International Journal of Implant... Oct 2020The objective of the study was to evaluate the relation between occlusal loading and peri-implant crevicular fluid cytokine expression in patients with implant-supported...
OBJECTIVE
The objective of the study was to evaluate the relation between occlusal loading and peri-implant crevicular fluid cytokine expression in patients with implant-supported complete fixed prostheses in both arches.
MATERIAL AND METHODS
A prospective longitudinal clinical study was performed at a university clinic. Fifteen patients were selected and 11 were included. All patients had bimaxillary implant-supported complete fixed ceramo-metallic prostheses loaded at least 12 months before the beginning of the study. Allocation was established for each patient using a computerized occlusal analysis system. The test implant was the maxillary implant closest to the point of highest occlusal loading. The maxillary implant with least loading was the control implant. Occlusal adjustment was performed using a round diamond burr. This occlusal distribution was verified with the occlusal analysis system. Expression of cytokines from peri-implant crevicular fluid (TNF-α, IL-10, IL-6, IL-1β, IL-8) were recorded and analyzed in both test and control implants before (baseline: T0) and 2 (T1) and 12 months (T2) after occlusal adjustment. The Brunner-Langer non-parametric test was performed.
RESULTS
At T0, the expression of IL-10 was significantly higher in the test group implants (p = 0.018). Between T0 and T1, the expression of all the cytokines decreased in the implants of both groups with statistically significant differences, except for TNF (p = 0.271). When comparing both groups at T1, there was no statistically significant difference in any of the analyzed cytokines. At T2, TNF-α suffered when compared with baseline, a statistical decrease in both study and control implants (p < 0,001). At T2, there were no statistically significant differences between groups in any of the cytokines analyzed.
CONCLUSIONS
Implants with higher occlusal load presented higher expression of IL-10 in peri-implant crevicular fluid. Occlusal adjustment produced a decrease in the expression of all the analyzed cytokines, both in test and control implants.
PubMed: 33111201
DOI: 10.1186/s40729-020-00262-2 -
International Journal of Environmental... Sep 2022This study assessed the clinical variables influencing the success of three-unit implant-supported fixed dental prostheses (ISFDPs) fabricated using either fully digital...
This study assessed the clinical variables influencing the success of three-unit implant-supported fixed dental prostheses (ISFDPs) fabricated using either fully digital or conventional workflows. The clinical trial evaluated 10 patients requiring three-unit ISFDPs in the posterior mandible. Maxillomandibular relation records, and digital and conventional impressions were obtained from each patient using an intraoral scanner (IoS) and polyvinylsiloxane (PVS), and the frameworks were fabricated using zirconia and cobalt-chromium, respectively. A 2 µm accuracy scanner scanned the conventional master casts and standard reference models. The stereolithography (STL) files of the digital and conventional impressions were superimposed on the standard model file, and the accuracy was calculated with the best-fit algorithm. The framework adaptation and passivity were assessed using the one-screw and screw resistance tests. The time required for occlusal adjustment of both types of reconstructions, including the duration of the whole treatment, was recorded. The aesthetic appearance of ISFDPs was rated by each patient and clinician using a self-administered visual analogue scale questionnaire and the FDI World Dental Federation aesthetic parameters, respectively. The sample size was based on the power calculation, and alpha was set at 0.05 for the statistical analyses. The impression accuracy, framework adaptation and passivity, and reconstructions aesthetics did not significantly differ between the digital and conventional approaches. The total fabrication time was significantly shorter using the digital workflow. Within the limitations of this clinical study, the fully digital workflow can be used for the fabrication of ISFDPs with a clinical outcome comparable to that of the conventional workflow.
Topics: Chromium; Cobalt; Computer-Aided Design; Cross-Over Studies; Humans; Prospective Studies; Workflow
PubMed: 36141729
DOI: 10.3390/ijerph191811456 -
Journal of Dental Research Jul 2021The aims of this study were to 1) determine if continuous eruption occurs in the maxillary teeth, 2) assess the magnitude of the continuous eruption, and 3) evaluate the...
The aims of this study were to 1) determine if continuous eruption occurs in the maxillary teeth, 2) assess the magnitude of the continuous eruption, and 3) evaluate the effects of continuous eruption on the different periodontal parameters by using data from the population-based cohort of the Study of Health in Pomerania (SHIP). The jaw casts of 140 participants from the baseline (SHIP-0) and 16-y follow-up (SHIP-3) were digitized as 3-dimensional models. Robust reference points were set to match the tooth eruption stage at SHIP-0 and SHIP-3. Reference points were set on the occlusal surface of the contralateral premolar and molar teeth, the palatal fossa of an incisor, and the rugae of the hard palate. Reference points were combined to represent 3 virtual occlusal planes. Continuous eruption was measured as the mean height difference between the 3 planes and rugae fix points at SHIP-0 and SHIP-3. Probing depth, clinical attachment levels, gingiva above the cementoenamel junction (gingival height), and number of missing teeth were clinically assessed in the maxilla. Changes in periodontal variables were regressed onto changes in continuous eruption after adjustment for age, sex, number of filled teeth, and education or tooth wear. Continuous tooth eruption >1 mm over the 16 y was found in 4 of 140 adults and averaged to 0.33 mm, equaling 0.021 mm/y. In the total sample, an increase in continuous eruption was significantly associated with decreases in mean gingival height ( = -0.34; 95% CI, -0.65 to -0.03). In a subsample of participants without tooth loss, continuous eruption was negatively associated with PD. This study confirmed that continuous eruption is clearly detectable and may contribute to lower gingival heights in the maxilla.
Topics: Adult; Dental Occlusion; Follow-Up Studies; Humans; Incisor; Maxilla; Tooth Eruption
PubMed: 33655796
DOI: 10.1177/0022034521999363 -
Case Reports in Dentistry 2022In this study, we have introduced a case in which the effective blood oxygenation level-dependent signal on functional magnetic resonance imaging (fMRI) was altered by...
OBJECTIVE
In this study, we have introduced a case in which the effective blood oxygenation level-dependent signal on functional magnetic resonance imaging (fMRI) was altered by the improvement of periodontal tissue and occlusal function in a patient with periodontitis Stage II Grade B. . A 61-year-old female patient requiring periodontal treatment was diagnosed as having periodontitis Stage II Grade B via clinical and radiographic examinations. Her past medical history included type 2 diabetes, hypertension, and hyperlipidemia. Following the patient's informed written consent, the periodontal initial treatment provided to the patient included tooth brushing instruction and scaling and root planing; however, occlusal adjustment was not performed at this stage. Occlusal force and fMRI results were also evaluated at the initial and reevaluation examinations.
RESULTS
After the periodontal initial treatment had been performed, it was noted that the patient's periodontal tissue and occlusal force had improved. It was also evident from fMRI that cerebral blood flow had been activated in the insula, primary motor cortex, and premotor cortex.
CONCLUSION
This result suggested that the periodontal ligament had recovered and the periodontal ligament neuron had been further subjected to clenching in the insula so that the muscle spindle sensation impacted the motor cortex.
PubMed: 35527723
DOI: 10.1155/2022/5383893 -
The Saudi Dental Journal Nov 2021Occlusal appliances can distribute aggressive loads which are generated by bruxism and can reduce their frequency. The facebow record, when used in the construction of...
BACKGROUND
Occlusal appliances can distribute aggressive loads which are generated by bruxism and can reduce their frequency. The facebow record, when used in the construction of occlusal appliances, helps in minimizing occlusal discrepancies. This study aimed to compare the effect of CAD/CAM stabilization occlusal splint made with and without facebow for management of bruxer patients.
METHOD
24 Patients who were diagnosed as bruxers were randomly assigned into two equal groups and obtained maxillary CAD/CAM occlusal stabilizing splint recorded with centric relation either with or without using a facebow. The patient satisfaction using the visual analog scale (VAS) was recorded at baseline, one month and three months' follow-up periods. The adjustment time of both splints, from the start of splint delivery until becoming well-fitted and occlusally adjusted, was calculated using a stopwatch.
RESULTS
The CAD/CAM occlusal splints with or without the use of facebow improved the patient's satisfaction with no statistically significant difference between both groups at baseline, one month and three months with p values of 0.73, 0.24 and 0.45 respectively. The comparison between the two modalities regarding the adjustment time showed no statistically significant difference between both groups (P = 0.06).
CONCLUSION
According to the results of this study; no difference was detected in patient satisfaction and the time required for adjustment of CAD/CAM occlus.
PubMed: 34803311
DOI: 10.1016/j.sdentj.2020.07.002 -
Revista Cientifica Odontologica... 2022The aim of optimal dentistry is to stabilise the stomatognathic system (teeth, periodontium, muscles and temporomandibular joint). All of these must work in harmony, as...
The aim of optimal dentistry is to stabilise the stomatognathic system (teeth, periodontium, muscles and temporomandibular joint). All of these must work in harmony, as together they provide optimal care from diagnosis through planning to treatment. However, many clinicians currently give little importance to the identification of premature contacts and/or interferences prior to any dental treatment, which should be taken into account to provide improved stability in mandibular closure, correct anterior and canine guidance in mandibular movements.This clinical case describes the treatment of a patient with a diagnosis of functional occlusal disorder due to premature contact, whose treatment consisted of an occlusal adjustment by selective wear, following the technique described by the author Klineberg, with the aim of preserving the dental structure as much as possible while maintaining control during the occlusal adjustment and returning the greatest number of symmetrical and pointed contacts.
PubMed: 38389550
DOI: 10.21142/2523-2754-1003-2022-122 -
Materials (Basel, Switzerland) May 2021CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps.
BACKGROUND
CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps.
PURPOSE
The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems.
MATERIALS AND METHODS
Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A-D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferroni adjustment was performed. The global level of significance was set at 5%.
RESULTS
The mean gap size ranged from 84 to 132 µm (SD 43-71 µm). The CAD/CAM systems showed significant variance ( < 0.001), and system A (VHF) showed the smallest gaps. The smallest gaps for each system were in the molar part and in the marginal region of the frameworks ( < 0.001).
CONCLUSIONS
The CAD/CAM systems showed significantly different gap sizes, particularly between premolars and molars and among the marginal, axial and occlusal regions. All of the systems are suitable for clinical application.
PubMed: 34069551
DOI: 10.3390/ma14102663 -
BMC Oral Health Mar 2024Overerupted maxillary molars is common in adults, which can lead to insufficient intermaxillary vertical space ,great difficulty in prosthetic reconstruction ,and cause...
BACKGROUND
Overerupted maxillary molars is common in adults, which can lead to insufficient intermaxillary vertical space ,great difficulty in prosthetic reconstruction ,and cause occlusal interference in movements.To reconstruct occlusal function, it is necessary to prepare enough space for prostheses. The aim of the present study was to evaluate the effect of space-adjustment occlusal splint on overerupted maxillary molars by clinical and electromyographic signals analysis.
METHODS
Eighteen patients with overerupted maxillary molars were selected to wear space-adjustment occlusal splint suppressing overerupted maxillary molars for three months. Satisfaction was assessed by 5-point Likert; intermaxillary vertical space and the teeth transportation distance were measured in models; clinical periodontal status were evaluated by periodontal probing depth (PPT) and bleeding index (BI); electromyographic recordings of the masseter and anterior temporal muscles were monitored by Cranio-Mandibular K7 Evaluation System.
RESULTS
All the patients were satisfied with the treatment effect (Likert scale ≧ 4). The intermaxillary space in edentulous areas after treatment showed statistically significant increasing when compared with those before treatment. PPT and BI showed no significant difference. No statistically significant differences were found in electromyographic activity of anterior temporal muscles, while a reduction of muscle activity in masseter in the contralateral side were detected in post-treatment evaluations compared with pre-treatment at mandibular rest position.
CONCLUSIONS
Space-adjustment occlusal splint is an efficient treatment option on overerupted maxillary molars by intruding the maxillary molar to obtain adequate intermaxillary space for prostheses.
Topics: Adult; Humans; Splints; Molar; Masseter Muscle; Temporal Muscle; Occlusal Splints; Electromyography
PubMed: 38431564
DOI: 10.1186/s12903-024-04039-6 -
Diagnostics (Basel, Switzerland) Apr 2021The purpose of this study is to evaluate the effect of an electromyography-guided adjustment of an occlusal appliance on the management of Temporomandibular...
BACKGROUND
The purpose of this study is to evaluate the effect of an electromyography-guided adjustment of an occlusal appliance on the management of Temporomandibular disorder-related pain.
METHODS
Data from 40 adult patients (20 males and 20 females), who underwent treatment with occlusal appliances, were recorded. A total of 20 appliances were adjusted according to electromyographic data (group 1), while the others were adjusted by a clinical conventional procedure (group 2). Muscle pain to palpation, pain during articular movements and headache were recorded by a VAS score (from 0 to 100) before the beginning of treatment (T0), at T1 (4 weeks) and T2 (8 weeks).
RESULTS
Results showed a reduction of pain in both groups, with a better trend for group 1, where better results were achieved at T1 and maintained stability at T2, with an improved mean value regarding all parameters studied. After 8 weeks, only small recurrences started to occur in muscle pain to palpation in group 2.
CONCLUSIONS
An occlusal appliance seems to be able to achieve a clinical improvement of Temporomandibular disorder (TMD)-related pain and headache, independently from the adjustment procedure adopted. However, the use of a surface electromyographic activity of masticatory muscles (sEMG) device as an aid in the calibration procedure seems to allow a better trend because the improvement of symptoms was obtained before, after the first four weeks, with an improvement in percentages of all the variables investigated. While the conventional procedure obtained later the improvement.
PubMed: 33917788
DOI: 10.3390/diagnostics11040667 -
Journal of Clinical Medicine Dec 2020This clinical study was designed with the aim of fabricating four ceramic crowns using the conventional method and digital methods with three different intraoral...
This clinical study was designed with the aim of fabricating four ceramic crowns using the conventional method and digital methods with three different intraoral scanners and evaluate the marginal and internal fit as well as clinician satisfaction. We enrolled 20 subjects who required ceramic crowns in the upper or lower molar or the premolar. Impressions were obtained using digital scans, with conventional impressions (polyvinyl siloxane and desktop scanner) and three different intraoral scanners (EZIS PO, i500, and CS3600). Four lithium disilicate glass-ceramic crowns were fabricated for each patient. In the oral cavity, the proximal and occlusal adjustments were performed, and the marginal fit and internal fit were evaluated using the silicone replica technique. The clinician satisfaction score of the four crowns was evaluated as per the evaluations of the proximal and occlusal contacts made during the adjustment process and the marginal and internal fit. For statistical analysis, the differences among the groups were analyzed with one-way analysis of variance and Tukey HSD test as a post-test; Pearson correlation analysis was used for analyzing the correlations (α = 0.05). There was a significant difference in the marginal and internal fit of the ceramic crowns fabricated using three intraoral scanner types and one desktop scanner type ( < 0.001); there was a significant difference in the clinician satisfaction scores ( = 0.04). The clinician satisfaction score and marginal fit were significantly correlated (absolute marginal discrepancy and marginal gap) ( < 0.05). An impression technique should be considered for fabricating a ceramic crown with excellent goodness-of-fit. Further, higher clinician satisfaction could be obtained by reproducing the excellent goodness-of-fit using the intraoral scanning method as compared to the conventional method.
PubMed: 33327402
DOI: 10.3390/jcm9124035