JGH Open : An Open Access Journal of... Jun 2023Scirrhous gastric cancer (SGC) is diagnosed using endoscopy and/or biopsy; however, SGC diagnosis remains challenging owing to its special growth form and morphologic... (Review)
Review
Scirrhous gastric cancer (SGC) is diagnosed using endoscopy and/or biopsy; however, SGC diagnosis remains challenging owing to its special growth form and morphologic features. Hence, endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), which is minimally invasive and has a high proportion of diagnostic tissue, may be an alternative investigative modality for patients with suspected SGC. This systematic review and meta-analysis aimed to identify and evaluate the evidence for the efficacy and safety of EUS-FNA in patients with suspected SGC. We conducted a systematic review using the PubMed (MEDLINE) and Ichushi-Web (NPO Japan Medical Abstracts Society) databases and included all entries in which SGC was evaluated using EUS-FNA in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement from the databases' inception to October 10, 2022. The primary outcome was the proportion of SGC diagnosed using EUS-FNA. In addition, we analyzed the proportion of adverse events associated with EUS-FNA. The electronic search identified 1890 studies; overall, four studies met the selection criteria and reported data on EUS-FNA performed on 114 patients with suspected SGC. The overall diagnostic yield of EUS-FNA for SGC was 82.6% (95% confidence interval, 74.6-90.6%) and the statistical heterogeneity was 0% ( = 0%), indicating a low heterogeneity. Furthermore, the EUS-FNA diagnostic proportion for SGC lymph node metastasis was 75-100%, indicating a high diagnostic performance. The adverse event rate of EUS-FNA was 0%. EUS-FNA may be an alternative investigation mode for SGC patients with negative esophagogastroduodenoscopy-biopsy results.
PubMed: 37359117
DOI: 10.1002/jgh3.12929 -
Renal Failure 2023The needle size used in ultrasound-guided percutaneous renal biopsy significantly influences the efficacy and safety of the procedure. The aim of this study is to... (Meta-Analysis)
Meta-Analysis Review
The needle size used in ultrasound-guided percutaneous renal biopsy significantly influences the efficacy and safety of the procedure. The aim of this study is to perform a comparative analysis of 16-gauge and 18-gauge needles for ultrasound-guided percutaneous renal biopsy. This systematic review and meta-analysis included randomized controlled trials and observational studies that compared the outcomes of using 18-gauge and 16-gauge needles for ultrasound-guided percutaneous renal biopsy. The efficacy parameters included a mean number of glomeruli obtained and the number of passes, while the safety parameters focused on the rate of complications. We searched multiple databases, assessed the risk of bias, and conducted statistical analyses using appropriate models. Fifteen studies were included. Compared to the 18-gauge needle, the use of 16-gauge needle for the biopsy was associated with the significantly higher mean number of glomeruli obtained (pooled SMD 0.61, 95%CI: 0.32 to 0.89; < 0.001) and fewer required passes (pooled SMD -0.57, 95%CI: -0.97 to -0.18; = 0.004). No significant difference was observed in the individual safety parameters, including pain, hematuria, need for blood transfusion, major, and minor complications. However, the use of 16-gauge needle was associated with higher odds of total complications (pooled OR 1.57, 95%CI: 1.16 to 2.13; = 0.004). While the 16-gauge needle for ultrasound-guided percutaneous renal biopsy offers improved efficacy in terms of a higher mean number of glomeruli and fewer required passes, it is associated with higher total complications. A judicious needle size selection that would consider patient-specific factors and risk-benefit ratio, is crucial for optimizing patient outcomes.
Topics: Humans; Kidney; Kidney Glomerulus; Biopsy; Hematuria; Ultrasonography, Interventional; Observational Studies as Topic
PubMed: 37724553
DOI: 10.1080/0886022X.2023.2257806 -
World Journal of Gastroenterology Jul 2019Carcinoembryonic antigen (CEA) and cytology in pancreatic cystic fluid are suboptimal for evaluation of pancreatic cystic neoplasms. Genetic testing and microforceps... (Comparative Study)
Comparative Study Meta-Analysis
BACKGROUND
Carcinoembryonic antigen (CEA) and cytology in pancreatic cystic fluid are suboptimal for evaluation of pancreatic cystic neoplasms. Genetic testing and microforceps biopsy are promising tools for pre-operative diagnostic improvement but comparative performance of both methods is unknown.
AIM
To compare the accuracy of genetic testing and microforceps biopsy in pancreatic cysts referred for surgery.
METHODS
We performed a literature search in Medline, Scopus, and Web of Science for studies evaluating genetic testing of cystic fluid and microforceps biopsy of pancreatic cysts, with endoscopic ultrasound with fine-needle aspiration (EUS-FNA) prior to surgery and surgical pathology as reference standard for diagnosis. We evaluated the diagnostic accuracy for: 1- benign cysts; 2- mucinous low-risk cysts; 3- high-risk cysts, and the diagnostic yield and rate of correctly identified cysts with microforceps biopsy and molecular analysis. We also assessed publication bias, heterogeneity, and study quality.
RESULTS
Eight studies, including 1206 patients, of which 203 (17%) referred for surgery who met the inclusion criteria were analyzed in the systematic review, and seven studies were included in the meta-analysis. Genetic testing and microforceps biopsies were identical for diagnosis of benign cysts. Molecular analysis was superior for diagnosis of both low and high-risk mucinous cysts, with sensitivities of 0.89 (95%CI: 0.79-0.95) and 0.57 (95%CI: 0.42-0.71), specificities of 0.88 (95%CI: 0.75-0.95) and 0.88 (95%CI: 0.80-0.93) and AUC of 0.9555 and 0.92, respectively. The diagnostic yield was higher in microforceps biopsies than in genetic analysis (0.73 0.54, respectively) but the rates of correctly identified cysts were identical (0.73 with 95%CI: 0.62-0.82 0.71 with 95%CI: 0.49-0.86, respectively).
CONCLUSION
Genetic testing and microforceps biopsies are useful second tests, with identical results in benign pancreatic cysts. Genetic analysis performs better for low- and high-risk cysts but has lower diagnostic yield.
Topics: Cyst Fluid; Diagnosis, Differential; Endoscopic Ultrasound-Guided Fine Needle Aspiration; Genetic Testing; Humans; Pancreas; Pancreatic Cyst; Pancreatic Neoplasms; Preoperative Period; Sensitivity and Specificity
PubMed: 31341368
DOI: 10.3748/wjg.v25.i26.3450 -
Journal of Thoracic Disease Feb 2023Lung cancers with air lucency are poorly understood, often recognized only after substantial progression. (Review)
Review
BACKGROUND
Lung cancers with air lucency are poorly understood, often recognized only after substantial progression.
METHODS
From a systematic review (PubMed and EMBASE, 2000-2022, terms related to cystic, cavitary, bulla, pseudocavitary, bubble-like, date 10-30-2022) 49 studies were selected using broad inclusion criteria (case series of ≥10 cases up to trials and reviews). There was no source of funding. Primary evidence relevant to clinical management issues was assembled. Because data was available only from heterogeneous retrospective case series, meta-analysis and formal risk-of-bias assessment was omitted. A framework was developed to guide clinical management based on the available data.
RESULTS
Demographic, smoking and histologic differences suggest that cystic, cavitary and bullous lung cancers with air lucency may be distinct entities; insufficient data leaves it unclear whether this also applies to pseudocavitary (solid) or bubble-like (ground glass) cancers. Annual observation of irregular thin-walled cysts is warranted; a surgical diagnosis (and resection) is justified once a solid component appears because subsequent progression is often rapid with markedly worse outcomes. Bubble-like ground glass lesions should be managed similarly. Cavitary lesions must be distinguished from infection or vasculitis, but generally require needle or surgical biopsy. Pseudocavitary lesions are less well studied; positron emission tomography may be useful in this setting to differentiate scar from malignancy. Further research is needed because these conclusions are based on interpretation of retrospective case series.
CONCLUSIONS
The aggregate of available evidence suggests a framework for management of suspected lung cancers with air lucency. Greater awareness, earlier detection, and aggressive management once a solid component appears are needed. This review and framework should facilitate further research; questions include whether the suggested entities and proposed management are borne out and should involve clearly defined terms and outcomes related to progression and treatment. In summary, a conceptual understanding is emerging from interpretation of available data about a previously poorly understood topic; this should improve patient outcomes.
PubMed: 36910113
DOI: 10.21037/jtd-22-1199 -
Current Oncology (Toronto, Ont.) Mar 2023Landmark trials (Z0011 and AMAROS) have demonstrated that axillary lymph node dissection (ALND) can be safely omitted in patients with breast cancer and 1-2 positive... (Review)
Review
Landmark trials (Z0011 and AMAROS) have demonstrated that axillary lymph node dissection (ALND) can be safely omitted in patients with breast cancer and 1-2 positive sentinel nodes. Extrapolating from these and other cardinal studies such as NSABP B-04, guidelines state that patients with 1-2 needle biopsy-proven positive lymph nodes undergoing upfront surgery can have sentinel lymph node biopsy (SLNB) alone. The purpose of this study is to systematically review the literature to identify studies examining the direct application of SLNB in such patients. EMBASE and Ovid MEDLINE were searched from inception to 3 May 2022. Studies including patients with nodal involvement confirmed on pre-operative biopsy and undergoing SLNB were identified. Studies with neoadjuvant chemotherapy were excluded. Search resulted in 2518 records, of which 68 full-text studies were reviewed, ultimately yielding only 2 studies meeting inclusion criteria. Both studies used targeted axillary surgery (TAS) with pre-operative localization of the biopsy-proven positive node in addition to standard SLNB techniques. In a non-randomized single-center prospective study, Lee et al. report no regional recurrences in patients undergoing TAS or ALND, and no difference in distant recurrence or mortality at 5 years. In the prospective multicenter TAXIS trial by Webber et al., the median number of positive nodes retrieved with TAS in patients undergoing upfront surgery was 2 (1, 4 IQR). Within the subset of patients who underwent subsequent ALND, 61 (70.9%) had additional positive nodes, with 26 (30.2%) patients having ≥4 additional positive nodes. Our review demonstrates that there is limited direct evidence for SLNB alone in clinically node-positive patients undergoing upfront surgery. Available data suggest a high proportion of patients with residual disease in this setting. While the totality of the data, mostly indirect evidence, suggests SLNB alone may be safe, we call on clinicians and researchers to prospectively collect data on this patient population to better inform decision-making.
Topics: Humans; Female; Sentinel Lymph Node Biopsy; Breast Neoplasms; Prospective Studies; Lymph Node Excision; Axilla; Multicenter Studies as Topic
PubMed: 36975448
DOI: 10.3390/curroncol30030235 -
Neuro-oncology Practice Dec 2019Because less-invasive techniques can obviate the need for brain biopsy in the diagnosis of primary central nervous system lymphoma (PCNSL), it is common practice to wait... (Review)
Review
BACKGROUND
Because less-invasive techniques can obviate the need for brain biopsy in the diagnosis of primary central nervous system lymphoma (PCNSL), it is common practice to wait for a thorough initial work-up, which may delay treatment. We conducted a systematic review and reviewed our own series of patients to define the role of LP and early brain biopsy in the diagnosis of PCNSL.
METHODS
Our study was divided into 2 main sections: 1) systematic review assessing the sensitivity of cerebrospinal fluid (CSF) analysis on the diagnosis of PCNSL, and 2) a retrospective, single-center patient series assessing the diagnostic accuracy and safety of early biopsy in immunocompetent PCNSL patients treated at our institution from 2012 to 2018.
RESULTS
Our systematic review identified 1481 patients with PCNSL. A preoperative LP obviated surgery in 7.4% of cases. Brain biopsy was the preferred method of diagnosis in 95% of patients followed by CSF (3.1%). In our institutional series, brain biopsy was diagnostic in 92.3% of cases (24/26) with 2 cases that required a second procedure for diagnosis. Perioperative morbidity was noted in 7.6% of cases (n = 2) due to hemorrhages after stereotactic brain biopsy that improved at follow-up.
CONCLUSIONS
The diagnostic yield of CSF analyses for PCNSL in immunocompetent patients remains exceedingly low. Our institutional series demonstrates that early biopsy for PCNSL is safe and accurate, and may avert protracted work-ups. We conclude that performing an early brain biopsy in a suspected case of PCNSL is a valid, safe option to minimize diagnostic delay.
PubMed: 31832211
DOI: 10.1093/nop/npz015 -
Journal of Thoracic Disease Nov 2021Systemic arterial gas embolism (SAGE) is a rare yet serious and underrecognized complication of bronchoscopic procedures. A recent case of presumed SAGE after... (Review)
Review
BACKGROUND
Systemic arterial gas embolism (SAGE) is a rare yet serious and underrecognized complication of bronchoscopic procedures. A recent case of presumed SAGE after transbronchial needle aspiration prompted a systematic literature review of SAGE after biopsy procedures during flexible bronchoscopy.
METHODS
We performed a systematic database search for case reports and case series pertaining to SAGE after bronchoscopic lung biopsy; reports or series involving only bronchoscopic laser therapy or argon plasma coagulation (APC) were excluded. Patient data were extracted directly from published reports.
RESULTS
A total of 29 unique patient reports were assessed for patient demographics, specifics of the procedure, clinical manifestations, diagnostic findings, and clinical outcomes. Cases of SAGE occurred after multiple types of bronchoscopic biopsy and under both positive and negative pressure ventilation. The most common clinical findings were neurologic, followed by cardiac manifestations; temporal patterns included acute onset of cardiac or neurologic emergencies immediately after biopsy, or delayed awakening post-procedure. There was a high mortality rate among cases (28%), with residual neurologic deficits also common (24%).
DISCUSSION
SAGE is an underrecognized but severe adverse effect of bronchoscopic lung biopsy, which often presents with acute coronary or cerebral ischemia or delayed awakening from sedation. It is important for all physicians who perform bronchoscopic biopsies to be aware of the clinical manifestations and therapeutic management of SAGE in order to mitigate morbidity and mortality among patients undergoing these procedures.
PubMed: 34992823
DOI: 10.21037/jtd-21-717 -
Thyroid : Official Journal of the... Oct 2022Molecular tests for thyroid nodules with indeterminate fine needle aspiration results are increasingly used in clinical practice; however, true diagnostic summaries of... (Meta-Analysis)
Meta-Analysis Review
Molecular tests for thyroid nodules with indeterminate fine needle aspiration results are increasingly used in clinical practice; however, true diagnostic summaries of these tests are unknown. A systematic review and meta-analysis were completed to (1) evaluate the accuracy of commercially available molecular tests for malignancy in indeterminate thyroid nodules and (2) quantify biases and limitations in studies that validate those tests. PubMed, EMBASE, and Web of Science were systematically searched through July 2021. English language articles that reported original clinical validation attempts of molecular tests for indeterminate thyroid nodules were included if they reported counts of true-negative, true-positive, false-negative, and false-positive results. We performed screening and full-text review, followed by assessment of eight common biases and limitations, extraction of diagnostic and histopathological information, and meta-analysis of clinical validity using a bivariate linear mixed-effects model. Forty-nine studies were included. Meta-analysis of Afirma Gene expression classifiers (GEC; = 38 studies) revealed a sensitivity of 0.92 (confidence interval: 0.90-0.94), specificity of 0.26 (0.20-0.32), negative likelihood ratio (LR-) of 0.32 (0.23-0.44), positive LR+ of 1.24 (1.15-1.35), and area under the curve (AUC) of 0.83 (0.74-0.89). Afirma Genomic Sequencing Classifier (GSC; = 10) had a sensitivity of 0.94 (0.89-0.96), specificity of 0.38 (0.27-0.50), LR- of 0.18 (0.10-0.30), LR+ of 1.52 (1.28-1.87), and AUC of 0.91 (0.62-0.92). ThyroSeq v1 and v2 ( = 10) had a sensitivity of 0.86 (0.82-0.90), specificity of 0.74 (0.59-0.85), LR- of 0.19 (0.13-0.26), LR+ of 3.52 (2.08-5.92), and AUC of 0.86 (0.81-0.90). ThyroSeq v3 ( = 6) had a sensitivity of 0.92 (0.86-0.95), specificity of 0.41 (0.18-0.69), LR- of 0.24 (0.09-0.62), LR+ of 1.67 (1.09-2.98), and AUC of 0.90 (0.63-0.92). Fourteen percent of studies conducted a blinded histopathologic review of excised thyroid nodules, and 8% made the decision to go to surgery blind to molecular test results. Meta-analyses reveal a high diagnostic accuracy of molecular tests for thyroid nodule assessment of malignancy risk; however, these studies are subject to several limitations. Limitations and their potential clinical impacts must be addressed and, when feasible, adjusted for using valid statistical methodologies.
Topics: Humans; Thyroid Nodule; Pathology, Molecular; Biopsy, Fine-Needle; Molecular Diagnostic Techniques; Bias; Thyroid Neoplasms
PubMed: 35999710
DOI: 10.1089/thy.2022.0269 -
Endoscopy International Open May 2020Accurate diagnosis and risk stratification of pancreatic cysts (PCs) is challenging. The aim of this study was to perform a systematic review and meta-analysis to... (Review)
Review
Accurate diagnosis and risk stratification of pancreatic cysts (PCs) is challenging. The aim of this study was to perform a systematic review and meta-analysis to assess the feasibility, safety, and diagnostic yield of endoscopic ultrasound-guided through-the-needle biopsy (TTNB) versus fine-needle aspiration (FNA) in PCs. Comprehensive search of databases (PubMed, EMBASE, Cochrane, Web of Science) for relevant studies on TTNB of PCs (from inception to June 2019). The primary outcome was to compare the pooled diagnostic yield and concordance rate with surgical pathology of TTNB histology and FNA cytology of PCs. The secondary outcome was to estimate the safety profile of TTNB. Eight studies (426 patients) were included. The diagnostic yield was significantly higher with TTNB over FNA for a specific cyst type (OR: 9.4; 95 % CI: [5.7-15.4]; I = 48) or a mucinous cyst (MC) (OR: 3.9; 95 % CI: [2.0-7.4], I = 72 %). The concordance rate with surgical pathology was significantly higher with TTNB over FNA for a specific cyst type (OR: 13.5; 95 % CI: [3.5-52.3]; I = 48), for a MC (OR: 8.9; 95 % [CI: 1.9-40.8]; I = 29), and for MC histologic severity (OR: 10.4; 95 % CI: [2.9-36.9]; I = 0). The pooled sensitivity and specificity of TTNB for MCs were 90.1 % (95 % CI: [78.4-97.6]; I = 36.5 %) and 94 % (95 % CI: [81.5-99.7]; I = 0), respectively. The pooled adverse event rate was 7.0 % (95 % CI: [2.3-14.1]; I = 82.9). TTNB is safe, has a high sensitivity and specificity for MCs and may be superior to FNA cytology in risk-stratifying MCs and providing a specific cyst diagnosis.
PubMed: 32355885
DOI: 10.1055/a-1119-6543 -
Neuropathology and Applied Neurobiology Feb 2023Muscle biopsy techniques range from needle muscle biopsy (NMB) and conchotome biopsy to open surgical biopsy. It is unknown whether specific biopsy techniques offer...
AIMS
Muscle biopsy techniques range from needle muscle biopsy (NMB) and conchotome biopsy to open surgical biopsy. It is unknown whether specific biopsy techniques offer superior diagnostic yield or differ in procedural complication rates. Therefore, we aimed to compare the diagnostic utility of NMB, conchotome and open muscle biopsies in the assessment of neuromuscular disorders.
METHODS
A systematic literature review of the EMBASE and Medline (Ovid) databases was performed to identify original, full-length research articles that described the muscle biopsy technique used to diagnose neuromuscular disease in both adult and paediatric patient populations. Studies of any design, excluding case reports, were eligible for inclusion. Data pertaining to biopsy technique, biopsy yield and procedural complications were extracted.
RESULTS
Sixty-four studies reporting the yield of a specific muscle biopsy technique and, or procedural complications were identified. Open surgical biopsies provided a larger tissue sample than any type of percutaneous muscle biopsy. Where anaesthetic details were reported, general anaesthesia was required in 60% of studies that reported open surgical biopsies. Percutaneous biopsies were most commonly performed under local anaesthesia and despite the smaller tissue yield, moderate- to large-gauge needle and conchotome muscle biopsies had an equivalent diagnostic utility to that of open surgical muscle biopsy. All types of muscle biopsy procedures were well tolerated with few adverse events and no scarring complications were reported with percutaneous sampling.
CONCLUSIONS
When a histological diagnosis of myopathy is required, moderate- to large-gauge NMB and the conchotome technique appear to have an equivalent diagnostic yield to that of an open surgical biopsy.
Topics: Adult; Child; Humans; Biopsy; Neuromuscular Diseases; Biopsy, Needle; Muscular Diseases; Muscles; Retrospective Studies
PubMed: 36734037
DOI: 10.1111/nan.12888