Reviews in Cardiovascular Medicine Jun 2020Infective endocarditis (IE) represents one of the most challenging clinical entities, requiring a multidisciplinary approach. The increasing number of surgical and... (Meta-Analysis)
Meta-Analysis
Infective endocarditis (IE) represents one of the most challenging clinical entities, requiring a multidisciplinary approach. The increasing number of surgical and transcatheter heart valves replacements performed annually lead to a higher incidence of prosthetic valve endocarditis. Transcatheter aortic valve implantation (TAVI) brought a new alternative for the treatment of aortic stenosis and a new subgroup of IE with its features. We aimed to compare the incidence of IE in TAVI and surgical valve replacement (SAVR) to identify risk factors for TAVI-IE, evaluate the possible impact on mortality, and clarify the best treatment strategies. A digital scan in PubMed and SCOPUS databases was performed. 68 publications were selected to perform a meta-analysis and systematic review on epidemiology, risk factors, and mortality predictors in TAVI-IE. No significant difference in IE rate was noted between patients with TAVI and those with SAVR for in-hospital, early, mid-term and late IE. Male gender, intubation, new pacemaker implantation IE and CKD were correlated with TAVI-IE. Surgical treatment was performed in 22.3% of cases. Overall mortality for the pooled cohort was 38.3%. In a multivariate logistic regression model, surgical treatment and self-expandable device were linked to lower mortality in TAVI-IE. Even if the invasive procedure can trigger bacteremia, exposing the TAVI valve to future infection, no significant difference in IE rate was noted in our analysis between patients with TAVI and those with SAVR for in-hospital, early, mid-term and late IE. Surgical treatment of TAVI-IE can be a viable option in patients with a prohibitive risk score.
Topics: Aged; Aged, 80 and over; Endocarditis; Female; Heart Valve Prosthesis; Humans; Incidence; Male; Middle Aged; Prognosis; Prosthesis-Related Infections; Risk Assessment; Risk Factors; Transcatheter Aortic Valve Replacement
PubMed: 32706214
DOI: 10.31083/j.rcm.2020.02.68 -
Clinical Infectious Diseases : An... May 2021International guidelines recommend rifampin-based combinations for staphylococcal prosthetic valve endocarditis (PVE). However, no robust clinical data support this...
BACKGROUND
International guidelines recommend rifampin-based combinations for staphylococcal prosthetic valve endocarditis (PVE). However, no robust clinical data support this recommendation, and rifampin tolerability is an issue. We aimed to evaluate the impact of rifampin for the treatment of staphylococcal PVE.
METHODS
An observational retrospective cohort study of all adults with staphylococcal PVE (modified Duke criteria) was conducted in 3 referral centers for endocarditis, during years 2000-2018. Primary outcome measurement was 1-year mortality.
RESULTS
We enrolled 180 patients with PVE due to Staphylococcus aureus (n = 114, 63.3%), or coagulase-negative staphylococci (n = 66, 36.7%), on bioprosthesis (n = 111, 61.7%), mechanical valve (n = 67, 37.2%), or both (n = 2). There were 132 males (73.3%), and mean age was 70.4 ± 12.4 years. Valvular surgery was performed in 51/180 (28.3%) cases. Despite all isolates were susceptible to rifampin, only 101 (56.1%) were treated with rifampin, for a median duration of 33.0 days, whereas 79 (43.9%) received no rifampin. Baseline characteristics were similar in both groups. One-year mortality was, respectively, 37.6% (38/101), and 31.6% (25/79), in patients treated with, or without, rifampin (P = .62). Relapse rates were 5.9% (6/101), and 8.9% (7/79), P = .65. Patients treated with rifampin had longer hospital length-of-stay: 42.3 ± 18.6 vs 31.3 ± 14.0 days (P < .0001). On multivariate analysis, only cerebral emboli (odds ratio [OR] 2.95, 95% confidence interval [CI], 1.30-6.70, P = .009), definite endocarditis (OR 7.15, 95% CI, 1.47-34.77, P = .018), and methicillin-resistant S. aureus (OR 6.04, 95% CI, 1.34-27.26, P = .019), were associated with 1-year mortality.
CONCLUSIONS
A large proportion (43.9%) of staphylococcal PVE received no rifampin. One-year survival and relapse rates were similar in patients treated with or without rifampin.
Topics: Adult; Aged; Aged, 80 and over; Endocarditis; Endocarditis, Bacterial; Heart Valve Prosthesis; Humans; Male; Methicillin-Resistant Staphylococcus aureus; Middle Aged; Prosthesis-Related Infections; Retrospective Studies; Rifampin; Staphylococcal Infections
PubMed: 32706879
DOI: 10.1093/cid/ciaa1040 -
The Journal of Thoracic and... Mar 2021
Topics: Aortic Valve; Aortic Valve Stenosis; Bioprosthesis; Heart Valve Prosthesis; Humans
PubMed: 33431205
DOI: 10.1016/j.jtcvs.2020.12.018 -
Deutsches Arzteblatt International Oct 2023In Germany, a total of 38 547 heart valve procedures were performed in 2022. With a growing number of patients undergoing the surgical and interventional implantation of... (Review)
Review
BACKGROUND
In Germany, a total of 38 547 heart valve procedures were performed in 2022. With a growing number of patients undergoing the surgical and interventional implantation of heart valves, the incidence of prosthetic endocarditis is also rising.
METHODS
We summarize the current state of the prophylaxis, diagnosis, and treatment of prosthetic endocarditis in a selective review of the literature.
RESULTS
Prosthetic endocarditis accounts for 10-30% of all cases of endocarditis. As its echocardiographic and microbiologic findings are often less specific than those of native endocarditis, its diagnosis now increasingly relies on alternative imaging modalities such as F-18-FDG PET-CT. Anti-infective and surgical treatment are made more difficult by biofilm formation on the prosthetic valve and the frequent formation of perivalvular abscesses.
CONCLUSION
Increased awareness of this clinical entity in the outpatient setting will promote the earlier initiation of appropriate diagnostic studies. Proper diagnostic evaluation is an essential prerequisite for the early detection and timely treatment of prosthetic endocarditis, with the goal of preventing progressive destruction and thus improving the outcome. Preventive and educative measures should be intensified, and certified, multidisciplinary endocarditis teams should be established. Antibiotic prophylaxis is now given much more restrictively than in earlier years; the risk of infection must be weighed against the potential development of both individual and collective resistance to antibiotic drugs.
Topics: Humans; Positron Emission Tomography Computed Tomography; Fluorodeoxyglucose F18; Heart Valve Prosthesis; Endocarditis; Heart, Artificial
PubMed: 37427994
DOI: 10.3238/arztebl.m2023.0104 -
BMJ Case Reports Aug 2019A 62-year-old man was admitted to the emergency department due to fever and acute heart failure. A transthoracic echocardiogram revealed severe aortic valve obstruction....
A 62-year-old man was admitted to the emergency department due to fever and acute heart failure. A transthoracic echocardiogram revealed severe aortic valve obstruction. He was an hepatic transplant recipient and was medicated with everolimus. He underwent mitral and aortic valve replacement with prosthetic valves 4 years ago. Due to his medical background, therapy and clinical presentation, empirical therapy for infective endocarditis was started. Transoesophageal echocardiogram showed severe aortic valve regurgitation but no other findings suggestive of endocarditis. Computed tomography (CT) revealed pulmonary infiltrates compatible with infection and no evidence of septic embolisation. Multiple sets of blood cultures were negative. was isolated in bronchial lavage and antibiotic therapy was adjusted. The patient underwent aortic valve replacement, with no macroscopic findings suggestive of endocarditis. was isolated in the surgically removed valve. Dual antibiotic therapy was successfully administered for 6 weeks.
Topics: Acute Disease; Anti-Bacterial Agents; Aortic Valve Insufficiency; Bronchoalveolar Lavage Fluid; Bronchoscopy; Diagnosis, Differential; Echocardiography, Transesophageal; Endocarditis, Bacterial; Heart Failure; Heart Valve Diseases; Heart Valve Prosthesis; Humans; Lung; Male; Middle Aged; Proteus mirabilis; Tomography, X-Ray Computed; Treatment Outcome
PubMed: 31466989
DOI: 10.1136/bcr-2019-230575 -
The Journal of Invasive Cardiology Jul 2022We present a novel method for the treatment of right-sided bioprosthetic valve endocarditis with AngioVac debulking followed by percutaneous pulmonic and tricuspid valve...
We present a novel method for the treatment of right-sided bioprosthetic valve endocarditis with AngioVac debulking followed by percutaneous pulmonic and tricuspid valve replacement for residual transcatheter valve degeneration and right ventricular dysfunction.
Topics: Bioprosthesis; Endocarditis; Heart Valve Prosthesis; Humans
PubMed: 35772932
DOI: No ID Found -
Journal of the American Heart... Feb 2021Bioprosthetic heart valves (BHVs) largely circumvent the need for long-term anticoagulation compared with mechanical valves but are increasingly susceptible to... (Review)
Review
Bioprosthetic heart valves (BHVs) largely circumvent the need for long-term anticoagulation compared with mechanical valves but are increasingly susceptible to deterioration and reduced durability with reoperation rates of ≈10% and 30% at 10 and 15 years, respectively. Structural valve degeneration is a common, unpreventable, and untreatable consequence of BHV implantation and is frequently characterized by leaflet calcification. However, 25% of BHV reoperations attributed to structural valve degeneration occur with minimal leaflet mineralization. This review discusses the noncalcific mechanisms of BHV structural valve degeneration, highlighting the putative roles and pathophysiological relationships between protein infiltration, glycation, oxidative and mechanical stress, and inflammation and the structural consequences for surgical and transcatheter BHVs.
Topics: Bioprosthesis; Calcinosis; Heart Valve Prosthesis; Humans; Prosthesis Design; Prosthesis Failure; Risk Factors; Stress, Mechanical
PubMed: 33494616
DOI: 10.1161/JAHA.120.018921 -
Current Cardiology Reviews 2022Paravalvular Leak (PVL) refers to the retrograde flow of blood in the space between an implanted cardiac valve and native tissue. These are unfortunately but luckily...
BACKGROUND
Paravalvular Leak (PVL) refers to the retrograde flow of blood in the space between an implanted cardiac valve and native tissue. These are unfortunately but luckily relatively uncommon complications of prosthetic valve replacement that, especially when moderate or severe, have important clinical consequences.
OBJECTIVE
Addressing PVL requires a multidisciplinary team to properly diagnose this process and choose the corrective option most likely to result in success.
METHODS
A comprehensive literature search was undertaken to formulate this narrative review.
RESULTS
This review highlights the complex nature of PVL and the promising contemporary treatments available.
CONCLUSION
Clinicians should be adept at recognizing PVL and characterizing it using multimodality imaging. Using the many available tools and a multidisciplinary approach should lead to favorable outcomes in patients with PVL.
Topics: Humans; Aortic Valve; Aortic Valve Insufficiency; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Retrospective Studies; Transcatheter Aortic Valve Replacement; Treatment Outcome
PubMed: 35546743
DOI: 10.2174/1573403X18666220511113310 -
Gaceta Medica de Mexico 2022Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients.
INTRODUCTION
Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients.
OBJECTIVE
To evaluate the safety and efficacy of the National Institute of Cardiology (INC) bioprosthetic heart valve in humans.
METHODS
Single-center study that included 341 patients who underwent single surgical aortic valve replacement with INC heart valve.
RESULTS
318 implants were performed de novo (93%) and 23 as redo surgery (7%); STS scores were 1.4 and 1.8%, and follow-up was for 42 and 46 months, respectively. There were no differences in clinical complications or pacemaker implantation rate. Both groups maintained a normal LVEF. Overall improvement in functional class was observed, with worsening only in two patients of the de novo group. INC prosthesis dysfunction requiring surgical reintervention was observed in eight patients (4.65%) of the de novo group vs. one patient in the redo group.
CONCLUSIONS
The INC heart valve is efficacious and safe, and is associated with a low rate of complications and functional class improvement during long-term follow-up. Prospective, comparative studies of this valve are required.
Topics: Humans; Heart Valve Prosthesis Implantation; Prospective Studies; Aortic Valve; Heart Valve Prosthesis; Prosthesis Failure; Cardiology; Treatment Outcome; Aortic Valve Stenosis; Reoperation
PubMed: 36657112
DOI: 10.24875/GMM.M22000715 -
Brazilian Journal of Cardiovascular... Mar 2022Modern bioprostheses offer a complete and definitive solution to elderly patients who need aortic valve surgery. Nonetheless, the scenario is more demanding when dealing...
Modern bioprostheses offer a complete and definitive solution to elderly patients who need aortic valve surgery. Nonetheless, the scenario is more demanding when dealing with younger and less fragile patients. In this setting, any prosthetic aortic valve replacement can provide only a suboptimal solution and its related issues have not been fixed yet. The answer to the needs of this special population is the enhancement and refinement of the surgical technique. The Ozaki technique relies on custom-tailored autologous aortic cusps individually sutured in the aortic position. This approach has been showing optimal results if performed after a dedicated training period.
Topics: Aged; Aortic Valve; Aortic Valve Stenosis; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Prosthesis Design; Treatment Outcome
PubMed: 34236811
DOI: 10.21470/1678-9741-2020-0476