Renal Failure Dec 2022Expanded hemodialysis (HDx) is a new dialysis modality, but a systematic review of the clinical effects of using HDx is lacking. This systematic review and meta-analysis... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Expanded hemodialysis (HDx) is a new dialysis modality, but a systematic review of the clinical effects of using HDx is lacking. This systematic review and meta-analysis aimed to assess the efficacy and safety of HDx for hemodialysis (HD) patients.
METHODS
PubMed, the Cochrane library, and EMBASE databases were systematically searched for prospective interventional studies comparing the efficacy and safety of HDx with those of high flux HD or HDF in HD patients.
RESULTS
Eighteen trials including a total of 853 HD patients were enrolled. HDx increased the reduction ratio (RR) of β2-microglobulin (SMD 6.28%, 95% CI 0.83, 1.73, = .02), κFLC (SMD 15.86%, 95% CI 6.96, 24.76, = .0005), and λFLC (SMD 22.42%, 95% CI, 17.95, 26.88, < .0001) compared with high flux HD. The RR of β2-microglobulin in the HDx group was lower than that in the HDF group (SMD -3.53%, 95% CI -1.16, -1.9, < .0001). HDx increased the RRs of κFLC (SMD 1.34%, 95% CI 0.52, 2.16, = .001) and λFLC (SMD 7.28%, 95% CI 1.08, 13.48, = .02) compared to HDF. There was no significant difference in albumin loss into the dialysate between the HDx and HDF groups (SMD 0.35 g/session, 95% CI -2.38, 3.09, = .8).
CONCLUSIONS
This meta-analysis indicated that compared with high-flux HD and HDF, HDx can increase the clearance of medium and large-molecular-weight uremic toxins. And it does not increase the loss of albumin compared with HDF.
Topics: Albumins; Dialysis Solutions; Humans; Prospective Studies; Renal Dialysis
PubMed: 35343378
DOI: 10.1080/0886022X.2022.2048855 -
Membranes Apr 2022The use of medium cut-off (MCO) polyarylethersulfone and polyvinylpyrrolidone blend membrane is an emerging mode in hemodialysis. Recent studies have shown that MCO... (Review)
Review
Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.
The use of medium cut-off (MCO) polyarylethersulfone and polyvinylpyrrolidone blend membrane is an emerging mode in hemodialysis. Recent studies have shown that MCO membranes exhibit a middle high molecular weight uremic toxin clearance superior to standard high flux hemodialysis. We conducted a systematic literature review and meta-analysis of randomized controlled trials to investigate whether MCO membranes efficiently increase the reduction ratio of middle molecules, and to explore the potential clinical applications of MCO membranes. We selected articles that compared beta 2-microglobulin (β2M), kappa free light chain (κFLC), lambda free light chain (λFLC), interleukin-6 (IL-6), and albumin levels among patients undergoing hemodialysis. Five randomized studies with 328 patients were included. The meta-analysis demonstrated a significantly higher reduction ratio of serum β2M (p < 0.0001), κFLC (p < 0.0001), and λFLC (p = 0.02) in the MCO group. No significant difference was found in serum IL-6 levels after hemodialysis. Albumin loss was observed in the MCO group (p = 0.04). In conclusion, this meta-analysis study demonstrated the MCO membranes’ superior ability to clear β2M, κFLC, and λFLC. Serum albumin loss is an issue and should be monitored. Further studies are expected to identify whether MCO membranes could significantly improve clinical outcomes and overall survival.
PubMed: 35629769
DOI: 10.3390/membranes12050443 -
Journal of Taibah University Medical... Jun 2023Diabetic nephropathy causes cardiovascular complications among individuals with diabetes which results in decreased kidney function and overall physical decline. The... (Review)
Review
Diabetic nephropathy causes cardiovascular complications among individuals with diabetes which results in decreased kidney function and overall physical decline. The objective of this systematic review was to determine effects of exercise on various renal function parameters amond individuals with type 2 diabetes and nephropathy. It was registered with PROSPERO (CRD42020198754). Total 6 databases (PubMed/Medline, Scopus, Web of Science, CINAHL, ProQuest, and Cochrane) were searched. Among 1734 records, only four randomized controlled trials were included. The review included a total of 203 participants (103 in the intervention group and 100 in the control/standard group) with type 2 diabetic nephropathy or stage 2,3, or 4 of chronic kidney disease. The meta-analysis showed no effects of exercise on serum creatinine, serum cystatin c and varied eGFR equations. However, exercise decreased urinary albumin to creatinine ratio, urinary protein to creatinine ratio, serum urea nitrogen, creatinine clearance, and urinary protein excretion while increasing urea clearance. Limited evidence on the reno-protective role of exercise demands future research in this direction.
PubMed: 36818178
DOI: 10.1016/j.jtumed.2022.11.002 -
Medicine Feb 2021The combination of Traditional Chinese medicine and Western medicine (TCM+WM) has been widely used in the treatment of glomerulosclerosis, but the results are still... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The combination of Traditional Chinese medicine and Western medicine (TCM+WM) has been widely used in the treatment of glomerulosclerosis, but the results are still controversial. This study will assess the clinical efficacy of TCM+WM for glomerulosclerosis and provide evidence-based medical data via meta-analysis.
METHOD
The MEDLINE, EMBASE, PubMed, Cochrane Central Registry of Controlled Trials, and multiple Chinese databases (Wan Fang, CNKI, and VIP) were searched for randomized controlled trials (RCT) that compared the effects of WM and TCM+WM. Review Manager 5.3 software was used for the meta-analysis of selected studies, and appropriate tests were performed to determine the quality, heterogeneity and sensitivity of these studies.
RESULTS
Sixteen RCTs met the inclusion criteria and were selected for the analysis. Compared with the placebo or WM-treated glomerulosclerosis patients, TCM+WM intervention significantly improved renal function indices including 24-hour urine protein quantity (24 h U-Pro), serum creatinine (Scr), blood urea nitrogen (BUN), creatinine clearance (Ccr). In addition, the serum albumin (ALB), triglyceride (TG), and cholesterol (CHOL) levels were also significantly improved (P < .05) in patients receiving the combination therapy. Finally, the combination of TCM+WM reduced the indices of glomerulosclerosis more effectively compared with WM alone.
CONCLUSION
The combination of TCM+WM can significantly improve the renal function and prognosis of patients with glomerulosclerosis.
Topics: Combined Modality Therapy; Drugs, Chinese Herbal; Glomerulosclerosis, Focal Segmental; Humans; Medicine, Chinese Traditional; Randomized Controlled Trials as Topic
PubMed: 33607841
DOI: 10.1097/MD.0000000000024799 -
Frontiers in Immunology 2022A number of population pharmacokinetic (PPK) models of anti-programmed cell death-1 (PD-1) monoclonal antibodies (mAbs) in multiple tumor types have been published to...
AIMS AND BACKGROUND
A number of population pharmacokinetic (PPK) models of anti-programmed cell death-1 (PD-1) monoclonal antibodies (mAbs) in multiple tumor types have been published to characterize the influencing factors of their pharmacokinetics. This review described PPK models of anti-PD-1 mAbs that investigate the magnitude and types of covariate effects in PK parameters, provide a reference for building PPK models of other anti-PD-1 mAbs, and identify areas requiring additional research to facilitate the application of PPK models.
METHODS
A systematic search for analyses of PPK models of eleven anti-PD-1 mAbs on the market that were carried out in humans was conducted using PubMed, Embase, and the Cochrane Library. The search covered the period from the inception of the databases to April 2022.
RESULTS
Currently, there are fourteen analyses on PPK models of anti-PD-1 mAbs summarized in this review, including seven models that refer to nivolumab, four referring to pembrolizumab, one referring to cemiplimab, one referring to camrelizumab, and one referred to dostarlimab. Most analyses described the pharmacokinetics of anti-PD-1 mAbs with a two-compartment model with time-varying clearance (CL) and a sigmoidal maximum effect. The estimated CL and volume of distribution in the central (V) ranged from 0.179 to 0.290 L/day and 2.98 to 4.46 L, respectively. The median (range) of interindividual variability (IIV) for CL and V was 30.9% (8.7%-50.8%) and 29.0% (4.32%-40.7%), respectively. The commonly identified significant covariates were body weight (BW) on CL and V, and albumin (ALB), tumor type, sex, and performance status (PS) on CL. Other less assessed significant covariates included lactate dehydrogenase (LDH), immunoglobulin G (IgG), ipilimumab coadministration (IPICO) on CL, and body mass index (BMI), malignant pleural mesothelioma (MESO) on V.
CONCLUSION
This review provides detailed information about the characteristics of PPK models of anti-PD-1 mAbs, the effects of covariates on PK parameters, and the current status of the application of the models. ALB, BW, specific tumor type, sex, and PS should be considered for the future development of the PPK model of anti-PD-1 mAbs. Other potential covariates that were assessed less frequently but still have significance (e.g., LDH, IgG, and IPICO) should not be ignored. Thus, further research and thorough investigation are needed to assess new or potential covariates, which will pave the way for personalized anti-PD-1 mAbs therapy.
Topics: Antibodies, Monoclonal, Humanized; Body Weight; Humans; Immunoglobulin G; Ipilimumab; Neoplasms; Nivolumab
PubMed: 35983041
DOI: 10.3389/fimmu.2022.871372 -
Chinese Medical Journal Jan 2023Whether high cut-off (HCO) membranes are more effective than high-flux (HF) membranes in patients requiring renal replacement therapy (RRT) remains controversial. The... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Whether high cut-off (HCO) membranes are more effective than high-flux (HF) membranes in patients requiring renal replacement therapy (RRT) remains controversial. The aim of this systematic review was to investigate the efficacy of HCO membranes regarding the clearance of inflammation-related mediators, β2-microglobulin and urea; albumin loss; and all-cause mortality in patients requiring RRT.
METHODS
We searched all relevant studies on PubMed, Embase, Web of Science, the Cochrane Library, and China National Knowledge Infrastructure, with no language or publication year restrictions. Two reviewers independently selected studies and extracted data using a prespecified extraction instrument. Only randomized controlled trials (RCTs) were included. Summary estimates of standardized mean differences (SMDs) or weighted mean differences (WMDs) and risk ratios (RRs) were obtained by fixed-effects or random-effects models. Sensitivity analyses and subgroup analyses were performed to determine the source of heterogeneity.
RESULTS
Nineteen RCTs involving 710 participants were included in this systematic review. Compared with HF membranes, HCO membranes were more effective in reducing the plasma level of interleukin-6 (IL-6) (SMD -0.25, 95% confidence interval (CI) -0.48 to -0.01, P = 0.04, I2 = 63.8%); however, no difference was observed in the clearance of tumor necrosis factor-α (TNF-α) (SMD 0.03, 95% CI -0.27 to 0.33, P = 0.84, I2 = 4.3%), IL-10 (SMD 0.22, 95% CI -0.12 to 0.55, P = 0.21, I2 = 0.0%), or urea (WMD -0.27, 95% CI -2.77 to 2.23, P = 0.83, I2 = 19.6%). In addition, a more significant reduction ratio of β 2 -microglobulin (WMD 14.8, 95% CI 3.78 to 25.82, P = 0.01, I2 = 88.3%) and a more obvious loss of albumin (WMD -0.25, 95% CI -0.35 to -0.16, P < 0.01, I2 = 40.8%) could be observed with the treatment of HCO membranes. For all-cause mortality, there was no difference between the two groups (risk ratio [RR] 1.10, 95% CI 0.87 to 1.40, P = 0.43, I2 = 0.0%).
CONCLUSIONS
Compared with HF membranes, HCO membranes might have additional benefits on the clearance of IL-6 and β 2-microglobulin but not on TNF-α, IL-10, and urea. Albumin loss is more serious with the treatment of HCO membranes. There was no difference in all-cause mortality between HCO and HF membranes. Further larger high-quality RCTs are needed to strengthen the effects of HCO membranes.
Topics: Humans; Albumins; Interleukin-10; Interleukin-6; Renal Replacement Therapy; Tumor Necrosis Factor-alpha
PubMed: 36848147
DOI: 10.1097/CM9.0000000000002150 -
Frontiers in Pharmacology 2020Astragaloside IV (AS-IV) has a variety of biological activities and is widely used to treat kidney diseases. We conducted a systematic review of 24 animal studies...
Astragaloside IV (AS-IV) has a variety of biological activities and is widely used to treat kidney diseases. We conducted a systematic review of 24 animal studies including 424 animals to evaluate the efficacy of AS-IV for diabetic nephropathy (DN); all current possible mechanisms were summarized. A search strategy was applied to eight databases from inception to June 2020. The CAMARADES 10-item quality checklist and Rev-Man 5.3 software were used to analyze the risks of bias of each study and data regarding outcome measures, respectively. The mean study quality score was 5.4 points (range 3-8 points). Meta-analyses data and comparisons between groups showed that AS-IV significantly slowed the progression of pathological signs in the kidney including glomeruli and tubules, increasing creatinine clearance rate, decreasing blood urea nitrogen, serum creatinine, 24-h urinary neutrophil gelatinase-associated lipocalin and N-acetyl--D-glucosaminidase, 24-h urinary albumin, 24-h urinary microalbumin and HbA1c. There were no significant differences between experimental and control groups with respect to mortality or levels of alanine aminotransferase and aspartate aminotransferase. In terms of the possible mechanisms of treatment of DN, AS-IV acts through antifibrotic, antioxidant, and antiapoptotic mechanisms, thereby alleviating endoplasmic reticulum stress, inhibiting mitochondrial fission, and increasing autophagic activity. Taken together, our findings suggest that AS-IV is a multifaceted renoprotective candidate drug for DN.
PubMed: 32695006
DOI: 10.3389/fphar.2020.00988 -
Canadian Journal of Kidney Health and... 2022Medium cut-off (MCO) membranes enhance large middle-molecule clearance while selectively retaining molecules >45 000 Da.
BACKGROUND
Medium cut-off (MCO) membranes enhance large middle-molecule clearance while selectively retaining molecules >45 000 Da.
OBJECTIVES
We undertook a systematic review and meta-analysis comparing the effects of MCO versus high-flux membranes on biomarkers.
METHODS
We searched MEDLINE, Embase, CINAHL, Cochrane Library, and Web of Science from January 2015 to July 2020, and gray literature sources from 2017. We included randomized (RS) and nonrandomized studies (NRS) comparing MCO and high-flux membranes in adults (>18 years) receiving maintenance hemodialysis. We performed study selection, data extraction, and quality appraisals in duplicate and used the Grading of Recommendations Assessment, Development, and Evaluation framework. Outcomes included solute removal (plasma clearance or dialysate quantitation), reduction ratios, and predialysis serum concentrations for a range of prespecified large middle molecules.
RESULTS
We identified 26 eligible studies (10 RS and 16 NRS; N = 1883 patients; patient-years = 1366.3). The mean difference (MD) for albumin removal was 2.31 g per session (95% confidence interval [CI], 2.79 to 1.83; high certainty), with a reduction in predialysis albumin of -0.12 g/dl (95% CI, -0.16 to -0.07; = 0%; high certainty) in the first 24 weeks, returning to normal (MD = -0.02 g/dl, 95% CI, -0.07 to -0.03; = 56%; high certainty) after 24 weeks. We also found with high certainty that MCO dialysis resulted in a large increase (standardized mean difference [SMD]> 2.0 for all) in β2-microglobulin, κ- and λ-free light chains, and myoglobin removal, resulting in moderate (SMD > 0.5) to large (SMD > 0.8) reductions in predialysis concentrations for all of these solutes. Medium cut-off dialysis increased the reduction ratio for tumor necrosis factor-alpha (TNF-α) by 7.7% (95% CI, 4.7 to 10.6; moderate certainty), and reduced predialysis TNF-α by SMD -0.48 (95% CI, -0.91 to -0.04; moderate certainty). We found with moderate certainty that MCO dialysis had little to no effect on predialysis interleukin-6 (IL-6) plasma concentrations. Medium cut-off dialysis reduced mRNA expression of TNF-α and IL-6 in peripheral leukocytes by MD -15% (95% CI, -19.6 to -10.4; moderate certainty) and -8.8% (95% CI, -10.2 to -7.4; moderate certainty), respectively.
CONCLUSION
Medium cut-off dialysis increases the clearance of a wide range of large middle molecules and likely reduces inflammatory mediators with a concomitant transient reduction in serum albumin concentration. The net effect of MCO dialysis on large middle molecules could translate into important clinical effects.
PubMed: 35070336
DOI: 10.1177/20543581211067090 -
Annals of Hepatology Mar 2024Hepatorenal syndrome (HRS) is a serious complication of cirrhosis treated with various medications. We aim to evaluate terlipressin and albumin's effectiveness and...
INTRODUCTION AND OBJECTIVES
Hepatorenal syndrome (HRS) is a serious complication of cirrhosis treated with various medications. We aim to evaluate terlipressin and albumin's effectiveness and safety compared to albumin and noradrenaline in adult hepatorenal disease patients.
MATERIALS AND METHODS
Clinical trials from four databases were included. Cochrane's approach for calculating bias risk was utilized. We rated the quality evaluation by Grading of Recommendations Assessment, Development, and Evaluation (GRADE). We included the following outcomes: serum creatinine (mg/dl), urine output (ml/24 h), mean arterial pressure (mmHg), reversal rate of HRS, mortality rate, blood plasma renin activity (ng/ml/h), plasma aldosterone concentration (pg/ml), urine sodium (mEq/l), and creatinine clearance (ml/min).
RESULTS
Our analysis of nine clinical studies revealed that the noradrenaline group was associated with higher creatinine clearance (MD = 4.22 [0.40, 8.05]), (P = 0.03). There were no significant differences in serum creatinine levels (MD = 0.03 [-0.07, 0.13]), urinary sodium (MD = -1.02 [-5.15, 3.11]), urine output (MD = 32.75 [-93.94, 159.44]), mean arterial pressure (MD = 1.40 [-1.17, 3.96]), plasma renin activity (MD = 1.35 [-0.17, 2.87]), plasma aldosterone concentration (MD = 55.35 [-24.59, 135.29]), reversal rate of HRS (RR = 1.15 [0.96, 1.37]), or mortality rate (RR = 0.87 [0.74, 1.01]) between the two groups (p-values > 0.05).
CONCLUSIONS
Noradrenaline is a safe alternative medical therapy for HRS.
PubMed: 38460713
DOI: 10.1016/j.aohep.2024.101495 -
Therapeutic Apheresis and Dialysis :... Aug 2022Medium cut-off (MCO) dialyzers were designed to provide better clearance of uremic toxins. We conducted a meta-analysis comparing MCO with high-flux (HF) dialyzers for... (Meta-Analysis)
Meta-Analysis
Medium cut-off (MCO) dialyzers were designed to provide better clearance of uremic toxins. We conducted a meta-analysis comparing MCO with high-flux (HF) dialyzers for the effect on uremic toxins in maintenance hemodialysis (HD) patients. Five databases were systematically searched for relevant studies and nine studies were identified finally. Reduction ratio (RR) of urea, urea, creatinine, β2-macroglobulin (β2-MG), kappa free light chain (κFLC), and lambda FLC (λFLC) levels were not significantly different between MCO and HF dialyzers. But RR of β2-MG, κFLC, and λFLC were greater for MCO than HF dialyzers. MCO dialyzers could better reduce tumor necrosis factor-α (TNF-α) levels. Subgroup analysis stratified by study design indicated that in randomized controlled trial (RCT) studies, albumin levels was lower in MCO than HF dialyzers group, but the two dialyzers treatments were equivalent in non-RCT subgroup. Compared with HF dialyzers, MCO dialyzers provided higher middle-molecules uremic toxins clearance and obviously reduced TNF-α levels.
Topics: Creatinine; Hemodiafiltration; Humans; Immunoglobulin Light Chains; Membranes, Artificial; Renal Dialysis; Tumor Necrosis Factor-alpha; Urea
PubMed: 34773675
DOI: 10.1111/1744-9987.13755