-
Clinical and Experimental Dental... Aug 2022The aim of this systematic review is to analyze literature regarding the relationship between the implant-abutment emergence angle (EA) and implant emergence profile... (Review)
Review
STATEMENT
The aim of this systematic review is to analyze literature regarding the relationship between the implant-abutment emergence angle (EA) and implant emergence profile (EP) and the prevalence of peri-implantitis.
METHODS
PubMed and the Cochrane Library were searched for studies from initiation up to April 2022. Studies describing the EA and EP in association with peri-implantitis were considered eligible for this review and selected for inclusion in this review if implant groups with wide and narrow EA and different EP types were described.
RESULTS
Searches in PubMed and the Cochrane Library led to 1116 unique titles and the inclusion of three studies. These concerned 168-349 implants. Two studies presented the mean prevalence of peri-implantitis which was 16.7% and 24.8% at the implant level. Both studies showed a significant relationship between peri-implantitis in bone-level implant groups with an EA above 30° compared to implants with an EA below 30°. A third study presented marginal bone loss which tended to be smaller when the EA was around 20°-40°. In one of the three included studies, the prevalence of peri-implantitis was significantly higher if implants had a convex EP compared to a concave or straight EP. Another study showed a significantly higher prevalence of peri-implantitis in implants with a convex EP compared to other EP types, if combined with an EA above 30°.
CONCLUSIONS
Three eligible studies were found. Reported associations should therefore be considered with caution. Synthesis suggests an association between a larger EA (>30°) and a higher prevalence of peri-implantitis or marginal bone loss compared to a smaller EA (<30°). A convex EP may also be associated with a higher prevalence of peri-implantitis. However, causality remains a question.
Topics: Alveolar Bone Loss; Dental Implants; Humans; Peri-Implantitis
PubMed: 35713938
DOI: 10.1002/cre2.594 -
The Journal of Prosthetic Dentistry Dec 2019Immediate loading of dental implants has gained widespread popularity because of its advantages in shortening treatment duration and improving esthetics and patient... (Meta-Analysis)
Meta-Analysis Review
STATEMENT OF PROBLEM
Immediate loading of dental implants has gained widespread popularity because of its advantages in shortening treatment duration and improving esthetics and patient acceptance. However, whether immediate loading can achieve clinical outcomes comparable with those of early or conventional delayed loading is still unclear.
PURPOSE
The purpose of this systematic review and meta-analysis was to compare the efficacy of immediate loading versus early or conventional loading implants in patients rehabilitated with fixed prostheses.
MATERIAL AND METHODS
Electronic searches of CENTRAL, EMBASE, and MEDLINE were supplemented by manual searches up to October 2018. Only human randomized controlled trials (RCTs) comparing immediate with early or conventional loading dental implants were included. Quality assessment was performed by using the Cochrane Collaboration tool. For the meta-analysis, the dichotomous and continuous variables were pooled and analyzed by using risk ratios (RRs) and weighted mean differences (WMDs), with 95% confidence intervals (95% CIs). The outcomes assessed included survival rate, marginal bone level changes, peri-implant gingival level, probing depth, and implant stability. The subgroup analyses included healing methods, implant time, occlusal contact, number of missing teeth, and tooth position.
RESULTS
Thirty-nine trials (49 articles) were included from the initial 763 references evaluated. When compared with conventional loading, with implants regarded as a statistical unit, a statistically significant lower survival rate was observed in the immediate loading dental implant (RR=0.974; 95% CI, 0.954, 0.994; P=.012). Regarding other outcomes, including marginal bone level changes, peri-implant gingival level, probing depth, and implant stability, no statistically significant differences were observed when comparing immediate versus early or conventional loading (P>.05).
CONCLUSIONS
Compared with early loading, immediate loading could achieve comparable implant survival rates and marginal bone level changes. Compared with conventional loading, immediate loading was associated with a higher incidence of implant failure.
Topics: Dental Implantation, Endosseous; Dental Implants; Dental Restoration Failure; Esthetics, Dental; Humans; Immediate Dental Implant Loading; Randomized Controlled Trials as Topic; Time Factors; Tooth Loss
PubMed: 31421892
DOI: 10.1016/j.prosdent.2019.05.013 -
Clinical Oral Investigations Dec 2021The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures... (Review)
Review
OBJECTIVES
The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secondary aim was to verify the effectiveness of IOS procedures based on available prosthodontic outcomes.
MATERIALS AND METHODS
Electronic and manual literature searches were performed to collect evidence concerning the outcomes of IOS and CI performed during the treatment of partially and complete edentulous patients for tooth- or implant-supported restorations. Qualitative analysis was conducted to evaluate the time efficiency and PROMs produced by the two different techniques. Clinical prosthodontic outcomes were analyzed among the included studies when available.
RESULTS
Seventeen studies (9 randomized controlled trials and 8 prospective clinical studies) were selected for qualitative synthesis. The 17 included studies provided data from 430 IOS and 370 CI performed in 437 patients. A total of 7 different IOS systems and their various updated versions were used for digital impressions. The results demonstrated that IOS was overall faster than CI independent of whether quadrant or complete-arch scanning was utilized, regardless of the nature of the restoration (tooth or implant supported). IOS was generally preferred over CI regardless of the size of the scanned area and nature of the restoration (tooth- or implant-supported). Similar prosthodontic outcomes were reported for workflows implementing CI and IOS.
CONCLUSIONS
Within the limitations of this systematic review, IOS is faster than CI, independent of whether a quadrant or complete arch scan is conducted. IOS can improve the patient experience measured by overall preference and comfort and is able to provide reliable prosthodontic outcomes.
CLINICAL RELEVANCE
Reduced procedure working time associated with the use of IOS can improve clinical efficiency and the patient experience during impression procedures. Patient-reported outcome measures (PROMs) are an essential component of evidence-based dental practice as they allow the evaluation of therapeutic modalities from the perspective of the patient. IOS is generally preferred by patients over conventional impressions.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Technique; Humans; Patient Comfort; Prospective Studies; Prosthodontics
PubMed: 34568955
DOI: 10.1007/s00784-021-04157-3 -
International Journal of Environmental... Jun 2020Resolving late failure of dental implant is difficult and costly; however, only few reviews have addressed the risk factors associated with late failure of dental...
Resolving late failure of dental implant is difficult and costly; however, only few reviews have addressed the risk factors associated with late failure of dental implant. The aim of this literature review was to summarize the influences of different potential risk factors on the incidence of late dental implant failure. The protocol of this systematic review was prepared and implemented based on the PRISMA (Preferred reporting items for systematic reviews and meta-analyses) guideline. In December 2018, studies published within the previous 10 years on late dental implant failure were selected by fulfilling the eligibility criteria and the risk factors identified in qualified studies were extracted by using a predefined extraction template. Fourteen eligible studies were assessed. The common risk factors for late failure were divided into three groups according to whether they were related to (1) the patient history (radiation therapy, periodontitis, bruxism and early implant failure), (2) clinical parameters (posterior implant location and bone grade 4) or (3) decisions made by the clinician (low initial stability, more than one implant placed during surgery, inflammation at the surgical site during the first year or using an overdenture with conus-type connection). Clinicians should be cautions throughout the treatment process of dental implant-from the initial examination to the treatment planning, surgical operation and prosthesis selection-in order to minimize the risk of late failure of dental implant.
Topics: Dental Implants; Dental Restoration Failure; Humans; Periodontitis; Research Design; Risk Factors
PubMed: 32498256
DOI: 10.3390/ijerph17113931 -
International Journal of Implant... Oct 2020Immediate implants are frequently employed in the anterior maxillary area. However, the installation of dental implants simultaneously with tooth extraction can also... (Review)
Review
BACKGROUND
Immediate implants are frequently employed in the anterior maxillary area. However, the installation of dental implants simultaneously with tooth extraction can also provide with benefits in the posterior areas with a reduction in time prior the recovery of the masticatory function. Results previously reported in the literature show high-survival and success rates for implants placed in extraction sockets in molar areas; however, this topic has received limited systematic analysis.
MATERIAL AND METHODS
Electronic and manual literature searches were performed by two independent reviewers in several data-bases, including MEDLINE, EMBASE, and Cochrane Oral Health Group Trials Register, for articles up to January 2019 reporting outcomes of immediate implants placed in molar areas. Primary outcomes included survival and success rates, as well as marginal bone loss. Secondary outcomes included the influence of implant position, type of implant connection, grafting protocol, flap or flapless approach, implant diameter, surgical phase, presence of buccal plate, and loading protocol.
RESULTS
Twenty studies provided information on the survival rate, with a total sample of 1.106 implants. The weighted mean survival rate of immediate implants after 1 year of follow-up was 96.6%, and the success rate was 93.3%. On the other hand, marginal bone loss was 1.29 ± 0.24 mm. Secondary outcomes demonstrated that grafting the gap and the loading protocol have an effect on survival and success rates. Similarly, the presence or absence of the buccal bone affect crestal bone levels. Meta-analysis of 4 investigations showed a weighted mean difference of 0.31 mm ± 0.8 IC 95% (0.15-0.46) more marginal bone loss at immediate implant placement versus implants in healed sites (p < 0.001) I = 15.2%.
CONCLUSION
In selected scenarios, immediate implant placement in molar extraction socket might be considered a predictable technique as demonstrated by a high survival and success rates, with minimal marginal bone loss.
PubMed: 32770283
DOI: 10.1186/s40729-020-00235-5 -
Journal of Medical Internet Research Jan 2023The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently developed AR-assisted dental implant navigation system (AR navigation), which uses innovative image technology to directly visualize and track a presurgical plan over an actual surgical site, has attracted great interest.
OBJECTIVE
This study is the first systematic review and meta-analysis study that aimed to assess the accuracy of dental implants placed by AR navigation and compare it with that of the widely used implant placement methods, including the freehand method (FH), template-based static guidance (TG), and conventional navigation (CN).
METHODS
Individual search strategies were used in PubMed (MEDLINE), Scopus, ScienceDirect, Cochrane Library, and Google Scholar to search for articles published until March 21, 2022. This study was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered in the International Prospective Register of Systematic Reviews (PROSPERO) database. Peer-reviewed journal articles evaluating the positional deviations of dental implants placed using AR-assisted implant navigation systems were included. Cohen d statistical power analysis was used to investigate the effect size estimate and CIs of standardized mean differences (SMDs) between data sets.
RESULTS
Among the 425 articles retrieved, 15 articles were considered eligible for narrative review, 8 articles were considered for single-arm meta-analysis, and 4 were included in a 2-arm meta-analysis. The mean lateral, global, depth, and angular deviations of the dental implant placed using AR navigation were 0.90 (95% CI 0.78-1.02) mm, 1.18 (95% CI 0.95-1.41) mm, 0.78 (95% CI 0.48-1.08) mm, and 3.96° (95% CI 3.45°-4.48°), respectively. The accuracy of AR navigation was significantly higher than that of the FH method (SMD=-1.01; 95% CI -1.47 to -0.55; P<.001) and CN method (SMD=-0.46; 95% CI -0.64 to -0.29; P<.001). However, the accuracies of the AR navigation and TG methods were similar (SMD=0.06; 95% CI -0.62 to 0.74; P=.73).
CONCLUSIONS
The positional deviations of AR-navigated implant placements were within the safety zone, suggesting clinically acceptable accuracy of the AR navigation method. Moreover, the accuracy of AR implant navigation was comparable with that of the highly recommended dental implant-guided surgery method, TG, and superior to that of the conventional FH and CN methods. This review highlights the possibility of using AR navigation as an effective and accurate immersive surgical guide for dental implant placement.
Topics: Humans; Augmented Reality; Dental Implants; Surgery, Computer-Assisted; Surgeons; Technology
PubMed: 36598798
DOI: 10.2196/42040 -
International Journal of Environmental... Feb 2022The aim of this systematic review was to evaluate the in vitro accuracy of dental implants impressions taken with intraoral scanner compared with impressions taken with... (Review)
Review
The aim of this systematic review was to evaluate the in vitro accuracy of dental implants impressions taken with intraoral scanner compared with impressions taken with conventional techniques. Two independent reviewers conducted a systematic electronic search in the PubMed, Web of Science and Scopus databases. Some of the employed key terms, combined with the help of Boolean operators, were: "dental implants", "impression accuracy", "digital impression" and "conventional impression". Publication dates ranged from the earliest article available until 31 July 2021. A total of 26 articles fulfilled the inclusion criteria: 14 studies simulated complete edentation (CE), nine partial edentation (PE) and only two simulated a single implant (SI); One study simulated both CE and SI. In cases of PE and SI, most of the studies analyzed found greater accuracy with conventional impression (CI), although digital impression (DI) was also considered adequate. For CE the findings were inconclusive as six studies found greater accuracy with DI, five found better accuracy with CI and four found no differences. According to the results of this systematic review, DI is a valid alternative to CI for implants in PE and SI, although CI appear to be more accurate. For CE the findings were inconclusive, so more studies are needed before DI can be recommended for all implant-supported restorations.
Topics: Computer-Aided Design; Databases, Factual; Dental Implants; Dental Impression Technique; Models, Dental
PubMed: 35206217
DOI: 10.3390/ijerph19042026 -
International Journal of Implant... Jul 2023The purpose of this systematic review was to assess the evidence regarding the indications for placement of zygomatic implants to rehabilitate edentulous maxillae. (Review)
Review
PURPOSE
The purpose of this systematic review was to assess the evidence regarding the indications for placement of zygomatic implants to rehabilitate edentulous maxillae.
MATERIAL AND METHODS
A focused question using the PIO format was developed, questioning "in patients in need of an implant-supported rehabilitation of the edentulous maxillae, what are the indications for the use of zygomatic implants''. The primary information analyzed and collected was a clear description of the indication for the use of zygomatic implants.
RESULTS
A total of 1266 records were identified through database searching. The full-text review was conducted for 117 papers, and 10 were selected to be included in this review. Zygomatic implant indications were extreme bone atrophy or deficiency secondary to different factors. The quad zygoma concept (two zygomatic implants bilaterally placed and splinted) was applied to 107 patients, the classic zygoma concept (one zygomatic implant bilaterally placed and splinted to standard anterior implants) was used in 88 patients, and the unilateral concept (one zygomatic implant on one side, splinted with one or more conventional implants) was employed in 14 patients.
CONCLUSIONS
The main indication for the use of zygomatic implants was considered extreme maxillary bone atrophy, resulting from many factors. The clear definition of what was considered "extreme bone atrophy" is not uniquely defined in each paper. Further studies are needed to develop clear indications for zygomatic implants.
Topics: Humans; Dental Implants; Atrophy; Databases, Factual; Medicine; Mouth, Edentulous
PubMed: 37391575
DOI: 10.1186/s40729-023-00480-4 -
Clinical Oral Investigations Oct 2021This systematic review assesses dental implant survival, calculates the incidence rate of osteoradionecrosis, and evaluates risk factors in irradiated head and neck... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
This systematic review assesses dental implant survival, calculates the incidence rate of osteoradionecrosis, and evaluates risk factors in irradiated head and neck cancer patients.
MATERIALS AND METHODS
Various databases (e.g., Medline/Embase using Ovid) and gray literature platforms were searched using a combination of keywords and subject headings. When appropriate, meta-analysis was carried out using a random effects model. Otherwise, pooled analysis was applied.
RESULTS
A total of 425 of the 660 included patients received radiotherapy. In total, 2602 dental implants were placed, and 1637 were placed in irradiated patients. Implant survival after an average follow-up of 37.7 months was 97% (5% confidence interval, CI 95.2%, 95% CI 98.3%) in nonirradiated patients and 91.9% (5% CI 87.7%, 95% CI: 95.3%) after an average follow-up of 39.8 months in irradiated patients. Osteoradionecrosis occurred in 11 cases, leading to an incidence of 3% (5% CI 1.6%, 95% CI 4.9%). The main factors impacting implant survival were radiation and grafting status, while factors influencing osteoradionecrosis could not be determined using meta-analysis.
CONCLUSION
Our data show that implant survival in irradiated patients is lower than in nonirradiated patients, and osteoradionecrosis is-while rare-a serious complication that any OMF surgeon should be prepared for. The key to success could be a standardized patient selection and therapy to improve the standard of care, reduce risks and shorten treatment time.
CLINICAL RELEVANCE
Our analysis provides further evidence that implant placement is a feasible treatment option in irradiated head and neck cancer patients with diminished oral function and good long-term cancer prognosis.
Topics: Dental Implantation, Endosseous; Dental Implants; Head and Neck Neoplasms; Humans; Osteoradionecrosis
PubMed: 34401944
DOI: 10.1007/s00784-021-04065-6 -
Clinical Oral Implants Research Jan 2022To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants.
MATERIALS AND METHODS
Based on a focused question and customized PICO framework, electronic (Medline/EMBASE/Cochrane) and manual searches for studies reporting the clinical outcomes of all-ceramic SCs and FDPs supported by ceramic implants ≥12 months were performed. The primary outcomes were reconstruction survival and the chipping proportion. The secondary outcomes were implant survival, technical complications, and patient-related outcome measurements. Meta-analyses were performed after 1, 2, and 5 years using random-effect meta-analyses.
RESULTS
Eight of the 1,403 initially screened titles and 55 full texts were included. Five reported on monolithic lithium disilicate (LS2) SCs, one on veneered zirconia SCs, and two on veneered zirconia SCs and FDPs, which reported all on cement-retained reconstructions (mean observation: 12.0-61.0 months). Meta-analyses estimated a 5-year survival rate of 94% (95% confidence interval [CI]: 82%-100%) for overall implant survival. Reconstruction survival proportions after 5 years were: monolithic LS2, 100% (95%CI: 95%-100%); veneered zirconia SCs, 89% (95%CI: 62%-100%); and veneered zirconia FDPs 94% (95%CI: 81%-100%). The chipping proportion after 5 years was: monolithic LS2, 2% (95%CI: 0%-11%); veneered zirconia SCs, 38% (95%CI: 24%-54%); and veneered zirconia FDPs, 57% (95%CI: 38%-76%). Further outcomes were summarized descriptively.
CONCLUSIONS
Due to the limited data available, only tendencies could be identified. All-ceramic reconstructions supported by ceramic implants demonstrated promising survival rates after mid-term observation. However, high chipping proportions of veneered zirconia SCs and, particularly, FDPs diminished the overall outcome. Monolithic LS2 demonstrated fewer clinical complications. Monolithic reconstructions could be a valid treatment option for ceramic implants.
Topics: Ceramics; Crowns; Dental Implants; Dental Porcelain; Dental Prosthesis Design; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Humans; Metal Ceramic Alloys; Zirconium
PubMed: 34665900
DOI: 10.1111/clr.13871