Chiropractic & Manual Therapies Dec 2022Clinicians rely on certain physical examination tests to diagnose and potentially grade ankle sprains and ankle instability. Diagnostic error and inaccurate prognosis...
INTRODUCTION
Clinicians rely on certain physical examination tests to diagnose and potentially grade ankle sprains and ankle instability. Diagnostic error and inaccurate prognosis may have important repercussions for clinical decision-making and patient outcomes. Therefore, it is important to recognize the diagnostic value of orthopaedic tests through understanding the reliability and validity of these tests.
OBJECTIVE
To systematically review and report evidence on the reliability and validity of orthopaedic tests for the diagnosis of ankle sprains and instability.
METHODS
PubMed, CINAHL, Scopus, and Cochrane databases were searched from inception to December 2021. In addition, the reference list of included studies, located systematic reviews, and orthopaedic textbooks were searched. All articles reporting reliability or validity of physical examination or orthopaedic tests to diagnose ankle instability or sprains were included. Methodological quality of the reliability and the validity studies was assessed with The Quality Appraisal for Reliability studies checklist and the Quality Assessment of Diagnostic Accuracy Studies-2 respectively. We identified the number of times the orthopaedic test was investigated and the validity and/or reliability of each test.
RESULTS
Overall, sixteen studies were included. Three studies assessed reliability, eight assessed validity, and five evaluated both. Overall, fifteen tests were evaluated, none demonstrated robust reliability and validity scores. The anterolateral talar palpation test reported the highest diagnostic accuracy. Further, the anterior drawer test, the anterolateral talar palpation, the reverse anterior lateral drawer test, and palpation of the anterior talofibular ligament reported the highest sensitivity. The highest specificity was attributed to the anterior drawer test, the anterolateral drawer test, the reverse anterior lateral drawer test, tenderness on palpation of the proximal fibular, and the squeeze test.
CONCLUSION
Overall, the diagnostic accuracy, reliability, and validity of physical examination tests for the assessment of ankle instability were limited. Physical examination tests should not be used in isolation, but rather in combination with the clinical history to diagnose an ankle sprain. Preliminary evidence suggests that the overall validity of physical examination for the ankle may be better if conducted five days after the injury rather than within 48 h of injury.
Topics: Humans; Ankle; Reproducibility of Results; Ankle Joint; Physical Examination; Joint Instability; Ankle Injuries
PubMed: 36536446
DOI: 10.1186/s12998-022-00470-0 -
JPMA. the Journal of the Pakistan... Apr 2023To determine the sensitivity and specificity of the clinical diagnostic tests of subacromial impingement syndrome.
OBJECTIVE
To determine the sensitivity and specificity of the clinical diagnostic tests of subacromial impingement syndrome.
METHODS
The systematic review comprised search on PubMed, PEDro, Cochrane Library and Google Scholar databases. For prospective cohort studies published in peer-reviewed English-language journals without any time limit, at least fully describing one clinical test. Only studies with free full text available were included. Data extracted included sensitivity and specificity for each clinical test, and variations were sorted out by the 3 reviewers by discussion.
RESULTS
Of the 4137 studies identified, 2951(71.3%) were on PubMed, 119(2.9%) PEDro, 5(0.1%) Cochrane Library and 1062(25.7%) Google Scholar. After screening out all the studies that did not match the detailed inclusion criterion, 3(0.07%) studies were selected for review; 1(33.3%) each done in Spain, Turkey and France. Overall, there were 181 aged 15-82 years; 85(47%) males and 96(53%) females. Supraspinatus palpation test had a sensitivity of 92%, while the modified Neer test had specificity of 95.56% in terms of ruling out subacromial impingement syndrome.
CONCLUSIONS
Supraspinatus palpation and modified Neer tests were found to be the most effective in the diagnosis of subacromial impingement syndrome.
Topics: Female; Humans; Male; Physical Examination; Prospective Studies; Rotator Cuff; Sensitivity and Specificity; Shoulder Impingement Syndrome; Adolescent; Young Adult; Adult; Middle Aged; Aged; Aged, 80 and over
PubMed: 37051997
DOI: 10.47391/JPMA.5529 -
BMC Women's Health Nov 2023Childbirth is one of the biggest risk factors for incontinence. Urinary and anal incontinence can cause pain and social limitations that affect social life,...
BACKGROUND
Childbirth is one of the biggest risk factors for incontinence. Urinary and anal incontinence can cause pain and social limitations that affect social life, cohabitation, and work. There is currently no up-to-date literature study on the effect of pelvic floor muscle training with feedback from a physiotherapist, which involves verbal instructions based on vaginal and anal digital palpation, compared to treatment without feedback (e.g., recommendations for pelvic floor muscle training).
AIM
The objective of this systematic review was to examine the scientific evidence regarding the impact of pelvic floor muscle training (PFMT) with feedback from a physiotherapist and/or biofeedback on urinary and anal incontinence in women during the first six months following vaginal delivery, compared to treatment without feedback.
METHODS
The literature search was conducted in the databases PubMed, Cochrane, and CINAHL. In addition, a manual search was conducted. The search terms consisted of MeSH terms and synonyms in the respective search block including population, intervention, and study design, as well as the terms pelvic floor and postpartum. An evaluation of each included study was conducted for methodological quality, evidence value, and clinical relevance.
RESULTS
Eight studies were included, three of which showed a significant difference between groups, in favor of the intervention group that received pelvic floor muscle training with feedback from a physiotherapist and/or biofeedback. Due to the varying results and insufficient quality for the majority of the studies, the scientific basis was considered insufficient.
CONCLUSION
The scientific evidence for pelvic floor muscle training with feedback from a physiotherapist or biofeedback on postpartum urinary and anal incontinence compared to treatment without feedback is considered insufficient. Further research on the subject is needed. The study is registered in PROSPERO CRD42022361296.
Topics: Pregnancy; Female; Humans; Pelvic Floor; Feedback; Physical Therapists; Exercise Therapy; Biofeedback, Psychology; Delivery, Obstetric; Fecal Incontinence; Urinary Incontinence, Stress; Treatment Outcome
PubMed: 37980530
DOI: 10.1186/s12905-023-02765-7 -
Rheumatology International Sep 2023This systematic review is aimed to evaluate the effects of balneotherapy with thermal mineral water for managing the symptoms and signs of osteoarthritis located at any...
This systematic review is aimed to evaluate the effects of balneotherapy with thermal mineral water for managing the symptoms and signs of osteoarthritis located at any anatomical site. The systematic review was conducted according to the PRISMA Statement. The following databases were consulted: PubMed, Scopus, Web of Science, Cochrane Library, DOAJ and PEDro. We included clinical trials evaluating the effects of balneotherapy as a treatment for patients with osteoarthritis, published in English and Italian language, led on human subjects. The protocol was registered in PROSPERO. Overall, 17 studies have been included in the review. All of these studies were performed on adults or elderly patients suffering from osteoarthritis localized to knees, hips, hands or lumbar spine. The treatment assessed was always the balneotherapy with thermal mineral water. The outcomes evaluated were pain, palpation/pressure sensibility, articular tenderness, functional ability, quality of life, mobility, deambulation, ability to climb stairs, medical objective and patients' subjective evaluation, superoxide dismutase enzyme activity, serum levels of interleukin-2 receptors. The results of all the included studies agree and demonstrated an improvement of all the symptoms and signs investigated. In particular, pain and quality of life were the main symptoms evaluated and both improved after the treatment with thermal water in all the studies included in the review. These effects can be attributed to physical and chemical-physical properties of thermal mineral water used. However, the quality of many studies resulted not so high due and, consequently, it is necessary to perform new clinical trial in this field using more correct methods for conducting the study and for processing statistical data.
Topics: Humans; Aged; Quality of Life; Balneology; Osteoarthritis; Mineral Waters; Pain
PubMed: 37301799
DOI: 10.1007/s00296-023-05358-7 -
The Cochrane Database of Systematic... Mar 2023In arterial line cannulation in children and adolescents, traditional methods of locating the artery include palpation and Doppler auditory assistance. It is unclear... (Review)
Review
BACKGROUND
In arterial line cannulation in children and adolescents, traditional methods of locating the artery include palpation and Doppler auditory assistance. It is unclear whether ultrasound guidance is superior to these methods. This is an update of a review originally published in 2016.
OBJECTIVES
To evaluate the benefits and harms of ultrasound guidance compared with traditional techniques (palpation, Doppler auditory assistance) for assisting arterial line placement at all potential sites in children and adolescents.
SEARCH METHODS
We searched CENTRAL, MEDLINE, Embase, and Web of Science from inception to 30 October 2022. We also searched four trials registers for ongoing trials, and we checked the reference lists of included studies and relevant reviews for other potentially eligible trials.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) comparing ultrasound guidance versus other techniques (palpation or Doppler auditory assistance) to guide arterial line cannulation in children and adolescents (aged under 18 years). We planned to include quasi-RCTs and cluster-RCTs. For RCTs with both adult and paediatric populations, we planned to include only the paediatric population data.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed the risk of bias of included trials and extracted data. We used standard Cochrane meta-analytical procedures, and we applied the GRADE method to assess the certainty of evidence.
MAIN RESULTS
We included nine RCTs reporting 748 arterial cannulations in children and adolescents (under 18 years of age) undergoing different surgical procedures. Eight RCTs compared ultrasound with palpation, and one compared ultrasound with Doppler auditory assistance. Five studies reported the incidence of haematomas. Seven involved radial artery cannulation and two involved femoral artery cannulation. The people performing arterial cannulation were physicians with different levels of experience. The risk of bias varied across studies, with some studies lacking details of allocation concealment. It was not possible to blind practitioners in any case; this adds a performance bias that is inherent to the type of intervention studied in our review. Compared to traditional methods, ultrasound guidance probably causes a large increase in first-attempt success rates (risk ratio (RR) 2.01, 95% confidence interval (CI) 1.64 to 2.46; 8 RCTs, 708 participants; moderate-certainty evidence) and probably causes a large reduction in the risk of complications such as haematoma formation (RR 0.26, 95% CI 0.14 to 0.47; 5 RCTs, 420 participants; moderate-certainty evidence). No studies reported data about ischaemic damage. Ultrasound guidance probably improves success rates within two attempts (RR 1.78, 95% CI 1.25 to 2.51; 2 RCTs, 134 participants; moderate-certainty evidence) and overall rate of successful cannulation (RR 1.32, 95% CI 1.10 to 1.59; 6 RCTs, 374 participants; moderate-certainty evidence). In addition, ultrasound guidance probably reduces the number of attempts to successful cannulation (mean difference (MD) -0.99 attempts, 95% CI -1.15 to -0.83; 5 RCTs, 368 participants; moderate-certainty evidence) and duration of the cannulation procedure (MD -98.77 seconds, 95% CI -150.02 to -47.52, 5 RCTs, 402 participants; moderate-certainty evidence). More studies are needed to confirm whether the improvement in first-attempt success rates is more pronounced in neonates and younger children compared to older children and adolescents.
AUTHORS' CONCLUSIONS
We identified moderate-certainty evidence that ultrasound guidance for arterial cannulation compared with palpation or Doppler auditory assistance improves first-attempt success rate, second-attempt success rate and overall success rate. We also found moderate-certainty evidence that ultrasound guidance reduces the incidence of complications, the number of attempts to successful cannulation and the duration of the cannulation procedure.
Topics: Adolescent; Adult; Child; Infant, Newborn; Humans; Aged; Ultrasonography; Arteries; Hematoma; Catheterization; Ultrasonography, Interventional
PubMed: 36866968
DOI: 10.1002/14651858.CD011364.pub3 -
International Urogynecology Journal Sep 2022Myofascial pain arising from pelvic floor muscles occurs in women with vaginismus, interstitial cystitis and endometriosis but is often overlooked. The aim is to examine... (Review)
Review
INTRODUCTION AND HYPOTHESIS
Myofascial pain arising from pelvic floor muscles occurs in women with vaginismus, interstitial cystitis and endometriosis but is often overlooked. The aim is to examine alternative diagnostic tests to detect pelvic floor myofascial pain compared with standardized vaginal palpation of pelvic floor muscles as the reference test.
METHODS
A systematic review was prospectively conducted (PROSPERO-CRD42020183092) according to PRISMA guidelines. Databases searched included Ovid Medline 1946-, Embase 1957-, Scopus 1960-, Cochrane Combined, Clinical trials, Google Scholar (top 200 articles), Web of Science, TRIP, BIOSIS, DARE, CINHAL, EmCare, PEDro, ProQuest and EBSCOhost up to July 2020. Articles were independently screened by two authors and assessed for bias using QUASDAS-2 tool.
RESULTS
A total of 26,778 articles were screened and 177 were selected for full text review, of which 5 were selected for final analysis. Five studies included 9694 participants of which 1628 had pelvic floor myofascial pain. Only one study reported data to calculate sensitivities and specificities of the index test, which utilized a score of > 40 on the Central Sensitization Inventory to detect women with pelvic floor myofascial pain and revealed a sensitivity of 34.8% and a specificity of 84.9% compared to the reference test.
CONCLUSIONS
This systematic review did not reveal any diagnostic test superior to the pre-defined reference test. There is a lack of consensus on the definition of pelvic floor myofascial pain and a lack of a validated diagnostic criteria which must be addressed to progress with meaningful research in this field.
Topics: Diagnostic Tests, Routine; Endometriosis; Female; Humans; Myofascial Pain Syndromes; Pain; Pelvic Floor
PubMed: 35796787
DOI: 10.1007/s00192-022-05258-7 -
The British Journal of Radiology Oct 2022Although infantile hypertrophic pyloric stenosis (IHPS) is a well-known disease, there is no systematic review regarding the optimal diagnostic strategy. We conducted a... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Although infantile hypertrophic pyloric stenosis (IHPS) is a well-known disease, there is no systematic review regarding the optimal diagnostic strategy. We conducted a systematic review and meta-analysis to obtain diagnostic accuracy of all methods to diagnose IHPS.
METHODS
According to the Preferred Reported Items for Systematic Reviews and Meta-Analysis guidelines, we searched MEDLINE and Embase to identify studies reporting sensitivity and specificity of all methods used to diagnose IHPS. Inclusion criteria were infants with suspicion of/or diagnosed with IHPS who underwent pyloromyotomy or had clinical follow-up. A random-effects model was used to obtain pooled estimates of sensitivity, specificity and area under the receiver operating characteristic curve.
RESULTS
After screening 5364 studies, we included 43 studies with in total 6085 infants ( = 4241 IHPS; = 1844 controls). The diagnostic sensitivity of palpation ranged from 10.0 to 93.4% and decreased over time. Different parameters for ultrasonography were found. Most used parameters were pyloric muscle thickness (PMT) ≥ 3 mm (pooled sensitivity 97.6% and specificity 98.8%), PMT ≥ 4 mm (pooled sensitivity 94.0% and specificity 98.0%) or a combination of PMT ≥ 4 mm and/or pyloric canal length ≥16 mm (pooled sensitivity 94.0% and specificity 91.7%). The AUC showed high diagnostic accuracy (0.997, 0.966 and 0.981 respectively), but large heterogeneity exists. Due to the large differences in cut-off values no meta-analysis could be conducted for pyloric canal length and pyloric diameter.
CONCLUSION
Palpation has limited sensitivity in diagnosing IHPS. We showed that ultrasonography has highest diagnostic accuracy to diagnose IHPS and we advise to use PMT ≥ 3 mm as cut-off.
ADVANCES IN KNOWLEDGE
This is the first systematic review and meta-analysis on diagnosing IHPS, which summarizes the available literature and may be used as a guideline.
Topics: Humans; Infant; Pyloric Stenosis, Hypertrophic; Ultrasonography; Palpation; Sensitivity and Specificity
PubMed: 36043474
DOI: 10.1259/bjr.20211251 -
The Cochrane Database of Systematic... Oct 2021Arterial vascular access is a frequently performed procedure, with a high possibility for adverse events (e.g. pneumothorax, haemothorax, haematoma, amputation, death),... (Review)
Review
BACKGROUND
Arterial vascular access is a frequently performed procedure, with a high possibility for adverse events (e.g. pneumothorax, haemothorax, haematoma, amputation, death), and additional techniques such as ultrasound may be useful for improving outcomes. However, ultrasound guidance for arterial access in adults is still under debate.
OBJECTIVES
To assess the effects of ultrasound guidance for arterial (other than femoral) catheterisation in adults.
SEARCH METHODS
We searched CENTRAL, MEDLINE, Embase, LILACS, and CINAHL on 21 May 2021. We also searched IBECS, WHO ICTRP, and ClinicalTrials.gov on 16 June 2021, and we checked the reference lists of retrieved articles.
SELECTION CRITERIA
Randomised controlled trials (RCTs), including cross-over trials and cluster-RCTs, comparing ultrasound guidance, alone or associated with other forms of guidance, versus other interventions or palpation and landmarks for arterial (other than femoral) guidance in adults.
DATA COLLECTION AND ANALYSIS
Two review authors independently performed study selection, extracted data, assessed risk of bias, and assessed the certainty of evidence using GRADE.
MAIN RESULTS
We included 48 studies (7997 participants) that tested palpation and landmarks, Doppler auditory ultrasound assistance (DUA), direct ultrasound guidance with B-mode, or any other modified ultrasound technique for arterial (axillary, dorsalis pedis, and radial) catheterisation in adults. Radial artery Real-time B-mode ultrasound versus palpation and landmarks Real-time B-mode ultrasound guidance may improve first attempt success rate (risk ratio (RR) 1.44, 95% confidence interval (CI) 1.29 to 1.61; 4708 participants, 27 studies; low-certainty evidence) and overall success rate (RR 1.11, 95% CI 1.06 to 1.16; 4955 participants, 28 studies; low-certainty evidence), and may decrease time needed for a successful procedure (mean difference (MD) -0.33 minutes, 95% CI -0.54 to -0.13; 4902 participants, 26 studies; low-certainty evidence) up to one hour compared to palpation and landmarks. Real-time B-mode ultrasound guidance probably decreases major haematomas (RR 0.35, 95% CI 0.23 to 0.56; 2504 participants, 16 studies; moderate-certainty evidence). It is uncertain whether real-time B-mode ultrasound guidance has any effect on pseudoaneurysm, pain, and quality of life (QoL) compared to palpation and landmarks (very low-certainty evidence). Real-time B-mode ultrasound versus DUA One study (493 participants) showed that real-time B-mode ultrasound guidance probably improves first attempt success rate (RR 1.35, 95% CI 1.11 to 1.64; moderate-certainty evidence) and time needed for a successful procedure (MD -1.57 minutes, 95% CI -1.78 to -1.36; moderate-certainty evidence) up to 72 hours compared to DUA. Real-time B-mode ultrasound guidance may improve overall success rate (RR 1.13, 95% CI 0.99 to 1.29; low-certainty evidence) up to 72 hours compared to DUA. Pseudoaneurysm, major haematomas, pain, and QoL were not reported. Real-time B-mode ultrasound versus modified real-time B-mode ultrasound Real-time B-mode ultrasound guidance may decrease first attempt success rate (RR 0.68, 95% CI 0.55 to 0.84; 153 participants, 2 studies; low-certainty evidence), may decrease overall success rate (RR 0.93, 95% CI 0.86 to 1.01; 153 participants, 2 studies; low-certainty evidence), and may lead to no difference in time needed for a successful procedure (MD 0.04 minutes, 95% CI -0.01 to 0.09; 153 participants, 2 studies; low-certainty evidence) up to one hour compared to modified real-time B-mode ultrasound guidance. It is uncertain whether real-time B-mode ultrasound guidance has any effect on major haematomas compared to modified real-time B-mode ultrasound (very low-certainty evidence). Pseudoaneurysm, pain, and QoL were not reported. In-plane versus out-of-plane B-mode ultrasound In-plane real-time B-mode ultrasound guidance may lead to no difference in overall success rate (RR 1.00, 95% CI 0.96 to 1.05; 1051 participants, 8 studies; low-certainty evidence) and in time needed for a successful procedure (MD -0.06 minutes, 95% CI -0.16 to 0.05; 1134 participants, 9 studies; low-certainty evidence) compared to out-of-plane B-mode ultrasound up to one hour. It is uncertain whether in-plane real-time B-mode ultrasound guidance has any effect on first attempt success rate or major haematomas compared to out-of-plane B-mode ultrasound (very low-certainty evidence). Pseudoaneurysm, pain, and QoL were not reported. DUA versus palpation and landmarks DUA may lead to no difference in first attempt success rate (RR 1.01, 95% CI 0.90 to 1.14; 666 participants, 2 studies; low-certainty evidence) or overall success rate (RR 0.99, 95% CI 0.92 to 1.07; 666 participants, 2 studies; low-certainty evidence) and probably increases time needed for a successful procedure (MD 0.45 minutes, 95% CI 0.20 to 0.70; 500 participants, 1 study; moderate-certainty evidence) up to 72 hours compared to palpation and landmarks. Pseudoaneurysm, major haematomas, pain, and QoL were not reported. Oblique-axis versus long-axis in-plane B-mode ultrasound Oblique-axis in-plane B-mode ultrasound guidance may increase overall success rate (RR 1.27, 95% CI 1.05 to 1.53; 215 participants, 2 studies; low-certainty evidence) up to 72 hours compared to long-axis in-plane B-mode ultrasound. It is uncertain whether oblique-axis in-plane B-mode ultrasound guidance has any effect on first attempt success rate, time needed for a successful procedure, and major haematomas compared to long-axis in-plane B-mode ultrasound. Pseudoaneurysm, pain, and QoL were not reported. We are uncertain about effects in the following comparisons due to very low-certainty evidence and unreported outcomes: real-time B-mode ultrasound versus palpation and landmarks (axillary and dorsalis pedis arteries), real-time B-mode ultrasound versus near-infrared laser (radial artery), and dynamic versus static out-of-plane B-mode ultrasound (radial artery).
AUTHORS' CONCLUSIONS
Real-time B-mode ultrasound guidance may improve first attempt success rate, overall success rate, and time needed for a successful procedure for radial artery catheterisation compared to palpation, or DUA. In addition, real-time B-mode ultrasound guidance probably decreases major haematomas compared to palpation. However, we are uncertain about the evidence on major haematomas and pain for other comparisons due to very low-certainty evidence and unreported outcomes. We are also uncertain about the effects on pseudoaneurysm and QoL for axillary and dorsalis pedis arteries catheterisation. Given that first attempt success rate and pseudoaneurysm are the most relevant outcomes for people who underwent arterial catheterisation, future studies must measure both. Future trials must be large enough to detect effects, use validated scales, and report longer-term follow-up.
Topics: Adult; Arteries; Catheterization; Humans; Ultrasonography
PubMed: 34637140
DOI: 10.1002/14651858.CD013585.pub2 -
Medical Ultrasonography Sep 2023Flexibility and dynamic perspective of ultrasound imaging allow for a targeted/focused examination, yielding extra find-ings. Sonopalpation - also referred as sono-Tinel...
Flexibility and dynamic perspective of ultrasound imaging allow for a targeted/focused examination, yielding extra find-ings. Sonopalpation - also referred as sono-Tinel for nerves - is one of those particular features of ultrasound examination whereby the ultrasound probe is actively 'manipulated'. It is paramount to ascertain the painful structure/pathology during the evaluation of a patient and it is not possible with other imaging techniques other than ultrasonography. In this aspect, the cur-rent review aims to provide an analysis of the literature regarding the use of sonopalpation for clinical and research purposes respectively.
Topics: Humans; Ultrasonography; Musculoskeletal System
PubMed: 37369030
DOI: 10.11152/mu-4060 -
Resuscitation Plus Sep 2024To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. (Review)
Review
AIM
To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth.
METHODS
A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence.
RESULTS
Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes.
LIMITATIONS
Certainty of evidence was low or very low for most comparisons.
CONCLUSION
If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.
PubMed: 38912532
DOI: 10.1016/j.resplu.2024.100668