-
Biomedicines Nov 2023To investigate the performance of the END-PAC model in predicting pancreatic cancer risk in individuals with new-onset diabetes (NOD). (Review)
Review
OBJECTIVES
To investigate the performance of the END-PAC model in predicting pancreatic cancer risk in individuals with new-onset diabetes (NOD).
METHODS
The PRISMA statement standards were followed to conduct a systematic review. All studies investigating the performance of the END-PAC model in predicting pancreatic cancer risk in individuals with NOD were included. Two-by-two tables, coupled forest plots and summary receiver operating characteristic plots were constructed using the number of true positives, false negatives, true negatives and false positives. Diagnostic random effects models were used to estimate summary sensitivity and specificity points.
RESULTS
A total of 26,752 individuals from four studies were included. The median follow-up was 3 years and the pooled risk of pancreatic cancer was 0.8% (95% CI 0.6-1.0%). END-PAC score ≥ 3, which classifies the patients as high risk, was associated with better predictive performance (sensitivity: 55.8% (43.9-67%); specificity: 82.0% (76.4-86.5%)) in comparison with END-PAC score 1-2 (sensitivity: 22.2% (16.6-29.2%); specificity: 69.9% (67.3-72.4%)) and END-PAC score < 1 (sensitivity: 18.0% (12.8-24.6%); specificity: 50.9% (48.6-53.2%)) which classify the patients as intermediate and low risk, respectively. The evidence quality was judged to be moderate to high.
CONCLUSIONS
END-PAC is a promising model for predicting pancreatic cancer risk in individuals with NOD. The score ≥3 should be considered as optimum cut-off value. More studies are needed to assess whether it could improve early pancreatic cancer detection rate, pancreatic cancer re-section rate, and pancreatic cancer treatment outcomes.
PubMed: 38002040
DOI: 10.3390/biomedicines11113040 -
Journal of Orthopaedic Surgery (Hong... 2020The purpose of this study was to investigate the surgical outcomes of total hip arthroplasty (THA) through direct anterior approach (DAA) performed by beginners by...
PURPOSE
The purpose of this study was to investigate the surgical outcomes of total hip arthroplasty (THA) through direct anterior approach (DAA) performed by beginners by comparing the outcomes after the introduction of DAA-THA between using a normal operating table and a traction table.
METHODS
The total subjects were 200 patients, there were 120 cases from the introduction of three surgeons using a normal table and 80 cases from two surgeons using a traction table. The surgical procedure was standardized, and a surgeon skilled in DAA entered the operating room and instructed the novice surgeons of DAA in all cases.
RESULTS
The mean operative time was no significant difference between the two groups ( = 0.093). The difference in slope of the operative time was no significant difference between the two groups ( value = 0.089). The mean fluoroscopy time and the mean blood loss were significant difference between the two groups ( < 0.05). The difference in slope of the fluoroscopy time and blood loss were significant difference between the two groups ( < 0.05). There were no intraoperative complications and no reoperations for any reason.
CONCLUSIONS
At the facility with a surgeon skilled in DAA, the use of a traction table in DAA did not increase the complication rate compared with the use of a normal operating table when the exclusion criteria for DAA were set and surgery was performed using intraoperative fluoroscopy under supervision by a skilled surgeon.
Topics: Aged; Arthroplasty, Replacement, Hip; Female; Fluoroscopy; Humans; Male; Operating Tables; Operative Time; Orthopedic Surgeons; Surgery, Computer-Assisted
PubMed: 32583712
DOI: 10.1177/2309499020923093 -
Infection Prevention in Practice Sep 2022Airborne bacteria present in the operating room may be a cause of surgical site infection, either contaminating the surgical wound directly, or indirectly via e.g....
Instrument tables equipped with local unidirectional airflow units reduce bacterial contamination during orthopedic implant surgery in an operating room with a displacement ventilation system.
BACKGROUND
Airborne bacteria present in the operating room may be a cause of surgical site infection, either contaminating the surgical wound directly, or indirectly via e.g. surgical instruments. The aim of this study was to evaluate if instrument and assistant tables equipped with local unidirectional airflow reduce bacterial contamination of the instrument area to ultra clean levels, during orthopedic implant surgery in an operating room with displacement ventilation.
METHODS
Local airflow units of instrument and assistant tables were either active or inactive. Colony forming units were sampled intraoperatively from the air above the instruments and from instrument dummies. A minimum of three air samples and two-three samples from instrument dummies were taken during each surgery. Samples were incubated on agar for total aerobic bacterial count. The mean air and instrument contamination during each surgery was calculated and used to analyze the difference in contamination depending on use of local airflow or not. All procedures were performed in the same OR.
RESULTS
188 air and 124 instrument samples were collected during 48 orthopedic implant procedures. Analysis showed that local unidirectional airflow above the surgical instruments significantly reduced the bacterial count in the air above assistant table (<0.001) and instrument table (=0.002), as well as on the instrument dummies from the assistant table (=0.001).
CONCLUSIONS
Instrumentation tables equipped with local unidirectional airflow protect the surgical instruments from bacterial contamination during orthopedic implant surgery and may therefore reduce the risk of indirect wound contamination.
PubMed: 35722048
DOI: 10.1016/j.infpip.2022.100222 -
Japanese Journal of Infectious Diseases Mar 2022Xpert Xpress Flu/RSV is a fast and automated real-time nucleic acid amplification tool for detecting influenza virus and respiratory syncytial virus (RSV). The aim of...
Xpert Xpress Flu/RSV is a fast and automated real-time nucleic acid amplification tool for detecting influenza virus and respiratory syncytial virus (RSV). The aim of this study was to verify the accuracy of Xpert Xpress Flu/RSV for detecting influenza virus and RSV. PubMed, EMBASE, Cochrane Library, and Web of Science databases were searched up to October 2020. The quality of the original research was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 guidelines. Meta-DiSc 1.4 software was used to analyze the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristic curve. Deek's funnel plot asymmetry test was used to evaluate the publication bias using the Stata 12.0 software. Ten studies with 25 fourfold tables were included in the analysis. The sensitivity of Xpert Xpress Flu/RSV for detecting influenza A, influenza B, and RSV were 0.97, 0.98, and 0.96, respectively, and the specificities were 0.97, 1.00, and 1.00, respectively. Compared with other common clinical real-time reverse transcription-polymerase chain reaction (RT-PCR), Xpert Xpress Flu/RSV is a valuable tool for diagnosing influenza virus and RSV with high sensitivity and specificity.
Topics: Humans; Influenza A virus; Influenza B virus; Influenza, Human; Molecular Diagnostic Techniques; Nasopharynx; Respiratory Syncytial Virus Infections; Respiratory Syncytial Virus, Human; Sensitivity and Specificity
PubMed: 34053954
DOI: 10.7883/yoken.JJID.2020.987 -
Frontiers in Oncology 2020Early prediction of recurrence and death risks is significant to the treatment of hepatocellular carcinoma (HCC) patients. We aimed to develop and validate prognosis...
Development and Validation of Nomograms Based on Gamma-Glutamyl Transpeptidase to Platelet Ratio for Hepatocellular Carcinoma Patients Reveal Novel Prognostic Value and the Ratio Is Negatively Correlated With P38MAPK Expression.
BACKGROUND
Early prediction of recurrence and death risks is significant to the treatment of hepatocellular carcinoma (HCC) patients. We aimed to develop and validate prognosis nomogram models based on the gamma-glutamyl transpeptidase (GGT)-to-platelet (PLT) ratio (GPR) for HCC and to explore the relationship between the GPR and inflammation-related signaling pathways.
METHODS
All data were obtained from 2000 to 2012 in the Affiliated Hospital of Qingdao University. In the training cohort, factors included in the nomograms were determined by univariate and multivariate analyses. In the training and validation cohorts, the concordance index (C-index) and calibration curves were used to assess predictive accuracy, and receiver operating characteristic curves were used to assess discriminative ability. Clinical utility was evaluated using decision curve analysis. Moreover, improvement of the predictive accuracy of the nomograms was evaluated by calculating the decision curve analysis, the integrated discrimination improvement, and the net reclassification improvement. Finally, the relationship between the GPR and inflammation-related signaling pathways was evaluated using the independent-samples t-test.
RESULTS
A larger tumor size and higher GPR were common independent risk factors for both disease-free survival (DFS) and overall survival (OS) in HCC (P < 0.05). Good agreement between our nomogram models' predictions and actual observations was detected by the C-index and calibration curves. Our nomogram models showed significantly better performance in predicting the HCC prognosis compared to other models (P < 0.05). Online webserver and scoring system tables were built based on the proposed nomogram for convenient clinical use. Notably, including the GPR greatly improved the predictive ability of our nomogram models (P < 0.05). In the validation cohort, p38 mitogen-activated protein kinase (P38MAPK) expression was significantly negatively correlated with the GPR (P < 0.01) and GGT (P = 0.039), but was not correlated with PLT levels (P = 0.063). And we found that P38MAPK can regulate the expression of GGT by quantitative real-time PCR and Western blotting experiments.
CONCLUSIONS
The dynamic nomogram based on the GPR provides accurate and effective prognostic predictions for HCC, and P38MAPK-GGT may be a suitable therapeutic target to improve the prognosis of HCC patients.
PubMed: 33344225
DOI: 10.3389/fonc.2020.548744 -
Pulmonology 2024To evaluate possible sex-related differences in the performance of the GOAL, a 4-item obstructive sleep apnea (OSA) screening instrument in adults.
OBJECTIVE
To evaluate possible sex-related differences in the performance of the GOAL, a 4-item obstructive sleep apnea (OSA) screening instrument in adults.
METHODS
Between July 2019 and June 2021, this cross-sectional study included consecutively recruited patients from one Brazilian sleep laboratory undergoing overnight polysomnography. Individuals with GOAL scores ≥ 2 of a maximum of 4 points are classified at high risk for OSA diagnosis. Actual OSA severity was based on the apnea-hypopnea index: ≥ 5.0/h as any OSA, ≥ 15.0/h as moderate-to-severe OSA, and ≥ 30.0/h as severe OSA. Performance of the GOAL instrument in women and men was assessed by the discriminatory ability (obtained from area under the curve [AUC]-Receiver Operating Characteristic curves) and 2×2 contingency tables.
RESULTS
A total of 2,978 subjects (55.3% males) were evaluated. The frequency of GOAL-defined OSA high-risk was statistically higher in men when compared to women (p < 0.001). The GOAL predictive parameters for screening all severity OSA levels were as follows: in females, sensitivity ranging from 58.2% to 78.3% and specificity ranging from 60.0% to 77.6%, while in males, sensitivity ranging from 90.5% to 96.9% and specificity from 20.7% to 46.8%. The GOAL questionnaire had similar discriminatory properties, assessed by AUC, in women and in men: i) any OSA: 0.741 vs. 0.771 (p = 0.204), ii) moderate-to-severe OSA: 0.727 vs. 0.737 (p = 0.595), and iii) severe OSA: 0.728 vs. 0.703 (p = 0.240); respectively.
CONCLUSIONS
The GOAL instrument emerges as a useful tool for screening adult individuals and displays similar performance in both women and men.
Topics: Humans; Sleep Apnea, Obstructive; Male; Female; Cross-Sectional Studies; Middle Aged; Adult; Polysomnography; Sex Factors; Mass Screening; Severity of Illness Index; Sensitivity and Specificity; Brazil; ROC Curve; Surveys and Questionnaires; Risk Factors; Aged
PubMed: 35151621
DOI: 10.1016/j.pulmoe.2022.01.004 -
Yonsei Medical Journal Jan 2022Acute respiratory viral infections pose significant morbidity and mortality, making it essential to diagnose respiratory viral infections rapidly. In this study, the... (Meta-Analysis)
Meta-Analysis
PURPOSE
Acute respiratory viral infections pose significant morbidity and mortality, making it essential to diagnose respiratory viral infections rapidly. In this study, the diagnostic efficacy of the Luminex xTAG Respiratory Virus Panel (RVP) FAST v2 test was evaluated on respiratory viral infections.
MATERIALS AND METHODS
Information was retrieved from electronic databases, including Embase, Web of Science, PubMed, and Cochrane Library, for systematic review. Studies that fulfilled predefined inclusion criteria were included. After the extraction of information, statistical software was utilized for quality evaluation, data analysis, and assessment of publication bias.
RESULTS
Eighty groups in fourfold tables from nine articles were included to perform statistical analyses. Therein, the mean specificity and mean sensitivity of Luminex xTAG RVP FAST v2 test for the detection of respiratory viral infections were 0.99 (0.98-0.99) and 0.88 (0.87-0.90), respectively. Additionally, the negative and positive likelihood ratios were 0.14 (0.11-0.19) and 87.42 (61.88-123.50), respectively. Moreover, the diagnostic odds ratio and area under the curve of summary receiver operating characteristic were 714.80 and 0.9886, respectively.
CONCLUSION
The Luminex xTAG RVP FAST v2 test could be a reliable and rapid diagnostic method for multiple respiratory viral infections.
Topics: Humans; Respiratory System; Respiratory Tract Infections; Sensitivity and Specificity; Virus Diseases; Viruses
PubMed: 34913289
DOI: 10.3349/ymj.2022.63.1.95 -
BioMed Research International 2020(CT) and (NG) are widely spread across the world. Asymptomatic or inconspicuous CT/NG infections are difficult to diagnose and treat. Traditional methods have the... (Meta-Analysis)
Meta-Analysis
BACKGROUND
(CT) and (NG) are widely spread across the world. Asymptomatic or inconspicuous CT/NG infections are difficult to diagnose and treat. Traditional methods have the disadvantages of low detection rate, inaccurate results, and long detection time. However, Xpert CT/NG makes up for the aforementioned shortcomings and has research value and popularization significance.
METHODS
PubMed, Embase, Cochrane Library, and Web of Science were systematically searched, and studies were screened using Xpert CT/NG for diagnosing CT/NG. QUADAS-2 was used to evaluate the quality of the eligible studies. Then, two groups of researchers independently extracted data from these studies. Meta-analyses of sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and the area under the curve (AUC) of the summary receiver operating characteristic (SROC) curve were conducted using Meta-DiSc 1.4. Finally, Deek's funnel plots were made using Stata 12.0 to evaluate publication bias.
RESULTS
14 studies were identified, and 46 fourfold tables were extracted in this meta-analysis. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing CT were 0.94 (95% confidence interval (CI): 0.93-0.95), 0.99 (95% CI: 0.99-1.00), 97.17 (95% CI: 56.76-166.32), 0.07 (95% CI: 0.04-0.12), 1857.25 (95% CI: 943.78-3654.86), and 0.9960, respectively. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing NG were 0.95 (95% CI: 0.93-0.96), 1.00 (95% CI: 1.00-1.00), 278.15 (95% CI: 152.41-507.63), 0.08 (95% CI: 0.06-0.12), 4290.70 (95% CI: 2161.78-8516.16), and 0.9980, respectively.
CONCLUSIONS
Xpert CT/NG had high diagnostic sensitivity and specificity for CT and NG. However, more evidence is required to confirm that Xpert CT/NG might serve as the primary method for detecting CT and NG and even the gold standard for diagnosis in the future.
Topics: Area Under Curve; Chlamydia Infections; Chlamydia trachomatis; Gonorrhea; Humans; Neisseria gonorrhoeae; Odds Ratio; ROC Curve; Sensitivity and Specificity
PubMed: 33102576
DOI: 10.1155/2020/2892734 -
Emergency Medicine International 2020Emergency decompression is needed in patients with tension pneumothorax, a life-threatening condition. The catheter-based needle thoracostomy was suggested using a...
INTRODUCTION
Emergency decompression is needed in patients with tension pneumothorax, a life-threatening condition. The catheter-based needle thoracostomy was suggested using a 5 cm catheter inserted into the 2nd intercostal space (ICS) and 5th ICS according to the ninth and tenth editions of Advanced Trauma Life Support, respectively. A catheter of suitable length may not be available immediately or the muscle structure of the chest wall may be modified in pneumothorax. Furthermore, alternative sites for needle thoracostomy and reference values of chest wall thickness (CWT) should be explored and warranted.
METHOD
CT scan data and medical data of 650 eligible patients from October 2016 to December 2016 were reviewed. CWT values at four ICSs as well as four variables, namely, age, weight, height, and body mass index (BMI) for both men and women were compared using a nonparametric method, namely, the Wilcoxon signed-rank test. The associations between CWT and the four variables were assessed using the Pearson correlation coefficient. The overall performance of BMI, weight, and height in predicting CWT > 5 cm was evaluated using the receiver-operating characteristic (ROC) curve. Finally, the prediction models were built by using the bootstrap method.
RESULTS
Four variables, namely, age, height, weight, and BMI, were compared between the men and women groups. All four variables differed significantly between the two groups, and CWTs at all ICSs, except for the 3rd ICS, differed significantly between the two groups. Among the women, the area under the ROC curve (AUROC) of BMI for predicting CWT > 5 cm at 2nd ICS was larger than the AUROC of weight and height. Among the men, the AUROC of weight for predicting CWT > 5 cm at 2nd ICS was larger than that of BMI and height. The reference value tables were provided for five proposed models for women and men, respectively. Under emergencies, the variable, BMI, or even weight itself, could be used for predicting a failure performance of the needle decompression. For women, CWT at 5th ICS was predicted over 5 cm at BMI over 25.9 kg/m or weight over 103.1 kg. For men, CWT at 5th ICS was predicted over 5 cm at BMI over 25.5 kg/m or weight over 157.4 kg.
CONCLUSION
Needle thoracostomy is the preferred first technique for many emergency providers for decompression. Therefore, a reference table for safe needle thoracostomy decompression at four usual sites, namely, 2nd ICS, 3rd CIS, 4th ICS, and 5th ICS, was recommended, which will enable paramedics and emergency specialists to rapidly determine CWT at the appropriate ICSs during emergencies.
PubMed: 33178460
DOI: 10.1155/2020/2070157 -
Medicine Nov 2022This meta-analysis aimed to explore the diagnostic value of diffusion kurtosis imaging (DKI) compared to mono-exponential diffusion weighted imaging (DWI) in the... (Meta-Analysis)
Meta-Analysis
BACKGROUND
This meta-analysis aimed to explore the diagnostic value of diffusion kurtosis imaging (DKI) compared to mono-exponential diffusion weighted imaging (DWI) in the diagnosis of breast cancer.
METHODS
A systematic electronic literature search (up to September 2020) was conducted for published English-language studies comparing the diagnostic values of DKI and DWI for the detection of breast cancer. The data of mean kurtosis (MK), mean diffusivity (MD), and apparent diffusion coefficient (ADC) were extracted to construct 2 × 2 contingency tables. The pooled sensitivities, specificities, and areas under the receiver operating characteristic curve (AUCs) were compared between DKI and DWI in the diagnosis of breast cancer.
RESULTS
Eight studies were finally included, with a total of 771 patients in the same population. Pooled sensitivities were 82.0% [95% confidence interval (95% CI), 78.2-85.3%] for ADC, 87.3% (95% CI, 83.9-90.1%) for MK, and 83.9% (95% CI, 80.2-87.1%) for MD. Pooled specificities were 81.1% (95% CI, 76.7-84.9%) for ADC, 85.1% (95% CI, 81.1-88.5%) for MK, and 83.2% (95% CI, 79.0-86.8%) for MD. According to the summary receiver operator characteristic curve analyses, the AUCwas 0.901 for ADC, 0.930 for MK, and 0.918 for MD (ADC vs MK, P = .353; ADC vs MD, P = .611). No notable publication bias was found, while significant heterogeneity was observed.
CONCLUSIONS
Although DKI is feasible for identifying breast cancer, MD and MK offer similar diagnostic performance to ADC values. Thus, we recommend that DKI should not be included in the routine evaluation of breast lesions now.
Topics: Humans; Female; Language; Sensitivity and Specificity; Diffusion Magnetic Resonance Imaging; Diffusion Tensor Imaging; Breast Neoplasms
PubMed: 36343063
DOI: 10.1097/MD.0000000000031574