-
Addiction Science & Clinical Practice Oct 2021Methamphetamine/amphetamine use has sharply increased among people with opioid use disorder (OUD). It is therefore important to understand whether and how use of these... (Review)
Review
BACKGROUND
Methamphetamine/amphetamine use has sharply increased among people with opioid use disorder (OUD). It is therefore important to understand whether and how use of these substances may impact receipt of, and outcomes associated with, medications for OUD (MOUD). This systematic review identified studies that examined associations between methamphetamine/amphetamine use or use disorder and 3 classes of outcomes: (1) receipt of MOUD, (2) retention in MOUD, and (3) opioid abstinence during MOUD.
METHODS
We searched 3 databases (PubMed/MEDLINE, PsycINFO, CINAHL Complete) from 1/1/2000 to 7/28/2020 using key words and subject headings, and hand-searched reference lists of included articles. English-language studies of people with documented OUD/opioid use that reported a quantitative association between methamphetamine/amphetamine use or use disorder and an outcome of interest were included. Study data were extracted using a standardized template, and risk of bias was assessed for each study. Screening, inclusion, data extraction and bias assessment were conducted independently by 2 authors. Study characteristics and findings were summarized for each class of outcomes.
RESULTS
Thirty-nine studies met inclusion criteria. Studies generally found that methamphetamine/amphetamine use or use disorder was negatively associated with receiving methadone and buprenorphine; 2 studies suggested positive associations with receiving naltrexone. Studies generally found negative associations with retention; most studies finding no association had small samples, and these studies tended to examine shorter retention timeframes and describe provision of adjunctive services to address substance use. Studies generally found negative associations with opioid abstinence during treatment among patients receiving methadone or sustained-release naltrexone implants, though observed associations may have been confounded by other polysubstance use. Most studies examining opioid abstinence during other types of MOUD treatment had small samples.
CONCLUSIONS
Overall, existing research suggests people who use methamphetamine/amphetamines may have lower receipt of MOUD, retention in MOUD, and opioid abstinence during MOUD. Future research should examine how specific policies and treatment models impact MOUD outcomes for these patients, and seek to understand the perspectives of MOUD providers and people who use both opioids and methamphetamine/amphetamines. Efforts to improve MOUD care and overdose prevention strategies are needed for this population.
Topics: Buprenorphine; Humans; Methadone; Methamphetamine; Opiate Substitution Treatment; Opioid-Related Disorders
PubMed: 34635170
DOI: 10.1186/s13722-021-00266-2 -
The Cochrane Database of Systematic... Nov 2020Diabetic macular edema (DME) is secondary to leakage from diseased retinal capillaries with thickening of central retina, and is an important cause of poor central... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Diabetic macular edema (DME) is secondary to leakage from diseased retinal capillaries with thickening of central retina, and is an important cause of poor central visual acuity in people with diabetic retinopathy. Intravitreal steroids have been used to reduce retinal thickness and improve vision in people with DME.
OBJECTIVES
To assess the effectiveness and safety of intravitreal steroid therapy compared with other treatments for DME.
SEARCH METHODS
We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, and Embase on 15 May, 2019. We also searched reference lists, Science Citation Index, conference proceedings, and relevant trial registers. We conducted a top up search on 21 October, 2020.
SELECTION CRITERIA
We included randomized controlled trials that evaluated any type of intravitreal steroids as monotherapy against any other intervention (e.g. observation, laser photocoagulation, anti-vascular endothelial growth factor (antiVEGF) for DME.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed study eligibility and risk of bias and extracted data. Where appropriate, we performed meta-analyses.
MAIN RESULTS
We included 10 trials (4348 participants, 4505 eyes). These trials compared intravitreal steroid therapies versus other treatments, including intravitreal antiVEGF therapy, laser photocoagulation, and sham injection. Most trials had an overall unclear or high risk of bias. One trial (701 eyes ) compared intravitreal dexamethasone implant 0.7mg with sham. We found moderate-certainty evidence that dexamethasone leads to slightly more improvement of visual acuity than sham at 12 months (mean difference [MD] -0.08 logMAR, 95% confidence interval [CI] -0.12 to -0.05 logMAR). Regarding improvement of three or more lines of visual acuity, there was moderate-certainty evidence in favor of dexamethasone at 12 months, but the CI covered the null value (risk ratio (RR) 1.39, 95% CI 0.91 to 2.12). Regarding adverse events, dexamethasone increased by about four times the risk of cataract progression and the risk of using intraocular pressure (IOP)-lowering medications compared to sham (RR 3.89, 95% CI 2.75 to 5.50 and RR 4.54, 95% CI 3.19 to 6.46, respectively; moderate-certainty evidence); about 4 in 10 participants treated with dexamethasone needed IOP-lowering medications. Two trials (451 eyes) compared intravitreal dexamethasone implant 0.7mg with intravitreal antiVEGF (bevacizumab and ranibizumab). There was moderate-certainty evidence that visual acuity improved slightly less with dexamethasone compared with antiVEGF at 12 months (MD 0.07 logMAR, 95% CI 0.04 to 0.09 logMAR; 2 trials; 451 participants/eyes; I = 0%). The RR of gain of three or more lines of visual acuity was inconsistent between trials, with one trial finding no evidence of a difference between dexamethasone and bevacizumab at 12 months (RR 0.99, 95% CI 0.70 to 1.40; 1 trial; 88 eyes), and the other, larger trial finding the chances of vision gain were half with dexamethasone compared with ranibizumab (RR 0.50, 95% CI 0.32 to 0.79; 1 trial; 432 participants). The certainty of evidence was low. Cataract progression and the need for IOP-lowering medications increased more than 4 times with dexamethasone implant compared to antiVEGF (moderate-certainty evidence). One trial (560 eyes) compared intravitreal fluocinolone implant 0.19mg with sham. There was moderate-certainty evidence that visual acuity improved slightly more with fluocinolone at 12 months (MD -0.04 logMAR, 95% CI -0.06 to -0.01 logMAR). There was moderate-certainty evidence that an improvement in visual acuity of three or more lines was more common with fluocinolone than with sham at 12 months (RR 1.79, 95% CI 1.16 to 2.78). Fluocinolone also increased the risk of cataract progression (RR 1.63, 95% CI 1.35 to 1.97; participants = 335; moderate-certainty evidence), which occurred in about 8 in 10 participants, and the use of IOP-lowering medications (RR 2.72, 95% CI 1.87 to 3.98; participants = 558; moderate-certainty evidence), which were needed in 2 to 3 out of 10 participants. One small trial with 43 participants (69 eyes) compared intravitreal triamcinolone acetonide injection 4 mg with sham. There may be a benefit in visual acuity at 24 months (MD -0.11 logMAR, 95% CI -0.20 to -0.03 logMAR), but the certainty of evidence is low. Differences in adverse effects were poorly reported in this trial. Two trials (615 eyes) compared intravitreal triamcinolone acetonide injection 4mg with laser photocoagulation and reached discordant results. The smaller trial (31 eyes followed up to 9 months) found more visual acuity improvement with triamcinolone (MD -0.18 logMAR, 95% CI -0.29 to -0.07 logMAR), but a larger, multicenter trial (584 eyes, 12-month follow-up) found no evidence of a difference regarding change in visual acuity (MD 0.02 logMAR, 95% CI -0.03 to 0.07 logMAR) or gain of three or more lines of visual acuity (RR 0.85, 95% CI 0.55 to 1.30) (overall low-certainty evidence). Cataract progression was about three times more likely (RR 2.68, 95% CI 2.21 to 3.24; moderate-certainty evidence) and the use of IOP-lowering medications was about four times more likely (RR 3.92, 95% CI 2.59 to 5.96; participants = 627; studies = 2; I = 0%; moderate-certainty evidence) with triamcinolone. About 1 in 3 participants needed IOP-lowering medication. One small trial (30 eyes) compared intravitreal triamcinolone acetonide injection 4mg with intravitreal antiVEGF (bevacizumab or ranibizumab). Visual acuity may be worse with triamcinolone at 12 months (MD 0.18 logMAR, 95% CI 0.10 to 0.26 logMAR); the certainty of evidence is low. Adverse effects were poorly reported in this trial. Four trials reported data on pseudophakic participants, for whom cataract is not a concern. These trials found no decrease in visual acuity in the second treatment year due to cataract progression.
AUTHORS' CONCLUSIONS
Intravitreal steroids may improve vision in people with DME compared to sham or control. Effects were small, about one line of vision or less in most comparisons. More evidence is available for dexamethasone or fluocinolone implants when compared to sham, and the evidence is limited and inconsistent for the comparison of dexamethasone with antiVEGF treatment. Any benefits should be weighed against IOP elevation, the use of IOP-lowering medication and, in phakic patients, the progression of cataract. The need for glaucoma surgery is also increased, but remains rare.
Topics: Anti-Inflammatory Agents; Bevacizumab; Bias; Confidence Intervals; Dexamethasone; Diabetic Retinopathy; Drug Implants; Fluocinolone Acetonide; Glucocorticoids; Humans; Intravitreal Injections; Macular Edema; Randomized Controlled Trials as Topic; Ranibizumab; Steroids; Triamcinolone; Vascular Endothelial Growth Factor A; Visual Acuity; Vitreous Body
PubMed: 33206392
DOI: 10.1002/14651858.CD005656.pub3 -
Frontiers in Endocrinology 2024The aim of this study was to better understand the efficacy of various drugs, such as glucocorticoids and anti-vascular endothelial growth factors (VEGF), in the... (Comparative Study)
Comparative Study
INTRODUCTION
The aim of this study was to better understand the efficacy of various drugs, such as glucocorticoids and anti-vascular endothelial growth factors (VEGF), in the treatment of diabetic macular edema (DME), and to evaluate various clinical treatment regimens consisting of different therapeutic measures.
METHODS
This study included randomized controlled trials up to February 2023 comparing the efficacy of corticosteroid-related therapy and anti-VEGF therapy. PubMed, the Cochrane Library, and Embase were searched, and the quality of the studies was carefully assessed. Finally, 39 studies were included.
RESULTS
Results at 3-month followup showed that intravitreal injection of bevacizumab (IVB) + triamcinolone acetonide (TA) was the most beneficial in improving best-corrected visual acuity and reducing the thickness of macular edema in the center of the retina in patients with DME. Results at 6-month follow-up showed that intravitreal dexamethasone (DEX) was the most effective in improving patients' bestcorrected visual acuity and reducing the thickness of central macular edema.
DISCUSSION
Overall, IVB+TA was beneficial in improving best-corrected visual acuity and reducing central macular edema thickness over a 3-month follow-up period, while DEX implants had a better therapeutic effect than anti-VEGF agents at 6 months, especially the patients with severe macular edema and visual acuity impaired.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/PROSPERO/display_record.php?RecordID=397100, identifier CRD42023397100.
Topics: Humans; Diabetes Mellitus; Diabetic Retinopathy; Glucocorticoids; Macular Edema; Randomized Controlled Trials as Topic; Triamcinolone Acetonide; Vascular Endothelial Growth Factor A
PubMed: 38586457
DOI: 10.3389/fendo.2024.1342530 -
Medicina (Kaunas, Lithuania) Jul 2020Since silicone breast implants were introduced to the market several decades ago, the safety of breast implants has remained controversial. Recently, several studies...
Since silicone breast implants were introduced to the market several decades ago, the safety of breast implants has remained controversial. Recently, several studies have explored breast implant-associated anaplastic large-cell lymphoma (BIA-ALCL) and breast implant illness (BII). Several countries have developed national breast implant registries to improve the safety and quality of breast implant surgery. We performed a systematic review of the current status of national breast implant registries and propose a pilot form of an appropriate breast implant registry model for Korea. The systematic review was conducted in accordance with the "preferred reporting items for systematic reviews and meta-analyses (PRISMA) pro forma". PubMed and Google Scholar databases were searched to identify all articles containing information on national breast implant registries. We limited the search to articles written in the English language from 2010 to 2020. Articles were reviewed by two independent authors. A total of 63 articles related to national breast implant registries, registry principles and national breast implant registry annual reports were identified. After reviewing the literature, 25 national breast implant registry-related articles were included in the full-text synthesis. Currently, four countries, The Netherlands, Australia, Sweden, and the UK, have breast implant registries with well-formed sources for big data. Overall, similarities in data points were detected for three categories: implant-related complications, operation details, and device information. However, there were differences for each registry in terms of governance, funding, and capture rate. After reviewing other countries' experiences, tentative datasets for the Korean Breast Implant Registry (K-BIR) were developed. The K-BIR can improve the quality of breast implant surgery in Korea by providing datasets on overall processes and outcome measures with quality indicators and risk adjustment factors. This approach will register characteristics of patients and monitor breast implants, complications, and surgical procedures to improve the outcomes of breast implant surgery in Korea. In addition, it can be used as a track-and-trace system with automated notifications to patients in the event of a product recall or other safety concerns related to a specific type of implant.
Topics: Adult; Australia; Austria; Breast Implantation; Breast Implants; Equipment and Supplies; Female; Humans; Postoperative Complications; Registries; Treatment Outcome; United States
PubMed: 32718052
DOI: 10.3390/medicina56080370 -
Dental Materials : Official Publication... Jun 2024Nanotechnology is constantly advancing in dental science, progressing several features aimed at improving dental implants. An alternative for surface treatment of dental... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
Nanotechnology is constantly advancing in dental science, progressing several features aimed at improving dental implants. An alternative for surface treatment of dental implants is electrochemical anodization, which may generate a nanotubular surface (TiO nanotubes) with antibacterial potential and osteoinductive features. This systematic review and meta-analysis aims to elucidate the possible antibacterial properties of the surface in question compared to the untreated titanium surface.
SOURCES
For that purpose, was performed a systematic search on the bases PubMed, Lilacs, Embase, Web Of Science, Cinahl, and Cochrane Central, as well as, manual searches and gray literature.
STUDY SELECTION
The searches resulted in 742 articles, of which 156 followed for full-text reading. Then, 37 were included in the systematic review and 8 were included in meta-analysis.
RESULTS
Fifteen studies revealed significant antibacterial protection using TiO nanotube surfaces, while 15 studies found no statistical difference between control and nanotextured surfaces. Meta-analysis of in vitro studies demonstrated relevant bacterial reduction only for studies investigating Staphylococcus aureus in a period of 6 h. Meta-analysis of in vivo studies revealed three times lower bacterial adhesion and proliferation on TiO nanotube surfaces.
CONCLUSIONS
TiO nanotube topography as a surface for dental implants in preclinical research has demonstrated a positive relationship with antibacterial properties, nevertheless, factors such as anodization protocols, bacteria strains, and mono-culture methods should be taken into consideration, consequently, further studies are necessary to promote clinical translatability.
Topics: Titanium; Nanotubes; Dental Implants; Surface Properties; Anti-Bacterial Agents; Bacterial Adhesion; Humans; Staphylococcus aureus
PubMed: 38714394
DOI: 10.1016/j.dental.2024.04.009 -
Neuroradiology Sep 2021Vagus nerve stimulation (VNS) is an effective adjunctive treatment for drug-resistant epilepsy (DRE) and difficult-to-treat depression (DTD). More than 125.000 patients... (Review)
Review
PURPOSE
Vagus nerve stimulation (VNS) is an effective adjunctive treatment for drug-resistant epilepsy (DRE) and difficult-to-treat depression (DTD). More than 125.000 patients have been implanted with VNS Therapy® System (LivaNova PLC) since initial approval. Patients with DRE often require magnetic resonance imaging (MRI) of the brain during the course of their disease. VNS Therapy System devices are labeled to allow MRI under certain conditions; however, there are no published comprehensive articles about the real-world experience using MRI in patients with implanted VNS devices.
METHODS
A systematic review in accordance with PRISMA statement was performed using PubMed database. Full-length articles reporting MRI (1.5 T or 3 T scanner) of patients with implanted VNS for DRE or DTD and published since 2000 were included. The primary endpoint was a positive outcome that was defined as a technically uneventful MRI scan performed in accordance with the VNS Therapy System manufacturer guidelines and completed according to the researchers' planned scanning protocol without harm to the patient.
RESULTS
Twenty-six articles were eligible with 25 articles referring to the VNS Therapy System, and 216 patients were included in the analysis. No serious adverse events or serious device-related adverse events were reported. MRI scan was prematurely terminated in one patient due to a panic attack.
CONCLUSION
This systematic review indicates that cranial MRI of patients with an implanted VNS Therapy System can be completed satisfactorily and is tolerable and safe using 1.5 T and 3 T MRI scanners when performed in adherence to the VNS manufacturer's guidelines.
Topics: Drug Resistant Epilepsy; Humans; Magnetic Resonance Imaging; Prostheses and Implants; Treatment Outcome; Vagus Nerve Stimulation
PubMed: 33846830
DOI: 10.1007/s00234-021-02705-y -
Contraception May 2024To summarize and update information regarding drug-drug interactions (DDIs) between antiretrovirals (ARVs) and hormonal contraceptives (HCs). (Review)
Review
OBJECTIVE
To summarize and update information regarding drug-drug interactions (DDIs) between antiretrovirals (ARVs) and hormonal contraceptives (HCs).
DESIGN
Systematic review METHODS: We searched seven databases for peer-reviewed publications from January 1, 2015, through December 31, 2023, including studies of women using ARVs and HCs concurrently with outcomes including therapeutic effectiveness or toxicity, pharmacokinetics (PK), or pharmacodynamics. We summarized findings and used checklists to assess evidence quality.
RESULTS
We included 49 articles, with clinical, ARV or HC PK outcomes reported by 39, 25, and 30 articles, respectively, with some articles reporting outcomes in two or more categories. Fifteen of 18 articles assessing DDIs between efavirenz and progestin implants, emergency contraception, or combined hormonal intravaginal rings found higher pregnancy rates, luteal progesterone levels suggesting ovulation, or reduced progestin PK values. Five studies documented that CYP2B6 single nucleotide polymorphisms exacerbated this DDI. One cohort detected doubled bone density loss with concomitant depot medroxyprogesterone acetate (DMPA) and tenofovir disoproxil fumarate (TDF)-containing ART use versus TDF alone. No other studies described DDIs impacting clinical outcomes. Few adverse events were attributed to ARV-HC use with none exceeding Grade 2. Evidence quality was generally moderate, with dis-similar treatment and control groups, identifying and controlling for confounding, and minimizing attrition bias in the study design being the most frequent limitations.
CONCLUSION
Most ARVs and HCs may be used safely and effectively together. TDF-DMPA DDIs warrant longer-term study on bone health and consideration of alternate combinations. For efavirenz-based ART, client counselling on relative risks, including both potential increase in pregnancy rate with concomitant efavirenz and implant use and lower pregnancy rates compared to other HCs even with concomitant efavirenz use, should continue to allow users comprehensive method choice.
PubMed: 38762199
DOI: 10.1016/j.contraception.2024.110490 -
BMC Medical Informatics and Decision... Nov 2022With the availability of several similar medical devices performing the same function, choosing one for reimbursement is not easy, especially if purchased for a large...
BACKGROUND
With the availability of several similar medical devices performing the same function, choosing one for reimbursement is not easy, especially if purchased for a large number of patients. The objective of this project was to create a multicriteria decision analysis (MCDA) tool, that captures and compares all implantable medical devices' attributes, to provide an objective method for choosing among the available options in Egypt.
METHOD
We conducted a systematic review and expert interviews, to identify the relevant criteria for inclusion in the tool. Subsequently, a workshop was conducted, that involved experts in procuring and tendering medical devices. Experts chose the criteria, ranked them, assigned weights and scoring functions for each criterion, and then created the draft tool. A pilot phase followed; then, another workshop was conducted to fine-tune the tool. We readjusted the tool based on experts' experience with the draft tool.
RESULTS
The final tool included eight criteria, arranged according to their weightage: technical characteristics (29.4%), country of origin (19.5%), use in reference countries (14.9%), supply reliability (11.7%), previous use in tenders (9.0%), instant replacement within product variety (6.9%), pharmacovigilance (4.6%), and refund or replacement (4.0%). Each medical device was assessed on these eight criteria to achieve a final score, that was compared to the alternative devices' scores. Price is not included in the MCDA tool, but it will be added in the financial evaluation phase.
CONCLUSION
Decisionmakers could use the MCDA tool, to make evidence-based and objective decisions for purchasing implantable devices, in the Egyptian public sector. Post price evaluation, the product with the best value will be chosen for reimbursement.
HIGHLIGHTS
We created an MCDA tool to help decision makers choose between alternative implantable medical devices in Egypt. The MCDA tool includes eight criteria, where price is evaluated as a separate step. "Technical characteristics" and "country of origin" criteria carried the highest weights, thus representing approximately 50% of the decision.
Topics: Humans; Decision Support Techniques; Egypt; Reproducibility of Results; Public Sector; Prostheses and Implants
PubMed: 36352382
DOI: 10.1186/s12911-022-02025-y -
Cancers Apr 2022This systematic review investigated circulating methylated tumor DNA in bronchial lavage fluid for diagnosing lung cancer. PROSPERO registration CRD42022309470. PubMed,... (Review)
Review
This systematic review investigated circulating methylated tumor DNA in bronchial lavage fluid for diagnosing lung cancer. PROSPERO registration CRD42022309470. PubMed, Embase, Medline, and Web of Science were searched on 9 March 2022. Studies of adults with lung cancer or undergoing diagnostic workup for suspected lung cancer were included if they used bronchial lavage fluid, analyzed methylated circulating tumor DNA, and reported the diagnostic properties. Sensitivity, specificity, and lung cancer prevalence were summarized in forest plots. Risk of bias was assessed using the QUADAS-2 tool. A total of 25 studies were included. All were case-control studies, most studies used cell pellet for analysis by quantitative PCR. Diagnostic sensitivity ranged from 0% for a single gene to 97% for a four-gene panel. Specificity ranged from 8% for a single gene to 100%. The studies employing a gene panel decreased the specificity, and no gene panel had a perfect specificity of 100%. In conclusion, methylated circulating tumor DNA can be detected in bronchial lavage, and by employing a gene panel the sensitivity can be increased to clinically relevant levels. The available evidence regarding applicability in routine clinical practice is limited. Prospective, randomized clinical trials are needed to determine the further usefulness of this biomarker.
PubMed: 35565384
DOI: 10.3390/cancers14092254 -
F1000Research 2023A systematic literature review was conducted to summarize the overall thermal performance of different gasified cooking stoves from the available literature. For this...
A systematic literature review was conducted to summarize the overall thermal performance of different gasified cooking stoves from the available literature. For this purpose, available studies from the last 14 years (2008 to 2022) were searched using different search strings. After screening, a total of 28 articles were selected for this literature review. Scopus, Google Scholar, and Web of Science databases were used as search strings by applying "Gasifier cooking stove" AND "producer gas cooking stove" AND "thermal performance" keywords. This review uncovers different gasified cooking stoves, cooking fuels, and fabrication materials besides overall thermal performances. The result shows that the overall thermal performance of different gasified cooking stoves was 5.88% to 91% depending on the design and burning fuels. The premixed producer gas burner with a swirl vane stove provided the highest overall thermal performance range, which was 84% to 91%, and the updraft gasified stove provided the lowest performance, which was 5.88% to 8.79%. The result also demonstrates that the wood pellets cooking fuel provided the highest thermal performance and corn straw briquette fuel provided the lowest for gasified cooking stoves. The overall thermal performance of wood pellets was 38.5% and corn straw briquette was 10.86%.
Topics: Air Pollution, Indoor; Cooking; Household Articles; Particulate Matter
PubMed: 37484517
DOI: 10.12688/f1000research.126890.2