-
Gels (Basel, Switzerland) Mar 2022Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to... (Review)
Review
Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to delayed dentin sealing (DDS), a technique in which hybridization is performed following the provisional phase and just before the indirect restoration luting procedure. This study aimed to compare the bond strength of restorations to dentin of the IDS and the DDS techniques throughout a systematic review and meta-analysis. The following PICOS framework was used: population, indirect restorations; intervention, IDS; control, DDS; outcomes, bond strength; and study design, in vitro studies. PubMed (MedLine), The Cochrane Library, ISI Web of Science, Scielo, Scopus, and Embase were screened up to January 2022 by two reviewers (L.H. and R.B.). In vitro papers studying the bond strength to human dentin of the IDS technique compared to the DDS technique were considered. Meta-analyses were carried out by using a software program (Review Manager v5.4.1; The Cochrane Collaboration). Comparisons were made by considering the adhesive used for bonding (two-step etch-and-rinse, three step etch-and-rinse, one-step self-etch, two-step self-etch, and universal adhesives). A total of 3717 papers were retrieved in all databases. After full-text assessment, 22 potentially eligible studies were examined for qualitative analysis, leaving a total of 21 articles for the meta-analysis. For the immediate bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p < 0.001). Taking into account the subgroup analysis, it seems that the use of the IDS technique with a two-step etch-and-rinse or a one-step self-etch adhesive system does not represent any advantage over the DDS technique (p = 0.07, p = 0.15). On the other hand, for the aged bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p = 0.001). The subgroups analysis shows that this improvement is observed only when a three-step etch-and-rinse adhesive system (p < 0.001) or when a combination of an adhesive system plus a layer of flowable resin (p = 0.01) is used. The in vitro evidence suggests that the use of the IDS technique improves the bond strength of dentin to resin-based restorations regardless of the adhesive strategy used. The use of a three-step etch-and-rinse adhesive system or the combination of an adhesive system plus a layer of flowable resin seems to considerably enhance the bond strength in the long term.
PubMed: 35323288
DOI: 10.3390/gels8030175 -
Clinical Oral Investigations Dec 2021The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures... (Review)
Review
OBJECTIVES
The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secondary aim was to verify the effectiveness of IOS procedures based on available prosthodontic outcomes.
MATERIALS AND METHODS
Electronic and manual literature searches were performed to collect evidence concerning the outcomes of IOS and CI performed during the treatment of partially and complete edentulous patients for tooth- or implant-supported restorations. Qualitative analysis was conducted to evaluate the time efficiency and PROMs produced by the two different techniques. Clinical prosthodontic outcomes were analyzed among the included studies when available.
RESULTS
Seventeen studies (9 randomized controlled trials and 8 prospective clinical studies) were selected for qualitative synthesis. The 17 included studies provided data from 430 IOS and 370 CI performed in 437 patients. A total of 7 different IOS systems and their various updated versions were used for digital impressions. The results demonstrated that IOS was overall faster than CI independent of whether quadrant or complete-arch scanning was utilized, regardless of the nature of the restoration (tooth or implant supported). IOS was generally preferred over CI regardless of the size of the scanned area and nature of the restoration (tooth- or implant-supported). Similar prosthodontic outcomes were reported for workflows implementing CI and IOS.
CONCLUSIONS
Within the limitations of this systematic review, IOS is faster than CI, independent of whether a quadrant or complete arch scan is conducted. IOS can improve the patient experience measured by overall preference and comfort and is able to provide reliable prosthodontic outcomes.
CLINICAL RELEVANCE
Reduced procedure working time associated with the use of IOS can improve clinical efficiency and the patient experience during impression procedures. Patient-reported outcome measures (PROMs) are an essential component of evidence-based dental practice as they allow the evaluation of therapeutic modalities from the perspective of the patient. IOS is generally preferred by patients over conventional impressions.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Technique; Humans; Patient Comfort; Prospective Studies; Prosthodontics
PubMed: 34568955
DOI: 10.1007/s00784-021-04157-3 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case...
PURPOSE
This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.
STUDY SELECTION
We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis. We report evidence from clinical papers and case reports, digital impression-taking methods, and maxillomandibular relationship (MMR) records.
RESULTS
A case report electronically published in 2019 introduced a clasp-retained RPD fabricated via a full-digital workflow without a gypsum definitive cast. Computer-aided design and computer-aided manufacturing of double-crown-retained RPDs with nonmetal materials were described in some case reports. Intraoral scanners were used to obtain digital impressions and MMR records in the fabrication of digital RPDs, which have potential advantages for reducing the number of clinical appointments and simplifying laboratory procedures. Evidence from clinical trials is scarce; a randomized controlled trial reported higher patient satisfaction with digital clasp-retained RPDs than with conventional RPDs.
CONCLUSIONS
Full-digital RPDs can be fabricated without a gypsum definitive cast. However, the indication for full-digital RPDs is limited to cases with Kennedy Class III/IV partially edentulous arches with several missing teeth. Challenges in digital impression-taking and MMR recording remain to be solved to extend these indications. More evidence from clinical trials is required to evaluate the efficacy and usefulness of digital RPDs.
Topics: Computer-Aided Design; Denture, Partial, Removable; Humans; Mouth, Edentulous; Randomized Controlled Trials as Topic
PubMed: 33504721
DOI: 10.2186/jpr.JPR_D_20_00116 -
The Journal of Prosthetic Dentistry Sep 2023Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are... (Review)
Review
STATEMENT OF PROBLEM
Digital workflows for digital complete denture fabrication have a variety of clinical and laboratory procedures, but their outcomes and associated complications are currently unknown.
PURPOSE
The purpose of this systematic review was to evaluate the clinical and laboratory procedures for digital complete dentures, their outcomes, and associated complications.
MATERIAL AND METHODS
Electronic literature searches were conducted on PubMed/Medline, Embase, and Web of Science for studies published from January 2000 to September 2022 and screened by 2 independent reviewers. Information on digital complete denture procedures, materials, their outcomes, and associated complications was extracted.
RESULTS
Of 266 screened studies, 39 studies were included. While 26 assessed definitive complete dentures, 7 studies assessed denture bases, 2 assessed trial dentures, and 4 assessed the digital images only. Twenty-four studies used border molded impression technique, 3 studies used a facebow record, and 7 studies used gothic arch tracing. Only 13 studies performed trial denture placement. Twenty-one studies used milling, and 17 studies used 3D printing for denture fabrication. One study reported that the retention of maxillary denture bases fabricated from a border-molded impression (14.5 to 16.1 N) was statistically higher than the retention of those fabricated from intraoral scanning (6.2 to 6.6 N). The maximum occlusal force of digital complete denture wearers was similar across different fabrication procedures. When compared with the conventional workflow, digital complete dentures required statistically shorter clinical time with 205 to 233 minutes saved. Up to 37.5% of participants reported loss of retention and up to 31.3% required a denture remake. In general, ≥1 extra visit and 1 to 4 unscheduled follow-up visits were needed. The outcomes for patient satisfaction and oral health-related quality of life were similar between conventional, milled, and 3D-printed complete dentures.
CONCLUSIONS
Making a border-molded impression is still preferred for better retention, and trial denture placement is still recommended to optimize the fabrication of definitive digital complete dentures.
PubMed: 37689573
DOI: 10.1016/j.prosdent.2023.07.027 -
Journal of Clinical and Experimental... Aug 2020This systematic review aimed to evaluate the efficiency and accuracy of digital impression techniques for implant-supported restorations, and to assess their economic... (Review)
Review
BACKGROUND
This systematic review aimed to evaluate the efficiency and accuracy of digital impression techniques for implant-supported restorations, and to assess their economic feasibility.
MATERIAL AND METHODS
Two independent electronic database searches were conducted in the Pubmed/MedLine, Cochrane Library, and Lilacs databases complimented by a manual search, selecting relevant clinical and studies published between 1st January 2009 and 28st February 2019. All type of studies ( and ) were included in this systematic review.
RESULTS
Twenty-seven studies (8 and 19 studies) fulfilled the inclusion criteria. No meta-analysis was performed due to a large heterogeneity of the study protocols. The passive fit of superstructures on dental implants presented similar results between digital and conventional impression techniques. The studies considered that several factors influence the accuracy of implant impression taking: distance and angulation between implants, depth of placement, type of scanner, scanning strategy, characteristics of scanbody, and operator experience. Regarding the economic viability of intraoral scanning systems, only one study reported any benefit in comparison with conventional techniques.
CONCLUSIONS
Digital impressions of dental implants can be considered a viable alternative in cases of one or two contiguous dental implants. However, more studies are needed to evaluate the accuracy of digital techniques in full-arch implant-supported restorations. Intraoral scanner, dental implant, prosthesis, misfit, systematic review.
PubMed: 32913577
DOI: 10.4317/jced.57025 -
The Saudi Dental Journal Jul 2023Lithium disilicate glass-ceramic (LDC) restorations exhibit microorganism infiltration, recurrent caries, pulpal lesions, periodontal inflammation, and cement exposure... (Review)
Review
INTRODUCTION
Lithium disilicate glass-ceramic (LDC) restorations exhibit microorganism infiltration, recurrent caries, pulpal lesions, periodontal inflammation, and cement exposure to the oral environment over time. All these factors lead to restoration failure. This systematic review aimed to investigate the clinical outcomes of LDC full-coverage crowns (FCC) in permanent teeth compared with those of other full-coverage restoration materials.
MATERIALS & METHODS
Search strategies were developed for four databases: Web of Science, OVID, PubMed, and Scopus. Data extraction and quality appraisals were performed by two independent reviewers. Data on the presence of caries, post-operative sensitivity, and periodontal changes were extracted from the included clinical studies. In addition to the outcome measures, data on the sample size, study groups, method of restoration fabrication, type of impression, and type of abutment were recorded.
RESULTS
We retrieved 3989 records for the title and abstract screening. Of these, 19 clinical studies met the inclusion criteria. The overall quality of the included studies indicates a low risk of bias. Most studies reported no pulpal involvement, recurrent caries, or post-operative sensitivity and presented a favorable periodontal response after the cementation of LDC-FCC during different follow-up periods.
CONCLUSION
Based on the endodontic and periodontic clinical responses of natural tooth abutments and their supporting periodontium, LDC-FCC can be considered a clinically successful restorative option.
PubMed: 37520610
DOI: 10.1016/j.sdentj.2023.05.012 -
Bioengineering (Basel, Switzerland) Mar 2022Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants... (Review)
Review
Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants are used; however, no sole disinfectant can be designated as universal for all the impression materials. Thus, the aim of this study is to systemically review the literature to evaluate the effect of the existing disinfection procedures on the bacterial colonization of dental impression materials. This systematic review and meta-analysis was conducted according to the PRISMA statement. PubMed (MEDLINE), Web of Science, Scopus, EMBASE, and SciELO databases were screened up to April 2021. Eligibility criteria included in vitro studies reporting the antibacterial activity of disinfectant solutions in dental impression materials. The meta-analysis was performed using Review Manager (version 5.3.5). A global comparison was performed with the standardized mean difference based on random-effect models at a significance level of α = 0.05. A total of seven studies were included in the meta-analysis. The included studies described the effect of disinfection processes with chlorhexidine gluconate, alcohol, sodium hypochlorite, glutaraldehyde, and hydrogen peroxide in alginate, polyvinyl siloxane, and polyether impression materials. The meta-analyses showed that the use of chlorhexidine, alcohol, glutaraldehyde, and sodium hypochlorite reduced the colony-forming units by a milliliter (CFU/mL) in alginate (p < 0.001). On the other hand, glutaraldehyde, sodium hypochlorite, and alcohol reduced the CFU/mL in polyvinyl siloxane (p < 0.001). Finally, alcohol and glutaraldehyde reduced the CFU/mL in polyether material (p < 0.001). High heterogenicity was observed for the alginate and polyvinyl siloxane materials (I2 = 74%; I2 = 90%). Based on these in vitro studies, the disinfection of impression materials with several disinfection agents reduces the CFU/mL count.
PubMed: 35324812
DOI: 10.3390/bioengineering9030123 -
Frontiers in Pediatrics 2023The aim of this systematic review is to evaluate the perception of the patient, the chairside time, and the reliability and/or reproducibility of intraoral scanners for... (Review)
Review
PURPOSE
The aim of this systematic review is to evaluate the perception of the patient, the chairside time, and the reliability and/or reproducibility of intraoral scanners for full arch in pediatric patients.
METHODS
A data search was performed in four databases (Medline-Pubmed, Scopus, ProQuest and Web of Science) in accordance with the PRISMA 2020 statements. Studies were classified in three categories (patient perception, scanning or impression time and reliability and/or reproducibility). The resources, the data extraction and the quality assessment were carried out independently by two operators. The variables recorded were population characteristics, material and methods aspects and included country, study design and main conclusion. A quality assessment of the selected studies was performed with QUADAS-2 tool, and Kappa-Cohen Index was calculated to analyze examiner agreement.
RESULTS
The initial search obtained 681 publications, and finally four studies matching inclusion criteria were selected. The distribution of the studies in the categories was three for the analysis of the patient's perception and scanning or impression time; and two items to assess the reliability and/or reproducibility of intraoral scans. All included studies have a repeated measures-transversal design. The sample size ranged between 26 and 59 children with a mean age. The intraoral scanners evaluated were Lava C.O.S, Cerec Omnicam, TRIOS Classic, TRIOS 3-Cart and TRIOS Ortho. The quality assessment of the studies using QUADAS-2 tool revealed a low risk of bias while evaluating patient perception, but an unclear risk of bias in the analysis of accuracy or chairside time. In relation to the applicability concerns, the patient selection was of high risk of bias. All studies agreed that the patient perception and comfort is better with intraoral scanners in comparison with the conventional method. The accuracy or reliability of the digital procedure is not clear, being clinically acceptable. In relation with the chairside time, it depends on the intraoral scanner, with contradictory data in the different analyzed studies.
CONCLUSION
The use of intraoral scanners in children is a favorable option, finding a significantly higher patient perception and comfort with intraoral scanners compared to the conventional impression method. The evidence for reliability or reproducibility is not strong to date, however, the differences between the intraoral measurements and the digital models would be clinically acceptable.
PubMed: 37435173
DOI: 10.3389/fped.2023.1213072 -
The Saudi Dental Journal May 2020The objective of this systematic review and meta-analysis study was to identify the different disinfection methods and materials and the existing evidence on their... (Review)
Review
Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study.
OBJECTIVES
The objective of this systematic review and meta-analysis study was to identify the different disinfection methods and materials and the existing evidence on their effect on properties of the different impression materials.
MATERIAL AND METHODS
An electronic search of MEDLINE (PubMed), Science Direct, and Google Scholar databases was performed to retrieve related English-language articles published between January 2000 and July 2019. Available studies with search terms such as: Impression disinfection, disinfection method, impression dimensional stability and impression wettability were used. The selected articles were reviewed by screening their titles and abstracts and full text. Finally, a total of 70 articles were considered relevant and were included in this study.
RESULTS
Extensive studies were conducted to determine the effect of the different disinfection methods and materials on the properties of the different impression materials such as dimensional stability, wettability and surface roughness. While some studies reported significant changes in the properties of the impression materials, others reported either no changes or minor insignificant effects.
CONCLUSIONS
Some studies reported significant changes in the properties of the impression materials as a result of using different disinfection methods, whereas others reported either minor insignificant or no changes. Although the findings of the studies were controversial, care should be taken to avoid distortion of impressions and loss of their surface details that can adversely affect the fitting accuracy of the restorations. Therefore, better designed and standardized studies are needed to evaluate the effect of different commonly used disinfectants on properties of impression materials. Moreover, manufacturers should be encouraged to recommend specific disinfection methods and materials for disinfecting the impression materials to ensure their optimal accuracy.
PubMed: 32405219
DOI: 10.1016/j.sdentj.2019.12.003 -
Biomimetics (Basel, Switzerland) Mar 2024The popular immediate dentin sealing (IDS) technique is used to improve the bond strength of indirect restorations. This systematic review assessed whether bond strength... (Review)
Review
The popular immediate dentin sealing (IDS) technique is used to improve the bond strength of indirect restorations. This systematic review assessed whether bond strength is affected by the type of aging conditions, bonding agents, flowable resin composites, impression materials, temporary materials, and/or resin cement used within the IDS procedure. A comprehensive database search of PubMed, Embase, Scopus, Ovid Medline, Web of Sciences, Cochrane Library, Dentistry & Oral Sciences Source, and ProQuest was carried out up to 30 January 2024 without publication year or language limitations. Only in vitro full-texts regarding the effect of IDS on bond strength were included, and the quality of their methods was assessed via a Risk of Bias (RoB) test. In total, 1023 pertinent studies were initially found, and 60 articles were selected for review after screening for the title, abstract, and full texts. IDS application improves the bond strength of indirect restorations to dentin and reduces the negative effects of temporary materials on the bond durability of final indirect restorations. Filled dentin bonding agents or combinations with flowable resin composite are preferred to protect the IDS layer from conditioning procedures.
PubMed: 38534867
DOI: 10.3390/biomimetics9030182