Chemosphere Dec 2022Lack of microplastics (MP) toxicity studies involving environmentally relevant concentrations and exposure times is concerning. Here we analyzed the potential adverse...
Lack of microplastics (MP) toxicity studies involving environmentally relevant concentrations and exposure times is concerning. Here we analyzed the potential adverse effects of low density polyethylene (LDPE) MP at environmentally relevant concentration in sub-chronic exposure to two amphipods Gmelinoides fasciatus and Gammarus lacustris, species that naturally compete with each other for their habitats. 14-day exposure to 2 μg/L (8 particles/L corresponding to low exposure) and 2 mg/L (∼8400 particles/L, corresponding to high exposure) of 53-100 μm LDPE MP were used to assess ingestion and egestion of MP, evaluate its effects on amphipod mortality, swimming ability and oxidative stress level. Both amphipod species were effectively ingesting and egesting LDPE MP. On the average, 0.8 and 2.5 MP particles were identified in the intestines of each amphipod exposed to 2 μg/L and 2 mg/L LDPE MP, respectively. Therefore, intestinal MP after 14-day exposure did not fully reflect the differences in LDPE MP exposure concentrations. Increased mortality of both amphipods was observed at 2 mg/L LDPE MP and in case of G. lacustris also at 2 μg/L exposure. The effect of LDPE on swimming activity was observed only in case of G. fasciatus. Oxidative stress marker enzymes SOD, GPx and reduced glutathione GSH varied according to amphipod species and LDPE MP concentration. In general G. lacustris was more sensitive towards LDPE MP induced oxidative stress. Overall, the results suggested that in MP polluted environments, G. lacustris may lose its already naturally low competitiveness and become overcompeted by other more resistant species. The fact that in the sub-chronic foodborne exposure to environmentally relevant and higher LDPE MP concentrations all the observed toxicological endpoints were affected refers to the potential of MP to affect and disrupt aquatic communities in the longer perspective.
Topics: Animals; Microplastics; Amphipoda; Plastics; Polyethylene; Water Pollutants, Chemical; Glutathione; Superoxide Dismutase
PubMed: 36167206
DOI: 10.1016/j.chemosphere.2022.136599 -
Biodegradation Jun 2024To date, enumerable fungi have been reported to participate in the biodegradation of several notorious plastic materials following their isolation from soil of... (Review)
Review
To date, enumerable fungi have been reported to participate in the biodegradation of several notorious plastic materials following their isolation from soil of plastic-dumping sites, marine water, waste of mulch films, landfills, plant parts and gut of wax moth. The general mechanism begins with formation of hydrophobin and biofilm proceding to secretion of specific plastic degarding enzymes (peroxidase, hydrolase, protease and urease), penetration of three dimensional substrates and mineralization of plastic polymers into harmless products. As a result, several synthetic polymers including polyethylene, polystyrene, polypropylene, polyvinyl chloride, polyurethane and/or bio-degradable plastics have been validated to deteriorate within months through the action of a wide variety of fungal strains predominantly Ascomycota (Alternaria, Aspergillus, Cladosporium, Fusarium, Penicillium spp.). Understanding the potential and mode of operation of these organisms is thus of prime importance inspiring us to furnish an up to date view on all the presently known fungal strains claimed to mitigate the plastic waste problem. Future research henceforth needs to be directed towards metagenomic approach to distinguish polymer degrading microbial diversity followed by bio-augmentation to build fascinating future of waste disposal.
Topics: Plastics; Polyurethanes; Polymers; Polyethylene; Biodegradation, Environmental; Alternaria
PubMed: 37665521
DOI: 10.1007/s10532-023-10053-2 -
Scientific Reports Sep 2023Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing...
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Topics: Humans; Female; Middle Aged; Aged; Male; Arthroplasty, Replacement, Hip; Risk Factors; Ceramics; Correlation of Data; Polyethylene
PubMed: 37730762
DOI: 10.1038/s41598-023-42809-4 -
International Journal of Environmental... Feb 2023Microplastics in freshwater environments pose a serious threat to living beings. Polyethylene microplastics (PE-MP) are the type most used around the world as microbeads...
Microplastics in freshwater environments pose a serious threat to living beings. Polyethylene microplastics (PE-MP) are the type most used around the world as microbeads in personal care products, and they have been found in aquatic organisms. The behavior and toxicity of fluorescent PE-MP spheres with an average diameter of 58.9 μm were studied in adult, juvenile and embryo zebrafish (). The adults were studied for genotoxicity, cytotoxicity, histology and biochemical markers. Juveniles underwent a follow-up in the gastrointestinal (GI) tract with histologic observations, and embryos were studied for embryotoxicity with the FET-test. In adults, micronucleus test and comet assays found neither genotoxicity after acute exposure for 96 h at concentrations of 0.0, 12.5, 50 and 100 mg.L, nor cytotoxicity through the nuclear abnormalities test. Acetylcholinesterase (AChE), Glutathione-S-Transferase (GST) and Lactate Dehydrogenase (LDH) activities were measured in adults exposed for 96 h. The AChE and GST activities were significantly changed, while no changes occurred for LDH. In conclusion, these PE-MP spheres did not cause serious toxic effects in zebrafish because there was no internalization. The observed biochemical changes in AChE and GST may be associated with GI microbiological dysbiosis, previously reported. The PE-MP spheres in the intestine of juveniles remained present for 12-15 days on average after the post-exposure clearance study, showing a slow depuration. The histological analysis, in adults, found no internalization of these microbeads, with complete depuration. The PE-MP spheres did not cross the chorion barrier, showing no embryotoxic effects after exposures at 0.0, 6.25, 12.5, 50.0 or 100.0 mg.L for 96 h.
Topics: Animals; Microplastics; Zebrafish; Plastics; Polyethylene; Acetylcholinesterase; Water Pollutants, Chemical
PubMed: 36834310
DOI: 10.3390/ijerph20043617 -
Scientific Reports Apr 2023The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The... (Meta-Analysis)
Meta-Analysis
The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The first outcome of interest was to investigate the mean concentration in serum of Cr and Co using different material combinations and to verify whether their concentrations change significantly using different patterns of head and liner in THA. The second outcome of interest was to investigate whether the time elapsed from the index surgery to the follow-up, BMI, sex, and side exert an influence on the mean concentration of Cr and Co in serum in patients who have undergone THA. The following material combinations were investigated (head-liner): Ceramic-Co Cr (CoCr), CoCr-CoCr, CoCr-Polyethylene, CoCr high carbide-CoCr high carbide. Data from 2756 procedures were retrieved. The mean length of follow-up was 69.3 ± 47.7 months. The ANOVA test evidenced good comparability in age, length of follow-up, BMI, and sex (P > 0.1). In patients who have undergone THA, the mean concentration in the serum of Co ranged between 0.5 µg/L and 3.5 µg/L, and the mean concentration of Cr from 0.6 to 2.6 µg/L. The difference in the concentration of Co and Cr in serum is strictly related to the implant configuration, with the coupling CoCr-CoCr showing the highest and CoCr-Polyethylene showing the lowest concentration. Patient characteristics, BMI, sex, side and the time elapsed from the index surgery to the last follow-up did not exert a significant influence on the concentration of Co and Cr in serum in patients who have undergone total hip arthroplasty (THA).
Topics: Humans; Arthroplasty, Replacement, Hip; Cobalt; Chromium; Hip Prosthesis; Bayes Theorem; Network Meta-Analysis; Polyethylene; Prosthesis Design
PubMed: 37106086
DOI: 10.1038/s41598-023-34177-w -
BMC Molecular and Cell Biology May 2023For the purpose of skeletal muscle engineering, primary myoblasts (Mb) and adipogenic mesenchymal stem cells (ADSC) can be co-cultured and myogenically differentiated....
BACKGROUND
For the purpose of skeletal muscle engineering, primary myoblasts (Mb) and adipogenic mesenchymal stem cells (ADSC) can be co-cultured and myogenically differentiated. Electrospun composite nanofiber scaffolds represent suitable matrices for tissue engineering of skeletal muscle, combining both biocompatibility and stability Although growth differentiation factor 11 (GDF11) has been proposed as a rejuvenating circulating factor, restoring skeletal muscle function in aging mice, some studies have also described a harming effect of GDF11. Therefore, the aim of the study was to analyze the effect of GDF11 on co-cultures of Mb and ADSC on poly-ε-caprolactone (PCL)-collagen I-polyethylene oxide (PEO)-nanofibers.
RESULTS
Human Mb were co-cultured with ADSC two-dimensionally (2D) as monolayers or three-dimensionally (3D) on aligned PCL-collagen I-PEO-nanofibers. Differentiation media were either serum-free with or without GDF11, or serum containing as in a conventional differentiation medium. Cell viability was higher after conventional myogenic differentiation compared to serum-free and serum-free + GDF11 differentiation as was creatine kinase activity. Immunofluorescence staining showed myosine heavy chain expression in all groups after 28 days of differentiation without any clear evidence of more or less pronounced expression in either group. Gene expression of myosine heavy chain (MYH2) increased after serum-free + GDF11 stimulation compared to serum-free stimulation alone.
CONCLUSIONS
This is the first study analyzing the effect of GDF11 on myogenic differentiation of Mb and ADSC co-cultures under serum-free conditions. The results of this study show that PCL-collagen I-PEO-nanofibers represent a suitable matrix for 3D myogenic differentiation of Mb and ADSC. In this context, GDF11 seems to promote myogenic differentiation of Mb and ADSC co-cultures compared to serum-free differentiation without any evidence of a harming effect.
Topics: Humans; Mice; Animals; Nanofibers; Tissue Scaffolds; Polyethylene; Polyesters; Mesenchymal Stem Cells; Myoblasts; Cell Differentiation; Polyethylene Glycols; Collagen; Bone Morphogenetic Proteins; Growth Differentiation Factors
PubMed: 37189080
DOI: 10.1186/s12860-023-00478-1 -
Waste Management (New York, N.Y.) Jan 2022The establishment of a method of separation of materials from Tetra Pak waste to obtain products for use as raw material, fuel or other purposes was investigated in this...
The establishment of a method of separation of materials from Tetra Pak waste to obtain products for use as raw material, fuel or other purposes was investigated in this study. First, the feasibility of hydrothermal treatment for the production of a solid fuel (hydrochar) and solid fraction formed by polyethylene and aluminum, called composite was analyzed. The results indicated that hydrothermal treatment performed at 240 °C yield the formation of hydrochar with good properties for its use as fuel and a composite of polyethylene and aluminum. The best conversion and separation of the cardboard and polyethylene/aluminum were obtained using 120 min as operating time. Then, the recovery of the aluminum fraction from the composite by using spent olive oil waste was studied. A partial separation of the composite layers (polyethylene and aluminum) was accomplished with improved aluminum purity for higher operating temperatures. Finally, the operating conditions of the pyrolysis process for the production of a solid (char) and high purity composite (aluminum) were optimized. The characterization results indicated that both char and aluminum resulting from the pyrolysis of the Tetra Pak at 400 °C still have a significant amount of polyethylene while higher purity levels of aluminum can be obtained at temperatures equal of higher than 500 °C.
Topics: Aluminum; Plastics; Polyethylene; Pyrolysis; Temperature
PubMed: 34794036
DOI: 10.1016/j.wasman.2021.11.007 -
Archives of Orthopaedic and Trauma... Mar 2023Aseptic loosening remains a challenging problem after total hip arthroplasty. Accurate cup placement and supplementation of antioxidants in acetabular liners might... (Randomized Controlled Trial)
Randomized Controlled Trial
Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up.
BACKGROUND
Aseptic loosening remains a challenging problem after total hip arthroplasty. Accurate cup placement and supplementation of antioxidants in acetabular liners might reduce material failure rates. The aim of this study is to assess the effect of the cup position on the wear behaviour of UHMWPE-XE and UHMWPE-X liners in vivo using virtual radiographs.
METHODS
We conducted a prospective, randomized, controlled, multicenter trial. Clinical data of 372 probands were analyzed. Anteroposterior pelvic X-rays of 324 patients immediately postoperatively and after 1 and 5 years were evaluated by the RayMatch® analysis software regarding cup position and wear behaviour.
RESULTS
Mean cup anteversion was 20.3° (± 7.4) and inclination was 41.9° (± 7.0) postoperatively. 62.3% of all patients had an anteversion and inclination within the Lewinnek safe zone. Anterior and anterolateral approaches led to significantly higher cup anteversion compared to lateral approaches (27.3° ± 5.5; 20.9° ± 7.2; 17.5° ± 6.6; p < 0.001 and p = 0.001, respectively). Mean anteversion increased to 24.6° (± 8.0) after 1 year (p < 0.001). Only one revision occurred because of implant dislocation. Wear rates from UHMWPE-X and UHMWPE-XE did not differ significantly. Anteversion angles ≥ 25° correlated to increased polyethylene wear (23.7 µm/year ± 12.8 vs. 31.1 µm/year ± 22.8, p = 0.012) and this was amplified when inclination angles were ≥ 50° (23.6 µm/year ± 12.8 vs. 38.0 µm/year ± 22.7, p = 0.062).
CONCLUSION
Anterior approaches lead to the highest inaccuracy of cup placement, but cup positioning outside the Lewinnek safe zone does not necessarily cause higher dislocation rates. Moreover, mean anteversion increased by approximately four degrees within the first year after operation, which is expected to be functional due to a regularization of pelvic tilt after intervention. Mid-term wear rates of UHMWPE-X and UHMWPE-XE liners are comparable, but steep cup positions lead to significantly increased polyethylene wear. In summary, a re-evaluation of target zones for intraoperative cup positioning might be considered. In the long-term reduced oxidative embrittlement could lead to superior wear behaviour of vitamin E-blended liners.
Topics: Humans; Arthroplasty, Replacement, Hip; Polyethylene; Prospective Studies; Vitamin E; Follow-Up Studies; Prosthesis Design; Hip Prosthesis; Acetabulum; Joint Dislocations
PubMed: 35397656
DOI: 10.1007/s00402-022-04424-2 -
Scientific Reports Jul 2022Degradation and fragmentation of plastics in the environment are still poorly understood. This is partly caused by the lack of long-term studies and methods that...
Degradation and fragmentation of plastics in the environment are still poorly understood. This is partly caused by the lack of long-term studies and methods that determine weathering duration. We here present a novel study object that preserves information on plastic age: microplastic (MP) resin pellets from the wreck of the SS Hamada, a ship that foundered twenty-nine years ago at the coast of Wadi el Gemal national park, Egypt. Its sinking date enabled us to precisely determine how long MP rested in the wreck and a nearby beach, on which part of the load was washed off. Pellets from both sampling sites were analyzed by microscopy, X-ray tomography, spectroscopy, calorimetry, gel permeation chromatography, and rheology. Most pellets were made of low-density polyethylene, but a minor proportion also consisted of high-density polyethylene. MP from inside the wreck showed no signs of degradation compared to pristine reference samples. Contrary, beached plastics exhibited changes on all structural levels, which sometimes caused fragmentation. These findings provide further evidence that plastic degradation under saltwater conditions is comparatively slow, whereas UV radiation and high temperatures on beaches are major drivers of that process. Future long-term studies should focus on underlying mechanisms and timescales of plastic degradation.
Topics: Egypt; Environmental Monitoring; Indian Ocean; Plastics; Polyethylene; Water Pollutants, Chemical
PubMed: 35831329
DOI: 10.1038/s41598-022-15310-7 -
Knee Surgery, Sports Traumatology,... Mar 2023Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional...
PURPOSE
Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional polyethylene (CPE) wear. This study aims to analyse whether HXLPE is as safe as CPE and could improve the TKA clinical and radiological results in a long-term follow-up.
METHODS
This retrospective study included all consecutive starting series of 223 patients with severe primary knee osteoarthritis (OA), with a minimum follow-up of 10 years treated between July 1st, 2007, and July 31st, 2010. After excluding patients who did not respect the inclusion and exclusion criteria, 128 patients were included in the analysis of this study. The patients were then divided into two groups according to the type of polyethylene (PE) implanted: CPE or HXLPE liners. All patients were evaluated for clinical and radiological parameters, causes and revision rates related to the type of PE implanted.
RESULTS
HXLPE appears to be as safe as CPE in TKA, reporting no higher revisions for osteolysis, prosthesis loosening, infection, and mechanical failure. Nevertheless, no statistically significant differences were found between the two groups in the clinical and radiological outcomes evaluated.
CONCLUSIONS
Clinical, radiological results, and revision rates are similar between HXLPE and CPE in TKA after 10 years of follow-up, although HXLPE benefits remain controversial.
LEVEL OF EVIDENCE
III.
Topics: Humans; Polyethylene; Arthroplasty, Replacement, Knee; Follow-Up Studies; Retrospective Studies; Prosthesis Design; Prosthesis Failure; Arthroplasty, Replacement, Hip; Hip Prosthesis
PubMed: 36409325
DOI: 10.1007/s00167-022-07226-6