The Cochrane Database of Systematic... Aug 2021Traditionally, amalgam has been used for filling cavities in posterior teeth, and it continues to be the restorative material of choice in some low- and middle-income... (Review)
Review
BACKGROUND
Traditionally, amalgam has been used for filling cavities in posterior teeth, and it continues to be the restorative material of choice in some low- and middle-income countries due to its effectiveness and relatively low cost. However, there are concerns over the use of amalgam restorations (fillings) with regard to mercury release in the body and the environmental impact of mercury disposal. Dental composite resin materials are an aesthetic alternative to amalgam, and their mechanical properties have developed sufficiently to make them suitable for restoring posterior teeth. Nevertheless, composite resin materials may have potential for toxicity to human health and the environment. The United Nations Environment Programme has established the Minamata Convention on Mercury, which is an international treaty that aims "to protect the [sic] human health and the environment from anthropogenic emissions and releases of mercury and mercury compounds". It entered into force in August 2017, and as of February 2021 had been ratified by 127 governments. Ratification involves committing to the adoption of at least two of nine proposed measures to phase down the use of mercury, including amalgam in dentistry. In light of this, we have updated a review originally published in 2014, expanding the scope of the review by undertaking an additional search for harms outcomes. Our review synthesises the results of studies that evaluate the long-term effectiveness and safety of amalgam versus composite resin restorations, and evaluates the level of certainty we can have in that evidence.
OBJECTIVES
To examine the effects (i.e. efficacy and safety) of direct composite resin fillings versus amalgam fillings.
SEARCH METHODS
An information specialist searched five bibliographic databases up to 16 February 2021 and used additional search methods to identify published, unpublished and ongoing studies SELECTION CRITERIA: To assess efficacy, we included randomised controlled trials (RCTs) comparing dental composite resin with amalgam restorations in permanent posterior teeth that assessed restoration failure or survival at follow-up of at least three years. To assess safety, we sought non-randomised studies in addition to RCTs that directly compared composite resin and amalgam restorative materials and measured toxicity, sensitivity, allergy, or injury.
DATA COLLECTION AND ANALYSIS
We used standard methodological procedures expected by Cochrane.
MAIN RESULTS
We included a total of eight studies in this updated review, all of which were RCTs. Two studies used a parallel-group design, and six used a split-mouth design. We judged all of the included studies to be at high risk of bias due to lack of blinding and issues related to unit of analysis. We identified one new trial since the previous version of this review (2014), as well as eight additional papers that assessed safety, all of which related to the two parallel-group studies that were already included in the review. For our primary meta-analyses, we combined data from the two parallel-group trials, which involved 1645 composite restorations and 1365 amalgam restorations in 921 children. We found low-certainty evidence that composite resin restorations had almost double the risk of failure compared to amalgam restorations (risk ratio (RR) 1.89, 95% confidence interval (CI) 1.52 to 2.35; P < 0.001), and were at much higher risk of secondary caries (RR 2.14, 95% CI 1.67 to 2.74; P < 0.001). We found low-certainty evidence that composite resin restorations were not more likely to result in restoration fracture (RR 0.87, 95% CI 0.46 to 1.64; P = 0.66). Six trials used a split-mouth design. We considered these studies separately, as their reliability was compromised due to poor reporting, unit of analysis errors, and variability in methods and findings. Subgroup analysis showed that the findings were consistent with the results of the parallel-group studies. Three trials investigated possible harms of dental restorations. Higher urinary mercury levels were reported amongst children with amalgam restorations in two trials, but the levels were lower than what is known to be toxic. Some differences between amalgam and composite resin groups were observed on certain measures of renal, neuropsychological, and psychosocial function, physical development, and postoperative sensitivity; however, no consistent or clinically important harms were found. We considered that the vast number of comparisons made false-positive results likely. There was no evidence of differences between the amalgam and composite resin groups in neurological symptoms, immune function, and urinary porphyrin excretion. The evidence is of very low certainty, with most harms outcomes reported in only one trial.
AUTHORS' CONCLUSIONS
Low-certainty evidence suggests that composite resin restorations may have almost double the failure rate of amalgam restorations. The risk of restoration fracture does not seem to be higher with composite resin restorations, but there is a much higher risk of developing secondary caries. Very low-certainty evidence suggests that there may be no clinically important differences in the safety profile of amalgam compared with composite resin dental restorations. This review supports the utility of amalgam restorations, and the results may be particularly useful in parts of the world where amalgam is still the material of choice to restore posterior teeth with proximal caries. Of note, however, is that composite resin materials have undergone important improvements in the years since the trials informing the primary analyses for this review were conducted. The global phase-down of dental amalgam via the Minamata Convention on Mercury is an important consideration when deciding between amalgam and composite resin dental materials. The choice of which dental material to use will depend on shared decision-making between dental providers and patients in the clinic setting, and local directives and protocols.
Topics: Bias; Child; Composite Resins; Dental Amalgam; Dental Caries; Dentition, Permanent; Humans; Randomized Controlled Trials as Topic
PubMed: 34387873
DOI: 10.1002/14651858.CD005620.pub3 -
Clinical Oral Implants Research Jan 2022To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants.
MATERIALS AND METHODS
Based on a focused question and customized PICO framework, electronic (Medline/EMBASE/Cochrane) and manual searches for studies reporting the clinical outcomes of all-ceramic SCs and FDPs supported by ceramic implants ≥12 months were performed. The primary outcomes were reconstruction survival and the chipping proportion. The secondary outcomes were implant survival, technical complications, and patient-related outcome measurements. Meta-analyses were performed after 1, 2, and 5 years using random-effect meta-analyses.
RESULTS
Eight of the 1,403 initially screened titles and 55 full texts were included. Five reported on monolithic lithium disilicate (LS2) SCs, one on veneered zirconia SCs, and two on veneered zirconia SCs and FDPs, which reported all on cement-retained reconstructions (mean observation: 12.0-61.0 months). Meta-analyses estimated a 5-year survival rate of 94% (95% confidence interval [CI]: 82%-100%) for overall implant survival. Reconstruction survival proportions after 5 years were: monolithic LS2, 100% (95%CI: 95%-100%); veneered zirconia SCs, 89% (95%CI: 62%-100%); and veneered zirconia FDPs 94% (95%CI: 81%-100%). The chipping proportion after 5 years was: monolithic LS2, 2% (95%CI: 0%-11%); veneered zirconia SCs, 38% (95%CI: 24%-54%); and veneered zirconia FDPs, 57% (95%CI: 38%-76%). Further outcomes were summarized descriptively.
CONCLUSIONS
Due to the limited data available, only tendencies could be identified. All-ceramic reconstructions supported by ceramic implants demonstrated promising survival rates after mid-term observation. However, high chipping proportions of veneered zirconia SCs and, particularly, FDPs diminished the overall outcome. Monolithic LS2 demonstrated fewer clinical complications. Monolithic reconstructions could be a valid treatment option for ceramic implants.
Topics: Ceramics; Crowns; Dental Implants; Dental Porcelain; Dental Prosthesis Design; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Humans; Metal Ceramic Alloys; Zirconium
PubMed: 34665900
DOI: 10.1111/clr.13871 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication...
PURPOSE
This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.
STUDY SELECTION
We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses. In this paper, the computer-aided design/computer-aided manufacturing (CAD/CAM) framework, artificial teeth, and denture base materials are reported.
RESULTS
A variety of materials, such as cobalt-chromium alloy, titanium, zirconia, and polyether ether ketone, are used for dental CAD/CAM frameworks. The mechanical strength of the metal materials used for the CAD/CAM framework was superior to that of the cast framework. However, the fitness and surface roughness of the framework and clasp fabricated using a selective laser melting (SLM) method were not superior to those obtained via cast fabrication. Most material properties and the surface roughness of poly methyl methacrylate (PMMA) discs used for digital RPDs were superior to those of heat-cured PMMA.
CONCLUSION
The use of a CAD/CAM framework and PMMA disc for digital RPDs offers numerous advantages over conventional RPDs. However, technical challenges regarding the accuracy and durability of adhesion between the framework and denture base remain to be solved. In digital fabrication, human technical factors influence the quality of the framework.
Topics: Computer-Aided Design; Denture Bases; Denture, Partial, Removable; Humans; Tooth, Artificial; Workflow
PubMed: 33504722
DOI: 10.2186/jpr.JPR_D_20_00117 -
International Journal of Dentistry 2022The objective of this work is to study galvanic corrosion of different couples of prosthetic and implant alloys through the realization of a systematic review. (Review)
Review
PURPOSE
The objective of this work is to study galvanic corrosion of different couples of prosthetic and implant alloys through the realization of a systematic review.
MATERIALS AND METHODS
An electronic search was performed on Pubmed, Google Scholar, Scopus, ScienceDirect, EbscoHost, and Web of Science for published studies related to electrogalvanism in oral implantology. The keywords used were "dental implants" and "galvanic corrosion." Two independent readers read the scientific articles.
RESULTS
From 65 articles initially identified, only 19 articles met the eligibility criteria. The evaluation of the selected articles allowed us to determine the parameters compared, such as the resistance to galvanic corrosion, the influence of fluorine and pH on the electrochemical behavior, and the release of metal ions and their cytotoxicity. Indeed, Ti6Al4V and precious alloys coupled to titanium were found to be the most resistant to galvanic corrosion, followed by cobalt-chromium alloys and nickel-chromium alloys which were least resistant. This resistance decreases with increasing fluorine concentration and with decreasing pH of the environment. . The implant-prosthetic system's galvanic resistance is influenced by many intrinsic factors: alloy composition and surface condition, as well as extrinsic factors such as pH variations and amount of fluorine. The effects of oral electrogalvanism are essentially the result of two main criteria: effects due to electric currents generated by corrosion and effects due to the release of metal ions by corrosion.
CONCLUSION
To avoid this phenomenon, it is wise to follow the proposed recommendations such as the use of the minimum of distinct metals as much as possible, favoring the commercially pure titanium implant of Ti6Al4V, opting for the choice of couples, titanium/titanium, favoring daily mouthwashes of 227 ppm of fluoride, and avoiding fluorinated acid solutions.
PubMed: 36034476
DOI: 10.1155/2022/4575416 -
Bioinorganic Chemistry and Applications 2022Magnesium alloys have great application prospects as ideal bone implant materials. However, their poor corrosion resistance limits their clinical orthopedic application.... (Review)
Review
Magnesium alloys have great application prospects as ideal bone implant materials. However, their poor corrosion resistance limits their clinical orthopedic application. Surface modification promotes the corrosion resistance of magnesium. Conversion coatings, such as calcium phosphate (Ca-P) coating, microarc oxidation (MAO) treatment, and fluoride (FLU) treatment, have been extensively investigated in in vivo studies. This systematic review and network meta-analysis compared the influence of different conversion coatings on bone repair, material properties, and systemic host response in orthopedic applications. Using the PICOS model, the inclusion criteria for biodegradable magnesium and its alloys were determined for in vivo studies. Four databases were used. The standard and weight mean differences with 95% confidence intervals were used to analyze new bone formation and degradation rate. Network structure and forest plots were created, and ranking probabilities were estimated. The risk of bias and quality of evidence were assessed using SYRCLE, CERQual, and GRADE tools. In the qualitative analysis, 43 studies were selected, and the evaluation of each outcome indicator was not entirely consistent from article to article. In the quantitative analysis, 21 articles were subjected to network meta-analysis, with 16 articles on implant degradation and 8 articles for new bone formation. Additionally, SUCRA indicated that Ca-P coating exhibited the highest corrosion resistance, followed by FLU treatment. MAO demonstrated the best capability for new bone formation, followed by Ca-P coating. Ca-P coating exhibited the highest overall performance. To conclude, coated Mg can promote better new bone formation than bare Mg and has considerable biocompatibility. Ca-P-coated Mg and MAO-coated Mg have the greatest potential to significantly promote corrosion resistance and bone regeneration, respectively. The findings of this study will provide a theoretical basis for the investigation of composite coatings and guidance for the orthopedic application of Mg bone implants.
PubMed: 35399618
DOI: 10.1155/2022/4529520 -
Clinical Oral Implants Research Sep 2023For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other materials than titanium (alloy) on implant survival, marginal bone loss (MBL), and technical and biological complications after at least 5 years.
MATERIALS AND METHODS
An electronic (Medline, Embase, Web of Science) search was performed to identify observational clinical studies published from January 2000 investigating a minimum of 20 commercially available zirconia implants with a mean follow-up of at least 60 months. Primary outcome was implant survival, secondary outcomes included peri-implant MBL, probing depths (PDs), and technical and biological complications. Meta-analyses were performed to evaluate implant survival, MBL, and PD.
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 4 prospective and 2 retrospective observational clinical cohort studies were included for data extraction. Meta-analyses estimated after 5 years of loading mean values of 97.2% (95% CI 94.7-99.1) for survival (277 implants, 221 patients), 1.1 mm (95% CI: 0.9-1.3) for MBL (229 implants, 173 patients), and 3.0 mm (95% CI 2.5-3.4) for PDs (231 implants, 175 patients).
CONCLUSIONS
After 5 years, commercially available zirconia implants showed reliable clinical performance based on survival rates, MBL, and PD values. However, more well-designed prospective clinical studies and randomized clinical trials investigating titanium and zirconia implants are needed to confirm the presently evaluated promising outcomes.
Topics: Humans; Dental Implants; Prospective Studies; Retrospective Studies; Titanium; Bone Diseases, Metabolic
PubMed: 37750521
DOI: 10.1111/clr.14133 -
International Journal of Implant... Jul 2023The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses survival and success, sinus pathology and patient reported outcomes were also investigated.
METHODS
Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed. Embase and OvidMedline databases were searched alongside the grey literature. The systematic review was recorded in PROSPERO (CRD42022358024). Studies reporting titanium/titanium alloy ZI survival data, ZI-supported prosthesis data, ZIs directly compared to any other implant therapy including grafted sites, a minimum follow-up time of 3 years and a minimum number of 10 patients were included. All study designs were considered if they met the inclusion criteria. Studies not involving ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of < 3 years or < 10 patients, animal studies and in vitro studies were excluded. Long-term follow-up has not been defined in the literature. A minimum of 3 years follow-up was considered acceptable to capture survival after initial healing, alongside in-function prosthesis data via delayed or immediate load protocols. ZI success, was predominantly defined as ZI survival without biological or neurological complications. Meta-analyses were performed for ZI survival, ZI failure incidence, ZI success, loading protocol, prosthesis survival, and prevalence of sinusitis using random effects models. Descriptive analysis was used for ZI success, prosthesis success and patient reported outcome measures.
RESULTS
Five hundred and seventy-four titles were identified, of which 18 met the inclusion criteria. Eligible studies included 1349 ZIs in 623 patients. Mean follow-up period was 75.4 months (range 36-141.6). The mean survival of ZIs was 96.2% [95% CI: 93.8; 97.7] at 6 years. Mean survival for delayed loading was 95% [95% CI: 91.7; 97.1] and 98.1% [95% CI: 96.2; 99.0] for immediate loading (p = 0.03). Annual incidence rate of ZI failure was 0.7% [95% CI 0.4; 1.0]. Mean ZI success was 95.7% [95% CI 87.8; 98.6]. Mean prosthesis survival was 94% [95% CI 88.6; 96.9]. Sinusitis prevalence was 14.2% [95% CI 8.8; 22.0] at 5 years. Patients' reported increased satisfaction with ZIs.
CONCLUSIONS
ZIs have long-term survival comparable to conventional implants. Immediate loading showed a statistically significant increase in survival over delayed loading. Prosthesis survival was similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patients reported improved outcome measures with ZI use.
Topics: Humans; Dental Implantation, Endosseous; Dental Implants; Prosthesis Failure; Titanium; Treatment Outcome; Alloys
PubMed: 37405545
DOI: 10.1186/s40729-023-00479-x -
Clinical Oral Implants Research Sep 2023In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year?
MATERIALS AND METHODS
This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487).
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material.
CONCLUSIONS
Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.
Topics: Humans; Titanium; Dental Implants; Alloys; Aluminum Oxide
PubMed: 37750527
DOI: 10.1111/clr.14159 -
Materials (Basel, Switzerland) Jun 2021The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch... (Review)
Review
The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch prostheses. A literature search was conducted on MEDLINE, Scopus and Cochrane Library, until the 1st of March 2021, with the following search terms: framework or substructure combined with "dental implants". The outcomes evaluated were: implant and prosthesis survival, bone resorption, biological and technical complications. The Cochrane Handbook for Systematic Reviews of Interventions was employed to assess the risk of bias in randomized clinical trials. The Newcastle-Ottawa quality assessment scale was used for non-randomized studies. In total, 924 records were evaluated for title and abstract, and 11 studies were included in the review: 4 clinical randomized trials and 7 cohort studies. The framework materials investigated were: gold alloy, titanium, silver-palladium alloy, zirconia and polymers including acrylic resin and carbon-fiber-reinforced composites. High implant and prosthetic cumulative survival rates were recorded by all included studies. Various materials and different fabrication techniques are now available as alternatives to traditional cast metal frameworks, for full-arch implant-supported rehabilitations. Further long-term studies are needed to validate the use of these materials and clarify their specific clinical indications and manufacturing protocols to optimize their clinical outcomes.
PubMed: 34204681
DOI: 10.3390/ma14123251 -
Spine Deformity Nov 2022To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery.
METHODS
A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies.
RESULTS
Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt-chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°-55.42°] and Ti 32.58° [24.62°-40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°-29.53°] and Ti 20.15° [18.0°-22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7-22%) for CoCr and 12% (- 8-32%) for stainless steel (SS) (n = 2 studies each; Chi = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1-22%) for Ti (n = 3 studies) and 10% (2-19) for CoCr (n = 1 study). Among 6.0-6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°-14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°-40.62°), and pelvic tilt angle was 21.11° (18.35°-23.86°).
CONCLUSIONS
For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided.
LEVEL OF EVIDENCE
III.
Topics: Adult; Humans; Spinal Fusion; Stainless Steel; Titanium; Chromium Alloys; Pseudarthrosis; Cobalt; Chromium
PubMed: 35904725