-
Human Reproduction Update Nov 2022To provide the optimal milieu for implantation and fetal development, the female reproductive system must orchestrate uterine dynamics with the appropriate hormones...
BACKGROUND
To provide the optimal milieu for implantation and fetal development, the female reproductive system must orchestrate uterine dynamics with the appropriate hormones produced by the ovaries. Mature oocytes may be fertilized in the fallopian tubes, and the resulting zygote is transported toward the uterus, where it can implant and continue developing. The cervix acts as a physical barrier to protect the fetus throughout pregnancy, and the vagina acts as a birth canal (involving uterine and cervix mechanisms) and facilitates copulation. Fertility can be compromised by pathologies that affect any of these organs or processes, and therefore, being able to accurately model them or restore their function is of paramount importance in applied and translational research. However, innate differences in human and animal model reproductive tracts, and the static nature of 2D cell/tissue culture techniques, necessitate continued research and development of dynamic and more complex in vitro platforms, ex vivo approaches and in vivo therapies to study and support reproductive biology. To meet this need, bioengineering is propelling the research on female reproduction into a new dimension through a wide range of potential applications and preclinical models, and the burgeoning number and variety of studies makes for a rapidly changing state of the field.
OBJECTIVE AND RATIONALE
This review aims to summarize the mounting evidence on bioengineering strategies, platforms and therapies currently available and under development in the context of female reproductive medicine, in order to further understand female reproductive biology and provide new options for fertility restoration. Specifically, techniques used in, or for, the uterus (endometrium and myometrium), ovary, fallopian tubes, cervix and vagina will be discussed.
SEARCH METHODS
A systematic search of full-text articles available in PubMed and Embase databases was conducted to identify relevant studies published between January 2000 and September 2021. The search terms included: bioengineering, reproduction, artificial, biomaterial, microfluidic, bioprinting, organoid, hydrogel, scaffold, uterus, endometrium, ovary, fallopian tubes, oviduct, cervix, vagina, endometriosis, adenomyosis, uterine fibroids, chlamydia, Asherman's syndrome, intrauterine adhesions, uterine polyps, polycystic ovary syndrome and primary ovarian insufficiency. Additional studies were identified by manually searching the references of the selected articles and of complementary reviews. Eligibility criteria included original, rigorous and accessible peer-reviewed work, published in English, on female reproductive bioengineering techniques in preclinical (in vitro/in vivo/ex vivo) and/or clinical testing phases.
OUTCOMES
Out of the 10 390 records identified, 312 studies were included for systematic review. Owing to inconsistencies in the study measurements and designs, the findings were assessed qualitatively rather than by meta-analysis. Hydrogels and scaffolds were commonly applied in various bioengineering-related studies of the female reproductive tract. Emerging technologies, such as organoids and bioprinting, offered personalized diagnoses and alternative treatment options, respectively. Promising microfluidic systems combining various bioengineering approaches have also shown translational value.
WIDER IMPLICATIONS
The complexity of the molecular, endocrine and tissue-level interactions regulating female reproduction present challenges for bioengineering approaches to replace female reproductive organs. However, interdisciplinary work is providing valuable insight into the physicochemical properties necessary for reproductive biological processes to occur. Defining the landscape of reproductive bioengineering technologies currently available and under development for women can provide alternative models for toxicology/drug testing, ex vivo fertility options, clinical therapies and a basis for future organ regeneration studies.
Topics: Animals; Female; Humans; Pregnancy; Bioengineering; Embryo Implantation; Genitalia, Female; Reproduction; Uterus
PubMed: 35652272
DOI: 10.1093/humupd/dmac025 -
Reproductive Biology and Endocrinology... Dec 2022There is a growing body of human, animal and in vitro studies on vitamin D (vit D) substitution in endometriosis. The aim of this systematic review is to critically... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
There is a growing body of human, animal and in vitro studies on vitamin D (vit D) substitution in endometriosis. The aim of this systematic review is to critically appraise and qualitatively synthesize the results of the available studies that examine the supplementation of vit D for endometriosis treatment.
METHODS
A systematic search of the literature was conducted in four electronic databases (Medline, Cochrane, Scopus, Embase) and grey literature for original research articles on humans, animals and in vitro models published in any language.
RESULTS
Four human studies, four animal studies and four in vitro studies were included. Quantitative synthesis of human studies showed no significant effect of vit D intake for dysmenorrhea (2 studies, 44 vit D vs 44 placebo, mean -0.71, 95% CI -1.94, 0.51) and non-cyclic pelvic pain (2 studies, 42 vit D vs 38 placebo, mean 0.34, 95% CI -0.02, 0.71). Regarding reproductive outcomes in women with endometriosis after in vitro fertilization, the only available study showed no differences between women taking vit D and women taking placebo. Three of the four included animal studies showed regression of endometriotic implants when treated with vit D. The in vitro studies demonstrated that vit D decreases invasion and proliferation of endometriotic lesions without affecting apoptosis.
CONCLUSIONS
Although in vitro and animal studies suggest regression of the endometriotic implants and decrease of invasion and proliferation after vit D supplementation, this was not reflected in the results of the meta-analysis, which showed no benefit of vit D supplementation in patients with endometriosis and dysmenorrhea or non-cyclic pelvic pain as well as on the outcome of IVF treatment. However, given the heterogeneity and the diversity of the available studies, more research is required to shed light on the role of vit D supplementation in women with endometriosis.
Topics: Animals; Humans; Female; Endometriosis; Dysmenorrhea; Vitamin D; Vitamins; Pelvic Pain; Dietary Supplements
PubMed: 36578019
DOI: 10.1186/s12958-022-01051-9 -
JAMA Cardiology Jun 2021Early rhythm control of atrial fibrillation (AF) with either antiarrhythmic drugs (AADs) or catheter ablation has been reported to improve cardiovascular outcomes... (Meta-Analysis)
Meta-Analysis
IMPORTANCE
Early rhythm control of atrial fibrillation (AF) with either antiarrhythmic drugs (AADs) or catheter ablation has been reported to improve cardiovascular outcomes compared with usual care; however, the optimal therapeutic modality to achieve early rhythm control is unclear.
OBJECTIVE
To assess the safety and efficacy of AF ablation as first-line therapy when compared with AADs in patients with paroxysmal AF.
DATA SOURCES
PubMed/MEDLINE, Scopus, Google Scholar, and various major scientific conference sessions from January 1, 2000, through November 23, 2020.
STUDY SELECTION
Randomized clinical trials (RCTs) published in English that had at least 12 months of follow-up and compared clinical outcomes of ablation vs AADs as first-line therapy in adults with AF. The quality of individual studies was assessed using the Cochrane risk of bias tool. Six RCTs met inclusion criteria, including 1212 patients.
DATA EXTRACTION AND SYNTHESIS
Two investigators independently extracted data. Reporting was performed in compliance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analysis) guidelines. Analysis was performed using a random-effects model with the Mantel-Haenszel method, and results are presented as 95% CIs.
MAIN OUTCOMES AND MEASURES
Main outcomes were safety and efficacy of AF ablation as first-line therapy when compared with AADs. Trials were evaluated as having low risk of selection and attrition biases, high risk of performance bias, and with unclear risk for detection biases due to unblinding and open-label designs.
RESULTS
A total of 6 RCTs involving 1212 patients with AF were included (609 were randomized to AF ablation and 603 to drug therapy; mean [SD] age, 56 [11] years). Compared with AADs, catheter ablation use was associated with reductions in recurrent atrial arrhythmia (32.3% vs 53%; risk ratio [RR], 0.62; 95% CI, 0.51-0.74; P < .001; I2 = 40%), with a number needed to treat with ablation to prevent 1 arrhythmia of 5. Use of ablation was also associated with reduced symptomatic atrial arrhythmia (11.8% vs 26.4%; RR, 0.44; 95% CI, 0.27-0.72; P = .001; I2 = 54%) and hospitalization (5.6% vs 18.7%; RR, 0.32; 95% CI, 0.19-0.53; P < .001) with no significant difference in serious adverse events between the groups (4.2% vs 2.8%; RR, 1.52; 95% CI, 0.81-2.85; P = .19).
CONCLUSIONS AND RELEVANCE
In this meta-analysis of randomized clinical trials including first-line therapy of patients with paroxysmal AF, catheter ablation compared with antiarrhythmic drugs was associated with reductions in recurrence of atrial arrhythmias and hospitalizations, with no difference in major adverse events.
Topics: Anti-Arrhythmia Agents; Atrial Fibrillation; Catheter Ablation; Hospitalization; Humans; Randomized Controlled Trials as Topic
PubMed: 33909022
DOI: 10.1001/jamacardio.2021.0852 -
International Journal of Implant... Apr 2022The aim of this study was to systematically review the available evidence to evaluate the efficacy of vitamin D supplementation or vitamin D depletion on the... (Review)
Review
PURPOSE
The aim of this study was to systematically review the available evidence to evaluate the efficacy of vitamin D supplementation or vitamin D depletion on the osseointegration of implants in animals and humans.
METHODS
The focus questions addressed were "Do vitamin D deficient subjects treated with (dental) implants have an inferior osseointegration than subjects with adequate serum vitamin D level?" and "Do vitamin D supplemented subjects treated with (dental) implants have a superior osseointegration than subjects with adequate serum vitamin D level?" Humans and animals were considered as subjects in this study. Databases were searched from 1969 up to and including March 2021 using different combination of the following terms: "implant", "bone to implant contact", "vitamin D" and "osseointegration". Letters to the editor, historic reviews, commentaries and articles published in languages other than English and German were excluded. The pattern of the present systematic review was customize to primarily summarize the pertinent data.
RESULTS
Thirteen experimental studies with animals as subject, two clinical studies and three case reports, with humans as subjects, were included. The amount of inserted titanium implants ranged between 24 and 1740. Results from three animal studies showed that vitamin D deficiency has a negative effect on new bone formation and/or bone to implant contact (BIC). Eight animal studies showed that vitamin D supplementation has a enhancing effect on BIC and/or new bone formation around implants. Furthermore, enhancing the impact of vitamin D supplementation on the osseointegration of implants in subjects with diabetes mellitus, osteoporosis and chronic kidney disease (CKD) were assessed. Studies and case reports involving human subjects showed that patients with a low serum vitamin D level have a higher tendency to exhibit an early dental implant failure. When supplemented with vitamin D the osseointegration was successful in the case reports and a beneficial impact on the changes in the bone level during the osseointegration were determined.
CONCLUSIONS
Vitamin D deficiency seems to have a negative effect on the osseointegration of implants in animals. The supplementation of vitamin D appears to improve the osseointegration in animals with systemic diseases, such as vitamin D deficiency, diabetes mellitus, osteoporosis, and CKD. Slight evidence supports the hypothesis that humans similarly benefit from vitamin D supplementation in terms of osseointegration. Further investigation is required to maintain these assumptions.
Topics: Animals; Dental Implantation, Endosseous; Dental Implants; Diabetes Mellitus; Humans; Osseointegration; Osteoporosis; Renal Insufficiency, Chronic; Vitamin D; Vitamin D Deficiency; Vitamins
PubMed: 35403929
DOI: 10.1186/s40729-022-00414-6 -
Clinical Oral Implants Research Nov 2022To answer the following PICO question: "In patients requiring surgical treatment of peri-implantitis (P), is any implant surface decontamination protocol (I) superior to... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
To answer the following PICO question: "In patients requiring surgical treatment of peri-implantitis (P), is any implant surface decontamination protocol (I) superior to others (C) in terms of clinical and radiographic parameters (O)?"
METHODS
Randomized clinical trials (RCTs) comparing two or more decontamination protocols as part of the surgical treatment of peri-implantitis were included. Two authors independently searched for eligible studies, screened titles and abstracts, did full-text analysis, extracted data, and performed the risk-of-bias assessment. Whenever possible, results were summarized through random effects meta-analyses.
RESULTS
Twenty-two manuscripts reporting on 16 RCTs were included, testing mechanical, chemical and physical decontamination protocols. All of them resulted in an improvement in clinical parameters; however, the superiority of specific protocols over others is mainly based on single RCTs. The use of titanium brushes and implantoplasty showed favorable results as single decontamination methods. Meta-analyses indicated a lack of added effect of Er:Yag laser on probing pocket depth (PPD) reduction (n = 2, WMD = -0.24 mm, 95% confidence interval [CI] [-1.10; 0.63], p = .59); while systemic antimicrobials (amoxicillin or azithromycin) showed an added effect on treatment success ([PPD ≤5 mm, no bleeding or suppuration, no progressive bone loss]; n = 2, RR = 1.84, 95% CI [1.17;2.91], p = .008), but not in terms of PPD reduction (n = 2, WMD = 0.93 mm, 95% CI [-0.69; 2.55], p = .26), even if with substantial heterogeneity.
CONCLUSIONS
No single decontamination method demonstrated clear evidence of superiority compared to the others. Systemic antibiotics, but not Er:Yag laser, may provide short-term clinical benefits in terms of treatment success (CRD42020182303).
Topics: Humans; Amoxicillin; Anti-Bacterial Agents; Decontamination; Dental Implants; Peri-Implantitis
PubMed: 36017594
DOI: 10.1111/clr.13992 -
Cochlear Implantation in Children With Single-Sided Deafness: A Systematic Review and Meta-analysis.JAMA Otolaryngology-- Head & Neck... Jan 2021In 2019, the US Food and Drug Administration approved cochlear implantation for children with single-sided deafness (SSD). The absence of robust clinical data specific... (Meta-Analysis)
Meta-Analysis
IMPORTANCE
In 2019, the US Food and Drug Administration approved cochlear implantation for children with single-sided deafness (SSD). The absence of robust clinical data specific to pediatric patients to guide shared decision-making and to identify potential advantages is a challenge in family counseling.
OBJECTIVE
To evaluate the audiological and patient-reported outcomes in children who underwent cochlear implantation for SSD and to assess the association between time of implantation, subjective outcomes, and cochlear implant device use rates.
DATA SOURCE
MEDLINE, Embase, Scopus, Cochrane, and PubMed were searched for English-language articles that were published in a peer-reviewed journal from database inception to February 18, 2020.
STUDY SELECTION
Inclusion criteria were designed to capture studies that evaluated pediatric patients (1) younger than 18 years, (2) with a diagnosis of SSD for which they underwent a cochlear implantation, and (3) with at least 1 outcome of interest measured numerically: speech perception, sound localization, device use, and patient-reported outcomes. Of the 526 articles reviewed, 12 (2.3%) met the selection criteria.
DATA EXTRACTION AND SYNTHESIS
The Meta-analyses Of Observational Studies in Epidemiology (MOOSE) reporting guidelines were followed. Data were pooled using fixed-effect and random-effect models. The following information was obtained from each article: study characteristics, patient characteristics, hearing loss and intervention characteristics, and outcomes.
MAIN OUTCOMES AND MEASURES
Outcomes were (1) postoperative changes in speech perception (in quiet was measured as a proportion of correct responses, and in noise was measured as decibel signal to noise ratio for speech reception threshold) and sound localization (measured in degree of localization error), (2) patient-reported audiological outcomes (measured by the speech, spatial, and qualities of hearing scale), and (3) device use rates among children who received cochlear implantation for SSD.
RESULTS
Twelve observational studies that evaluated 119 children (mean [SD] age, 6.6 [4.0] years) with SSD who received a cochlear implant were included. Most children showed clinically meaningful improvement in speech perception in noise (39 of 49 children [79.6%]) and in quiet (34 of 42 children [81.0%]). Long duration of deafness (>4 years in congenital SSD and >7 years in perilingual SSD) was the most commonly proposed reason for lack of improvement. Sound localization as measured by degrees of error from true location (mean difference [MD], -24.78°; 95% CI, -34.16° to -15.40°; I2 = 10%) improved statistically significantly after cochlear implantation. Patients with acquired SSD and shorter duration of deafness compared with those with congenital SSD reported greater improvements in speech (MD, 2.27; 95% CI, 1.89-2.65 vs 1.58; 95% CI, 1.00-2.16) and spatial (MD, 2.95; 95% CI, 2.66-3.24 vs 1.68; 95% CI, 0.96-2.39) hearing qualities. The duration of deafness among device nonusers was statistically significantly longer than the duration of deafness among regular device users (median difference, 6.84; 95% CI, 4.02-9.58).
CONCLUSIONS AND RELEVANCE
This systematic review and meta-analysis found that cochlear implantation for children with SSD was associated with clinically meaningful improvements in audiological and patient-reported outcomes; shorter duration of deafness may lead to better outcomes. These findings can guide future research efforts, refine cochlear implantation candidacy criteria, and aid in family counseling and shared decision-making.
Topics: Child; Cochlear Implantation; Hearing Loss, Unilateral; Humans; Patient Reported Outcome Measures; Sound Localization; Speech Perception
PubMed: 33151295
DOI: 10.1001/jamaoto.2020.3852 -
Nutrients Aug 2022Phenolic compounds are natural phytochemicals that have recently reported numerous health benefits. Resveratrol, curcumin, and quercetin have recently received the most...
Phenolic compounds are natural phytochemicals that have recently reported numerous health benefits. Resveratrol, curcumin, and quercetin have recently received the most attention among these molecules due to their documented antioxidant effects. The review aims to investigate the effects of these molecules on bone metabolism and their role in several diseases such as osteopenia and osteoporosis, bone tumours, and periodontitis. The PubMed/Medline, Web of Science, Google Scholar, Scopus, Cochrane Library, and Embase electronic databases were searched for papers in line with the study topic. According to an English language restriction, the screening period was from January 2012 to 3 July 2022, with the following Boolean keywords: ("resveratrol" AND "bone"); ("curcumin" AND "bone"); ("quercetin" AND "bone"). A total of 36 papers were identified as relevant to the purpose of our investigation. The studies reported the positive effects of the investigated phenolic compounds on bone metabolism and their potential application as adjuvant treatments for osteoporosis, bone tumours, and periodontitis. Furthermore, their use on the titanium surfaces of orthopaedic prostheses could represent a possible application to improve the osteogenic processes and osseointegration. According to the study findings, resveratrol, curcumin, and quercetin are reported to have a wide variety of beneficial effects as supplement therapies. The investigated phenolic compounds seem to positively mediate bone metabolism and osteoclast-related pathologies.
Topics: Curcumin; Dietary Supplements; Humans; Osteoporosis; Periodontitis; Quercetin; Resveratrol
PubMed: 36079777
DOI: 10.3390/nu14173519 -
Contraception May 2024To summarize and update information regarding drug-drug interactions (DDIs) between antiretrovirals (ARVs) and hormonal contraceptives (HCs). (Review)
Review
OBJECTIVE
To summarize and update information regarding drug-drug interactions (DDIs) between antiretrovirals (ARVs) and hormonal contraceptives (HCs).
DESIGN
Systematic review METHODS: We searched seven databases for peer-reviewed publications from January 1, 2015, through December 31, 2023, including studies of women using ARVs and HCs concurrently with outcomes including therapeutic effectiveness or toxicity, pharmacokinetics (PK), or pharmacodynamics. We summarized findings and used checklists to assess evidence quality.
RESULTS
We included 49 articles, with clinical, ARV or HC PK outcomes reported by 39, 25, and 30 articles, respectively, with some articles reporting outcomes in two or more categories. Fifteen of 18 articles assessing DDIs between efavirenz and progestin implants, emergency contraception, or combined hormonal intravaginal rings found higher pregnancy rates, luteal progesterone levels suggesting ovulation, or reduced progestin PK values. Five studies documented that CYP2B6 single nucleotide polymorphisms exacerbated this DDI. One cohort detected doubled bone density loss with concomitant depot medroxyprogesterone acetate (DMPA) and tenofovir disoproxil fumarate (TDF)-containing ART use versus TDF alone. No other studies described DDIs impacting clinical outcomes. Few adverse events were attributed to ARV-HC use with none exceeding Grade 2. Evidence quality was generally moderate, with dis-similar treatment and control groups, identifying and controlling for confounding, and minimizing attrition bias in the study design being the most frequent limitations.
CONCLUSION
Most ARVs and HCs may be used safely and effectively together. TDF-DMPA DDIs warrant longer-term study on bone health and consideration of alternate combinations. For efavirenz-based ART, client counselling on relative risks, including both potential increase in pregnancy rate with concomitant efavirenz and implant use and lower pregnancy rates compared to other HCs even with concomitant efavirenz use, should continue to allow users comprehensive method choice.
PubMed: 38762199
DOI: 10.1016/j.contraception.2024.110490 -
The Cochrane Database of Systematic... Jan 2023Uveitis is a term used to describe a group of intraocular inflammatory diseases. Uveitis is the fifth most common cause of vision loss in high-income countries, with the... (Review)
Review
BACKGROUND
Uveitis is a term used to describe a group of intraocular inflammatory diseases. Uveitis is the fifth most common cause of vision loss in high-income countries, with the highest incidence of disease in the working-age population. Corticosteroids are the mainstay of treatment for all subtypes of non-infectious uveitis. They can be administered orally, topically with drops, by periocular (around the eye) or intravitreal (inside the eye) injection, or by surgical implantation.
OBJECTIVES
To determine the efficacy and safety of steroid implants in people with chronic non-infectious posterior uveitis, intermediate uveitis, and panuveitis.
SEARCH METHODS
We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register), MEDLINE Ovid, Embase, PubMed, LILACS, and three trials registries to November 2021. SELECTION CRITERIA: We included randomized controlled trials comparing either fluocinolone acetonide (FA) or dexamethasone (DEX) intravitreal implants with standard-of-care therapy or sham procedures, with at least six months of follow-up after treatment. We included studies that enrolled participants of all ages, who had chronic non-infectious posterior uveitis, intermediate uveitis, or panuveitis with vision that was better than hand-motion.
DATA COLLECTION AND ANALYSIS
We applied standard Cochrane methodology.
MAIN RESULTS
We included data from four trials (683 participants, 907 eyes) that compared corticosteroid implants with either sham or standard-of-care therapy. Study characteristics and risk of bias Of the two trials that compared corticosteroid implants with sham procedure, one examined a 0.18 mg FA implant, and the other, a 0.7 mg DEX implant. The other two trials compared a 0.59 mg FA implant with standard-of-care therapy, which included systemic corticosteroids and immunosuppressive medications, if needed. We assessed the four trials to be at either low risk, or with some concerns of risk of bias across all domains. Findings Using sham procedure as control, combined results at the six-month primary time point suggested that corticosteroid implants may decrease the risk of uveitis recurrence by 60% (relative risk [RR] 0.40, 95% confidence interval [CI] 0.30 to 0.54; 2 trials, 282 participants; low-certainty evidence); and lead to a greater improvement in best-corrected visual acuity (BCVA; mean difference [MD] 0.22 logMAR, 95% CI 0.13 to 0.31; 1 trial, 153 participants; low-certainty evidence). Evidence based on a single-study report (146 participants) suggested that steroid implants may have no effects on visual functioning quality of life, measured on the National Eye Institute 25-Item Visual Function Questionnaire (MD 2.85, 95%CI -3.64 to 9.34; 1 trial, 146 participants; moderate-certainty evidence). Using standard-of care therapy as control, combined estimates at the 24-month primary time point suggested that corticosteroid implants were likely to decrease the risk of recurrence of uveitis by 54% (RR 0.46, 95% CI 0.35 to 0.60; 2 trials, 619 eyes). Combined estimates at 24 months also suggested that steroid implants may have little to no effects on BCVA (MD 0.05 logMAR, 95% CI -0.02 to 0.12; 2 trials, 619 eyes; low-certainty evidence). Evidence based on a single-study report (232 participants) suggested that steroid implants may have minimal clinical effects on visual functioning (MD 4.64, 95% CI 0.13 to 9.15; 1 trial, 232 participants; moderate-certainty evidence); physical functioning (SF-36 physical subscale MD 2.95, 95% CI 0.55 to 5.35; 1 trial, 232 participants; moderate-certainty evidence); or mental health (SF-36 mental subscale MD 3.65, 95% CI 0.52 to 6.78; 1 trial, 232 participants; moderate-certainty evidence); but not on EuroQoL (MD 6.17, 95% CI 1.87 to 10.47; 1 trial, 232 participants; moderate-certainty evidence); or EuroQoL-5D scale (MD 0.02, 95% CI -0.04 to 0.08; 1 trial, 232 participants; moderate-certainty evidence). Adverse effects Compared with sham procedures, corticosteroid implants may slightly increase the risk of cataract formation (RR 2.69, 95% CI 1.17 to 6.18; 1 trial, 90 eyes; low-certainty evidence), but not the risk of cataract progression (RR 2.00, 95% CI 0.65 to 6.12; 1 trial, 117 eyes; low-certainty evidence); or the need for surgery (RR 2.98, 95% CI 0.82 to 10.81; 1 trial, 180 eyes; low-certainty evidence), during up to 12 months of follow-up. These implants may increase the risk of elevated intraocular pressure ([IOP] RR 2.81, 95% CI 1.42 to 5.56; 2 trials, 282 participants; moderate-certainty evidence); and the need for IOP-lowering eyedrops (RR 1.85, 95% CI 1.05 to 3.25; 2 trials, 282 participants; moderate-certainty evidence); but not the need for IOP-lowering surgery (RR 0.72, 95% CI 0.13 to 4.17; 2 trials, 282 participants; moderate-certainty evidence). Evidence comparing the 0.59 mg FA implant with standard-of-care suggested that the implant may increase the risk of cataract progression (RR 2.71, 95% CI 2.06 to 3.56; 2 trials, 210 eyes; low-certainty evidence); and the need for surgery (RR 2.98, 95% CI 2.33 to 3.79; 2 trials, 371 eyes; low-certainty evidence); along with the risk of elevated IOP (RR 3.64, 95% CI 2.71 to 4.87; 2 trials, 605 eyes; moderate-certainty evidence); and the need for medical (RR 3.04, 95% CI 2.36 to 3.91; 2 trials, 544 eyes; moderate-certainty evidence); or surgical interventions (RR 5.43, 95% CI 3.12 to 9.45; 2 trials, 599 eyes; moderate-certainty evidence). In either comparison, these implants did not increase the risk for endophthalmitis, retinal tear, or retinal detachment (moderate-certainty evidence). AUTHORS' CONCLUSIONS: Our confidence is limited that local corticosteroid implants are superior to sham therapy or standard-of-care therapy in reducing the risk of uveitis recurrence. We demonstrated different effectiveness on BCVA relative to comparators in people with non-infectious uveitis. Nevertheless, the evidence suggests that these implants may increase the risk of cataract progression and IOP elevation, which will require interventions over time. To better understand the efficacy and safety profiles of corticosteroid implants, we need future trials that examine implants of different doses, used for different durations. The trials should measure core standard outcomes that are universally defined, and measured at comparable follow-up time points.
Topics: Humans; Adrenal Cortex Hormones; Cataract; Glaucoma; Panuveitis; Quality of Life; Steroids; Uveitis; Uveitis, Intermediate; Randomized Controlled Trials as Topic
PubMed: 36645716
DOI: 10.1002/14651858.CD010469.pub3 -
Periodontology 2000 Oct 2023Bone regeneration is often required concomitant with implant placement to treat a bone fenestration, a dehiscence, and for contouring. This systematic review assessed... (Meta-Analysis)
Meta-Analysis Review
Bone regeneration is often required concomitant with implant placement to treat a bone fenestration, a dehiscence, and for contouring. This systematic review assessed the impact of different biomaterials employed for guided bone regeneration (GBR) simultaneous to implant placement on the stability of radiographic peri-implant bone levels at ≥12 months of follow-up (focused question 1), as well as on bone defect dimension (width/height) changes at re-assessment after ≥4 months (focused question 2). Only randomized controlled trials (RCTs) and controlled clinical trials (CCTs) that compared different biomaterials for GBR were considered. A Bayesian network meta-analysis (NMA) was performed using a random-effects model. A ranking probability between treatments was obtained, as well as an estimation of the surface under the cumulative ranking value (SUCRA). Overall, whenever the biological principle of GBR was followed, regeneration occurred in a predictable way, irrespective of the type of biomaterial used. A lower efficacy of GBR treatments was suggested for initially large defects, despite the trend did not reach statistical significance. Regardless of the biomaterial employed, a certain resorption of the augmented bone was observed overtime. While GBR was shown to be a safe and predictable treatment, several complications (including exposure, infection, and soft tissue dehiscence) were reported, which tend to be higher when using cross-linked collagen membranes.
Topics: Humans; Alveolar Ridge Augmentation; Biocompatible Materials; Bone Regeneration; Dental Implantation, Endosseous; Dental Implants; Guided Tissue Regeneration, Periodontal; Network Meta-Analysis
PubMed: 37752820
DOI: 10.1111/prd.12531