-
Materials (Basel, Switzerland) Mar 2022In recent years, implantology has made significant progress, as it has now become a safe and predictable practice. The development of new geometries, primary and... (Review)
Review
In recent years, implantology has made significant progress, as it has now become a safe and predictable practice. The development of new geometries, primary and secondary, of new surfaces and alloys, has made this possible. The purpose of this review is to analyze the different alloys present on the market, such as that in zirconia, and evaluate their clinical differences with those most commonly used, such as those in grade IV titanium. The review, conducted on major scientific databases such as Scopus, PubMed, Web of Science and MDPI yielded a startling number of 305 results. After the application of the filters and the evaluation of the results in the review, only 10 Randomized Clinical Trials (RCTs) were included. Multiple outcomes were considered, such as Marginal Bone Level (MBL), Bleeding on Probing (BoP), Survival Rate, Success Rate and parameters related to aesthetic and prosthetic factors. There are currently no statistically significant differences between the use of zirconia implants and titanium implants, neither for fixed prosthetic restorations nor for overdenture restorations. Only the cases reported complain about the rigidity and, therefore, the possibility of fracture of the zirconium. Certainly the continuous improvement in these materials will ensure that they could be used safely while maintaining their high aesthetic performance.
PubMed: 35269211
DOI: 10.3390/ma15051979 -
Clinical Oral Investigations Dec 2023To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review.
METHODS
An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done.
RESULTS
Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up.
CONCLUSION
Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055).
CLINICAL RELEVANCE
The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Topics: Humans; Dental Implants; Treatment Outcome; Dental Restoration Failure; Zirconium; Titanium; Dental Prosthesis Design
PubMed: 38135804
DOI: 10.1007/s00784-023-05401-8 -
Spine Deformity Nov 2022To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery.
METHODS
A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies.
RESULTS
Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt-chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°-55.42°] and Ti 32.58° [24.62°-40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°-29.53°] and Ti 20.15° [18.0°-22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7-22%) for CoCr and 12% (- 8-32%) for stainless steel (SS) (n = 2 studies each; Chi = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1-22%) for Ti (n = 3 studies) and 10% (2-19) for CoCr (n = 1 study). Among 6.0-6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°-14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°-40.62°), and pelvic tilt angle was 21.11° (18.35°-23.86°).
CONCLUSIONS
For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided.
LEVEL OF EVIDENCE
III.
Topics: Adult; Humans; Spinal Fusion; Stainless Steel; Titanium; Chromium Alloys; Pseudarthrosis; Cobalt; Chromium
PubMed: 35904725
DOI: 10.1007/s43390-022-00556-y -
Journal of Orthodontic Science 2023A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we... (Review)
Review
A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we aimed to assess the various metallurgical characteristics of the said metals and alloys. Four hundred and eighty-two documents in total were found after a thorough search of the online journals, and 169 of the papers were initially chosen. Ultimately, 16 documents were selected that satisfied the necessary inclusion and exclusion criteria, primarily studies, literature reviews, and comparative analyses. NiTi alloy was found to be the most commonly used alloy in construction of orthodontic wires across all the studies that we had selected for our review. It also had better performance and consistency in terms of its usage as depicted by the meta-analysis performed, with stainless steel wires being a close second primarily due to its lesser cost compared to the former. Metallurgy and orthodontics are inextricably linked with one another. The various components of orthodontics such as wires, pliers, and other instruments utilize the metallurgical characteristics of metals and alloys that are specially prepared for the challenges of this field. CRD42022378444.
PubMed: 37881657
DOI: 10.4103/jos.jos_52_23 -
Journal of International Society of... 2020Dental implants are considered the best treatment option for replacement of missing teeth due to high survival rates and diverse applications. However, not all dental... (Review)
Review
BACKGROUND
Dental implants are considered the best treatment option for replacement of missing teeth due to high survival rates and diverse applications. However, not all dental implant therapies are successful and some fail due to various biological and or/mechanical factors. The objective of this study was to systematically review primary studies that focus on the biomechanical properties of dental implants in order to determine which biomechanical properties are most important for success of dental implant therapy.
MATERIALS AND METHODS
An electronic database search was performed using MEDLINE (PubMed), EMBASE, Google Scholar, and CAB Abstracts. Six principal biomechanical properties were considered to prepare the search strategy for each database using key words and Boolean operators. Human and animal studies (observational studies, trials, and studies) were included in this review. Human studies that were considered eligible needed to have subjects above 18 years who received permanent restorations after implant surgery and followed up for at least 6 months after receiving permanent restorations. Studies with subjects who had absolute contraindications at the time of dental implant surgery were excluded.
RESULTS
In total, 28 studies were included in the review after application of the eligibility criteria; 18 studies, 5 cohort clinical studies, 3 animal studies, and 2 nonrandomized trials. Six studies assessed loss of preload, five studies assessed fatigue strength, four assessed implant abutment connection design, and one assessed implant diameter. Two nonrandomized trials assessed torque and six observational studies assessed the effect of cantilevers. Gold alloy coating of abutment screws resulted in higher preload values followed by titanium alloy coating and gold coating; there was a difference in preload values between coated and uncoated screws when tightened repeatedly. Preload values decreased as a function of time with majority of preload loss occurred within 10s of tightening. The 8-degree internal conical implant performed better than the internal hex design. Higher rate of complications (porcelain chipping, de-cementation) was observed in the cantilever groups in studies.
CONCLUSION
Biomechanical properties of implants like preload, torque, cantilever design, implant abutment design have profound effects on the survival rates of dental implants. With limiations, this review provides some important parameters to consider for successful implant therapy.
PubMed: 33437702
DOI: 10.4103/jispcd.JISPCD_138_20 -
Clinical and Experimental Dental... Aug 2022This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces. (Review)
Review
OBJECTIVES
This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces.
MATERIAL AND METHODS
An electronic search for literature was conducted on PubMed, Embase, Scopus, and Web of Science and a total of 14 studies were included. Neutrophil responses were assessed based on adhesion, cell number, surface coverage, cell structure, cytokine secretion, reactive oxygen species (ROS) production, neutrophil activation, receptor expression, and neutrophil extracellular traps (NETs) release. The method of assessing the risk of bias was done using the toxicological data reliability assessment tool (TOXRTOOL).
RESULTS
Ten studies have identified a significant increase in neutrophil functions, such as surface coverage, cell adhesion, ROS production, and NETs released when interacting with rough titanium surfaces. Moreover, neutrophil interaction with rough-hydrophilic surfaces seems to produce less proinflammatory cytokines and ROS when compared to naive smooth and rough titanium surfaces. Regarding membrane receptor expression, two studies have reported that the FcγIII receptor (CD16) is responsible for initial neutrophil adhesion to hydrophilic titanium surfaces. Only one study compared neutrophil interaction with titanium alloy and zirconia toughened alumina surfaces and reported no significant differences in neutrophil cell count, activation, receptor expression, and death.
CONCLUSIONS
There are not enough studies to conclude neutrophil interactions with titanium and zirconia surfaces. However, different topographic modifications such as roughness and hydrophilicity might influence neutrophil interactions with titanium implant surfaces.
Topics: Dental Implants; Neutrophils; Reactive Oxygen Species; Reproducibility of Results; Surface Properties; Titanium; Zirconium
PubMed: 35535662
DOI: 10.1002/cre2.582 -
Clinical and Experimental Dental... Dec 2021Grade V titanium alloy (Ti-6Al-4 V) is a well-recognized metallic biomaterial for medical implants. There has been some controversy regarding the use of this alloy in... (Review)
Review
OBJECTIVES
Grade V titanium alloy (Ti-6Al-4 V) is a well-recognized metallic biomaterial for medical implants. There has been some controversy regarding the use of this alloy in medical devices in relation to the toxicity of vanadium. In Dentistry, Ti-6Al-4 V remains prevalent. This systematic review aims to evaluate the effects of Ti-6Al-4 V on cells relevant to oral environments such as gingival fibroblasts.
MATERIALS AND METHODS
A literature search was undertaken for relevant English language publications in the following databases: Dental and Oral Science, Medline and Web of Science. The electronic search was supplemented with a search of references.
RESULTS
After application of inclusion and exclusion criteria. A total of eight papers are included in this review. These papers were all in vitro studies and were categorized into whole implant, discs, or implant particles based on the type of test materials used in the studies.
CONCLUSION
Based on the analyses of the eight included studies in this review, if Ti-6Al-4 V as a material is unchallenged, i.e., as a whole implant in pH neutral environments, there appears to be little effect on fibroblasts. If Ti-6Al-4 V is challenged through corrosion or wear (particle release), the subsequent release of vanadium and aluminium particles has an increased cytotoxic effect in vitro in comparison to commercially pure titanium, hence concerns should be raised in the clinical setting.
Topics: Alloys; Dental Implants; Fibroblasts; Materials Testing; Titanium
PubMed: 34018703
DOI: 10.1002/cre2.444 -
The British Journal of Oral &... Jul 2023Evidence is limited on whether titanium-zirconium alloy, narrow-diameter implants (Ti-Zr NDIs) have promising clinical outcomes when used to support single crowns. The... (Meta-Analysis)
Meta-Analysis Review
Evidence is limited on whether titanium-zirconium alloy, narrow-diameter implants (Ti-Zr NDIs) have promising clinical outcomes when used to support single crowns. The purpose of this systematic review and meta-analysis was to evaluate clinical evidence, including survival rates, success rates, and marginal bone loss (MBL) on Ti-Zr NDIs that support single crowns. An extensive search was performed in the databases of PubMed/MEDLINE, Scopus, Embase, and the Cochrane Library for studies published in English up to April 2022. Only peer-reviewed clinical studies with at least 10 patients and a follow-up time of at least 12 months were included. Risk of bias in each study was assessed and data extraction was carried out independently by two reviewers. The outcome variables were survival rates, success rates, and MBL. The search returned 779 results. Eight studies were identified for qualitative analysis and seven for quantitative synthesis. Overall, a total of 256 Ti-Zr NDIs were included. Cumulative implant survival rates and success rates were 97.5% (95% confidence interval (CI): 94.5% to 98.9%) and 97.2% (95% CI: 94.2% to 98.7%), respectively, over a maximum follow-up period of 36 months, with no difference between Ti-Zr NDIs and commercial pure titanium (cpTi) implants. Cumulative mean (SD) MBL was 0.44 (0.04) mm (95% CI: 0.36 to 0.52) after one year. Meta-analysis of MBL indicated a mean difference of 0.02 mm (95% CI: -0.23 to 0.10), with no differences between Ti-Zr NDIs and cpTi implants. Short-term results of Ti-Zr NDIs for single-crown restorations are quite promising, although the number of published studies and follow-up periods are insufficient to determine the real benefit for single crowns. Long-term, follow-up clinical studies are needed to verify the excellent clinical performance of Ti-Zr NDIs.
Topics: Humans; Titanium; Zirconium; Dental Prosthesis Design; Alloys; Crowns; Dental Implants; Dental Restoration Failure
PubMed: 37331853
DOI: 10.1016/j.bjoms.2023.05.005 -
Frontiers in Bioscience (Landmark... Dec 2021The fracture of endodontic instruments inside the canal represents a problem that is not always easy to solve. The reutilization of endodontic instruments after... (Meta-Analysis)
Meta-Analysis Review
The fracture of endodontic instruments inside the canal represents a problem that is not always easy to solve. The reutilization of endodontic instruments after sterilization procedures raises the question of how these processes affect their physical and mechanical properties. Alterations can involve the surface of the instruments, as well as their cutting effectiveness, shape and resistance to torsional and cyclic fatigue. The methodology adopted for this systematic review followed the PRISMA guidelines for systematic reviews. The following search terms were used in PubMed and Scopus: "endodontic sterilization", "endodontic autoclave", "cyclic fatigue", "torsional", "cutting efficiency", "sterilization", "surface characteristics" and "corrosion". After the screening phase, the application of exclusion criteria and the removal of duplicates, 51 studies were identified and divided into four outcomes: cyclic fatigue; deformation and torsional fatigue; corrosion or surface alterations; and cutting efficiency. Our study of the scientific literature highlights disagreements between studies on these effects. After autoclaving, instruments exhibit a reduction in the cutting efficiency, but NiTi alloy instruments have an improved resistance to cyclic and torsional fatigue.
Topics: Equipment Failure; Materials Testing; Network Meta-Analysis; Root Canal Preparation; Sterilization; Stress, Mechanical
PubMed: 34994183
DOI: 10.52586/5062 -
PeerJ 2022Titanium dioxide dental implants have a controversial effect on reactive oxygen species (ROS) production. ROS is necessary for cellular signal transmission and proper... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Titanium dioxide dental implants have a controversial effect on reactive oxygen species (ROS) production. ROS is necessary for cellular signal transmission and proper metabolism, but also has the ability to cause cell death as well as DNA, RNA, and proteins damage by excessive oxidative stress. This study aimed to systematically review the effect of titanium dioxide dental implant-induced oxidative stress and its role on the osteogenesis-angiogenesis coupling in bone remodeling.
METHODS
This systematic review was performed conforming to preferred reporting items for systematic review and meta-analysis (PRISMA) model. Four different databases (PubMed, Science Direct, Scopus and Medline databases) as well as manual searching were adopted. Relevant studies from January 2000 till September 2021 were retrieved. Critical Appraisal Skills Programme (CASP) was used to assess the quality of the selected studies.
RESULTS
Out of 755 articles, only 14 which met the eligibility criteria were included. Six studies found that titanium dioxide nanotube (TNT) reduced oxidative stress and promoted osteoblastic activity through its effect on Wnt, mitogen-activated protein kinase (MAPK) and forkhead box protein O1 (FoxO1) signaling pathways. On the other hand, three studies confirmed that titanium dioxide nanoparticles (TiONPs) induce oxidative stress, reduce ostegenesis and impair antioxidant defense system as a significant negative correlation was found between decreased SIR3 protein level and increased superoxide (O ). Moreover, five studies proved that titanium implant alloy enhances the generation of ROS and induces cytotoxicity of osteoblast cells via its effect on NOX pathway.
CONCLUSION
TiONPs stimulate a wide array of oxidative stress related pathways. Scientific evidence are in favor to support the use of TiO nanotube-coated titanium implants to reduce oxidative stress and promote osteogenesis in bone remodeling. To validate the cellular and molecular cross talk in bone remodeling of the present review, well-controlled clinical trials with a large sample size are required.
Topics: Reactive Oxygen Species; Titanium; Dental Implants; Oxidative Stress; Bone Remodeling
PubMed: 35261818
DOI: 10.7717/peerj.12951