared using random-effects models with standardized-mean-differences and several moderators were examined. In total, 34 studies (n = 1804 patients) were included. Patients had lower activity than controls [standardized mean difference (s.m.d.) = -0.78, 95% confidence interval (CI) -0.99 to -0.57]. Compared to controls, patients with unipolar and bipolar disorder had lower activity than controls whether in depressed (unipolar: s.m.d. = -0.82, 95% CI -1.07 to -0.56; bipolar: s.m.d. = -0.94, 95% CI -1.41 to -0.46), or remitted/euthymic mood (unipolar: s.m.d. = -0.28, 95% CI -0.56 to 0.0; bipolar: s.m.d. = -0.92, 95% CI -1.36 to -0.47). None of the examined moderators had any significant effect. To date, this is the largest meta-analysis on actigraphically measured slowing in mood disorders. They are associated with lower activity, even in the remitted/euthymic mood-state. Studying objective motor behavior via actigraphy holds promise for informing screening and staging of affective disorders.
Topics: Actigraphy; Bipolar Disorder; Depression; Humans; Mood Disorders
PubMed: 35550677
DOI: 10.1017/S0033291722000903 -
The International Journal of Behavioral... Sep 2022Accurate accelerometer-based methods are required for assessment of 24-h physical behavior in young children. We aimed to summarize evidence on measurement properties of... (Review)
Review
BACKGROUND
Accurate accelerometer-based methods are required for assessment of 24-h physical behavior in young children. We aimed to summarize evidence on measurement properties of accelerometer-based methods for assessing 24-h physical behavior in young children.
METHODS
We searched PubMed (MEDLINE) up to June 2021 for studies evaluating reliability or validity of accelerometer-based methods for assessing physical activity (PA), sedentary behavior (SB), or sleep in 0-5-year-olds. Studies using a subjective comparison measure or an accelerometer-based device that did not directly output time series data were excluded. We developed a Checklist for Assessing the Methodological Quality of studies using Accelerometer-based Methods (CAMQAM) inspired by COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN).
RESULTS
Sixty-two studies were included, examining conventional cut-point-based methods or multi-parameter methods. For infants (0-12 months), several multi-parameter methods proved valid for classifying SB and PA. From three months of age, methods were valid for identifying sleep. In toddlers (1-3 years), cut-points appeared valid for distinguishing SB and light PA (LPA) from moderate-to-vigorous PA (MVPA). One multi-parameter method distinguished toddler specific SB. For sleep, no studies were found in toddlers. In preschoolers (3-5 years), valid hip and wrist cut-points for assessing SB, LPA, MVPA, and wrist cut-points for sleep were identified. Several multi-parameter methods proved valid for identifying SB, LPA, and MVPA, and sleep. Despite promising results of multi-parameter methods, few models were open-source. While most studies used a single device or axis to measure physical behavior, more promising results were found when combining data derived from different sensor placements or multiple axes.
CONCLUSIONS
Up to age three, valid cut-points to assess 24-h physical behavior were lacking, while multi-parameter methods proved valid for distinguishing some waking behaviors. For preschoolers, valid cut-points and algorithms were identified for all physical behaviors. Overall, we recommend more high-quality studies evaluating 24-h accelerometer data from multiple sensor placements and axes for physical behavior assessment. Standardized protocols focusing on including well-defined physical behaviors in different settings representative for children's developmental stage are required. Using our CAMQAM checklist may further improve methodological study quality.
PROSPERO REGISTRATION NUMBER
CRD42020184751.
Topics: Accelerometry; Child, Preschool; Exercise; Humans; Infant; Infant, Newborn; Reproducibility of Results; Sedentary Behavior; Time Factors
PubMed: 36076221
DOI: 10.1186/s12966-022-01296-y -
Diagnostics (Basel, Switzerland) Dec 2020The correct development of postural control in children is fundamental to ensure that they fully reach their psychomotor capacities. However, this capacity is one of the... (Review)
Review
UNLABELLED
The correct development of postural control in children is fundamental to ensure that they fully reach their psychomotor capacities. However, this capacity is one of the least studied in the clinical and academic scope regarding children. The objective of this study was to analyze the degree of implementation of accelerometry as an evaluation technique for postural control in children and how it is being used.
METHODS
A systematic search was conducted in PubMed, SpringerLink, SportsDiscus, Medline, Scopus, and Web of Science with the following terms: balance, postural control, children, kids, accelerometry, and accelerometer.
RESULTS
The search generated a total of 18 articles. Two groups of studies were differentiated: those which exclusively included healthy individuals ( = 5) and those which included children with pathologies ( = 13). Accelerometry is being used in children mainly to assess the gait and static balance, as well as to identify the differences between healthy children and children with developmental disorders.
CONCLUSIONS
Accelerometry has a discrete degree of implementation as an evaluation tool to assess postural control. It is necessary to define a systematic method for the evaluation of postural control in pediatrics, in order to delve into the development of this capacity and its alterations in different neurodevelopmental disorders.
PubMed: 33375206
DOI: 10.3390/diagnostics11010008 -
Neurological Research and Practice 2020Diagnosis of functional movement disorders and specifically functional tremor (FT) (representing 50% of them) remains demanding. Additionally, due to heterogeneity of... (Review)
Review
BACKGROUND
Diagnosis of functional movement disorders and specifically functional tremor (FT) (representing 50% of them) remains demanding. Additionally, due to heterogeneity of the disorders, structured concepts and guidelines for diagnosis and therapy are difficult to establish. Ascertaining the state of knowledge to derive instructions for operating procedures is the aim of this review.
MAIN TEXT
Based on a standardized systematic literature research using the term "psychogenic tremor" in the MEDLINE database dating back ten years, 76 studies were evaluated. Conventional features of FT are variability of frequency and amplitude. Further, response to distraction by motor and cognitive tasks is a key diagnostic feature in differentiation between organic and functional origin. A variety of electrophysiological tests have been evaluated including surface electromyography and accelerometry to establish laboratory-supported criteria for diagnosing tremor. Also, finger tapping tests have been used to identify FT, showing positive potential as supplementary evidence.Imaging studies in general are mostly underpowered and imaging cannot be used on an individual basis. Therapeutic studies in FT often have a diagnostic component. Cognitive behavioral therapy should be the preferred psychological treatment independent of additional psychiatric symptoms. Other psychotherapeutic methods show lack of evidence concerning FT. Relaxation techniques and physiotherapy are an important additional feature, especially in children and adolescents. In regard to drug therapy, randomized and blinded trials are not available. A significant decrease in rating scales could be detected after active, not sham repetitive transcranial magnetic stimulation with a long-lasting effect. Also root magnetic stimulation seems to be effective. The clinical feature of tremor entrainment in FT can be used in combination with biofeedback as so-called tremor retrainment, using self-modulation of frequency and severity, to bring the movements under volitional control.
CONCLUSION
Diagnosis and treatment of FT is challenging and should include a combination of intensive clinical examination and targeted addition of standardized testing, especially electrophysiological methods. Often therapeutic effects have a diagnostic component. A multimodal strategy, considering psychological factors as a potential origin as well as maintaining effects seems to be most effective.
PubMed: 33324935
DOI: 10.1186/s42466-020-00073-1 -
JMIR MHealth and UHealth Apr 2022Although it is widely recognized that physical activity is an important determinant of health, assessing this complex behavior is a considerable challenge. (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Although it is widely recognized that physical activity is an important determinant of health, assessing this complex behavior is a considerable challenge.
OBJECTIVE
The purpose of this systematic review and meta-analysis is to examine, quantify, and report the current state of evidence for the validity of energy expenditure, heart rate, and steps measured by recent combined-sensing Fitbits.
METHODS
We conducted a systematic review and Bland-Altman meta-analysis of validation studies of combined-sensing Fitbits against reference measures of energy expenditure, heart rate, and steps.
RESULTS
A total of 52 studies were included in the systematic review. Among the 52 studies, 41 (79%) were included in the meta-analysis, representing 203 individual comparisons between Fitbit devices and a criterion measure (ie, n=117, 57.6% for heart rate; n=49, 24.1% for energy expenditure; and n=37, 18.2% for steps). Overall, most authors of the included studies concluded that recent Fitbit models underestimate heart rate, energy expenditure, and steps compared with criterion measures. These independent conclusions aligned with the results of the pooled meta-analyses showing an average underestimation of -2.99 beats per minute (k comparison=74), -2.77 kcal per minute (k comparison=29), and -3.11 steps per minute (k comparison=19), respectively, of the Fitbit compared with the criterion measure (results obtained after removing the high risk of bias studies; population limit of agreements for heart rate, energy expenditure, and steps: -23.99 to 18.01, -12.75 to 7.41, and -13.07 to 6.86, respectively).
CONCLUSIONS
Fitbit devices are likely to underestimate heart rate, energy expenditure, and steps. The estimation of these measurements varied by the quality of the study, age of the participants, type of activities, and the model of Fitbit. The qualitative conclusions of most studies aligned with the results of the meta-analysis. Although the expected level of accuracy might vary from one context to another, this underestimation can be acceptable, on average, for steps and heart rate. However, the measurement of energy expenditure may be inaccurate for some research purposes.
Topics: Accelerometry; Energy Metabolism; Exercise; Fitness Trackers; Heart Rate; Humans
PubMed: 35416777
DOI: 10.2196/35626 -
BMC Neurology Jun 2022Upper limb (UL) paresis is one of the most common stroke consequences and significantly restricts patients in everyday life. Instruments objectively measuring direct arm...
BACKGROUND
Upper limb (UL) paresis is one of the most common stroke consequences and significantly restricts patients in everyday life. Instruments objectively measuring direct arm use in stroke patients are lacking, but might be helpful to understand patients' impairment. Aiming to examine whether accelerometry is a suitable objective measure for everyday UL use in stroke patients, we conducted a systematic review on the association between accelerometer-derived measurements and clinical scales.
METHODS
Articles were systematically searched in PubMed, Scopus, Cochrane Library, PeDro and LIVIVO through December 12, 2021, screened for inclusion by AH, and subsequently independently screened by CK and MK. Disagreements were discussed until consensus. We included English and German peer-reviewed articles dealing with the validity of accelerometers as a measurement of UL use in stroke patients and eligible systematic reviews. Studies exclusively using accelerometry as an outcome parameter, book contributions, conference abstracts and case studies were excluded. Data extraction was conducted by AH and confirmed by CK focussing on study type, objective, accelerometer device, sample size, stroke status, assessments conducted, measurement method, wearing time and key results. We analysed all eligible articles regarding the correlation between accelerometry and other clinical assessments and the validity in accordance with the type of accelerometer.
RESULTS
Excluding duplicates, the initial search yielded 477 records. In the 34 eligible studies accelerometers was used with a predominance of tri-axial accelerometery (n = 12) and only few with two-axial application (n = 4). Regarding measures to examine association to accelerometer data different clinical scales were applied depending on the setting, the degree of impairment and/or the status of stroke. Cut-off values to determine correlations varied largely; most significant correlations are reported for the MAL [Range 0.31- 0.84] and the ARAT [Range 0.15-0.79].
CONCLUSIONS
Accelerometers can provide reliable data about daily arm use frequency but do not supply information about the movements´ quality and restrictions on everyday activities of stroke patients. Depending on the context, it is advisable to use both, accelerometry and other clinical measures. According to the literature there is currently no accelerometer device most suitable to measure UL activity. High correlations indicate that multi-dimensional accelerometers should be preferred.
Topics: Accelerometry; Activities of Daily Living; Humans; Paresis; Stroke; Stroke Rehabilitation; Upper Extremity
PubMed: 35705906
DOI: 10.1186/s12883-022-02743-w