-
Nigerian Journal of Clinical Practice Sep 2023Dental implants are considered an ideal treatment for a missing single tooth. Immediate loading of implants can hasten the procedure, providing comfort to the patients.... (Review)
Review
Dental implants are considered an ideal treatment for a missing single tooth. Immediate loading of implants can hasten the procedure, providing comfort to the patients. Recently, immediate loading of implants has gained much importance as it helps hasten the procedure and provides more comfort to patients. A previous systematic review published 5 years ago compared the success rates between immediate and conventional loading. There are several factors that influence the success rate of implants that were not discussed in detail in the previous review. Hence, the present systematic review is done to report differences in the outcomes from single implant restorations of missing teeth in the posterior region in patients who were subjected to immediate loading and conventional loading. A follow up for 1 year was done. Electronic databases of Medline, Scopus, and Web of Science were searched for publications in the English Language during May 2021. The search results yielded 306 articles, out of which 225 were excluded based on title and abstract screening. Screening of the remaining 81 full text articles yielded 14 original research articles that satisfied the predefined inclusion criteria. Meta analysis was not possible due to the heterogeneity of the data. The overall success rate of the immediate loading of a single implant is 94.31%. Implants in the maxillary region had a higher survival rate than those in the mandibular region. The age range between 18 and 80 years showed good prognosis and outcomes in older individuals. Good oral hygiene was emphasized for all patients to prevent any secondary conditions or delays in healing.
Topics: Adolescent; Adult; Aged; Aged, 80 and over; Humans; Middle Aged; Young Adult; Anodontia; Dental Implants; Dental Prosthesis, Implant-Supported; Immediate Dental Implant Loading; Tooth Loss
PubMed: 37794532
DOI: 10.4103/njcp.njcp_884_22 -
International Journal of Fertility &... Apr 2021The aim of this study is to review current indications to diagnostic and/or operative hysteroscopy in primary and secondary infertility, as well as to determine its... (Review)
Review
BACKGROUND
The aim of this study is to review current indications to diagnostic and/or operative hysteroscopy in primary and secondary infertility, as well as to determine its efficacy in improving fertility.
MATERIALS AND METHODS
We gathered available evidence about the role of hysteroscopy in the management of various infertility conditions. Literature from 2000 to 2020 that pertained to this topic were retrieved and appropriately selected.
RESULTS
Hysteroscopy does not appear as a first line diagnostic procedure for every clinical scenario. However, its diagnostic sensitivity and specificity in assessing intrauterine pathology is superior to all other non-invasive techniques, such as saline infusion/gel instillation sonography (SIS/GIS), transvaginal sonography (TVS) and hysterosalpingography (HSG). Hysteroscopy allows not only a satisfactory evaluation of the uterine cavity but also, the eventual treatment of endocavitary pathologies that may affect fertility both in spontaneous and assisted reproductive technology (ART) cycles.
CONCLUSION
Hysteroscopy, due to its diagnostic and therapeutic potential, should be regarded as a necessary step in infertility management. However, in case of suspected uterine malformation, hysteroscopy should be integrated with other tests [three-dimensional (3D) ultrasound or magnetic resonance imaging (MRI)] for diagnostic confirmation.
PubMed: 33687159
DOI: 10.22074/IJFS.2020.134704 -
International Journal of Implant... Jul 2022There are rising concerns about titanium hypersensitivity reaction regarding dental endosseous implants. This review aims to summarize and compare the validity and... (Review)
Review
PURPOSE
There are rising concerns about titanium hypersensitivity reaction regarding dental endosseous implants. This review aims to summarize and compare the validity and reliability of the available dermatological and laboratory diagnostic tests regarding titanium hypersensitivity. The following PICO design was used: In Patients with titanium dental implants (P) does epicutaneous testing (ECT) (I), compared to lymphocyte transformation test (LTT) or Memory Lymphocyte Immunostimulation Assay (MELISA) (C) detect hypersensitivity reactions (O)? A literature search was performed including all studies dealing with this topic. Studies regarding orthopedic implants were excluded.
METHODS
Three databases (MEDLINE PubMed, Cochrane Library, SciELO) were screened for suitable studies and an additional manual search was also performed. Literature regarding hypersensitivity reactions in orthopedic implants, hypersensitivity reactions regarding implants not related to dental or maxillofacial surgery, animal studies and in vitro studies were excluded. A quality assessment of all selected full-text articles was performed. Randomized, controlled trials were evaluated with the Cochrane Risk of Bias Tool I. Cohort studies were assessed according to the New Castle-Ottawa Scale and case series according to Moga et al. (Development of a quality appraisal tool for case series studies using a modified Delphi technique. 2012).
RESULTS
10 studies were included in the quantitative synthesis and available for the endpoint diagnostics of intolerance reactions to titanium dental implants: 2 clinical studies, 7 cohort studies and 1 case series. The potential for bias (internal validity) for these studies was overall rated as high.
CONCLUSIONS
The study of the available literature regarding ECT and MELISA or LTT in patients with suspected titanium hypersensitivity showed inconsistent results in terms of reliability and validity and thus, those tests should be regarded cautiously. There is strong evidence that titanium hypersensitivity in dental implants is associated with innate immunity: unspecific pro-inflammatory responses due to particle induced hyperreactivity of macrophages or toxicological responses especially towards nanoparticles rather than activation of the adaptive immune system. Therefore, tests detecting allergies do not seem expedient and inflammatory clinical signs should be regarded as leading parameters.
Topics: Animals; Dental Implants; Diagnostic Tests, Routine; Humans; Hypersensitivity; Reproducibility of Results; Titanium
PubMed: 35819566
DOI: 10.1186/s40729-022-00428-0 -
Orthopaedics & Traumatology, Surgery &... Jun 2021Acromioplasty is controversial. Technically, it consists in bone resection, but there is no gold-standard technique and resection is often not quantified. The aims of... (Review)
Review
INTRODUCTION
Acromioplasty is controversial. Technically, it consists in bone resection, but there is no gold-standard technique and resection is often not quantified. The aims of the present study were 1/to assess the methodological quality of studies of acromioplasty; 2/to identify reports in which acromioplasty was quantified; and 3/to assess any correlation between clinical results and resection quantity.
MATERIAL AND METHODS
A systematic literature review was performed on PRISMA criteria in the PubMed, Springer and Ovid databases, including all articles in French or English referring to acromioplasty. Articles were analyzed by 2 surgeons and those with complete procedural description were selected. 1/Methodology was assessed on 3 grades according to aim of acromioplasty, intraoperative assessment of resection, and postoperative radiologic assessment. 2/Results were extracted from articles with robust methodology and quantitative data. 3/Correlations were assessed between clinical results and resection quantity.
RESULTS
Out of the 250 articles retrieved, 94 were selected. 1/44 of these (47%) specified the aim of the acromioplasty, 53 (56%) included an intraoperative clinical assessment criterion, and 13 (14%) included postoperative radiographic assessment. Methodologic quality was insufficient in 33 articles (35%), poor in 23 (24%) and robust in 38 (40%). 2/Seven articles (7.5%) included quantitative results. 3/Three articles assessed correlation between clinical results and resection quantity, but only 1 used reproducible radiographic assessment by critical shoulder angle (CSA); this study reported a significant positive correlation between clinical results and decreased CSA.
CONCLUSION
Methodology in studies of acromioplasty was largely insufficient and resection was usually not quantified. Current data to assess the usefulness of the procedure are sparse. We advocate including a Checklist for Acromioplasty Studies in the methodology of future studies. There is at present no gold-standard for assessing and quantifying acromial resection. CSA seems contributive, but other methods might be worth developing.
LEVEL OF EVIDENCE
IV; systematic review of level 1-4 studies.
Topics: Acromion; Arthroplasty; Arthroscopy; Humans; Rotator Cuff; Shoulder Joint
PubMed: 33771721
DOI: 10.1016/j.otsr.2021.102900 -
Tuberculosis (Edinburgh, Scotland) May 2020Diagnosing tuberculous pleurisy (TP) remains a clinical challenge and the best method to diagnose it is controversial. Although several studies have investigated the... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Diagnosing tuberculous pleurisy (TP) remains a clinical challenge and the best method to diagnose it is controversial. Although several studies have investigated the performance of pleural fluid (PF) T-SPOT for pleural tuberculosis (plTB) diagnosis, the heterogeneity of its accuracy exists. Therefore, we performed an updated meta-analysis of the existing evidence on the utility of PF T-SPOT to diagnose TP.
METHODS
PubMed and EmBase were searched for relevant English articles up to July 29, 2019. Statistical analysis was performed using Stata, Revman, and Meta-Disc. Pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were determined. Summary receiver operating characteristic (SROC) curves and the area under the curve (AUC) were used to summarize the overall diagnostic performance.
RESULTS
A total of 13 studies (997 patients with TP and 656 patients without TP) were identified and enrolled to meta-analysis, giving the following pooled values for diagnostic accuracy of PF T-SPOT: sensitivity, 0.91 (95% CI, 0.89-0.92, I = 80.9%); specificity, 0.88 (95% CI, 0.86-0.91, I = 87.3%); PLR, 6.28 (95% CI, 2.88-13.69, I = 93.3%); NLR, 0.12 (95% CI, 0.07-0.21, I = 84.9%); DOR, 59.74 (95% CI, 24.13-147.93, I = 78.3%); and the area under the SROC curve, 0.95 (95% CI, 0.93-0.97).
CONCLUSIONS
Our meta-analysis suggests that PF T-SPOT has important diagnostic value for plTB. However, the standardization of the operating procedure needs to be further promoted, which would make the results more credible.
Topics: Host-Pathogen Interactions; Humans; Interferon-gamma; Interferon-gamma Release Tests; Mycobacterium tuberculosis; Predictive Value of Tests; Reproducibility of Results; Tuberculosis, Pleural
PubMed: 32501259
DOI: 10.1016/j.tube.2020.101941 -
Health Technology Assessment... Jul 2023Magnetic resonance imaging-based technologies are non-invasive diagnostic tests that can be used to assess non-alcoholic fatty liver disease.
BACKGROUND
Magnetic resonance imaging-based technologies are non-invasive diagnostic tests that can be used to assess non-alcoholic fatty liver disease.
OBJECTIVES
The study objectives were to assess the diagnostic test accuracy, clinical impact and cost-effectiveness of two magnetic resonance imaging-based technologies (LiverMultiScan and magnetic resonance elastography) for patients with non-alcoholic fatty liver disease for whom advanced fibrosis or cirrhosis had not been diagnosed and who had indeterminate results from fibrosis testing, or for whom transient elastography or acoustic radiation force impulse was unsuitable, or who had discordant results from fibrosis testing.
DATA SOURCES
The data sources searched were MEDLINE, MEDLINE Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects and the Health Technology Assessment.
METHODS
A systematic review was conducted using established methods. Diagnostic test accuracy estimates were calculated using bivariate models and a summary receiver operating characteristic curve was calculated using a hierarchical model. A simple decision-tree model was developed to generate cost-effectiveness results.
RESULTS
The diagnostic test accuracy review (13 studies) and the clinical impact review (11 studies) only included one study that provided evidence for patients who had indeterminate or discordant results from fibrosis testing. No studies of patients for whom transient elastography or acoustic radiation force impulse were unsuitable were identified. Depending on fibrosis level, relevant published LiverMultiScan diagnostic test accuracy results ranged from 50% to 88% (sensitivity) and from 42% to 75% (specificity). No magnetic resonance elastography diagnostic test accuracy data were available for the specific population of interest. Results from the clinical impact review suggested that acceptability of LiverMultiScan was generally positive. To explore how the decision to proceed to biopsy is influenced by magnetic resonance imaging-based technologies, the External Assessment Group presented cost-effectiveness analyses for LiverMultiScan plus biopsy versus biopsy only. Base-case incremental cost-effectiveness ratio per quality-adjusted life year gained results for seven of the eight diagnostic test strategies considered showed that LiverMultiScan plus biopsy was dominated by biopsy only; for the remaining strategy (Brunt grade ≥2), the incremental cost-effectiveness ratio per quality-adjusted life year gained was £1,266,511. Results from threshold and scenario analyses demonstrated that External Assessment Group base-case results were robust to plausible variations in the magnitude of key parameters.
LIMITATIONS
Diagnostic test accuracy, clinical impact and cost-effectiveness data for magnetic resonance imaging-based technologies for the population that is the focus of this assessment were limited.
CONCLUSIONS
Magnetic resonance imaging-based technologies may be useful to identify patients who may benefit from additional testing in the form of liver biopsy and those for whom this additional testing may not be necessary. However, there is a paucity of diagnostic test accuracy and clinical impact data for patients who have indeterminate results from fibrosis testing, for whom transient elastography or acoustic radiation force impulse are unsuitable or who had discordant results from fibrosis testing. Given the External Assessment Group cost-effectiveness analyses assumptions, the use of LiverMultiScan and magnetic resonance elastography for assessing non-alcoholic fatty liver disease for patients with inconclusive results from previous fibrosis testing is unlikely to be a cost-effective use of National Health Service resources compared with liver biopsy only.
STUDY REGISTRATION
This study is registered as PROSPERO CRD42021286891.
FUNDING
Funding for this study was provided by the Evidence Synthesis Programme of the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme and will be published in full in ; Vol. 27, No. 10. See the NIHR Journals Library website for further project information.
Topics: Humans; Cost-Benefit Analysis; Liver Cirrhosis; Magnetic Resonance Imaging; Non-alcoholic Fatty Liver Disease; State Medicine
PubMed: 37839810
DOI: 10.3310/KGJU3398 -
European Urology Oncology Apr 2021The 5-yr survival of early-stage renal cell carcinoma (RCC) is approximately 93%, but once metastasised, the 5-yr survival plummets to 12%, indicating that early RCC... (Review)
Review
CONTEXT
The 5-yr survival of early-stage renal cell carcinoma (RCC) is approximately 93%, but once metastasised, the 5-yr survival plummets to 12%, indicating that early RCC detection is crucial to improvement in survival. DNA methylation biomarkers have been suggested to be of potential diagnostic value; however, their current state of clinical translation is unclear and a comprehensive overview is lacking.
OBJECTIVE
To systematically review and summarise all literature regarding diagnostic DNA methylation biomarkers for RCC.
EVIDENCE ACQUISITION
We performed a systematic literature review of PubMed, EMBASE, Medline, and Google Scholar up to January 2019, according to the Preferred Reporting Items for Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines. Included studies were scored according to the Standards for Reporting of Diagnostic Accuracy Studies (STARD) criteria. Forest plots were generated to summarise diagnostic performance of all biomarkers. Level of evidence (LoE) and potential risk of bias were determined for all included studies.
EVIDENCE SYNTHESIS
After selection, 19 articles reporting on 44 diagnostic DNA methylation biomarkers and 11 multimarker panels were included; however, only 15 biomarkers were independently validated. STARD scores varied from 4 to 13 out of 23 points, with a median of 10 points. Large variation in subgroups, methods, and primer locations was observed. None of the reported biomarkers exceeded LoE III, and the majority of studies reported inadequately.
CONCLUSIONS
None of the reported biomarkers exceeded LoE III, indicating their limited clinical utility. Moreover, study reproducibility and further development of these RCC biomarkers are greatly hampered by inadequate reporting.
PATIENT SUMMARY
In this report, we reviewed whether specific biomarkers could be used to diagnose the most common form of kidney cancer. We conclude that due to limited evidence and reporting inconsistencies, none of these biomarkers can be used in clinical practice, and further development towards clinical use is hindered.
Topics: Biomarkers; Carcinoma, Renal Cell; DNA Methylation; Diagnostic Tests, Routine; Humans; Kidney Neoplasms; Reproducibility of Results
PubMed: 31402218
DOI: 10.1016/j.euo.2019.07.011 -
Brazilian Journal of Physical Therapy 2023The validity of the ULTT is unclear, due to heterogeneity of test procedures and variability in the definition of a positive test OBJECTIVE: To evaluate test procedures... (Review)
Review
BACKGROUND
The validity of the ULTT is unclear, due to heterogeneity of test procedures and variability in the definition of a positive test OBJECTIVE: To evaluate test procedures and positive diagnostic criteria for the upper limb tension test (ULTT) in diagnostic test accuracy studies.
METHODS
A systematic review of diagnostic accuracy studies was performed. We conducted a search of the DiTA (Diagnostic Test Accuracy) database and selected primary studies evaluating the diagnostic accuracy of the ULTT. We assessed risk of bias, performed data extraction on study characteristics, test procedures, and positive diagnostic criteria, and performed a descriptive analysis.
RESULTS
We included nine studies (681 participants), four diagnosing people with cervical radiculopathy (CR), four diagnosing people with carpal tunnel syndrome (CTS), and one included both CR and CTS. The risk of bias varied between 2 and 6 out of 6 positive items. Eight studies reported on the ULTT1 (median nerve). Overall, all studies clearly described their test procedures and positive diagnostic criteria although the order of movements and the diagnostic criteria between studies varied. We suggest a more standardised test procedure for the ULTT1 to consist of: 1) stabilising the shoulder in abduction, 2) extending the wrist/fingers, 3) supinating the forearm, 4) externally rotating the shoulder, 5) extending the elbow, and finally 6) performed structural differentiation by side bending (lateral flexion) of the neck. This proposed test procedure should reproduce the symptoms and enables the clinician to evaluate whether symptoms increase/decrease when stressing or relaxing the nerves.
CONCLUSION
Based on our findings we proposed a more standardised test procedure for the ULTT1 with accompanying positive diagnostic criteria to facilitate homogeneity in future diagnostic accuracy studies of the ULTT.
Topics: Humans; Physical Examination; Upper Extremity; Wrist; Carpal Tunnel Syndrome; Fingers
PubMed: 37967500
DOI: 10.1016/j.bjpt.2023.100558 -
BMC Infectious Diseases Jul 2019Lassa fever virus has been enlisted as a priority pathogen of epidemic potential by the World Health organization Research and Development (WHO R & D) Blueprint....
BACKGROUND
Lassa fever virus has been enlisted as a priority pathogen of epidemic potential by the World Health organization Research and Development (WHO R & D) Blueprint. Diagnostics play a crucial role in epidemic preparedness. This systematic review was conducted to determine the sensitivity and specificity of Lassa fever diagnostic tests for humans.
METHODS
We searched OVID Medline, OVID Embase, Scopus and Web of Science for laboratory based and field studies that reported the performance of diagnostic tests for Lassa fever in humans from 1 January 1990 to 25 January 2019. Two reviewers independently screened all the studies and included only studies that involved the evaluation of a Lassa fever diagnostic test and provided data on the sensitivity and specificity. The quality of the studies was assessed using the QUADAS-2 criteria. Data on the study location, study design, type of sample, index test, reference tests and diagnostic performance were extracted from the studies.
RESULTS
Out of a total of 1947 records identified, 1245 non-duplicate citations were obtained. Twenty-six (26) full-text articles examined which identified 08 studies meeting pre-defined criteria. Only one study was a field evaluation study. The sensitivity and specificity of the point of care (RDT) against the Nikisins qPCR were 91.2%(95% CI:75.2-97.7) and 86%(95% CI: 71.4-94.2) at temperatures 18-30 °C, while the sensitivity and specificity of the single IgM ELISA assay against standard RT-PCR were 31.1%(95%CI: 25.6-37) and 95.7%(95%CI:92.8-97.7). The sensitivity of the combined ELISA Antigen/IgM assay(against virus isolation), the recombinant IgM/IgG ELISA(against standard RT-PCR), and the IgM/IgG immunoblot(against IFA) were 88%(95%CI:77-95), 25.9%(95%CI:20.8-31.6), and 90.7%(95%CI:84.13-97.27) respectively. The specificity of the combined ELISA Antigen/IgM assay(against virus isolation), the recombinant IgM/IgG ELISA(against standard RT-PCR), and the IgM/IgG immunoblot(against IFA) were 90%(95%CI:88-91), 100%(95%CI:98.2-100), and 96.3%(95%CI:92.2-100) respectively.
CONCLUSION
Lassa fever has assays for antigenaemia, IgM, IgG and PCR detection. The RDT reportedly performed well but more data are needed from other countries and at temperatures above 30 °C. Most combined immunoassays perform better than the single IgM. Multiplex and pan-Lassa assays are needed. More well conducted field studies are needed.
TRIAL REGISTRATION
Prospero registration number: CRD42018091585 .
Topics: Diagnostic Tests, Routine; Enzyme-Linked Immunosorbent Assay; Humans; Immunoblotting; Lassa Fever; Lassa virus; Point-of-Care Systems; Polymerase Chain Reaction; Sensitivity and Specificity
PubMed: 31324229
DOI: 10.1186/s12879-019-4242-6 -
Annals of Vascular Surgery Oct 2023The optimal diagnostic and treatment algorithm for patients with suspected thoracic outlet syndrome (TOS) remains challenging. Botulinum toxin (BTX) muscle injections... (Review)
Review
BACKGROUND
The optimal diagnostic and treatment algorithm for patients with suspected thoracic outlet syndrome (TOS) remains challenging. Botulinum toxin (BTX) muscle injections have been suggested to shrink muscles in the thoracic outlet reducing neurovascular compression. This systematic review evaluates the diagnostic and therapeutic value of BTX injections in TOS.
METHODS
A systematic review of studies reporting BTX as a diagnostic or therapeutic tool in TOS (or pectoralis minor syndrome as TOS subtype) was conducted in PubMed, Embase, and CENTRAL databases on May 26, 2022. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement was followed. Primary end point was symptom reduction after primary procedure. Secondary end points were symptom reduction after repeated procedures, the degree of symptom reduction, complications, and duration of clinical effect.
RESULTS
Eight studies (1 randomized controlled trial [RCT], 1 prospective cohort study, and 6 retrospective cohort studies) were included reporting 716 procedures in at least 497 patients (at minimum 350 primary and 25 repeated procedures, residual unclear) diagnosed with presumably only neurogenic TOS. Except for the RCT, the methodological quality was fair to poor. All studies were designed on an intention to treat basis, one also investigated BTX as a diagnostic tool to differentiate pectoralis minor syndrome from costoclavicular compression. Reduction of symptoms was reported in 46-63% of primary procedures; no significant difference was found in the RCT. The effect of repeated procedures could not be determined. Degree of symptom reduction was reported by up to 30-42% on the Short-form McGill Pain scale and up to 40 mm on a visual analog scale. Complication rates varied among studies, no major complications were reported. Symptom relief ranged from 1 to 6 months.
CONCLUSIONS
Based on limited quality evidence, BTX may provide short-lasting symptom relief in some neurogenic TOS patients but remains overall undecided. The role of BTX for treatment of vascular TOS and as a diagnostic tool in TOS is currently unexploited.
Topics: Humans; Treatment Outcome; Thoracic Outlet Syndrome; Algorithms; Databases, Factual; Botulinum Toxins
PubMed: 37236533
DOI: 10.1016/j.avsg.2023.05.009