Foot and Ankle Surgery : Official... Dec 2022Minimally-invasive Chevron and Akin osteotomy (MICA) represents the third-generation percutaneous hallux valgus surgery which is characterized by an extra-articular...
BACKGROUND
Minimally-invasive Chevron and Akin osteotomy (MICA) represents the third-generation percutaneous hallux valgus surgery which is characterized by an extra-articular osteotomy, stable internal fixation and a high potential for correction. Compared to other percutaneous techniques of the foot, MICA is generally regarded as an advanced and demanding surgical procedure with a flat learning curve. The aim of this study is to analyze a single-surgeons experience with his first 50 consecutive MICA procedures.
METHODS
Between May 2018 and February 2021, 50 consecutive MICA procedures performed by the author with the "K-wires-First technique" were prospectively analyzed focusing on surgery duration, number of fluoroscopies, correction results and surgery-associated complications. A modification of the original MICA technique as described by its inaugurators Redfern and Vernois allows the use of a standard-sized C-arm and aims to reduce revison rates and conversion to open surgery by placing the guidewires prior to performing the osteotomy.
RESULTS
The average surgery time for all MICA procedures was 46.8 min (SD 12.1, range 31-90 min). The average amount of fluoro shots required to perform MICA was n = 126.6 (SD 40.8, range 65-231). Comparing the preoperative and 6-week postoperative radiographs, the IMA decreased after MICA by a mean of 10.8° from 16.2° to 5.4° and the HVA by a mean of 22.1° from 30.6° to 8.5°. One case required intraoperative conversion to open hallux correction. There were 4 feet in three patients with secondary screw removal of the Chevron fixation due to prominent proximal screw tips.
CONCLUSIONS
Although the learning curve of 3rd generation MICA is flat and requires specific training and intensive practice, the rate of complications is not elevated compared to other percutaneous hallux valgus techniques. Strict adherence to the principles of 3rd generation MICA with stable fixation and meticulous intraoperative control of each surgical step helps to reduce surgery-associated complications. The learning curve showed a continous improvement in regard to surgery time and use of fluoroscopy. After 40 procedures, the surgery time consistently dropped under 45 min and required less than 100 fluoro-shots. The modified surgical technique may help reduce Chevron screw mal-positioning when using large C-arm fluoroscopy for this procedure.
Topics: Humans; Learning Curve; Minimally Invasive Surgical Procedures; Hallux Valgus; Osteotomy; Radiography; Bunion; Treatment Outcome
PubMed: 35882575
DOI: 10.1016/j.fas.2022.07.006 -
Medicine Feb 2020In this retrospective observational study, I aimed to report long-term follow-up results of femoral varus osteotomy in the treatment of Perthes disease patients who were... (Comparative Study)
Comparative Study Observational Study
Long-term follow-up results of femoral varus osteotomy in the treatment of Perthes disease, and comparison of open-wedge and closed-wedge osteotomy techniques: A retrospective observational study.
In this retrospective observational study, I aimed to report long-term follow-up results of femoral varus osteotomy in the treatment of Perthes disease patients who were between 6 and 8 years old at the onset of the disease with Herring B and C hip involvement. I also aimed to compare 2 different osteotomy techniques: open-wedge and closed-wedge femoral varus osteotomies.Patients with Perthes disease treated with femoral varus osteotomies were invited for final examination. Twenty two hips of 19 patients were evaluated. Mean follow-up period was 15.2 years. Patients were divided into 2 homogenous groups according to femoral osteotomy technique. In Group A (12 hips) open-wedge osteotomy, and in Group B (10 hips) closed-wedge osteotomy was performed.There were 15 male (78.9%) and 4 female (21.1%) patients. The median age at the onset of the disease was 7 years in Group A and B. The mean follow-up period was 16.2 years in Group A, and 11.4 years in Group B. According to Stulberg classification 5 hips (22.7%) were healed as Class I, 4 hips (18.2%) were healed as Class II, 12 hips (55.5%) were healed as Class III, and 1 hip (4.6%) was healed as Class IV. Also in Group A 4 hips (33.3%) were healed as Class I or II, 7 hips (58.3%) were healed as Class III, and 1 hip (8.3%) was healed as Class IV; in Group B 5 hips (50.0%) were healed as Class I or II, and 5 hips were healed as Class III (50.0%). There was no significant difference between the groups. According to Iowa scale, mean values were 92.6 in Group A and 92.4 in Group B. There was no significant difference between the groups. At the final follow-up mean center-edge angles of Group A and B were 16 and 22, the difference was significant.Long-term follow-up results showed that femoral varus osteotomy was an effective treatment method in Perthes disease patients who were between 6 and 8 years old with Herring B and C hip involvement at the onset of the disease. Hip joint congruency was obtained with femoral varus osteotomies, and closed-wedge osteotomy served more favorable center-edge angle results.
Topics: Child; Female; Humans; Legg-Calve-Perthes Disease; Male; Osteotomy; Retrospective Studies; Treatment Outcome
PubMed: 32049801
DOI: 10.1097/MD.0000000000019041 -
Journal of Orthopaedic Surgery (Hong... 2022Hallux valgus (HV) is a common foot deformity for which several corrective surgical procedures, with different osteotomy sites, have been reported. The purpose of the... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Hallux valgus (HV) is a common foot deformity for which several corrective surgical procedures, with different osteotomy sites, have been reported. The purpose of the present study was to systematically review randomized (RCTs) or controlled (CCTs) clinical trials and perform meta-analysis on outcomes of different osteotomy sites of the first metatarsal.
METHODS
An extensive literature search was conducted in PubMed and the Cochrane Library from January 1983 to July 2020. Studies were identified using the terms "hallux valgus" and "osteotomy". We included RCTs or CCTs comparing different locations of osteotomy for the first metatarsal bone (distal vs. mid-shaft, distal vs. proximal, and mid-shaft vs. proximal). The surgical outcomes included postoperative hallux valgus angle (HVA), intermetatarsal angle (IMA), American Orthopaedic Foot and Ankle Society (AOFAS) score, pain visual analog scale (VAS) score, perioperative complications and recurrence of deformity. We enrolled 10 studies with a total of 793 feet in the qualitative synthesis following full-text screening.
RESULTS
A majority of patients included in the enrolled trials showed mild to moderate deformity, with mean HVA <40°. Out of the 10 enrolled studies; six compared distal osteotomies with mid-shaft osteotomies and showed no significant differences in the surgical outcomes between the scarf and chevron groups; three RCTs compared distal osteotomies with proximal osteotomies with conflicting results, one RCT showed the superiority of proximal osteotomy while the other two RCTs showed equivalent outcomes; one study that compared between mid-shaft and proximal osteotomies showed equivalent outcomes between the groups.
CONCLUSION
For the management of mild to moderate HV deformity, we found no significant clinical and radiological differences between patients treated with scarf and chevron osteotomies. Further controlled trials comparing different sites of osteotomies for moderate to severe HV deformity are needed.
Topics: Hallux; Hallux Valgus; Humans; Metatarsal Bones; Osteotomy; Treatment Outcome
PubMed: 35836406
DOI: 10.1177/10225536221110473 -
Journal of Orthopaedic Research :... Dec 2020Dwyer (lateral calcaneal closing wedge) osteotomy is commonly used in surgical correction of heel varus deformity. The purpose of this study was to determine the effect...
Dwyer (lateral calcaneal closing wedge) osteotomy is commonly used in surgical correction of heel varus deformity. The purpose of this study was to determine the effect of wedge size and angle of osteotomy on deformity correction using preoperative imaging analysis with three-dimensional (3D) printed modeling. Seven patients diagnosed with pes cavovarus deformity who underwent Dwyer calcaneal osteotomy were identified retrospectively. Preoperative computed tomogrphy scans were used to create 3D printed models of the foot. After18 variations of osteotomy and fixation performed for each foot, Harris heel and Saltzman images were obtained. The angle between the tibia-talus axis and calcaneal-tuber axis was measured and compared to pre-osteotomy state. Change in the calcaneal lengths was also analyzed. The average degree correction of deformity per mm of bone resected was 3.8 ± 0.2 degrees in the Harris Heel view and 2.7 ± 0.8 degrees in the Saltzman view. A significant increase in correction was obtained with 10 mm compared with 5 mm wide wedges (P < .001). The difference in correction was not statistically significant between 30 and 45 degree cuts or osteotomy distance from the posterior calcaneal tuberosity, but a 45 degree sagittal angle resulted in less calcaneal shortening compared to 30 degrees (P = .02). A clinically driven method using patient-specific 3D models for determining effects of calcaneal osteotomy variables in correcting hindfoot alignment was developed. In summary, the amount of wedge resected impacts hindfoot alignment more than location and sagittal angle of the cut. Calcaneal shortening depends on sagittal angle of the cut.
Topics: Bone Malalignment; Calcaneus; Humans; Osteotomy; Patient-Specific Modeling; Printing, Three-Dimensional
PubMed: 32510162
DOI: 10.1002/jor.24772 -
International Journal of Oral and... Sep 2022The assessment of the stability of orthognathic surgery is often time-consuming, relies on manual re-identification of anatomical landmarks, and has been based on...
The assessment of the stability of orthognathic surgery is often time-consuming, relies on manual re-identification of anatomical landmarks, and has been based on short-term follow-up. The purpose of this study was to propose and validate a semi-automated approach for three-dimensional (3D) assessment of the long-term stability of segmental bimaxillary surgery. The approach was developed and validated using cone beam computed tomography scans obtained at 2 weeks and 2 years postoperative. The stability of the surgical outcome was calculated as 3D translational and rotational differences between the short- and long-term postoperative positions of the individual bone segments. To evaluate reliability, intra-class correlation coefficients were calculated at a 95% confidence interval on measurements of two observers. Ten class II and III patients (six male, four female; mean age 24.4 years), who underwent a combined three-piece Le Fort I osteotomy, bilateral sagittal split osteotomy, and genioplasty, were included in the study. Intra- and inter-observer reliability were excellent (range 0.82-0.99). The range of the mean absolute difference of the intra- and inter-observer translational and rotational measurements were 0.14 mm (0.13)-0.44 mm (0.50) and 0.20° (0.16)-0.92° (0.78). The approach has excellent reliability for 3D assessment of long-term stability of segmental bimaxillary surgery.
Topics: Adult; Cephalometry; Cone-Beam Computed Tomography; Female; Follow-Up Studies; Humans; Imaging, Three-Dimensional; Male; Maxilla; Orthognathic Surgical Procedures; Osteotomy, Le Fort; Osteotomy, Sagittal Split Ramus; Reproducibility of Results; Young Adult
PubMed: 35351347
DOI: 10.1016/j.ijom.2022.03.007 -
Zhongguo Xiu Fu Chong Jian Wai Ke Za... Jan 2022To review the research progress of surgical methods of osteotomy around the knee in the treatment of valgus knee osteoarthritis. (Review)
Review
OBJECTIVE
To review the research progress of surgical methods of osteotomy around the knee in the treatment of valgus knee osteoarthritis.
METHODS
The relevant literature on the surgical treatment of valgus knee osteoarthritis at home and abroad in recent years was reviewed, and the advantages, disadvantages, and effectiveness of different surgical methods of osteotomy around the knee were summarized.
RESULTS
For young and active patients with symptomatic valgus knee osteoarthritis, osteotomy around the knee is a safe and reliable treatment option. At present, the main surgical methods include medial closing wedge distal femoral osteotomy, lateral opening wedge distal femoral osteotomy, medial closing wedge high tibial osteotomy, and lateral opening wedge high tibial osteotomy. The indications, advantages, and disadvantages of different osteotomies are different, and the selection of appropriate surgical method is the key to achieve good effectiveness.
CONCLUSION
There are many osteotomies in the treatment of valgus knee osteoarthritis. In order to achieve good results, improve survival rate, and reduce postoperative complications, the most reasonable surgical strategy needs to be developed according to different situations.
Topics: Humans; Knee; Knee Joint; Osteoarthritis, Knee; Osteotomy; Tibia; Treatment Outcome
PubMed: 35038808
DOI: 10.7507/1002-1892.202108009 -
ORL; Journal For Oto-rhino-laryngology... 2020Osteotomy of nasal bones in rhinoplasty is associated with postsurgical morbidities. Recent evidence has suggested that a surgical method applying piezoelectric... (Meta-Analysis)
Meta-Analysis
INTRODUCTION
Osteotomy of nasal bones in rhinoplasty is associated with postsurgical morbidities. Recent evidence has suggested that a surgical method applying piezoelectric ultrasound waves for nasal osteotomies in rhinoplasty reduces soft tissue damage and causes less postsurgical morbidities compared to conventional methods. The purpose of this study is to compare clinical outcomes of piezoelectric and conventional lateral nasal osteotomies in rhinoplasty.
METHODS
We searched PubMed, CENTRAL, and Web of Science up to 17 August 2019 for studies comparing postoperative outcomes of piezoelectric and conventional lateral osteotomies in rhinoplasty. We included studies comparing results of patients subjected to piezoelectric or conventional lateral nasal osteotomies in rhinoplasty. For outcomes, we considered postoperative pain, eyelid edema, periorbital ecchymosis, and intraoperative mucosal injury.
RESULTS
For eyelid edema, a statistically significant difference in favor of piezoelectric osteotomy was documented within the first 3 postoperative days (standardized mean difference [SMD] = -0.65; 95% CI = -1.18, -0.12, p = 0.02; I2 = 69%) and on postoperative day 7 (SMD = -0.69; 95% CI = -1.47, -0.09; p = 0.08; I2 = 85%). This was also the case for periorbital ecchymosis within the first 3 postoperative days (SMD = -0.85; 95% CI = -1.42, -0.28; p = 0.004; I2 = 72%) and on postoperative day 7 (SMD = -0.52; 95% CI = -0.79, -0.24; p = 0.0003; I2 = 71%). Intraoperative mucosal injury (OR = 0.06; 95% CI = 0.01, 0.53; p = 0.01; Ι2 = 0%) and postoperative pain (SMD = -0.99; 95% CI = -1.78, -0.11; p = 0.01; I2 = 49%) were also statistically lower during piezoelectric osteotomies.
CONCLUSIONS
This study shows that lateral piezoelectric osteotomy in rhinoplasty decreases postoperative pain, edema, ecchymosis, and intraoperative mucosa injuries compared to the conventional osteotomy technique with a chisel. Piezoelectric osteotomies are especially associated with less postoperative edema and ecchymosis in osteotomies not executed under direct vision.
Topics: Ecchymosis; Edema; Humans; Nasal Bone; Osteotomy; Piezosurgery; Postoperative Complications; Rhinoplasty; Treatment Outcome
PubMed: 32320977
DOI: 10.1159/000506707 -
Journal of the American Veterinary... Apr 2022To report clinical experience using virtual surgical planning (VSP) and surgical application of 3D printed custom surgical guides to facilitate uni- and biapical...
Accuracy of virtual surgical planning and custom three-dimensionally printed osteotomy and reduction guides for acute uni- and biapical correction of antebrachial deformities in dogs.
OBJECTIVE
To report clinical experience using virtual surgical planning (VSP) and surgical application of 3D printed custom surgical guides to facilitate uni- and biapical correction of antebrachial deformities in dogs.
ANIMALS
11 dogs (13 antebrachial deformity corrections).
PROCEDURES
Using CT-based bone models, VSP was performed, and surgical guides were designed and 3D printed. The guides were used to execute osteotomies and align bone segments. Postoperative CTs were obtained to compare limb alignment with the VSP. Long-term assessment of lameness and cosmesis were compared with preoperative status.
RESULTS
Guides were successfully utilized and postoperative analysis was available for 10 of 13 deformities. Guides were abandoned in 2 deformities due to soft tissue tension. Evaluation of postoperative frontal, sagittal, axial, and translational limb alignment revealed that over 90% of parameters were within the acceptable range of ≤ 5° angulation and rotation or ≤ 5 mm of translation from the VSP. Lameness scores were improved in 7/8 deformities with associated preoperative lameness, and posture was improved in 10/10 deformities in which guides were deployed. Complications included reduced range of carpal motion (n = 2), implant sensitivity (n = 2), fracture (n = 1), and tendon laceration (n = 1).
CLINICAL RELEVANCE
VSP and customized surgical guide application facilitated accurate antebrachial limb deformity correction in the majority of deformities in this case series. The use of VSP and 3D printed guides would appear to be a viable and accurate approach for correction of both uni- and biapical antebrachial deformities in dogs.
Topics: Dogs; Animals; Forelimb; Lameness, Animal; Osteotomy; Plastic Surgery Procedures; Printing, Three-Dimensional; Dog Diseases
PubMed: 35460550
DOI: 10.2460/javma.21.09.0419 -
Aesthetic Plastic Surgery Jun 2023Piezosurgery use has become increasingly prevalent in osteotomies. Piezoelectric ultrasound waves can cut bone effectively, and some studies have shown reduced... (Review)
Review
Piezosurgery use has become increasingly prevalent in osteotomies. Piezoelectric ultrasound waves can cut bone effectively, and some studies have shown reduced post-operative morbidities compared to conventional osteotomies. Oedema and ecchymosis are common complications of rhinoplasty and can impact patient satisfaction, wound healing, and recovery. We aim to provide an up-to-date comparison of post-operative oedema and ecchymosis in piezosurgery and conventional osteotomies. A literature search was conducted using the following online libraries; Pubmed, Cochrane, Science Direct, and ISRCTN (International Standard Randomised Controlled Trial Number). English publications between 2015 and 2020 were included. A systematic review was completed, and a comparison of oedema and ecchymosis in piezosurgery and conventional osteotomies was examined alongside other outcomes such as pain, mucosal injury, and surgery time. Eight randomised controlled trials (RCTs) met our criteria with a combined total of 440 patients: 191 male and 249 female. Piezosurgery had statistically significant (p < 0.05) reduction in short-term oedema compared to conventional osteotomies in 75% of the papers included, and in 50% this persisted across the whole follow-up period. Similarly, ecchymosis scoring was initially statistically lower (p < 0.05) in piezosurgery in 87.5% of the RCTs, and in 75% this persisted across the whole follow-up period. A reduction in pain (p < 0.05) and mucosal injury (p < 0.05) was also seen in piezoelectric osteotomies. The length of surgery time varied. Piezoelectric osteotomies reduce oedema and ecchymosis compared to conventional osteotomies, in addition to improving pain and mucosal injury. However, disadvantages such as length of surgery time and cost have been reported. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Topics: Male; Female; Humans; Rhinoplasty; Ecchymosis; Piezosurgery; Osteotomy; Edema; Pain; Randomized Controlled Trials as Topic
PubMed: 36163553
DOI: 10.1007/s00266-022-03100-5 -
PloS One 2021The aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the...
OBJECTIVES
The aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the instrument design in comparison to the implant design, and to determinate a possible correlation between the insertion torque and initial stability quotient (ISQ).
MATERIALS AND METHODS
Four groups were identified in accordance with the osteotomy technique used (n = 10 implants per group): group G1, osteotomy using the recommended drilling sequence; group G2, osteotomy using an undersized compactor drill; group G3, osteotomy using an undersized drill; and group G4, osteotomy using universal osseodensification drills. Two polyurethane blocks were used: block 1, with a medullary portion of 10 pounds per cubic foot (PCF 10) and with a 1 mm cortical portion of PCF 40, and block 2, with a medullary of PCF 15 and with a 2 mm cortical portion of PCF 40. Tapered implants of 4 mm in diameter and 11 mm in length were used. The insertion torque (IT) and ISQ were measured. The dimensions of the final instrument used in each group and the dimensions of the implant were used to calculate the total area of each part, and these data were compared.
RESULTS
Differences between the four groups were found for IT and ISQ values depending on the technique used for the osteotomy in the two synthetic bone models (p < 0.0001). All groups showed lower values of initial stability in block 1 than in block 2.
CONCLUSIONS
Undersized osteotomies with instruments designed according to the implant body significantly increased the initial stability values compared to beds prepared with universal drills and using the drilling sequence standardized by the manufacturer.
Topics: Bone Density; Bone Diseases, Metabolic; Bone and Bones; Brazil; Dental Implantation, Endosseous; Humans; Osteotomy; Pilot Projects; Polyurethanes; Prostheses and Implants; Torque
PubMed: 34618848
DOI: 10.1371/journal.pone.0257985