-
International Journal of Environmental... Jan 2023The aim of this review is to examine the links among the different factors that determine harmful or even deadly events in professional and semiprofessional intensive... (Review)
Review
The aim of this review is to examine the links among the different factors that determine harmful or even deadly events in professional and semiprofessional intensive Esports players. Cases of serious injuries or even death in young (<35 years old) male professional Esports players are reported every year. Fatalities and injuries in professional Esports players (PEGS) have only affected male players, and these events have mostly been concentrated in Asia. Studies in the literature have reported several causes and mechanisms of injuries. Links between injuries and previous comorbidities have emerged from the extant literature; obesity and/or metabolic disorders, seizures (associated with overstimulation of the eyes), heart malfunctions, high basal and abrupt increases in systolic blood pressure (SBP), prolonged stress, and poor posture have been associated with injuries. Several clinical signs have been identified and the question emerges whether or not self-regulation by Esports associations or public health authorities is necessary.
Topics: Male; Humans; Adult; Video Games; Blood Pressure; Asia
PubMed: 36767334
DOI: 10.3390/ijerph20031968 -
Hong Kong Physiotherapy Journal :... Dec 2020Spinal pain or misalignment is a very common disorder affecting a significant number of populations resulting in substantial disability and economic burden. Various...
BACKGROUND
Spinal pain or misalignment is a very common disorder affecting a significant number of populations resulting in substantial disability and economic burden. Various manual therapeutic techniques such as spinal manipulations and mobilizations can be used to treat and manage pain and movement dysfunctions such as spinal mal-alignments and associated complications. These manual therapeutic techniques can affect the cardiovascular parameters.
OBJECTIVE
The objective of this systematic review and meta-analysis is to assess the effect of spinal manipulation and mobilization on cardiovascular parameters.
METHODS
We conducted a systematic review and meta-analysis to assess the effects of spinal mobilization and manipulation on cardiovascular responses. Mean changes in Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP) and Heart Rate (HR) were primary outcome measures. RevMan 5.3 software was used for the meta-analyses. Quality of the included studies was assessed by PEDro Rating scale. Risk of bias was assessed by Cochrane collaboration tool of risk of bias.
RESULTS
Results of meta-analysis showed that there was statistically significant decrease in SBP ( , 95% , 0.08; ) with moderate heterogeneity ( , ) in experimental group as compared to control group. There was statistically non-significant decrease in DBP ( , 95% , 0.69; ) with high heterogeneity ( , ), Change HR was statistically non-significant ( , 95% , 3.11; ) with moderate heterogeneity ( , ). Exclusion of short duration studies in sensitivity analysis revealed a statistically significant change in DBP ( , 95% , ; ). However, the result was statistically non-significant for HR after sensitivity analysis.
CONCLUSION
Spinal manipulations and mobilizations may result in significant decrease of systolic as well as diastolic Blood Pressure.
PubMed: 33005072
DOI: 10.1142/S1013702520500122 -
Nutrients Oct 2023A systematic review was undertaken to investigate the involvement of hydration in heart rate (HR), HR variability (HRV) and diastolic (DBP) and systolic (SBP) blood... (Meta-Analysis)
Meta-Analysis Review
Influence of Fluid Ingestion on Heart Rate, Cardiac Autonomic Modulation and Blood Pressure in Response to Physical Exercise: A Systematic Review with Meta-Analysis and Meta-Regression.
A systematic review was undertaken to investigate the involvement of hydration in heart rate (HR), HR variability (HRV) and diastolic (DBP) and systolic (SBP) blood pressure in response to exercise. Data synthesis: The EMBASE, MEDLINE, Cochrane Library, CINAHL, LILACS and Web of Science databases were searched. In total, 977 studies were recognized, but only 36 were included after final screening (33 studies in meta-analysis). This study includes randomized controlled trials (RCTs) and non-RCTs with subjects > 18 years old. The hydration group consumed water or isotonic drinks, while the control group did not ingest liquids. For the hydration protocol (before, during and after exercise), the HR values during the exercise were lower compared to the controls (-6.20 bpm, 95%CI: -8.69; -3.71). In the subgroup analysis, "water ingested before and during exercise" showed lower increases in HR during exercise (-6.20, 95%CI: 11.70 to -0.71), as did "water was ingested only during exercise" (-6.12, 95%CI: -9.35 to -2.89). Water intake during exercise only revealed a trend of avoiding greater increases in HR during exercise (-4,60, 95%CI: -9.41 to 0.22), although these values were not significantly different ( = 0.06) from those of the control. "Isotonic intake during exercise" showed lower HRs than the control (-7.23 bpm, 95% CI: -11.68 to -2.79). The HRV values following the exercise were higher in the hydration protocol (SMD = 0.48, 95%CI: 0.30 to 0.67). The values of the SBP were higher than those of the controls (2.25 mmHg, 95%CI: 0.08 to 4.42). Conclusions: Hydration-attenuated exercise-induced increases in HR during exercise, improved autonomic recovery via the acceleration of cardiac vagal modulation in response to exercise and caused a modest increase in SBP values, but did not exert effects on DBP following exercise.
Topics: Humans; Adolescent; Blood Pressure; Heart Rate; Exercise; Water; Eating; Randomized Controlled Trials as Topic
PubMed: 37960187
DOI: 10.3390/nu15214534 -
Resuscitation Plus Sep 2024To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. (Review)
Review
AIM
To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth.
METHODS
A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence.
RESULTS
Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes.
LIMITATIONS
Certainty of evidence was low or very low for most comparisons.
CONCLUSION
If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.
PubMed: 38912532
DOI: 10.1016/j.resplu.2024.100668 -
Journal of Clinical Medicine Oct 2019Mindfulness Based Interventions (MBIs) have recently been increasingly used in clinical settings, and research regarding their effects on health has grown rapidly.... (Review)
Review
Mindfulness Based Interventions (MBIs) have recently been increasingly used in clinical settings, and research regarding their effects on health has grown rapidly. However, with regard to the physiological effects of mindfulness practices, studies have reported associations that vary in strength and direction. Therefore, in this systematic review and meta-analysis, we aimed to systematically identify, appraise, and summarize the existing data from randomized and non-randomized controlled trials that examine physiological effects of the standardized MBIs by focusing on pro-inflammatory cytokines and C-reactive protein, and commonly used heart rate variability parameters. The following electronic databases were searched: MEDLINE (via Ovid), PsychINFO (via Ovid), PubMed, Web of Science, EMBASE, CINAHL, ProQuest (Dissertations and Theses), and ClinicalTrails.gov. The systematic review identified 10 studies to be included in the meta-analysis, comprising in total 607 participants. The meta-analysis ended up with mixed and inconclusive results. This was assumedly due to the small number of the original studies and, in particular, to the lack of large, rigorously conducted RCTs. Therefore, the current meta-analysis highlights the necessity of larger, more rigorously conducted RCTs on physiological outcomes with standardized MBIs being compared to various forms of active controls, and with more long-term follow-ups.
PubMed: 31591316
DOI: 10.3390/jcm8101638 -
Clinical Autonomic Research : Official... Dec 2020Electronic cigarettes (ECs) are the fastest growing tobacco product in the USA, and ECs, like tobacco cigarettes (TCs), have effects on the cardiovascular autonomic... (Review)
Review
PURPOSE
Electronic cigarettes (ECs) are the fastest growing tobacco product in the USA, and ECs, like tobacco cigarettes (TCs), have effects on the cardiovascular autonomic nervous system, with clinical implications. The purpose of this review was to collect and synthesize available studies that have investigated the autonomic cardiovascular effects of EC use in humans. Special attention is paid to the acute and chronic effects of ECs, the relative contributions of the nicotine versus non-nicotine constituents in EC emissions and the relative effects of ECs compared to TCs.
METHODS
Using the methodology described in the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement, we conducted a literature search of the Ovid PubMed and Embase databases on 6 December 2019 using keywords in titles and abstracts of published literature. Acute (minutes to hours) and chronic (days or longer) changes in heart rate variability (HRV), heart rate (HR) and blood pressure (BP) were used as estimates of cardiovascular autonomic effects.
RESULTS
Nineteen studies were included in this systematic review, all of which used earlier generation EC devices. Acute EC vaping increased HR and BP less than acute TC smoking. Nicotine but not non-nicotine constituents in EC aerosol were responsible for the sympathoexcitatory effects. The results of chronic EC vaping studies were consistent with a chronic sympathoexcitatory effect as estimated by HRV, but this did not translate into chronic increases in HR or BP.
CONCLUSIONS
Electronic cigarettes are sympathoexcitatory. Cardiac sympathoexcitatory effects are less when vaping using the earlier generation ECs than when smoking TCs. Additional studies of the latest pod-like EC devices, which deliver nicotine similarly to a TC, are necessary.
Topics: Autonomic Agents; Cardiovascular System; Electronic Nicotine Delivery Systems; Humans; Nicotine; Vaping
PubMed: 32219640
DOI: 10.1007/s10286-020-00683-4 -
Cureus Dec 2023Photoplethysmography (PPG) is the wearable devices' most widely used technology for monitoring heart rate. The systematic review used the Preferred Reporting Items for... (Review)
Review
Photoplethysmography (PPG) is the wearable devices' most widely used technology for monitoring heart rate. The systematic review used the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) standards and guidelines. This systematic review seeks to establish the effects of wearable health devices on cardiac arrhythmias concerning their impact on the personalization of cardiac management, their refining effect on stroke prevention strategies, and their influence on research and preventive care of cardiac arrhythmias and their re-evaluation of the patient-physician relationship. The population, exposure, control, outcomes, and studies (PECOS) criteria were used in the systematic review. This review considered studies that covered the tests conducted on individuals who presented with cardiovascular diseases (CVD) and also healthy people. The intervention for studies included wearable health devices that could detect and diagnose cardiac arrhythmias. The study considered articles that reported on the personalization of cardiac management, stroke prevention strategies, influence in research and preventive care of cardiac arrhythmias, and the re-evaluation of the patient-physician relationship. Two independent researchers were used in the extraction of the data. In case of dispute, the issue was resolved using a third party. The study's quality analysis was conducted using AXIS. The management of atrial fibrillation (AF) lies heavily in the prevention of stroke. The accuracy being reported in the prediction of arrhythmias and the monitoring of heart rates makes wearable devices an efficient means to personalize health care. Personalization of health and treatment in preventing and managing arrhythmias becomes possible due to the portability of smart wearable devices. However, limitations may be observed due to the high costs incurred in their purchase and use. Using smart wearable devices for the detection of cardiac arrhythmias was very significant.
PubMed: 38249280
DOI: 10.7759/cureus.50952 -
The International Journal of Behavioral... Nov 2021Physical activity (PA) and sedentary behaviour (SB) of pre-school aged children are associated with important health and developmental outcomes. Accurate measurement of... (Review)
Review
A systematic review of the validity, reliability, and feasibility of measurement tools used to assess the physical activity and sedentary behaviour of pre-school aged children.
Physical activity (PA) and sedentary behaviour (SB) of pre-school aged children are associated with important health and developmental outcomes. Accurate measurement of these behaviours in young children is critical for research and practice in this area. The aim of this review was to examine the validity, reliability, and feasibility of measurement tools used to assess PA and SB of pre-school aged children.Searches of electronic databases, and manual searching, were conducted to identify articles that examined the measurement properties (validity, reliability or feasibility) of measurement tools used to examine PA and/or SB of pre-school aged children (3-7 years old). Following screening, data were extracted and risk of bias assessment completed on all included articles.A total of 69 articles, describing 75 individual studies were included. Studies assessed measurement tools for PA (n = 27), SB (n = 5), and both PA and SB (n = 43). Outcome measures of PA and SB differed between studies (e.g. moderate to vigorous activity, step count, posture allocation). Most studies examined the measurement properties of one measurement tool only (n = 65). Measurement tools examined included: calorimetry, direct observation, combined heart rate and accelerometry, heart rate monitors, accelerometers, pedometers, and proxy report (parent, carer or teacher reported) measures (questionnaires or diaries). Studies most frequently assessed the validity (criterion and convergent) (n = 65), face and content validity (n = 2), test-retest reliability (n = 10) and intra-instrument reliability (n = 1) of the measurement tools. Feasibility data was abstracted from 41 studies.Multiple measurement tools used to measure PA and SB in pre-school aged children showed some degree of validity, reliability and feasibility, but often for different purposes. Accelerometers, including the Actigraph (in particular GT3X versions), Actical, ActivPAL and Fitbit (Flex and Zip), and proxy reported measurement tools used in combination may be useful for a range of outcome measures, to measure intensity alongside contextual information.
Topics: Accelerometry; Child; Child, Preschool; Exercise; Feasibility Studies; Humans; Reproducibility of Results; Sedentary Behavior
PubMed: 34732219
DOI: 10.1186/s12966-021-01132-9 -
BMJ Open Sport & Exercise Medicine 2022To analyse the available evidence and identify gaps in current knowledge regarding physical activity volume and intensity and their effects on pregnancy outcomes in... (Review)
Review
OBJECTIVES
To analyse the available evidence and identify gaps in current knowledge regarding physical activity volume and intensity and their effects on pregnancy outcomes in female athletes.
DESIGN
Scoping review.
DATA SOURCES
A structured literature search of three electronic databases (Embase, PubMed and Web of Science) was conducted on 25 February 2022, and a rerun search was conducted on 8 September 2022.
ELIGIBILITY CRITERIA
Studies were eligible if they contained information on the relevant population (ie, elite or competitive amateur female athletes), intervention/exposure (ie, minimum of 10 hours of sport per week) and fetal and maternal outcomes. Eligible comparators included female recreational athletes and pregnant non-exercisers.
RISK OF BIAS
The risk of bias was evaluated with the National Institutes of Health (National Heart, Lung and Blood Institute) quality assessment tool.
RESULTS
The results revealed a discrepancy between the number of original research papers and the number of reviews and recommendations derived from them. The identified studies focused primarily on pregnant recreational athletes. Sixteen clinical studies met the inclusion criteria. No adverse effects on maternal or fetal outcomes were reported. Only during performance tests involving acute intensive exercise with the mother exercising at more than 90% of her maximal heart rate did some fetuses experience decelerations in heart rate.
SUMMARY/CONCLUSION
A lack of high-quality studies and direct evidence on pregnant elite and competitive amateur female athletes is evident. Further prospective observational cohort studies are needed using new monitoring methods (eg, non-invasive, wireless monitoring systems) aiming to gain a broader understanding of the stress tolerance of pregnant athletes and fetuses during exercise. Following that, interventional studies with stress tests in laboratory settings should be conducted. Therefore, technology plays a decisive role in gaining new knowledge and providing evidence-based recommendations on this topic.
PROSPERO REGISTRATION NUMBER
CRD42022309541.
PubMed: 36451657
DOI: 10.1136/bmjsem-2022-001395 -
Cureus Feb 2023Approximately 100 million people globally smoke cigarettes, making it a significant and quickly spreading global tobacco epidemic. Substance use disorders are frequently... (Review)
Review
Approximately 100 million people globally smoke cigarettes, making it a significant and quickly spreading global tobacco epidemic. Substance use disorders are frequently evaluated by non-randomized studies. Tobacco use and its impacts on the cardiovascular system were the subjects of a comprehensive search across five electronic databases: Cochrane, MEDLINE, Scopus, Embase, and PubMed. The findings demonstrated that waterpipe smokers in comparison to non-smokers have immediate elevations in heart rate and blood pressure, lower levels of high-density lipoprotein, higher levels of low-density lipoprotein, higher levels of triglycerides, higher levels of fasting blood glucose, and a higher heart rate. Users of waterpipes and cigarettes had similar average heart rates, blood pressure, and lipid levels, with the exception that waterpipe smokers had greater total cholesterol. Smoking a waterpipe has significant negative effects on the cardiovascular system comparable to cigarette smoking, and non-randomized studies proved to yield substantial evidence related to its cardiovascular effects. Such study designs can be used to evaluate substance use and its cardiovascular impact.
PubMed: 36915837
DOI: 10.7759/cureus.34802