-
Head & Face Medicine Jul 2021Orthodontic retention aims to maintain optimal teeth positions after active treatment. The stability is affected by numerous factors, including patients' individual... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Orthodontic retention aims to maintain optimal teeth positions after active treatment. The stability is affected by numerous factors, including patients' individual features, thus retention should be adjusted in the most optimal way. Bonding a retainer makes retention less dependent on patient's compliance.
QUESTIONS ARISE
What wire or fiber splint type provides the best treatment stability? What materials should be used to bond the wire or fiber splint? Should be the bonding procedure be direct or indirect? The aim of the study is to assess and synthesize available controlled trials investigating failures of fixed retainers.
METHODS
Literature searches of free text and MeSH terms were performed in Scopus, Web of Science, Embase and PubMed Central in order to find studies, referring to failures of fixed retention (12th February 2021). The keywords were: ("orthodontic retainers AND failure AND wire"). The framework of this systematic review according to PICO was: Population: orthodontic patients; Intervention: fixed orthodontic retainer bonding; Comparison: Different protocols of fixed orthodontic retention applied; Outcomes: failure rate, survival rate. Three different specific scales from the Cochrane Collaboration Handbook were used, according to each study type. Additionally, a meta-analysis was conducted to compare the effectiveness of retention using fiber reinforced composite and multistranded steel wire.
RESULTS
The search identified 177 potential articles: 114 from PubMed, 41 from Scopus, 20 from Web of Science and 2 from Embase. After excluding studies inconsistent with selection criteria, 21 studies were included and subjected to qualitative analysis. The main outcome investigated was failure rate. This systematic review has some potential limitations due to the heterogeneity of design between included studies.
CONCLUSIONS
No retainer is proved to guarantee a perfect stability of dental alignment. The retainer should be bonded to all adherent teeth, preferably with additional use of bonding resin. No wire or fiber splint present superior characteristics concerning failure rate. Fiber reinforced composite retention is more sensitive to operator skills, and with imperfect bonding technique, failure rate is much higher. During the first 6 months after bonding retainer the patient should be under frequent control. The study protocol was registered in PROSPERO database with the number CRD42021233406.
Topics: Dental Bonding; Humans; Orthodontic Appliance Design; Orthodontic Retainers; Orthodontic Wires
PubMed: 34301280
DOI: 10.1186/s13005-021-00281-3 -
Dental Research Journal 2023An ever-increasing demand is seen for clear aligners and transparent vacuum-formed retainers. They are esthetic and convenient. However, the biomaterials used in these... (Review)
Review
A systematic review of biocompatibility and safety of orthodontic clear aligners and transparent vacuum-formed thermoplastic retainers: Bisphenol-A release, adverse effects, cytotoxicity, and estrogenic effects.
BACKGROUND
An ever-increasing demand is seen for clear aligners and transparent vacuum-formed retainers. They are esthetic and convenient. However, the biomaterials used in these appliances might pose biological safety and biocompatibility threats in terms of their bisphenol-A (BPA) release, cytotoxicity, adverse effects, and estrogenic effects. Due to the controversial results and the lack of any systematic reviews in this regard, we conducted this systematic review.
MATERIALS AND METHODS
Web of Science, PubMed, Cochrane, Scopus, and Google Scholar as well as references of the found articles were searched (independently by 3 researchers) up to December 22, 2021, to find studies relevant to the biocompatibility of clear aligners and thermoplastic retainers. The search keywords were a combination of the following (and more): Essix, vacuum-formed aligner, thermoplastic aligner, clear aligner, Invisalign, vacuum-formed retainer, BPA release, monomer release, cytotoxicity, estrogenicity, biocompatibility, chemical properties, and oral epithelial cell. As eligibility criteria, articles in all languages would be included as long as their text could be translated clearly using online translators or by professional translators; all types of publications (article, book, and thesis) would be included if containing relevant studies and information; they should have been on clear liners or thermoplastic retainers; and they should have been on biocompatibility, safety, cytotoxicity, or estrogenicity of clear aligners or thermoplastic retainers. There were no restrictions on the type of study (randomized clinical trials, experimental studies). Studies focusing merely on the mechanical properties of clear aligners or thermoplastic retainers (without examining their chemical properties) would be excluded. The risk of bias was assessed.
RESULTS
The risk of bias was rather low. However, the methodologies of the studies were quite different. Overall, 16 articles (1 randomized clinical trial and 15 studies) were identified. The data for BPA release were reported in four articles (1 clinical trial and 3 studies). Quantitatively speaking, the amount of released BPA reported by studies was very low, if not zero. However, the BPA level was very high in the only randomized clinical trial. Many adverse effects were linked to using clear aligners or transparent retainers, including pain and soft-tissue issues such as burning, tingling, sore tongue, lip swelling, blisters, ulceration, dry mouth, periodontal problems, and even systemic problems such as difficulty in breathing. Besides these biological adverse effects, oral dysfunctions and speech difficulties and tooth damage may be associated with clear aligners and should as well be taken into consideration.
CONCLUSION
Given the very high levels of BPA leach observed in the only clinical trial and considering other possible dangers of small traces of BPA (even at low doses) and also given the numerous adverse events linked to clear aligners or transparent retainers, it seems that safety of these appliances might be questionable and more clinical studies of biocompatibility are needed in this regard.
PubMed: 37180685
DOI: No ID Found -
The Cochrane Database of Systematic... May 2023Without a phase of retention after successful orthodontic treatment, teeth tend to 'relapse', that is, to return to their initial position. Retention is achieved by... (Review)
Review
BACKGROUND
Without a phase of retention after successful orthodontic treatment, teeth tend to 'relapse', that is, to return to their initial position. Retention is achieved by fitting fixed or removable retainers to provide stability to the teeth while avoiding damage to teeth and gums. Removable retainers can be worn full- or part-time. Retainers vary in shape, material, and the way they are made. Adjunctive procedures are sometimes used to try to improve retention, for example, reshaping teeth where they contact ('interproximal reduction'), or cutting fibres around teeth ('percision'). This review is an update of one originally published in 2004 and last updated in 2016.
OBJECTIVES
To evaluate the effects of different retainers and retention strategies used to stabilise tooth position after orthodontic braces.
SEARCH METHODS
An information specialist searched Cochrane Oral Health Trials Register, CENTRAL, MEDLINE, Embase and OpenGrey up to 27 April 2022 and used additional search methods to identify published, unpublished and ongoing studies. SELECTION CRITERIA: Randomised controlled trials (RCTs) involving children and adults who had retainers fitted or adjunctive procedures undertaken to prevent relapse following orthodontic treatment with braces. We excluded studies with aligners.
DATA COLLECTION AND ANALYSIS
Two review authors independently screened eligible studies, assessed risk of bias and extracted data. Outcomes were stability or relapse of tooth position, retainer failure (i.e. broken, detached, worn out, ill-fitting or lost), adverse effects on teeth and gums (i.e. plaque, gingival and bleeding indices), and participant satisfaction. We calculated mean differences (MD) for continuous data, risk ratios (RR) or risk differences (RD) for dichotomous data, and hazard ratios (HR) for survival data, all with 95% confidence intervals (CI). We conducted meta-analyses when similar studies reported outcomes at the same time point; otherwise results were reported as mean ranges. We prioritised reporting of Little's Irregularity Index (crookedness of anterior teeth) to measure relapse, judging the minimum important difference to be 1 mm.
MAIN RESULTS
We included 47 studies, with 4377 participants. The studies evaluated: removable versus fixed retainers (8 studies); different types of fixed retainers (22 studies) or bonding materials (3 studies); and different types of removable retainers (16 studies). Four studies evaluated more than one comparison. We judged 28 studies to have high risk of bias, 11 to have low risk, and eight studies as unclear. We focused on 12-month follow-up. The evidence is low or very low certainty. Most comparisons and outcomes were evaluated in only one study at high risk of bias, and most studies measured outcomes after less than a year. Removable versus fixed retainers Removable (part-time) versus fixed One study reported that participants wearing clear plastic retainers part-time in the lower arch had more relapse than participants with multistrand fixed retainers, but the amount was not clinically significant (Little's Irregularity Index (LII) MD 0.92 mm, 95% CI 0.23 to 1.61; 56 participants). Removable retainers were more likely to cause discomfort (RR 12.22; 95% CI 1.69 to 88.52; 57 participants), but were associated with less retainer failure (RR 0.44, 95% CI 0.20 to 0.98; 57 participants) and better periodontal health (Gingival Index (GI) MD -0.34, 95% CI -0.66 to -0.02; 59 participants). Removable (full-time) versus fixed One study reported that removable clear plastic retainers worn full-time in the lower arch did not provide any clinically significant benefit for tooth stability over fixed retainers (LII MD 0.60 mm, 95% CI 0.17 to 1.03; 84 participants). Participants with clear plastic retainers had better periodontal health (gingival bleeding RR 0.53, 95% CI 0.31 to 0.88; 84 participants), but higher risk of retainer failure (RR 3.42, 95% CI 1.38 to 8.47; 77 participants). The study found no difference between retainers for caries. Different types of fixed retainers Computer-aided design/computer-aided manufacturing (CAD/CAM) nitinol versus conventional/analogue multistrand One study reported that CAD/CAM nitinol fixed retainers were better for tooth stability, but the difference was not clinically significant (LII MD -0.46 mm, 95% CI -0.72 to -0.21; 66 participants). There was no evidence of a difference between retainers for periodontal health (GI MD 0.00, 95% CI -0.16 to 0.16; 2 studies, 107 participants), or retainer survival (RR 1.29, 95% CI 0.67 to 2.49; 1 study, 41 participants). Fibre-reinforced composite versus conventional multistrand/spiral wire One study reported that fibre-reinforced composite fixed retainers provided better stability than multistrand retainers, but this was not of a clinically significant amount (LII MD -0.70 mm, 95% CI -1.17 to -0.23; 52 participants). The fibre-reinforced retainers had better patient satisfaction with aesthetics (MD 1.49 cm on a visual analogue scale, 95% CI 0.76 to 2.22; 1 study, 32 participants), and similar retainer survival rates (RR 1.01, 95% CI 0.84 to 1.21; 7 studies; 1337 participants) at 12 months. However, failures occurred earlier (MD -1.48 months, 95% CI -1.88 to -1.08; 2 studies, 103 participants; 24-month follow-up) and more gingival inflammation at six months, though bleeding on probing (BoP) was similar (GI MD 0.59, 95% CI 0.13 to 1.05; BoP MD 0.33, 95% CI -0.13 to 0.79; 1 study, 40 participants). Different types of removable retainers Clear plastic versus Hawley When worn in the lower arch for six months full-time and six months part-time, clear plastic provided similar stability to Hawley retainers (LII MD 0.01 mm, 95% CI -0.65 to 0.67; 1 study, 30 participants). Hawley retainers had lower risk of failure (RR 0.60, 95% CI 0.43 to 0.83; 1 study, 111 participants), but were less comfortable at six months (VAS MD -1.86 cm, 95% CI -2.19 to -1.53; 1 study, 86 participants). Part-time versus full-time wear of Hawley There was no evidence of a difference in stability between part-time and full-time use of Hawley retainers (MD 0.20 mm, 95% CI -0.28 to 0.68; 1 study, 52 participants).
AUTHORS' CONCLUSIONS
The evidence is low to very low certainty, so we cannot draw firm conclusions about any one approach to retention over another. More high-quality studies are needed that measure tooth stability over at least two years, and measure how long retainers last, patient satisfaction and negative side effects from wearing retainers, such as tooth decay and gum disease.
Topics: Adult; Child; Humans; Orthodontic Brackets; Dental Care; Gingivitis; Periodontal Diseases; Drug-Related Side Effects and Adverse Reactions
PubMed: 37219527
DOI: 10.1002/14651858.CD002283.pub5 -
BMC Oral Health Jul 2022Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also...
BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.
Topics: Artifacts; Humans; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires; Stainless Steel
PubMed: 35854295
DOI: 10.1186/s12903-022-02317-9 -
Children (Basel, Switzerland) Apr 2023Three-dimensional (3D) printing technology has shed light on many fields in medicine and dentistry, including orthodontics. Direct 3D-printed prosthetics, implants or... (Review)
Review
Three-dimensional (3D) printing technology has shed light on many fields in medicine and dentistry, including orthodontics. Direct 3D-printed prosthetics, implants or surgical devices are well-documented. The fabrication of orthodontic retainers using CAD technology and additive manufacturing is an emerging trend but the available data are scarce. The research approach of the present review included keywords in Medline, Scopus, Cochrane Library and Google Scholar up to December 2022. The searching process concluded with five studies eligible for our project. Three of them investigated directly 3D-printed clear retainers in vitro. The other two studies investigated directly 3D-printed fixed retainers. Among them, one study was in vitro and the second was a prospective clinical trial. Directly 3D-printed retainers can be evolved over time as a good alternative to all the conventional materials for retention. Devices that are 3D-printed are more time and cost efficient, offer more comfortable procedures for both practitioners and patients and the materials used in additive manufacturing can solve aesthetic problems, periodontal issues or problems with the interference of these materials with magnetic resonance imaging (MRI). More well-designed prospective clinical trials are necessary for more evaluable results.
PubMed: 37189925
DOI: 10.3390/children10040676 -
Cureus Apr 2024Orthodontists have a variety of options available for retainers. Research in Orthodontics focuses on assessing outcomes important to clinicians; however, there is... (Review)
Review
Orthodontists have a variety of options available for retainers. Research in Orthodontics focuses on assessing outcomes important to clinicians; however, there is inconsistency in how these outcomes are selected and evaluated. This review sought to assess the effects of different orthodontic retainers on patients' quality of life (QoL). Various approaches were employed in this systematic review, and a thorough search was conducted across six databases. The review involved a comprehensive evaluation of six included studies, highlighting changes in dental structure post-treatment, emphasizing the role of extraction procedures and the quality of debonding in improving retention. The study identified key outcomes for orthodontic clinical trials, highlighting orthodontists' preferences for specific retainer types. Moreover, it discussed the impact of sociocultural influences on retention care. Involving patients actively in discussions about whether to end or extend the retention phase was deemed essential. Noteworthy improvements in occlusal outcomes were linked to extraction treatments. Gender and malocclusion severity influenced QoL before and after orthodontic treatment. The degree of improvement observed in the Class III malocclusion group was comparatively lower than that in the Class I and Class II groups. Orthodontic treatment was found to yield favorable psychological outcomes, as evidenced by notable enhancements in self-esteem and social engagement among individuals. Fixed appliances were shown to negatively affect oral health-related quality of life (OHRQoL), particularly for those with aesthetic and functional concerns. A consensus has been reached on the essential themes and outcomes that should be incorporated in clinical trials related to orthodontic retention for non-cleft and non-surgical cases.
PubMed: 38659711
DOI: 10.7759/cureus.58843 -
Journal of Oral Biology and... 2023The aim of this systematic review is to analyze the properties of the different types of orthodontic retainers, identify their differences and define which type of... (Review)
Review
UNLABELLED
The aim of this systematic review is to analyze the properties of the different types of orthodontic retainers, identify their differences and define which type of device is most effective and less harmful to periodontal health.
METHODS
A literature search was carried out by a reviewer by consulting PubMed, Lilacs, Embase, Medline full text, Scopus, Web of Science, Cochrane library, and Science Direct electronic databases for biomedical and health literature as well as the grey literature and setting up the search from December 2010 without any restriction about articles languages.
RESULTS
The results showed that patients who wear retainers for a long period have significant differences in clinical parameters compared to patients without retainers. The type of retainer chosen also significantly influences the overall periodontal health of patients. Fixed retainers, both glass-fibre reinforced and steel wire retainers, proved to be the retainer type with the highest plaque and calculus accumulation values compared to removable retainers. In addition, among fixed retainers, glass-fibre reinforced retainers proved to be those that mostly promote the plaque and calculus accumulation in the application site.
CONCLUSION
Fixed retainers are the best devices to maintain the alignment of mandibular anterior teeth in the long term. Among these devices, stainless steel lingual retainers, plain or braided, should remain the first choice. Although they are also susceptible to periodontal complications, their effect on periodontal health can be considered statistically insignificant if compared to glass-fibre reinforced retainers which, showing worse periodontal complications, should not be used.
PubMed: 36937559
DOI: 10.1016/j.jobcr.2023.02.015 -
Healthcare (Basel, Switzerland) Feb 2022(1) Background and objective: Tooth movements described as unexplained, aberrant, unexpected, unwanted, or undesirable can occur in the presence of an intact orthodontic... (Review)
Review
(1) Background and objective: Tooth movements described as unexplained, aberrant, unexpected, unwanted, or undesirable can occur in the presence of an intact orthodontic retention wire, without detachment or fracture. This iatrogenic phenomenon, known little or not by many practitioners, responsible for significant dental and periodontal complications, both functional and aesthetic, is called "Wire Syndrome" (WS). It is therefore considered an undesirable event of bonded orthodontic retainers, which must be differentiated from an orthodontic relapse. The objective was to perform, for the first time, a systematic review of the literature in order to define the prevalence of WS and to study its associated clinical characteristics. (2) Methods: A systematic review of the literature was performed following the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and recommendations using an electronic search strategy on four databases complemented by a manual search. All the prospective and retrospective clinical studies, including case reports and series, written in English or French, clearly mentioning the description, detection, or management of WS were included. Three independent blinding review authors were involved in study selection, data extraction, and bias assessment using the Mixed Methods Appraisal Tool (MMAT). (3) Results: Of 1891 results, 20 articles published between 2007 and 2021 fulfilled the inclusion criteria, with a globally high risk of bias since 16 articles were case report/series. The analysis of each article allowed the highlighting of WS through 13 categories, as follows: prevalence, apparition delay, patient characteristics, arch and tooth involved, families of movements, dental and periodontal consequences, type of wire, risk factors, etiologies, treatment, and preventive approach. (4) Conclusion: This systematic review of the literature elaborated a synthesis on WS, allowing general practitioners, periodontists, and orthodontists to understand this adverse event, to facilitate the diagnostic approach, and to underline preventive measures against WS. This review was registered in the International Prospective Register of Systematic Reviews (PROSPERO; number CRD42021269297).
PubMed: 35206992
DOI: 10.3390/healthcare10020379 -
Journal of Functional Biomaterials May 2024The objective of this study was to explore the effects of fixed orthodontic appliances on enamel structure by assessing microfractures, surface roughness, and... (Review)
Review
AIM
The objective of this study was to explore the effects of fixed orthodontic appliances on enamel structure by assessing microfractures, surface roughness, and alterations in color.
METHODS
This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic search of online databases was conducted using the keywords 'enamel' AND 'orthodontic debonding'. Eligibility criteria included both in vivo and ex vivo clinical trials conducted on human teeth.
RESULTS AND DISCUSSION
A total of 14 relevant papers were analyzed. Various instruments and techniques were utilized across different studies to assess surface roughness, color change, and surface fractures.
CONCLUSIONS
The findings of this study suggest that ceramic brackets may lead to an increase in enamel fractures, particularly during bracket removal. The surface roughness of enamel exhibits variability depending on the adhesive substance and polishing methods used post-removal. Fixed orthodontic appliances could induce changes in enamel color, which may be alleviated by the use of nano-hydroxyapatite or specific polishing techniques. Further research is necessary to identify effective strategies for managing these color changes and improving the overall outcomes of fixed orthodontic treatment.
PubMed: 38786634
DOI: 10.3390/jfb15050123 -
International Dental Journal Oct 2022The aim of this review was to determine whether the type of removable appliance, as well as the age and sex of the patient, may affect the extension or reduction of wear...
OBJECTIVES
The aim of this review was to determine whether the type of removable appliance, as well as the age and sex of the patient, may affect the extension or reduction of wear time by assessing the correlation between the mean actual and orthodontist-recommended wear times.
METHODS
Randomised case control trials, cohort studies, case series, observational studies, reviews, and retrospective analyses were identified. The quality of the studies was assessed using the Cochrane Collaboration Tool and modified Newcastle-Ottawa Scale. The electronic databases Embase, PubMed, Scopus, and Web of Science were reviewed, and 542 articles were obtained, of which 31 were qualified for qualitative synthesis. The data from 1674 participants were collected and a weighted average was determined for the mean wear time of each appliance.
RESULTS
Regardless of the type of extra- or intraoral appliances, mean wear time was shorter than recommended, although patients using intraoral appliances cooperated more. The best compliance was noted for Schwarz appliances (73.70%) and plate retainers (85%). There was no evidence of an influence of patients' age and sex on compliance during treatment.
CONCLUSIONS
The considerable inconsistency and imprecision of articles could affect the reliability of the results. Previous studies analysing the effectiveness of treatment with removable appliances based on an arbitrarily assumed average wear time need to be revised in order to verify the actual wear time with the use of microsensors.
Topics: Case-Control Studies; Humans; Orthodontic Appliances, Removable; Patient Compliance; Reproducibility of Results; Retrospective Studies
PubMed: 35961844
DOI: 10.1016/j.identj.2022.07.004