Journal of Periodontology May 2019The aim of this systematic review and meta-analysis was to compare the clinical efficacy of the early dental implant placement protocol with immediate and delayed dental... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The aim of this systematic review and meta-analysis was to compare the clinical efficacy of the early dental implant placement protocol with immediate and delayed dental implant placement protocols.
METHODS
An electronic and manual search of literature was made to identify clinical studies comparing early implant placement with immediate or delayed placement. Data from the included studies were pooled and quantitative analyses were performed for the implant outcomes reported as the number of failed implants (primary outcome variable) and for changes in peri-implant marginal bone level, peri-implant probing depth, and peri-implant soft tissue level (secondary outcome variables).
RESULTS
Twelve studies met the inclusion criteria. Significant difference in risk of implant failure was found neither between the early and immediate placement protocols (risk difference = -0.018; 95% confidence interval [CI] = -0.06, 0.025; P = 0.416) nor between early and delayed placement protocols (risk difference = -0.008; 95% CI = -0.044, 0.028; P = 0.670). Pooled data of changes in peri-implant marginal bone level demonstrated significantly less marginal bone loss for implants placed using the early placement protocol compared with those placed in fresh extraction sockets (P = 0.001; weighted mean difference = -0.14 mm; 95% CI = -0.22, -0.05). No significant differences were found between the protocols for the other variables.
CONCLUSIONS
The available evidence supports the clinical efficacy of the early implant placement protocol. Present findings indicate that the early implant placement protocol results in implant outcomes similar to immediate and delayed placement protocols and a superior stability of peri-implant hard tissue compared with immediate implant placement.
Topics: Dental Implantation, Endosseous; Dental Implants; Dental Implants, Single-Tooth; Dental Prosthesis, Implant-Supported; Dental Restoration Failure; Immediate Dental Implant Loading; Tooth Extraction; Tooth Socket; Treatment Outcome
PubMed: 30395355
DOI: 10.1002/JPER.18-0338 -
Journal of Periodontology Jan 2021The peri-implant soft tissue phenotype (PSP) encompasses the keratinized mucosa width (KMW), mucosal thickness (MT), and supracrestal tissue height (STH). Numerous... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The peri-implant soft tissue phenotype (PSP) encompasses the keratinized mucosa width (KMW), mucosal thickness (MT), and supracrestal tissue height (STH). Numerous approaches to augment soft tissue volume around endosseous dental implants have been investigated. To what extent PSP modification is beneficial for peri-implant health has been subject of debate in the field of implant dentistry. The aim of this systematic review was to analyze the evidence regarding the efficacy of soft tissue augmentation procedures aimed at modifying the PSP and their impact on peri-implant health.
METHODS
A comprehensive search was performed to identify clinical studies that involved soft tissue augmentation around dental implants and reported findings on KMW, MT, and/or STH changes. The effect of the intervention on peri-implant health was also assessed. Selected articles were classified based on the general type of surgical approach to increase PSP, either bilaminar or an apically positioned flap (APF) technique. A network meta-analysis including only randomized-controlled trials (RCTs) reporting on PSP outcomes was conducted to assess and compare different techniques.
RESULTS
A total of 52 articles were included in the qualitative analysis, and 23 RCTs were included as part of the network meta-analysis. Sixteen RCTs reported the outcomes of PSP modification therapy with bilaminar techniques, whereas 7 involved the use of APF. The analysis showed that bilaminar techniques in combination with soft tissue grafts (connective tissue graft [CTG], collagen matrix [CM], and acellular dermal matrix [ADM]) resulted in a significant increase in MT compared to non-augmented sites. In particular, CTG and ADM were associated with higher MT gain as compared to CM and non-augmented sites. However, no significant differences in KMW were observed across different bilaminar techniques. PSP modification via a bilaminar approach utilizing either CTG or CM showed beneficial effects on marginal bone level stability. APF-based approaches in combination with free gingival graft (FGG), CTG, CM, or ADM showed a significant KMW gain compared to non-augmented sites. However, compared to APF alone, only FGG exhibited a significantly higher KMW gain. APF with any evaluated soft tissue graft was associated with with reduction of probing depth, soft tissue dehiscence and plaque index compared to non-augmented sites compared to non-augmented sites. The evidence regarding the effect of PSP modification via APF-based approaches on peri-implant marginal bone loss or preservation is inconclusive.
CONCLUSIONS
Bilaminar approach involving CTG or ADM obtained the highest amount of MT gain, whereas APF in combination with FGG was the most effective technique for increasing KMW. KMW augmentation via APF was associated with a significant reduction in probing depth, soft tissue dehiscence and plaque index, regardless of the soft tissue grafting material employed, whereas bilaminar techniques with CTG or CM showed beneficial effects on marginal bone level stability.
Topics: Connective Tissue; Dental Implants; Gingiva; Network Meta-Analysis; Phenotype
PubMed: 32710810
DOI: 10.1002/JPER.19-0716 -
International Journal of Implant... Jan 2022Dental implant surgery was developed to be the most suitable and comfortable instrument for dental and oral rehabilitation in the past decades, but with increasing... (Review)
Review
PURPOSE
Dental implant surgery was developed to be the most suitable and comfortable instrument for dental and oral rehabilitation in the past decades, but with increasing numbers of inserted implants, complications are becoming more common. Diabetes mellitus as well as prediabetic conditions represent a common and increasing health problem (International Diabetes Federation in IDF Diabetes Atlas, International Diabetes Federation, Brussels, 2019) with extensive harmful effects on the entire organism [(Abiko and Selimovic in Bosnian J Basic Med Sci 10:186-191, 2010), (Khader et al., in J Diabetes Complicat 20:59-68, 2006, https://doi.org/10.1016/j.jdiacomp.2005.05.006 )]. Hence, this study aimed to give an update on current literature on effects of prediabetes and diabetes mellitus on dental implant success.
METHODS
A systematic literature research based on the PRISMA statement was conducted to answer the PICO question "Do diabetic patients with dental implants have a higher complication rate in comparison to healthy controls?". We included 40 clinical studies and 16 publications of aggregated literature in this systematic review.
RESULTS
We conclude that patients with poorly controlled diabetes mellitus suffer more often from peri-implantitis, especially in the post-implantation time. Moreover, these patients show higher implant loss rates than healthy individuals in long term. Whereas, under controlled conditions success rates are similar. Perioperative anti-infective therapy, such as the supportive administration of antibiotics and chlorhexidine, is the standard nowadays as it seems to improve implant success. Only few studies regarding dental implants in patients with prediabetic conditions are available, indicating a possible negative effect on developing peri-implant diseases but no influence on implant survival.
CONCLUSION
Dental implant procedures represent a safe way of oral rehabilitation in patients with prediabetes or diabetes mellitus, as long as appropriate precautions can be adhered to. Accordingly, under controlled conditions there is still no contraindication for dental implant surgery in patients with diabetes mellitus or prediabetic conditions.
Topics: Chlorhexidine; Dental Implants; Diabetes Mellitus; Humans; Peri-Implantitis; Prediabetic State
PubMed: 34978649
DOI: 10.1186/s40729-021-00399-8 -
Acta Odontologica Scandinavica Jan 2021The aim of this study was to explore the possible association between diabetes mellitus and dental implant complications. (Meta-Analysis)
Meta-Analysis
OBJECTIVES
The aim of this study was to explore the possible association between diabetes mellitus and dental implant complications.
MATERIAL AND METHODS
A systematic literature review was conducted to answer the following PICO (Participants, Intervention, Comparison, and Outcome) question: Is there association between diabetes mellitus and dental implant complications? Two independent searchers performed a literature search of the PubMed/MEDLINE, Web of Science, Cochrane Library and EMBASE databases for studies published until February 2020, focussing on studies including continuous outcomes, marginal bone loss (primary outcome), probing depth, and bleeding upon probing (secondary outcomes).
RESULTS AND CONCLUSIONS
A final total of 10 published studies were included in this systematic review. There were statistically significant differences between the groups with regard to marginal bone loss ( < .00001), probing depth ( < .00001) and bleeding around dental implants ( < .00001), and subjects without diabetes had lower complication rates. Additionally, in the subgroup analysis performed with loading time and HbA1c levels, a more evident association was found in immediate loading for probing depth. Moreover, the analysis results of bleeding around dental implants suggested that as HbA1c level increases, the bleeding of the tissues surrounding the implant will also increase. With regard to dental implant complications, there were statistically significant differences favouring patients without diabetes mellitus.
Topics: Alveolar Bone Loss; Dental Implantation, Endosseous; Dental Implants; Dental Restoration Failure; Diabetes Mellitus; Humans; Immediate Dental Implant Loading
PubMed: 32401121
DOI: 10.1080/00016357.2020.1761031 -
Journal of Medical Internet Research Jan 2023The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently developed AR-assisted dental implant navigation system (AR navigation), which uses innovative image technology to directly visualize and track a presurgical plan over an actual surgical site, has attracted great interest.
OBJECTIVE
This study is the first systematic review and meta-analysis study that aimed to assess the accuracy of dental implants placed by AR navigation and compare it with that of the widely used implant placement methods, including the freehand method (FH), template-based static guidance (TG), and conventional navigation (CN).
METHODS
Individual search strategies were used in PubMed (MEDLINE), Scopus, ScienceDirect, Cochrane Library, and Google Scholar to search for articles published until March 21, 2022. This study was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered in the International Prospective Register of Systematic Reviews (PROSPERO) database. Peer-reviewed journal articles evaluating the positional deviations of dental implants placed using AR-assisted implant navigation systems were included. Cohen d statistical power analysis was used to investigate the effect size estimate and CIs of standardized mean differences (SMDs) between data sets.
RESULTS
Among the 425 articles retrieved, 15 articles were considered eligible for narrative review, 8 articles were considered for single-arm meta-analysis, and 4 were included in a 2-arm meta-analysis. The mean lateral, global, depth, and angular deviations of the dental implant placed using AR navigation were 0.90 (95% CI 0.78-1.02) mm, 1.18 (95% CI 0.95-1.41) mm, 0.78 (95% CI 0.48-1.08) mm, and 3.96° (95% CI 3.45°-4.48°), respectively. The accuracy of AR navigation was significantly higher than that of the FH method (SMD=-1.01; 95% CI -1.47 to -0.55; P<.001) and CN method (SMD=-0.46; 95% CI -0.64 to -0.29; P<.001). However, the accuracies of the AR navigation and TG methods were similar (SMD=0.06; 95% CI -0.62 to 0.74; P=.73).
CONCLUSIONS
The positional deviations of AR-navigated implant placements were within the safety zone, suggesting clinically acceptable accuracy of the AR navigation method. Moreover, the accuracy of AR implant navigation was comparable with that of the highly recommended dental implant-guided surgery method, TG, and superior to that of the conventional FH and CN methods. This review highlights the possibility of using AR navigation as an effective and accurate immersive surgical guide for dental implant placement.
Topics: Humans; Augmented Reality; Dental Implants; Surgery, Computer-Assisted; Surgeons; Technology
PubMed: 36598798
DOI: 10.2196/42040 -
Medicina (Kaunas, Lithuania) Dec 2021: Tobacco is today the single most preventable cause of death, being associated with countless diseases, including cancer and neurological, cardiovascular, and... (Meta-Analysis)
Meta-Analysis Review
: Tobacco is today the single most preventable cause of death, being associated with countless diseases, including cancer and neurological, cardiovascular, and respiratory diseases. Smoking also brings negative consequences to oral health, potentially impairing treatment with dental implants. The present review aimed to evaluate the influence of smoking on dental implant failure rates and marginal bone loss (MBL). : Electronic search was undertaken in three databases, plus a manual search of journals. Meta-analyses were performed, in addition to meta-regressions, in order to verify how the odds ratio (OR) and MBL were associated with follow-up time. : The review included 292 publications. Altogether, there were 35,511 and 114,597 implants placed in smokers and in non-smokers, respectively. Pairwise meta-analysis showed that implants in smokers had a higher failure risk in comparison with non-smokers (OR 2.402, < 0.001). The difference in implant failure between the groups was statistically significant in the maxilla (OR 2.910, < 0.001), as well as in the mandible (OR 2.866, < 0.001). The MBL mean difference (MD) between the groups was 0.580 mm ( < 0.001). There was an estimated decrease of 0.001 in OR ( = 0.566) and increase of 0.004 mm ( = 0.279) in the MBL MD between groups for every additional month of follow-up, although without statistical significance. Therefore, there was no clear influence of the follow-up on the effect size (OR) and on MBL MD between groups. : Implants placed in smokers present a 140.2% higher risk of failure than implants placed in non-smokers.
Topics: Dental Implants; Humans; Mandible; Maxilla; Smokers; Smoking
PubMed: 35056347
DOI: 10.3390/medicina58010039 -
Journal of Dentistry May 2019To identify and appraise the most recent studies reporting dental implant survival in adults (≥18 years) using contemporary implant systems (solid screw, roughened... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
To identify and appraise the most recent studies reporting dental implant survival in adults (≥18 years) using contemporary implant systems (solid screw, roughened surface) for a period of 10 years; and explore new predictors of implant survival.
SOURCE
MEDLINE, Scopus, and the Cochrane Central Register of Controlled trials were searched from 1997 to January 2018 to focus on contemporary implant systems.
STUDY SELECTION
Only prospective observational studies with at least 10 participants and 35 implants were included. The unit of study was the 'absolute survival' rate of dental implants after 10 years in the oral cavity. Study quality was assessed utilising a modified Hoy risk of bias tool for prevalence studies. A sensitivity meta-analysis was undertaken utilising a plausibly imputed model for missing data.
DATA
18 studies met the inclusion criteria. The summary estimate for 10-year survival at the implant level was 96.4% (95% CI 95.2%-97.5%) and the prediction interval was 91.5%-99.4%. The sensitivity meta-analysis summary estimate of survival was 93.2% (95% CI 90.1% to 95.8%)p = 0.041 with a prediction interval of 76.6%-100%. Older age (≥ 65 years) was a significant predictor at 91.5%, p = 0.038 in the sensitivity meta-analysis.
CONCLUSIONS
A traditional analysis produced similar 10-year survival estimates to previous systematic reviews. A more realistic sensitivity meta-analysis accounting for loss to follow-up data and the calculation of prediction intervals demonstrated a possible doubling of the risk of implant loss in the older age groups.
CLINICAL SIGNIFICANCE
Improved analysis provides the clinician with better estimation of the real-world risk of implant failures so helping the clinician communicate the potential risk to patients.
Topics: Adult; Aged; Dental Implantation, Endosseous; Dental Implants; Dental Restoration Failure; Humans; Prospective Studies
PubMed: 30904559
DOI: 10.1016/j.jdent.2019.03.008 -
Periodontology 2000 Feb 2023Flapless and fully guided implant placement has the potential to maximize efficacy outcomes and at the same time to minimize surgical invasiveness. The aim of the... (Meta-Analysis)
Meta-Analysis Review
Flapless and fully guided implant placement has the potential to maximize efficacy outcomes and at the same time to minimize surgical invasiveness. The aim of the current systematic review was to answer the following PICO question: "In adult human subjects undergoing dental implant placement (P), is minimally invasive flapless computer-aided fully guided (either dynamic or static computer-aided implant placement (sCAIP)) (I) superior to flapped conventional (free-handed implant placement (FHIP) or cast-based/drill partially guided implant placement (dPGIP)) surgery (C), in terms of efficacy, patient morbidity, long-term prognosis, and costs (O)?" Randomized clinical trials (RCTs) fulfilling specific inclusion criteria established to answer the PICO question were included. Two review authors independently searched for eligible studies, screened the titles and abstracts, performed full-text analysis, extracted the data from the published reports, and performed the risk of bias assessment. In cases of disagreement, a third review author took the final decision during ad hoc consensus meetings. The study results were summarized using random effects meta-analyses, which were based (wherever possible) on individual patient data (IPD). A total of 10 manuscripts reporting on five RCTs, involving a total of 124 participants and 449 implants, and comparing flapless sCAIP with flapped FHIP/cast-based partially guided implant placement (cPGIP), were included. There was no RCT analyzing flapless dynamic computer-aided implant placement (dCAIP) or flapped dPGIP. Intergroup meta-analyses indicated less depth deviation (difference in means (MD) = -0.28 mm; 95% confidence interval (CI): -0.59 to 0.03; moderate certainty), angular deviation (MD = -3.88 degrees; 95% CI: -7.00 to -0.77; high certainty), coronal (MD = -0.6 mm; 95% CI: -1.21 to 0.01; low certainty) and apical (MD = -0.75 mm; 95% CI: -1.43 to -0.07; moderate certainty) three-dimensional bodily deviations, postoperative pain (MD = -17.09 mm on the visual analogue scale (VAS); 95% CI: -33.38 to -0.80; low certainty), postoperative swelling (MD = -6.59 mm on the VAS; 95% CI: -19.03 to 5.85; very low certainty), intraoperative discomfort (MD = -9.36 mm on the VAS; 95% CI: -17.10 to -1.61) and surgery duration (MD = -24.28 minutes; 95% CI: -28.62 to -19.95) in flapless sCAIP than in flapped FHIP/cPGIP. Despite being more accurate than flapped FHIP/cPGIP, flapless sCAIP still resulted in deviations with respect to the planned position (intragroup meta-analytic means: 0.76 mm in depth, 2.57 degrees in angular, 1.43 mm in coronal, and 1.68 in apical three-dimensional bodily position). Moreover, flapless sCAIP presented a 12% group-specific intraoperative complication rate, resulting in an inability to place the implant with this protocol in 7% of cases. Evidence regarding more clinically relevant outcomes of efficacy (implant survival and success, prosthetically and biologically correct positioning), long-term prognosis, and costs, is currently scarce. When the objective is to guarantee minimal invasiveness at implant placement, clinicians could consider the use of flapless sCAIP. A proper case selection and consideration of a safety margin are, however, suggested.
Topics: Adult; Humans; Dental Implants; Dental Implantation, Endosseous; Surgery, Computer-Assisted; Surgical Flaps
PubMed: 35906928
DOI: 10.1111/prd.12440 -
Journal of Prosthodontic Research Jan 2022Dental implant therapy is a common clinical treatment for missing teeth. However, the esthetic result is not as satisfactory as expected in some cases, especially in the...
PURPOSE
Dental implant therapy is a common clinical treatment for missing teeth. However, the esthetic result is not as satisfactory as expected in some cases, especially in the anterior maxillary area. Poor esthetic results are caused by inadequate preparation of the hard and soft tissues in this area before treatment. The socket shield technique may be an alternative for a desirable esthetic outcome in dental implant treatments.
STUDY SELECTION
In the present systematic review, PubMed-Medline, Google Scholar, and ScienceDirect were searched for clinical studies published from January 2000 to December 2018.
RESULTS
Twenty studies were included, comprising one randomized controlled trial, two cohort studies, 14 clinical human case reports, and three retrospective case series. In total, 288 patients treated with the socket shield technique with immediate implant placement and follow-up between 3-60 months after placement were included. A quality assessment showed that 12 of the 20 included studies were of good quality. Twenty-six of the 274 (9.5%) cases developed complications or adverse effects related to the socket shield technique. Most studies reported implant survival without the complications (90.5%); most of the cases that were followed up for more than 12 months after implant placement achieved a good esthetic appearance. The failure rate was low without the complications, although there were some failures due to failed implant osseointegration, socket shield mobility and infection, socket shield exposure, socket shield migration, and apical root resorption.
CONCLUSIONS
The socket shield technique can be used in dental implant treatment, but it remains difficult to predict the long-term success of this technique until high-quality evidence becomes available.
Topics: Dental Implantation, Endosseous; Dental Implants; Dental Implants, Single-Tooth; Esthetics, Dental; Humans; Immediate Dental Implant Loading; Retrospective Studies; Tooth Extraction; Tooth Socket; Treatment Outcome
PubMed: 33692284
DOI: 10.2186/jpr.JPR_D_20_00054 -
BMC Oral Health Jul 2022Implantology represents the gold standard for oral rehabilitation, unfortunately, often, despite there are no local contraindications to this type of rehabilitation,...
OBJECTIVE
Implantology represents the gold standard for oral rehabilitation, unfortunately, often, despite there are no local contraindications to this type of rehabilitation, there are uncertainties regarding the general health of our patients. Many patients nowadays take bisphosphonate drugs, often without first seeking advice from an oral surgeon or a dentist. The purpose of this review is precisely to highlight any contraindications to this type of treatment reported in the literature, in patients who take or have taken bisphosphonate drugs.
METHODS
For this study the scientific information sources were consulted using as search terms "("bisphosphonate AND "dental implant")", obtaining 312 results, these were subsequently skimmed according to the inclusion and exclusion criteria, and further evaluated their relevance to the study and the presence of requested outcomes.
RESULTS
Only 9 manuscripts (RCTs, Multicentric studies and Clinical Trials) were included in this review, as they respected the parameters of this review, they were analyzed and it was possible to draw important results from them. Surely from this study it is understood that the use of bisphosphonate drugs does not represent an absolute contraindication to implant therapy, it is evident how adequate pharmacological prophylaxis, and an adequate protocol reduce the risks regarding implant failures. Furthermore, the values of marginal bone loss over time seem, even if not statistically significant, to be better in implant rehabilitation with bisphosphonate drugs association. Only a few molecules like risedronate, or corticosteroids, or some conditions like smoking or diabetes have shown a high risk of surgical failure.
CONCLUSION
Although this study considered different studies for a total of 378 patients and at least 1687 different dental implants, showing better results in some cases for dental implant therapy in cases of bisphosphonate intake, further clinical, randomized and multicentric studies are needed, with longer follow-ups, to fully clarify this situation which often negatively affects the quality of life of our patients and places clinicians in the face of doubts.
Topics: Dental Implantation, Endosseous; Dental Implants; Dental Restoration Failure; Diphosphonates; Humans; Quality of Life
PubMed: 35843929
DOI: 10.1186/s12903-022-02330-y