-
Neuropsychology Review Mar 2023Mild traumatic brain injury (mTBI) is a major public health concern. Cerebrovascular alterations play a significant role in the evolution of injury sequelae and in the... (Review)
Review
Mild traumatic brain injury (mTBI) is a major public health concern. Cerebrovascular alterations play a significant role in the evolution of injury sequelae and in the process of post-traumatic brain repair. Arterial spin labeling (ASL) is an advanced perfusion magnetic resonance imaging technique that permits noninvasive quantification of cerebral blood flow (CBF). This is the first systematic review of ASL research findings in patients with mTBI. Our approach followed the American Academy of Neurology (AAN) and PRISMA guidelines. We searched Ovid/MEDLINE, Web of Science, Scopus, and the Cochrane Index for relevant articles published as of February 20, 2020. Full-text results were combined into Rayyan software for further evaluation. Data extraction, including risk of bias ratings, was performed using American Academy of Neurology's four-tiered classification scheme. Twenty-three articles met inclusion criteria comprising data on up to 566 mTBI patients and 654 control subjects. Of the 23 studies, 18 reported some type of regional CBF abnormality in mTBI patients at rest or during a cognitive task, with more findings of decreased than increased CBF. The evidence supports the conclusion that mTBI likely causes ASL-derived CBF anomalies. However, synthesis of findings was challenging due to substantial methodological variations across studies and few studies with low risk of bias. Thus, larger-scale prospective cohort studies are needed to more definitively chart the course of CBF changes in humans after mTBI and to understand how individual difference factors contribute to post-injury CBF changes.
Topics: Humans; Prospective Studies; Magnetic Resonance Imaging; Brain; Magnetic Resonance Angiography; Brain Concussion; Perfusion
PubMed: 32808244
DOI: 10.1007/s11065-020-09451-7 -
Animals : An Open Access Journal From... Dec 2022Electrotherapy modalities are currently used in the treatment of animals, but the evidence base supporting their use has not yet been systematically reviewed. Cochrane... (Review)
Review
Electrotherapy modalities are currently used in the treatment of animals, but the evidence base supporting their use has not yet been systematically reviewed. Cochrane guidelines, as adapted by the Swedish Agency for Health Technology Assessment and Assessment of Social Services, were followed for this systematic review. A literature search regarding all currently known electrotherapy modalities applied to horses, dogs, and cats was conducted for the years 1980-2020 using three databases: CABI, PubMed, and Web of Science Core Collection. Of the 5385 references found, 41 articles were included in the review: 13 papers on pulsed electromagnetic field therapy (PEMFT), 7 on neural electrical muscle stimulation (NEMS), 5 on transcutaneous electrical nerve stimulation (TENS), 4 on static magnets, 3 on interference, 2 each on percutaneous electrical neural stimulation (PENS), bioelectricity, and diathermy, and 1 each on micro-pulsed stimulation, capacitive coupled electrical stimulation, and microwave therapy. The literature per modality was limited in quantity (mean 3.7 papers). Half of the articles were assessed to have a high risk of bias (20 high, 7 moderate, and 14 low). The existing literature used a spectrum of indications and treatment parameters, which makes comparisons and drawing conclusions to support the use of these modalities in clinical practice challenging. The current scientific evidence is not sufficient to support the clinical effects of electrotherapies for any clinical indication in horses, dogs or cats. The selected suggestive results warrant further high-quality research on PEMFT, NEMS, TENS, and PENS.
PubMed: 36611674
DOI: 10.3390/ani13010064 -
BMC Oral Health Jul 2022Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also...
BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.
Topics: Artifacts; Humans; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires; Stainless Steel
PubMed: 35854295
DOI: 10.1186/s12903-022-02317-9 -
Cephalalgia : An International Journal... Feb 2023Migraine is a highly prevalent primary headache disorder. Despite a high burden of disease, key disease mechanisms are not entirely understood. Functional magnetic... (Review)
Review
BACKGROUND
Migraine is a highly prevalent primary headache disorder. Despite a high burden of disease, key disease mechanisms are not entirely understood. Functional magnetic resonance imaging is an imaging method using the blood-oxygen-level-dependent signal, which has been increasingly used in migraine research over recent years. This systematic review summarizes recent findings employing functional magnetic resonance imaging for the investigation of migraine.
METHODS
We conducted a systematic search and selection of functional magnetic resonance imaging applications in migraine from April 2014 to December 2021 (PubMed and references of identified articles according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines). Methodological details and main findings were extracted and synthesized.
RESULTS
Out of 224 articles identified, 114 were included after selection. Repeatedly emerging structures of interest included the insula, brainstem, limbic system, hypothalamus, thalamus, and functional networks. Assessment of functional brain changes in response to treatment is emerging, and machine learning has been used to investigate potential functional magnetic resonance imaging-based markers of migraine.
CONCLUSIONS
A wide variety of functional magnetic resonance imaging-based metrics were found altered across the brain for heterogeneous migraine cohorts, partially correlating with clinical parameters and supporting the concept to conceive migraine as a brain state. However, a majority of findings from previous studies have not been replicated, and studies varied considerably regarding image acquisition and analyses techniques. Thus, while functional magnetic resonance imaging appears to have the potential to advance our understanding of migraine pathophysiology, replication of findings in large representative datasets and precise, standardized reporting of clinical data would likely benefit the field and further increase the value of observations.
Topics: Humans; Migraine Disorders; Brain; Magnetic Resonance Imaging; Brain Mapping; Hypothalamus
PubMed: 36751858
DOI: 10.1177/03331024221128278 -
PeerJ 2023To explore the potential value of magnetic resonance (MR) and computed tomography (CT) enterography in the diagnosis of small intestinal tumor (SIT). (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To explore the potential value of magnetic resonance (MR) and computed tomography (CT) enterography in the diagnosis of small intestinal tumor (SIT).
METHODS
Articles reporting on the diagnosis of SIT by MR and CT enterography deposited in Chinese and foreign literature databases were identified and evaluated using the quality assessment of diagnostic accuracy studies (QUADAS). The diagnostic data extracted from the articles were adopted for meta-analysis using Meta-disc 1.40 software. Analysis was undertaken to compare the sensitivity, specificity, positive and negative likelihood ratios, and the diagnostic odds ratio (DOR) of MR and CT enterography in the diagnosis of SIT. The diagnostic values of the two imaging methods were analyzed by summary receiver operating characteristic (SROC) curves. The meta-analysis was registered at INPLASY (202380053).
RESULTS
A total of eight articles, including 551 cases of SIT were included in this analysis. The pooled sensitivity and specificity of MR enterography were 0.92 (95% CI [0.89-0.95]) and 0.81 (95% CI [0.74-0.86]), respectively, whilst CT enterography had a sensitivity of 0.93 (95% CI [0.90-0.95]) and a specificity of 0.83 (95% CI [0.76-0.88]). For MR enterography, the combined positive likelihood ratio was 4.90 (95% CI [3.50-6.70]), the combined negative likelihood ratio was 0.10 (95% CI [0.07-0.14]), and the area under the receiver operating characteristic curve (AUROC) was 0.940. For CT enterography, the corresponding values were 5.40 (95% CI [3.90-7.40]), 0.08 (95% CI [0.06-0.12]), and 0.950, respectively. When the pretest probability for MR was assumed to be 50%, the posterior probabilities for positive and negative results were calculated as 83% and 9%, respectively. For CT enterography with a pretest probability of 50%, the posterior probabilities of positive and negative results were 84% and 8%, respectively.
CONCLUSION
MR and CT enterography have high accuracy in the diagnosis of SIT and have a valuable role in the diagnosis and management of these tumors.
Topics: Humans; Magnetic Resonance Imaging; Tomography, X-Ray Computed; Sensitivity and Specificity; Intestinal Neoplasms; Magnetic Resonance Spectroscopy
PubMed: 38144202
DOI: 10.7717/peerj.16687 -
European Urology Open Science Jun 2023Prebiopsy magnetic resonance imaging (MRI) of the prostate has been shown to increase the accuracy of the diagnosis of clinically significant prostate cancer. However,... (Review)
Review
CONTEXT
Prebiopsy magnetic resonance imaging (MRI) of the prostate has been shown to increase the accuracy of the diagnosis of clinically significant prostate cancer. However, evidence is still evolving about how best to integrate prebiopsy MRI into the diagnostic pathway and for which patients, and whether MRI-based pathways are cost effective.
OBJECTIVE
This systematic review aimed to assess the evidence for the cost effectiveness of prebiopsy MRI-based prostate cancer diagnostic pathways.
EVIDENCE ACQUISITION
INTERTASC search strategies were adapted and combined with terms for prostate cancer and MRI, and used to search a wide range of databases and registries covering medicine, allied health, clinical trials, and health economics. No limits were set on country, setting, or publication year. Included studies were full economic evaluations of prostate cancer diagnostic pathways with at least one strategy including prebiopsy MRI. Model-based studies were assessed using the Philips framework, and trial-based studies were assessed using the Critical Appraisal Skills Programme checklist.
EVIDENCE SYNTHESIS
A total of 6593 records were screened after removing duplicates, and eight full-text papers, reporting on seven studies (two model based) were included in this review. Included studies were judged to have a low-to-moderate risk of bias. All studies reported cost-effectiveness analyses based in high-income countries but had significant heterogeneity in diagnostic strategies, patient populations, treatment strategies, and model characteristics. Prebiopsy MRI-based pathways were cost effective compared with pathways relying on ultrasound-guided biopsy in all eight studies.
CONCLUSIONS
Incorporation of prebiopsy MRI into prostate cancer diagnostic pathways is likely to be more cost effective in than that into pathways relying on prostate-specific antigen and ultrasound-guided biopsy. The optimal prostate cancer diagnostic pathway design and method of integrating prebiopsy MRI are not yet known. Variations between health care systems and diagnostic approaches necessitate further evaluation for a particular country or setting to know how best to apply prebiopsy MRI.
PATIENT SUMMARY
In this report, we looked at studies that measured the health care costs and benefits and harms to patients of using prostate magnetic resonance imaging (MRI), to decide whether men need a prostate biopsy for possible prostate cancer. We found that using prostate MRI before biopsy is likely to be less costly for health care services and probably has better outcomes for patients being investigated for prostate cancer. It is still unclear what the best way to use prostate MRI is.
PubMed: 37213242
DOI: 10.1016/j.euros.2023.03.010 -
Frontiers in Neuroscience 2021Magnetic control systems of micro-robots have recently blossomed as one of the most thrilling areas in the field of medical treatment. For the sake of learning how to...
Magnetic control systems of micro-robots have recently blossomed as one of the most thrilling areas in the field of medical treatment. For the sake of learning how to apply relevant technologies in medical services, we systematically review pioneering works published in the past and divide magnetic control systems into three categories: stationary electromagnet control systems, permanent magnet control systems and mobile electromagnet control systems. Based on this, we ulteriorly analyze and illustrate their respective strengths and weaknesses. Furthermore, aiming at surmounting the instability of magnetic control system, we utilize SolidWorks2020 software to partially modify the SAMM system to make its final overall thickness attain 111 mm, which is capable to control and observe the motion of the micro-robot under the microscope system in an even better fashion. Ultimately, we emphasize the challenges and open problems that urgently need to be settled, and summarize the direction of development in this field, which plays a momentous role in the wide and safe application of magnetic control systems of micro-robots in clinic.
PubMed: 34512256
DOI: 10.3389/fnins.2021.736730 -
Pediatric Radiology Jan 2021Whole-body magnetic resonance imaging (MRI) is increasingly being used for a number of indications. Our aim was to review and describe indications and scan protocols for... (Review)
Review
Whole-body magnetic resonance imaging (MRI) is increasingly being used for a number of indications. Our aim was to review and describe indications and scan protocols for diagnostic value of whole-body MRI for multifocal disease in children and adolescents, we conducted a systematic search in Medline, Embase and Cochrane for all published papers until November 2018. Relevant subject headings and free text words were used for the following concepts: 1) whole-body, 2) magnetic resonance imaging and 3) child and/or adolescent. Included were papers in English with a relevant study design that reported on the use and/or findings from whole-body MRI examinations in children and adolescents. This review includes 54 of 1,609 papers identified from literature searches. Chronic nonbacterial osteomyelitis, lymphoma and metastasis were the most frequent indications for performing a whole-body MRI. The typical protocol included a coronal STIR (short tau inversion recovery) sequence with or without a coronal T1-weighted sequence. Numerous studies lacked sufficient data for calculating images resolution and only a few studies reported the acquired voxel volume, making it impossible for others to reproduce the protocol/images. Only a minority of the included papers assessed reliability tests and none of the studies documented whether the use of whole-body MRI affected mortality and/or morbidity. Our systematic review confirms significant variability of technique and the lack of proven validity of MRI findings. The information could potentially be used to boost attempts towards standardization of technique, reporting and guidelines development.
Topics: Adolescent; Child; Humans; Magnetic Resonance Imaging; Neoplasms; Osteomyelitis; Reproducibility of Results; Whole Body Imaging
PubMed: 32588094
DOI: 10.1007/s00247-020-04735-9 -
Neuromodulation : Journal of the... Jun 2022Theta burst stimulation (TBS) is often used in clinical practice and research protocols for adults with neuropsychiatric disorders. There are substantial knowledge gaps... (Review)
Review
OBJECTIVES
Theta burst stimulation (TBS) is often used in clinical practice and research protocols for adults with neuropsychiatric disorders. There are substantial knowledge gaps related to the application of TBS in children and adolescents. This systematic review examined the safety and tolerability of TBS in children and adolescents.
MATERIALS AND METHODS
A systematic review of human TBS studies in children and adolescents was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The following inclusion criteria were applied: 1) articles in English language only; 2) studies that included child and adolescent participants (up to 21 years of age); 3) studies that administered intermittent TBS or continuous TBS or both to participants; 4) studies that had an outcome measure; and 5) availability of full text material. The primary outcome measures were tolerability and safety. When feasible, the clinical effects were reviewed.
RESULTS
Twenty relevant articles met the criteria for inclusion. The reported adverse events were mild and similar to what is noted in adult studies. The most common symptom was headache. One case report described a seizure induced by TBS. Collectively, the studies were heterogeneous but the methodologic quality of randomized trials was high.
CONCLUSIONS
TBS interventions in children may have similar safety, tolerability, and feasibility as compared to adults. However, long-term, follow-up studies of TBS are lacking. Future dose-ranging studies with systematic assessment of adverse events will be important in the translation of findings with TBS from adults to youth.
Topics: Adolescent; Adult; Child; Follow-Up Studies; Headache; Humans; Transcranial Magnetic Stimulation
PubMed: 35670061
DOI: 10.1111/ner.13455 -
Journal of Integrative Neuroscience Sep 2023Patients with post-stroke memory disorder (PSMD) have poor quality of life and it is necessary to identify more beneficial stimulation protocols for treatment with... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Patients with post-stroke memory disorder (PSMD) have poor quality of life and it is necessary to identify more beneficial stimulation protocols for treatment with repetitive transcranial magnetic stimulation (rTMS). This meta-analysis was conducted to investigate the efficacy and safety of rTMS for improving memory performance, global cognition, and activities of daily living (ADL) among patients with PSMD.
METHODS
The PubMed, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), Chinese Biomedical Literature Database, Chinese National Knowledge Infrastructure, China Science and Technology Journal Database, and Wanfang databases were screened to identify relevant randomized controlled trials. The primary outcome was memory performance; secondary outcomes included global cognition, ADL, and adverse events. STATA software was used to perform data synthesis.
RESULTS
Five articles with a total of 192 participants were included. The results indicated that rTMS was superior to control treatments for improving memory performance (mean difference [MD] = 1.73, 95% CI [Confidence Interval] [0.85, 2.60], 0.001), global cognition (MD = 2.44, 95% CI [0.96, 3.93], 0.001), and ADL (MD = 10.29, 95% CI [5.10, 15.48], 0.001). No significant differences were found between the low-frequency (LF) and high-frequency (HF) rTMS subgroups ( 0.47, = 0.00%) or between the sham rTMS and non-rTMS subgroups ( 0.94, = 0.00%). Four studies did not reported adverse events.
CONCLUSIONS
rTMS may improve memory function, global cognition, and the ability to perform ADL in patients with PSMD. LF-rTMS and HF-rTMS may have equal efficacy for treatment of PSMD. Future studies should consider extending the follow-up period to explore the safety and long-term efficacy of rTMS for treatment of PSMD and the appropriate choice of placebo for clinical trials of this treatment.
Topics: Humans; Transcranial Magnetic Stimulation; Activities of Daily Living; Quality of Life; Memory Disorders; Memory; Stroke
PubMed: 37735134
DOI: 10.31083/j.jin2205131