-
Journal of Conservative Dentistry : JCD 2022Advances in adhesive technologies and escalation in esthetic demands have increased indications for tooth-colored, partial coverage restorations. Recently, material... (Review)
Review
BACKGROUND
Advances in adhesive technologies and escalation in esthetic demands have increased indications for tooth-colored, partial coverage restorations. Recently, material knowledge has evolved, new materials have been developed, and no systematic review has answered the question posed by practitioners: Is the clinical efficacy of resin or ceramic better, for inlay, onlay, and overlay in the long run?
AIM
The aim of this systematic review and meta-analysis was to evaluate the clinical performance of ceramic and resin inlays, onlays, and overlays and to identify the complication types associated with the main clinical outcomes.
MATERIALS AND METHODS
Two reviewers (VN and AJ) searched PubMed, Embase, and Cochrane Central registry of controlled trials for published articles between 1983 and 2020 conforming to Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines for systematic reviews. Only clinical studies which met the following criteria were included (1) studies regarding ceramic and resin inlays, onlays, and overlays were included; (2) randomized controlled trials, retrospective or prospective studies conducted in humans; (3) studies with a dropout rate <50% 4) studies with a follow-up higher than 5 years.
RESULTS
Of 1718 articles, 21 articles were selected. At 5 years, the estimated survival rates for resin ( = 129) was 86%, feldspathic porcelain ( = 1048) was 90%, and glass ceramic ( = 2218) was 92%; at 10 years, the survival of resin was 75% ( = 115), feldspathic porcelain was 91% ( = 1829), and glass ceramic was 89% ( = 1075).
CONCLUSION
The meta-regression indicated that ceramic partial coverage restorations (feldspathic porcelain and glass-ceramic) outperformed resin partial coverage restorations both at 5-year and 10-year follow-up. When compared between ceramic types, glass ceramics outperformed feldspathic porcelain at 5 years' follow-up and feldspathic porcelain outperformed glass ceramics at 10 years' follow-up. The failures were mostly due to fractures (6.2%), endodontic problems (3%), secondary caries (1.7%), and debonding which was 0.9%.
PubMed: 36187858
DOI: 10.4103/jcd.jcd_184_22 -
Clinical Oral Implants Research Jan 2022To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants.
MATERIALS AND METHODS
Based on a focused question and customized PICO framework, electronic (Medline/EMBASE/Cochrane) and manual searches for studies reporting the clinical outcomes of all-ceramic SCs and FDPs supported by ceramic implants ≥12 months were performed. The primary outcomes were reconstruction survival and the chipping proportion. The secondary outcomes were implant survival, technical complications, and patient-related outcome measurements. Meta-analyses were performed after 1, 2, and 5 years using random-effect meta-analyses.
RESULTS
Eight of the 1,403 initially screened titles and 55 full texts were included. Five reported on monolithic lithium disilicate (LS2) SCs, one on veneered zirconia SCs, and two on veneered zirconia SCs and FDPs, which reported all on cement-retained reconstructions (mean observation: 12.0-61.0 months). Meta-analyses estimated a 5-year survival rate of 94% (95% confidence interval [CI]: 82%-100%) for overall implant survival. Reconstruction survival proportions after 5 years were: monolithic LS2, 100% (95%CI: 95%-100%); veneered zirconia SCs, 89% (95%CI: 62%-100%); and veneered zirconia FDPs 94% (95%CI: 81%-100%). The chipping proportion after 5 years was: monolithic LS2, 2% (95%CI: 0%-11%); veneered zirconia SCs, 38% (95%CI: 24%-54%); and veneered zirconia FDPs, 57% (95%CI: 38%-76%). Further outcomes were summarized descriptively.
CONCLUSIONS
Due to the limited data available, only tendencies could be identified. All-ceramic reconstructions supported by ceramic implants demonstrated promising survival rates after mid-term observation. However, high chipping proportions of veneered zirconia SCs and, particularly, FDPs diminished the overall outcome. Monolithic LS2 demonstrated fewer clinical complications. Monolithic reconstructions could be a valid treatment option for ceramic implants.
Topics: Ceramics; Crowns; Dental Implants; Dental Porcelain; Dental Prosthesis Design; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Humans; Metal Ceramic Alloys; Zirconium
PubMed: 34665900
DOI: 10.1111/clr.13871 -
Clinical and Experimental Dental... Dec 2022This systematic review aims to investigate the effect of different preparation designs on the marginal fit and fracture strength of ceramic occlusal veneers. (Review)
Review
OBJECTIVES
This systematic review aims to investigate the effect of different preparation designs on the marginal fit and fracture strength of ceramic occlusal veneers.
MATERIALS AND METHODS
Based on the PICO question and the search terms, an electronic search was performed in Google Scholar, PubMed (MEDLINE), Scopus, Cochrane Library, Web of Science, Science Direct, Wiley, Ovid, and SAGE for articles published up to July 2022. After including English in vitro studies that evaluated posterior ceramic occlusal overlays at the posterior with ceramic restorations by following the PRISMA statement, the extracted data was tabulated. The methodological quality of the included studies was evaluated. Risk of bias assessment was done independently by two authors using the modified MINORS scale.
RESULTS
About 3138 search results were screened, of which 22 were selected due to their titles. Twenty-one full-text articles were assessed for eligibility. Seventeen in-vitro studies were finalized for the extraction of quantitative data. All 17 articles had a low risk of bias and were retained. The influencing items for evaluating the research were different in most studies; therefore, qualitative synthesis of the results was feasible. They generally included preparation design, material thickness, depth of preparation in the tooth, internal divergence angle, and finish line. Meta-analysis was not done due to heterogeneity of preparation types and evaluation methods. Results revealed that fracture resistance of occlusal veneers is higher than normal mastication force, and it is sufficient to prepare the occlusal surface, use a self-etching primer for bonding, and an acceptable minimum ceramic thickness. The marginal discrepancy of occlusal veneers is clinically acceptable. However, this systematic review faces some limitations due to the lack of in vivo studies, different preparation designs in included studies, different follow-ups, and lack of comprehensive explanations in articles.
CONCLUSIONS
The preparation design of occlusal veneers influences both marginal adaptation and fracture resistance. Various preparation designs are proven to have clinically acceptable fracture strength and marginal adaptation.
Topics: Dental Porcelain; Dental Veneers; Flexural Strength; Dental Stress Analysis; Materials Testing; Ceramics
PubMed: 36062841
DOI: 10.1002/cre2.653 -
Cureus Nov 2022This study aimed to systematically review the literature to evaluate the marginal adaptation of veneers using different fabrication methods, namely, conventional... (Review)
Review
This study aimed to systematically review the literature to evaluate the marginal adaptation of veneers using different fabrication methods, namely, conventional feldspathic porcelain laminate veneers (PLVs), computer-aided design-computer-aided machining (CAD-CAM) veneers, and pressed veneers. A comprehensive literature search was performed using electronic databases (PubMed and Google Scholar) as well as hand searches to identify all relevant studies related to veneers and marginal adaptation. The identified studies were screened for assessing the inclusion and exclusion criteria. The included articles were then subjected to data extraction and analysis. The search resulted in 130 articles, of which six were included in this systematic review. All included articles were assessed for adaptation of margins. Based on the findings of this systematic review, no significant differences were found in the marginal adaptation of CAD-CAM and conventional feldspathic PLVs. The marginal fidelity of ceramic veneers issuing from the various fabrication techniques was clinically acceptable.
PubMed: 36579272
DOI: 10.7759/cureus.31885 -
Journal of Clinical Medicine Nov 2022This systematic review and meta-analysis aimed to evaluate the wear of the antagonist tooth in ceramic restorations. (Review)
Review
BACKGROUND
This systematic review and meta-analysis aimed to evaluate the wear of the antagonist tooth in ceramic restorations.
MATERIAL AND METHODS
This study was carried out based on Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) recommendations; it was also registered in PROSPERO (register number: CRD42022316252). Three databases were consulted in the literature search, Embase, Scopus, and Web of Science. The citation searching was conducted by two researchers independently. The clinical studies that evaluated wear in antagonist teeth concerning ceramic restoration were included. Twelve articles were selected after eliminating duplicates ones and applying the inclusion criteria, and two were chosen through citation. Fourteen articles were considered for the qualitative and quantitative analysis (meta-regression and meta-analysis).
RESULTS
The mean linear wear of the antagonist tooth in relation to feldspathic was 8.914 μm, for lithium disilicate it was 0.018 μm, and for zirconia it was 0.257 μm. The mean volumetric wear of the antagonist tooth in relation to feldspathic was 0.273 mm, for hybrid ceramic it was 0.030 mm, for lithium disilicate it was 0.018 mm, and for zirconia it was 0.014 mm. The mean natural tooth wear was 0.7974 μm per month. Tooth wear caused by zirconia at six months was 31.755 μm, at 12 months it was 24.648 μm, and at 24 months it was 20.662 μm.
CONCLUSIONS
Feldspathic produces greater wear of the antagonist tooth from ceramic restorations linearly and volumetrically. In addition, zirconia generates the least wear that will decrease over time, and it will be equal to or less than the natural wear in the tooth.
PubMed: 36362777
DOI: 10.3390/jcm11216547 -
Journal of Applied Biomaterials &... 2024Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs)... (Review)
Review
Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.
Topics: Humans; Ceramics; Resin Cements; Dental Porcelain; Dental Prosthesis, Implant-Supported; Denture, Partial, Fixed, Resin-Bonded; Zirconium
PubMed: 38706266
DOI: 10.1177/22808000241250118 -
Clinical Oral Investigations Sep 2023The aim of this systematic review and meta-analysis is to assess the comparative clinical success and survival of intracoronal indirect restorations using gold, lithium... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The aim of this systematic review and meta-analysis is to assess the comparative clinical success and survival of intracoronal indirect restorations using gold, lithium disilicate, leucite, and indirect composite materials.
MATERIAL AND METHODS
This systematic review and meta-analysis were conducted following the Cochrane Handbook for Systematic Reviews of Interventions and PRISMA guidelines. The protocol for this study was registered in PROSPERO (registration number: CRD42021233185). A comprehensive literature search was conducted across various databases and sources, including PubMed/Medline, Embase, Cochrane Library, Web of Science, ClinicalTrials.gov, and gray literature. A total of 7826 articles were screened on title and abstract. Articles were not excluded based on the vitality of teeth, the language of the study, or the observation period. The risk difference was utilized for the analyses, and a random-effects model was applied. All analyses were conducted with a 95% confidence interval (95% CI). The calculated risk differences were derived from the combined data on restoration survival and failures obtained from each individual article. The presence of heterogeneity was assessed using the I statistic, and if present, the heterogeneity of the data in the articles was evaluated using the non-parametric chi-squared statistic (p < 0.05).
RESULTS
A total of 12 eligible studies were selected, which included 946 restorations evaluated over a minimum observation period of 1 year and a maximum observation period of 7 years. Results of the meta-analysis indicated that intracoronal indirect resin composite restorations have an 18% higher rate of failure when compared to intracoronal gold restorations over 5-7 years of clinical service (risk difference = - 0.18 [95% CI: - 0.27, - 0.09]; p = .0002; I = 0%). The meta-analysis examining the disparity in survival rates between intracoronal gold and leucite restorations could not be carried out due to methodological differences in the studies.
CONCLUSIONS
According to the currently available evidence, medium-quality data indicates that lithium disilicate and indirect composite materials demonstrate comparable survival rates in short-term follow-up. Furthermore, intracoronal gold restorations showed significantly higher survival rates, making them a preferred option over intracoronal indirect resin-composite restorations. Besides that, the analysis revealed no statistically significant difference in survival rates between leucite and indirect composite restorations. The short observation period, limited number of eligible articles, and low sample size of the included studies were significant limitations.
CLINICAL SIGNIFICANCE
Bearing in mind the limitations of the reviewed literature, this systematic review and meta-analysis help clinicians make evidence-based decisions on how to restore biomechanically compromised posterior teeth.
Topics: Dental Porcelain; Aluminum Silicates; Composite Resins; Gold
PubMed: 37597003
DOI: 10.1007/s00784-023-05050-x -
European Journal of Dentistry May 2021The aim of this systematic review was to analyze and compare the most up-to-date information available on long-term, medium-term, and short-term survival rates of...
The aim of this systematic review was to analyze and compare the most up-to-date information available on long-term, medium-term, and short-term survival rates of porcelain laminate veneers (PLVs) and investigate the homogeneity in current studies or lack of it. An electronic search was performed using PubMed, Ovid MEDLINE, Cochrane Library, Web of Science, EBSCO, Science Direct, Wiley, and Scopus databases. Based on the PRISMA guidelines, the main inclusion criteria consisted of research articles published after the year 2000, studies with a follow-up period of at least 1 year and reporting of the Kaplan-Meier estimated cumulative survival rates. Quality assessment of the included studies was performed using the modified systematic assessment list consisting of 24 items. Thirty full-text articles were reviewed in detail. A total of 30 articles met the inclusion criteria and were selected for qualitative synthesis. The remaining 27 publications were retained to discuss the heterogeneity in the current literature and reported longevity of veneer restorations. A conclusive estimation of the longevity of PLVS beyond 20 years is lacking. The availability of evidence in the current literature is limited in terms of sample size and duration of follow-up. However, the majority of studies have concluded that PLVs have high-success rates and predictable patient outcomes. The present literature indicates an increased heterogeneity among research study designs. Researchers should aim for homogeneous study designs that can be included in systematic reviews and meta-analyses.
PubMed: 33003243
DOI: 10.1055/s-0040-1715914 -
Dental Research Journal 2022It is a major concern to select a proper ceramic with acceptable strength and esthetic and minimum antagonist wear. Therefore, different ceramics were introduced to... (Review)
Review
It is a major concern to select a proper ceramic with acceptable strength and esthetic and minimum antagonist wear. Therefore, different ceramics were introduced to obtain these advantages with various surface treatments. The aim of this study is to evaluate and report the wear behavior of polished and glazed feldspathic and zirconia crowns in published articles up to 2020. Five electronic databases which were used in this research were MEDLINE (via PubMed), Web of Science, Cochrane Library, Embase, and Scopus from the starting date of databases to January 2020. The Keywords "zirconia," "feldspathic," "dental ceramic," "enamel," "Y-TZP," "wear," "glazed," and "polished" were used. English articles were selected in this paper. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement was used as a reporting template as much as possible. Among the initially 133 articles, 59 duplicated articles were removed, and finally, 52 articles were screened and among them, only 16 articles remained for full-text regaining. The results showed that zirconia had significantly less antagonist wear than feldspathic groups, and polishing had less enamel wear than other types of surface treatment like glazing. Only one study showed that glazed zirconia can have more antagonist wear than feldspathic porcelain. Monolithic zirconia had less enamel wear than conventional zirconia and low-fusing feldspathic porcelain showed lower antagonist wear in comparing with other types of feldspathic porcelains.
PubMed: 36605138
DOI: No ID Found -
Medicina (Kaunas, Lithuania) Dec 2022: Porcelain-fused-to-metal (PFM) prostheses are considered the gold standard for the replacement of missing teeth, however, these have several drawbacks. Therefore,... (Review)
Review
: Porcelain-fused-to-metal (PFM) prostheses are considered the gold standard for the replacement of missing teeth, however, these have several drawbacks. Therefore, lithium disilicate (LDS) prostheses have been introduced for the construction of fixed crowns and bridges. The aim of this systematic review was to ascertain the long-term survival of LDS fixed prostheses in comparison to other materials. : The focused question was 'In patients who have undergone prosthodontic treatment (participants), what are the overall survival rate of lithium disilicate (LDS) crowns and fixed bridges; and how do they relate to survival rates of non-LDS similar restoration are the survival and com-plication rates (outcomes) of LDS-based fixed prostheses with complete coverage (intervention) higher or lower when compared to non-LDS materials (controls)?'. An electronic search was conducted in PubMED/Medline, EMBASE, Google Scholar, and ClinicalTrials.gov for articles published between January 2006 and August 2022 using appropriate MeSH terms and keywords. The following types of studies were included: (1) All types of prospective clinical studies; (2) Clinical studies focusing on the survival of fixed LDS bridges and crowns; (3) Studies using natural teeth with complete coverage as abutment for fixed LDS bridges and crowns; and (4) Studies in English. The following studies were excluded: (1) Laboratory/in vitro studies and studies on LDS prostheses with no description of outcomes or survival rates; (2) Commentaries; (3) Letters to the editor; (4) Reviews; and (5) Internal data from manufacturers. The data from included studies were extracted and the risk of bias was assessed within the studies using ROBINS-I. : A total of 25 studies were included in this systematic review. The overall 5-year and 10-year survival rates were of 95-100% and 71.4-100%, respectively. Generally, three-unit bridges had a significantly lower survival rate over 5 and 10 years compared to single-unit crowns. Overall, the risk of bias in the included studies was moderate. : The LDS-based complete coverage prostheses have a survival rate ranging between 48.6% and 100%. Furthermore, due to the lack of comparative studies, the long-term function and survival of LDS prostheses compared to other material prosthesis (PFM and ZrO) is debatable.
Topics: Humans; Dental Porcelain; Prospective Studies; Crowns; Metals
PubMed: 36676719
DOI: 10.3390/medicina59010095