The Journal of Thoracic and... Nov 2021Recent high-resolution computed tomography studies after transcatheter aortic valve insertion (TAVI) have reported a high prevalence of subclinical valve thrombosis... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Recent high-resolution computed tomography studies after transcatheter aortic valve insertion (TAVI) have reported a high prevalence of subclinical valve thrombosis (SCVT), potentially contributing to increased risk of late stroke. We aimed to investigate SCVT in patients after TAVI, with a focus on prevalence, predisposing factors, management, and potential sequelae.
METHODS
A comprehensive literature review of patients with SCVT after TAVI was carried out on all published studies in 3 major electronic databases from their inception until October 2019. Studies with sufficient data were included in a meta-analysis comparing the risk of stroke between patients with SCVT and those with normal valve function, as well as the protective effects of antiplatelet and anticoagulation on preventing SCVT.
RESULTS
From 3456 patients examined in a comprehensive review, 398 patients (11.5%) demonstrated evidence of SCVT during follow-up. Dual antiplatelet therapy was given in 45.5% of cases, single antiplatelet therapy in 19.8%, and oral anticoagulation in 28.5%. A meta-analysis demonstrated that rates of stroke were more than 3 times greater in patients with SCVT compared with those without (logistic odds, 1.10; 95% confidence interval, 0.63-1.57, P < .0001). Oral anticoagulation was superior to dual antiplatelet therapy or single antiplatelet therapy, preventing the formation of SCVT (logistic odds, -1.05, 95% confidence interval, -1.71 to -0.39, P < .0001).
CONCLUSIONS
Subclinical valve thrombosis is seen in 11.5% of patients after TAVI and is associated with increased risk of stroke. When oral anticoagulation is used postprocedurally, it is more effective than either dual or single-antiplatelet therapy in preventing subclinical valve thrombosis. These findings suggest that further studies are needed to define the optimal antithrombotic regimen to mitigate thrombotic and embolic sequelae after TAVI.
Topics: Aged; Aged, 80 and over; Anticoagulants; Aortic Valve; Asymptomatic Diseases; Female; Fibrinolytic Agents; Heart Valve Prosthesis; Humans; Male; Middle Aged; Platelet Aggregation Inhibitors; Risk Assessment; Risk Factors; Stroke; Thrombosis; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 32217021
DOI: 10.1016/j.jtcvs.2020.01.084 -
Infection Oct 2023Progress of interventional cardiology has boosted the use of newer cardiac devices. These devices are perceived to be less prone to infections compared to traditional... (Review)
Review
PURPOSE
Progress of interventional cardiology has boosted the use of newer cardiac devices. These devices are perceived to be less prone to infections compared to traditional surgical prostheses, but little data are currently available. In this systematic review (SR), we summarize current literature regarding the clinical characteristics, management, and outcomes of patients with MitraClip-related infective endocarditis (IE).
METHODS
We conducted a SR of PubMed, Google Scholar, Embase, and Scopus between January 2003 and March 2022. MitraClip-related IE was defined according to 2015 ESC criteria whereas MitraClip involvement as vegetation on the device or on the mitral valve. Risk of bias was assessed through standardized checklist and potential bias of underestimation cannot be excluded. Data regarding clinical presentation, echocardiography, management, and outcome were collected.
RESULTS
Twenty-six cases of MitraClip-related IE were retrieved. The median age of patients was 76 [61-83] years with a median EuroScore of 41%. Fever was present in 65.8% of patients followed by signs and symptoms of heart failure (42.3%). IE occurred early in 20 (76.9%) cases with a median time between MitraClip implantation and IE symptom onset of 5 [2-16] months. Staphylococcus aureus was the major causative microorganism (46%). Surgical mitral valve replacement was needed in 50% of patients. A conservative medical approach was considered in the remainder. The overall in-hospital mortality rate was 50% (surgical group: 38.4%; medical group: 58.3%; p = 0.433).
CONCLUSION
Our results suggest that MitraClip-related IE affects elderly, comorbid patients, is mostly due to Staphylococcus aureus, and has a poor prognosis irrespective of the therapeutic approach. Clinicians must be aware of the features of this new entity among cardiovascular infections.
Topics: Humans; Aged; Middle Aged; Aged, 80 and over; Heart Valve Prosthesis; Treatment Outcome; Endocarditis, Bacterial; Endocarditis; Mitral Valve; Mitral Valve Insufficiency
PubMed: 37386329
DOI: 10.1007/s15010-023-02067-y -
Procedural safety of transcatheter aortic valve replacement with Portico valve: a systematic review.International Journal of Surgery... Nov 2023The Portico transcatheter aortic heart valve is a self-expandable, fully resheathable bioprosthetic valve with a nitinol frame and porcine pericardial sealing cuff. It...
BACKGROUND
The Portico transcatheter aortic heart valve is a self-expandable, fully resheathable bioprosthetic valve with a nitinol frame and porcine pericardial sealing cuff. It has been used among symptomatic severe aortic stenosis (AS) who are at high or extreme surgical risk. However, till date very few studies has been reported with inconclusive evidence for its postprocedure safety outcomes.
OBJECTIVE
The authors aim to evaluate the safety of the Portico transcatheter aortic valve replacement system among patients with AS.
METHODOLOGY
The authors conducted a systematic literature search on PubMed, Embase, and Scopus from inception till 10th April 2023 by using predefined MESH terms using 'AND' and 'OR'. The following search terms were used: 'Aortic Stenosis' AND 'Transcatheter aortic valve replacement' OR 'Portico valve'. Finally, descriptive statistics were used to summarize the data in this paper. The mean and SD were adopted to describe continuous variables, whereas frequencies and percentages were used for dichotomous data.
RESULTS
A total of 7 studies with 2782 patients were included in the analysis. The mean age of patients was 82.3 years, and 54.63% were female. The most common comorbidity was hypertension (65.21%) and diabetes mellitus (26.45%). Among patients of AS with Portico valve implants, postprocedural outcomes including 30-day mortality (2.32%), cardiovascular mortality (2.37%), stroke (2.23%), myocardial infarction (0.94%), major bleeding (3.97%), major vascular complications (4.91%), acute kidney injury (1.37%), and permanent pacemaker implantations in 15.73% patients were reported. Overall, device success was observed in 95.82% of patients.
CONCLUSION
Transcatheter aortic valve replacement with the repositionable Portico valve, a new bioprosthesis, appears to have a low postprocedural mortality rate and other clinical outcomes in high-risk patients with severe AS.
Topics: Humans; Female; Animals; Swine; Aged, 80 and over; Male; Transcatheter Aortic Valve Replacement; Aortic Valve; Treatment Outcome; Postoperative Complications; Aortic Valve Stenosis; Heart Valve Prosthesis; Prosthesis Design
PubMed: 37581642
DOI: 10.1097/JS9.0000000000000645 -
Journal of Cardiovascular Imaging Apr 2023Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement...
BACKGROUND
Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning.
METHODS
We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI).
RESULTS
We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols.
CONCLUSIONS
This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.
PubMed: 37096677
DOI: 10.4250/jcvi.2022.0108 -
ESC Heart Failure Oct 2022Aortic stenosis (AS) and cardiac amyloidosis (CA) are typical diseases of the elderly. Up to 16% of older adults with severe AS referred to transcatheter aortic valve... (Meta-Analysis)
Meta-Analysis
AIMS
Aortic stenosis (AS) and cardiac amyloidosis (CA) are typical diseases of the elderly. Up to 16% of older adults with severe AS referred to transcatheter aortic valve replacement (TAVR) have a concomitant diagnosis of CA. CA-AS population suffers from reduced functional capacity and worse prognosis than AS patients. As the prognostic impact of TAVR in patients with CA-AS has been historically questioned and in light of recently published evidence, we aim to provide a comprehensive synthesis of the efficacy and safety of TAVR in CA-AS patients.
METHODS AND RESULTS
We performed a systematic review and meta-analysis of studies: (i) evaluating mortality with TAVR as compared with medical therapy in CA-AS patients and (ii) reporting complications and clinical outcomes of TAVR in CA-AS patients as compared with patients with AS alone. A total of seven observational studies were identified: four reported mortality with TAVR, and four reported complications and clinical outcomes after TAVR of patients with CA-AS compared with AS alone patients. In patients with CA-AS, the risk of mortality was lower with TAVR (n = 44) as compared with medical therapy (n = 36) [odds ratio (OR) 0.23, 95% confidence interval (CI) 0.07-0.73, I = 0%, P = 0.001, number needed to treat = 3]. The safety profile of TAVR seems to be similar in patients with CA-AS (n = 75) as compared with those with AS alone (n = 536), with comparable risks of stroke, vascular complications, life-threatening bleeding, acute kidney injury, and 30 day mortality, although CA-AS was associated with a trend towards an increased risk of permanent pacemaker implantation (OR 1.76, 95% CI 0.91-4.09, I = 0%, P = 0.085). CA is associated with a numerically higher rate of long-term mortality and rehospitalizations following TAVR in patients with CA-AS as compared with those with AS alone.
CONCLUSIONS
TAVR is an effective and safe procedure in CA-AS patients, with a substantial survival benefit as compared with medical therapy, and a safety profile comparable with patients with AS alone except for a trend towards higher risk of permanent pacemaker implantation.
Topics: Humans; Aged; Transcatheter Aortic Valve Replacement; Aortic Valve; Heart Valve Prosthesis Implantation; Risk Factors; Aortic Valve Stenosis; Amyloidosis
PubMed: 35770333
DOI: 10.1002/ehf2.13876 -
International Journal of Surgery... Aug 2023Whether there are differences among the new-generation transcatheter aortic valve implantation (TAVI) devices for patients with aortic stenosis remains unclear. The aim... (Meta-Analysis)
Meta-Analysis
Comparisons of different new-generation transcatheter aortic valve implantation devices for patients with severe aortic stenosis: a systematic review and network meta-analysis.
BACKGROUND
Whether there are differences among the new-generation transcatheter aortic valve implantation (TAVI) devices for patients with aortic stenosis remains unclear. The aim of the study was to compare the efficiency and safety of different new-generation TAVI devices for patients with aortic stenosis.
MATERIALS AND METHODS
A comprehensive search of PubMed, Embase and Web of Science from their inception to 1 February 2022. Randomized clinical trials and observational studies that compared two or more different TAVI devices were enroled. Pairwise meta-analysis and frequentist network meta-analysis were conducted to pool the outcome estimates of interest.
RESULTS
A total of 79 studies were finally included. According to the surface under the cumulative ranking, the top two ranked valves for lower rates of events were as follows: direct flow medical (DFM) (4.6%) and Lotus (48.8%) for lower rate of device success; Sapien 3 (16.8%) and DFM (19.7%) for lower mortality; DFM (8.6%) and Sapien 3 (25.5%) for lower rates of stroke; Evolut (27.6%) and DFM (35.8%) for lower rates of major and life-threatening bleeding; Portico (22.6%) and Sapien 3 (41.9%) for lower rates of acute kidney injury; Acurate (8.6%) and DFM (13.2%) for lower rates of permanent pacemaker implantation; Lotus (0.3%) and Sapien 3 (22.7%) for lower rates of paravalvular leak; Evolut (1.4%) and Portico (29.1%) for lower rates of mean aortic valve gradients.
CONCLUSIONS
The findings of the present study suggested that the device success rates were comparable among these new-generation valves except for DFM. After excluding DFM, Sapien 3 might be the best effective for decreased mortality and stroke; Lotus might be the best effective for decreased paravalvular leak; Evolut might be the best effective for decreased major and life-threatening bleeding and mean aortic valve gradients; Acurate and Portico might be the best effective for decreased permanent pacemaker implantation and acute kidney injury, respectively.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Network Meta-Analysis; Postoperative Complications; Treatment Outcome; Heart Valve Prosthesis; Prosthesis Design; Severity of Illness Index; Aortic Valve Stenosis; Stroke; Acute Kidney Injury
PubMed: 37161443
DOI: 10.1097/JS9.0000000000000456 -
Clinical Cardiology Jul 2022Either a mechanical or bioprosthetic valve is used in patients undergoing mitral valve replacement (MVR). However, the optimal mitral prosthesis remains controversial.... (Meta-Analysis)
Meta-Analysis Review
Either a mechanical or bioprosthetic valve is used in patients undergoing mitral valve replacement (MVR). However, the optimal mitral prosthesis remains controversial. The aim of this meta-analysis was thus to compare outcomes between mechanical mitral valve replacement (MVRm) and bioprosthetic mitral valve replacement (MVRb) for MVR patients. We searched Embase, PubMed, Web of Science, and Cochrane Library databases from January 1, 2000 to October 31, 2021 for studies that directly compared surgical outcomes of MVRm and MVRb. A total of 22 studies with 35 903 patients were included in the meta-analysis (n = 23 868 MVRm and n = 12 035 MVRb). The MVRm group displayed lower long-term all causes mortality (HR, 0.84; 95% confidence interval [CI]: 0.77-0.91; p < .0001; I² = 51%), and fewer mitral reoperation (hazard ratio [HR]: 0.34; 95% CI: 0.23-0.50; p < .00001; I² = 74%) than MVRb group. However, the MVRm group was associated with a greater risk of major bleeding events (HR: 1.21; 95% CI: 1.14-1.29; p < .00001; I² = 0%), stroke and systemic embolism (HR: 1.20; 95% CI: 1.10-1.32; p < .0001; I² = 0%) in matched or adjusted data. No significant difference was observed between MVRm and MVRb on operative mortality in matched/adjusted group (risk ratios: 0.83; 95% CI: 0.66-1.05; p = .12; I² = 0%). The results were consistent with patients aged under 70 years old. Patients who received a MVRm is associated with 16% lower risk of long-term mortality and 66% lower risk of mitral reoperation, but 20% greater risk of stroke or systemic embolism, 21% greater risk of major bleeding compared with MVRb in matched/adjusted studies group, which were consistent to patients younger than the age of 70 years who underwent MVR.
Topics: Aged; Biological Products; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Hemorrhage; Humans; Mitral Valve; Reoperation; Retrospective Studies; Stroke; Treatment Outcome
PubMed: 35665516
DOI: 10.1002/clc.23854 -
Journal of the American Heart... Mar 2021Background During the past decade, the use of transcatheter aortic valve replacement (TAVR) was extended beyond treatment-naïve patients and implemented for treatment... (Meta-Analysis)
Meta-Analysis
Background During the past decade, the use of transcatheter aortic valve replacement (TAVR) was extended beyond treatment-naïve patients and implemented for treatment of degenerated surgical bioprosthetic valves. Selection criteria for either valve-in-valve (viv) TAVR or redo surgical aortic valve replacement are not well established, and decision making on the operative approach still remains challenging for the interdisciplinary heart team. Methods and Results This review was intended to analyze all studies on viv-TAVR focusing on short- and mid-term stroke and mortality rates compared with redo surgical aortic valve replacement or native TAVR procedures. A structured literature search and review process led to 1667 potentially relevant studies on July 1, 2020. Finally, 23 studies fulfilled the inclusion criteria for qualitative analysis. All references were case series either with or without propensity score matching and registry analyses. Quantitative synthesis of data from 8509 patients revealed that viv-TAVR is associated with mean 30-day stroke and mortality rates of 2.2% and 4.2%, respectively. Pooled data analysis showed no significant differences in 30-day stroke rate, 30-day mortality, and 1-year mortality between viv-TAVR and comparator treatment (native TAVR [n=11 804 patients] or redo surgical aortic valve replacement [n=498 patients]). Conclusions This review is the first one comparing the risk for stroke and mortality rates in viv-TAVR procedures with native TAVR approach and contributes substantial data for the clinical routine. Moreover, this systematic review is the most comprehensive analysis on ischemic cerebrovascular events and early mortality in patients undergoing viv-TAVR. In this era with increasing numbers of bioprosthetic valves used in younger patients, viv-TAVR is a suitable option for the treatment of degenerated bioprostheses.
Topics: Aortic Valve; Aortic Valve Stenosis; Global Health; Humans; Incidence; Prosthesis Design; Registries; Risk Factors; Stroke; Survival Rate; Transcatheter Aortic Valve Replacement
PubMed: 33682426
DOI: 10.1161/JAHA.120.019512 -
Frontiers in Cardiovascular Medicine 2022We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid...
OBJECTIVE
We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized.
METHOD
Observational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline.
RESULTS
A total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75-0.97, = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV.
CONCLUSIONS
Despite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.
PubMed: 35369357
DOI: 10.3389/fcvm.2022.794850 -
The Permanente Journal Sep 2022IntroductionTakayasu's arteritis (TA) is an inflammatory condition that affects large vessels and frequently involves the aortic valve causing valve regurgitation.... (Review)
Review
IntroductionTakayasu's arteritis (TA) is an inflammatory condition that affects large vessels and frequently involves the aortic valve causing valve regurgitation. Surgical management is recommended for symptomatic severe aortic regurgitation (AR); however, the optimal surgical approach is yet unclear. This study aims to review surgical treatment options for AR in TA and determine which procedure has a lower chance of late postoperative events and/or mortality. MethodsAn electronic database search was performed within PubMed, EMBASE, Web of Science, and SCOPUS to identify articles from 1975 to 2016 focusing on surgical management of the AR in TA. ResultsTwenty seven studies encompassing a total of 194 cases (77% females) were included. Isolated aortic valve replacement (AVR) was performed in 105/194 cases (54%) (Group A), while combined aortic valve and root replacement (CAVRR) was performed in 87/194 (45%) (Group B). Prosthetic valve detachment was reported in 10/105 cases (9.5%) in group A and 1/87 cases (1.2%) in group B (p = 0.02). Dilation of the residual aorta was reported in 10/105 cases (9.5%) in group A and 1/87 cases (1.2%) in group B (p = 0.02). Any late (≥ 30 d) postoperative cardiac event was reported in 26/105 cases (24.8%) in group A, and in 7/87 cases (8.1%) in group B (p = 0.003). ConclusionsAlthough CAVRR is a more complex procedure, it might offer a better outcome in terms of late postoperative cardiac events compared to isolated AVR procedure. Future prospective studies are required to help determine the best surgical approach in such a population.
Topics: Aortic Valve; Aortic Valve Insufficiency; Female; Heart Valve Prosthesis Implantation; Humans; Male; Takayasu Arteritis
PubMed: 35939573
DOI: 10.7812/TPP/21.017