Did you mean: dental clasps
-
BioMed Research International 2021The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures... (Review)
Review
The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures (RPDs) and how to optimize it. A literature survey was conducted for the English full-text articles, which used only FEA to estimate the stress developed in RPDs from Jan 2000 to May 2021. In RPDs, the retaining and supporting structures are subjected to dynamic loads during insertion and removal of the prosthesis as well as during function. The majority of stresses in free-end saddle (FES) RPDs are concentrated in the shoulder of the clasp, the horizontal curvature of the gingival approaching clasp, and the part of the major connector next to terminal abutments. Clasps fabricated from flexible materials were beneficial to eliminate the stress in the abutment, while rigid materials were preferred for major connectors to eliminate the displacement of the prosthesis. In implant-assisted RPD, the implant receive the majority of the load, thereby reducing the stress on the abutment and reducing the displacement of the prosthesis. The amount of stress in the implant decreases with zero or minimal angulation, using long and wide implants, and when the implants are placed in the first molar area.
Topics: Algorithms; Biomechanical Phenomena; Dental Abutments; Dental Implants; Denture Design; Denture, Partial, Removable; Finite Element Analysis; Humans; Stress, Mechanical
PubMed: 34485518
DOI: 10.1155/2021/5699962 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication...
PURPOSE
This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.
STUDY SELECTION
We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses. In this paper, the computer-aided design/computer-aided manufacturing (CAD/CAM) framework, artificial teeth, and denture base materials are reported.
RESULTS
A variety of materials, such as cobalt-chromium alloy, titanium, zirconia, and polyether ether ketone, are used for dental CAD/CAM frameworks. The mechanical strength of the metal materials used for the CAD/CAM framework was superior to that of the cast framework. However, the fitness and surface roughness of the framework and clasp fabricated using a selective laser melting (SLM) method were not superior to those obtained via cast fabrication. Most material properties and the surface roughness of poly methyl methacrylate (PMMA) discs used for digital RPDs were superior to those of heat-cured PMMA.
CONCLUSION
The use of a CAD/CAM framework and PMMA disc for digital RPDs offers numerous advantages over conventional RPDs. However, technical challenges regarding the accuracy and durability of adhesion between the framework and denture base remain to be solved. In digital fabrication, human technical factors influence the quality of the framework.
Topics: Computer-Aided Design; Denture Bases; Denture, Partial, Removable; Humans; Tooth, Artificial; Workflow
PubMed: 33504722
DOI: 10.2186/jpr.JPR_D_20_00117 -
Clinical and Experimental Dental... Feb 2022The purpose of this systematic review and meta-analysis was to compare implant-supported removable partial dentures (ISRPDs) with distal extension removable partial... (Meta-Analysis)
Meta-Analysis Review
Implant-supported removable partial dentures compared to conventional dentures: A systematic review and meta-analysis of quality of life, patient satisfaction, and biomechanical complications.
OBJECTIVES
The purpose of this systematic review and meta-analysis was to compare implant-supported removable partial dentures (ISRPDs) with distal extension removable partial dentures (DERPDs) in terms of patient-reported outcome measures (PROMs: patients' quality of life and satisfaction) and to determine mechanical and biological complications associated with ISRPDs.
MATERIAL AND METHODS
An electronic search was performed on four databases to identify studies treating Kennedy class I or II edentulous patients and which compared ISRPDs with DERPDs in terms of PROMS and studies, which evaluated mechanical and biological complications associated ISRPDs. Two authors independently extracted data on quality of life, patient satisfaction, and biomechanical complications from these studies. The risk of bias was assessed for each study, and for PROMs, the authors performed a meta-analysis by using a random-effects model.
RESULTS
Thirteen articles were included based on the selection criteria. The difference in mean scores for quality of life (30.5 ± 1.8; 95% confidence interval [CI], 24.9-36.1) and patient satisfaction (-20.8 ± 0.2; 95% CI, -23.7 to -17.8) between treatments with conventional and implant-supported removable dentures was statistically significant (p < .05). Implant-supported removable dentures improved patients' overall quality of life and satisfaction. Some mechanical and biological complications, such as clasp adjustment, abutment or implant loosening, marginal bone resorption, and peri-implant mucositis, were noted in ISRPDs during patient follow-up. Studies assessing PROMs were very heterogeneous (I = 65%, p = .85; I = 75%, p = .88).
CONCLUSIONS
ISRPDs significantly improved quality of life and patient satisfaction. Some mechanical and biological complications have been associated with ISRPDs treatment, requiring regular monitoring of patients to avoid the occurrence of these complications.
Topics: Dental Implants; Dental Prosthesis, Implant-Supported; Denture, Partial, Removable; Humans; Patient Satisfaction; Quality of Life
PubMed: 35014207
DOI: 10.1002/cre2.521 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case...
PURPOSE
This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.
STUDY SELECTION
We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis. We report evidence from clinical papers and case reports, digital impression-taking methods, and maxillomandibular relationship (MMR) records.
RESULTS
A case report electronically published in 2019 introduced a clasp-retained RPD fabricated via a full-digital workflow without a gypsum definitive cast. Computer-aided design and computer-aided manufacturing of double-crown-retained RPDs with nonmetal materials were described in some case reports. Intraoral scanners were used to obtain digital impressions and MMR records in the fabrication of digital RPDs, which have potential advantages for reducing the number of clinical appointments and simplifying laboratory procedures. Evidence from clinical trials is scarce; a randomized controlled trial reported higher patient satisfaction with digital clasp-retained RPDs than with conventional RPDs.
CONCLUSIONS
Full-digital RPDs can be fabricated without a gypsum definitive cast. However, the indication for full-digital RPDs is limited to cases with Kennedy Class III/IV partially edentulous arches with several missing teeth. Challenges in digital impression-taking and MMR recording remain to be solved to extend these indications. More evidence from clinical trials is required to evaluate the efficacy and usefulness of digital RPDs.
Topics: Computer-Aided Design; Denture, Partial, Removable; Humans; Mouth, Edentulous; Randomized Controlled Trials as Topic
PubMed: 33504721
DOI: 10.2186/jpr.JPR_D_20_00116 -
Journal of Indian Prosthodontic Society 2020The aim was to discuss the indications, contraindications, advantages, and disadvantages of Nonmetal clasp dentures (NMCDs), as well as the most relevant properties of... (Review)
Review
The aim was to discuss the indications, contraindications, advantages, and disadvantages of Nonmetal clasp dentures (NMCDs), as well as the most relevant properties of its constituent materials. A search was conducted using the keywords: "nonmetal clasp dentures," "thermoplastic resin," "flexible resin removable partial denture," "polyamide," and "nylon" in databases PubMed/Medline, Lilacs, SciELO, and textbooks between 1955 and 2020. Theses and texts without reliable sources of publication were excluded. Once the analysis instruments were determined, the data were analyzed and discussed. NMCDs present high flexibility, easy adaptation to the abutments, color compatibility and biocompatibility with the oral mucosa, and absence of visible metal clasps. However, they need laboratory relining, grinding, and polishing, do not have criteria for its planning, become rougher and stained over time, and are able to traumatize supporting tissues. The association with metal components seems to be an alternative to increase the success of NMCDs by combining esthetics and biomechanical principles of conventional removable partial dentures. The lack of long-term clinical studies makes the professionals to rely solely on previous experiences or on the manufacturers' recommendations. It suggested that NMCDs must be indicated with caution when not used temporarily.
PubMed: 33223697
DOI: 10.4103/jips.jips_459_19 -
The Journal of Prosthetic Dentistry Nov 2023A 55-year-old man wearing maxillary and mandibular clasp-retained removable partial dentures (RPDs) sought improvement in retention, support, mastication efficiency, and...
A 55-year-old man wearing maxillary and mandibular clasp-retained removable partial dentures (RPDs) sought improvement in retention, support, mastication efficiency, and esthetics. Three prosthodontic treatment options were provided to the patient, who selected maxillary and mandibular conical crown-retained removable partial dentures (CCRPDs) without strategic implants. Oral health-related quality of life (OHRQoL) and satisfaction of the patient were evaluated before treatment and 2 weeks and 1 year after inserting the CCRPDs. The patient reported better retention, support, stability, mastication efficiency, esthetics, and an improved OHRQoL after CCRPD placement than before treatment. These improvements were maintained after 1 year.
PubMed: 37953210
DOI: 10.1016/j.prosdent.2023.09.041 -
BioMed Research International 2021This systematic review is aimed at investigating the biomechanical stress that develops in the maxillofacial prostheses (MFP) and supporting structures and methods to...
AIM
This systematic review is aimed at investigating the biomechanical stress that develops in the maxillofacial prostheses (MFP) and supporting structures and methods to optimize it. . A literature survey was conducted for full-text English articles which used FEA to examine the stress developed in conventional and implant-assisted MFPs from January 2010 to December 2020.
RESULTS
87 articles were screened to get an update on the desired information. 74 were excluded based on a complete screening, and finally, 13 articles were recruited for complete reviewing. . The MFP is subjected to stress, which is reflected in the form of compressive and tensile strengths. The stress is mainly concentrated the resection line and around the apices of roots of teeth next to the defect. Diversity of designs and techniques were introduced to optimize the stress distribution, such as modification of the clasp design, using materials with different mechanical properties for dentures base and retainer, use of dental (DI) and/or zygomatic implants (ZI), and free flap reconstruction before prosthetic rehabilitation.
CONCLUSION
Using ZI in the defective side of the dentulous maxillary defect and defective and nondefective side of the edentulous maxillary defect was found more advantageous, in terms of compression and tensile stress and retention, when compared with DI and free flap reconstruction.
Topics: Animals; Biomechanical Phenomena; Finite Element Analysis; Humans; Imaging, Three-Dimensional; Maxilla; Maxillofacial Prosthesis; Stress, Mechanical
PubMed: 34447852
DOI: 10.1155/2021/6419774 -
Polymers Feb 2023Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability,...
BACKGROUND
Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt-chromium (Co-Cr) clasp.
METHODS
Forty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software.
RESULTS
The results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation ( ≤ 0.014) than Co-Cr.
CONCLUSION
The deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework.
PubMed: 36850239
DOI: 10.3390/polym15040956 -
Polymers Oct 2022The high-performance thermoplastic polyetheretherketone (PEEK) has excellent mechanical properties, biocompatibility, chemical stability, and radiolucency. The present... (Review)
Review
The high-performance thermoplastic polyetheretherketone (PEEK) has excellent mechanical properties, biocompatibility, chemical stability, and radiolucency. The present article comprehensively reviews various applications of PEEK in removable dental prostheses, including in removable partial dentures (RPDs) (frameworks and clasps), double-crown RPDs, and obturators. The clinical performance of PEEK in removable dental prostheses is shown to be satisfactory and promising based on the short-term clinical evidence and technical complications are scarce. Moreover, the accuracy of RPDs is a vital factor for their long-term success rate. PEEK in removable dental prostheses is fabricated using the conventional lost-wax technique and CAD/CAM milling, which produces a good fit. Furthermore, fused deposition modeling is considered to be one of the most practical additive techniques. PEEK in removable prostheses produced by this technique exhibits good results in terms of the framework fit. However, in light of the paucity of evidence regarding other additive techniques, these manufacturers cannot yet be endorsed. Surface roughness, bacterial retention, color stability, and wear resistance should also be considered when attempting to increase the survival rates of PEEK removable prostheses. In addition, pastes represent an effective method for PEEK polishing to obtain a reduced surface roughness, which facilitates lower bacterial retention. As compared to other composite materials, PEEK is less likely to become discolored or deteriorate due to wear abrasion.
PubMed: 36365609
DOI: 10.3390/polym14214615 -
Clinical and Experimental Dental... Dec 2022To investigate the fatigue behavior of cast and laser-sintered cobalt-chromium (CoCr) and polyetheretherketone (PEEK) material for a removable partial denture (RPD)...
OBJECTIVE
To investigate the fatigue behavior of cast and laser-sintered cobalt-chromium (CoCr) and polyetheretherketone (PEEK) material for a removable partial denture (RPD) clasps.
METHODS
Dumbbell-shaped specimens were digitally designed with the center part of the dumbbell being a half-round shape at the cross-sectional dimension of 1.25 mm to simulate a typical clasp design and dimensions. A fatigue machine with an offset axis rotation system simulated a typical undercut depth of 0.25, 0.50, and 0.75 mm. Each group was subjected to 30,000 fatigue cycles (simulating 21 years) or till specimen failure. Before testing, the stress value at each undercut depth for each specimen was established in a universal testing machine and SN curves were plotted for each group. Data were statistically analyzed using Kruskal-Wallis and post hoc tests. The fractured surfaces were analyzed using SEM.
RESULTS
The average fatigue cycles with 0.25, 0.50, and 0.75 mm undercuts were 27,155 ± 6277, 9298 ± 4033, 5642 ± 8785 for cast CoCr and 26,765 ± 6150, 11,318 ± 7931, 2861 ± 4803, for laser-sintered CoCr, respectively. Apart from three specimens, the PEEK groups did not fail during the simulation period. Clasps with 0.25 mm deflection showed significantly higher fatigue resistance than other groups (p < .001). There was no significant difference in fatigue behavior between the cast and laser-sintered CoCr. Microporosities at the fractured site along with irregular crack propagation were observed for cast and laser-sintered CoCr specimens. Fatigue-induced broken polymer crosslinking chains were observed in PEEK specimens.
CONCLUSION
PEEK material exhibited the highest fatigue resistance and significantly lower deflection resistance. Cast and laser-sintered CoCr showed similar fatigue resistance and behavior.
Topics: Denture, Partial, Removable; Cobalt; Chromium; Chromium Alloys; Cross-Sectional Studies; Dental Stress Analysis; Materials Testing; Ketones; Lasers; Polyethylene Glycols
PubMed: 35938907
DOI: 10.1002/cre2.645