Clinical Microbiology and Infection :... May 2020Central venous catheters are used extensively as temporary or permanent vascular access for haemodialysis patients. Catheter-related bloodstream infections are the main... (Comparative Study)
Comparative Study
Comparative efficacy and safety of lock solutions for the prevention of catheter-related complications including infectious and bleeding events in adult haemodialysis patients: a systematic review and network meta-analysis.
BACKGROUND
Central venous catheters are used extensively as temporary or permanent vascular access for haemodialysis patients. Catheter-related bloodstream infections are the main complication of central venous catheters and increase morbidity and mortality in haemodialysis patients.
OBJECTIVES
The aim was to assess the most appropriate lock solution for central venous catheters to prevent catheter-related bloodstream infections and other complications.
DATA SOURCES
Medline, Embase and the Cochrane Central Register of Controlled Trials from the date of their inception to August 2018 were used as data sources. The reference lists of eligible studies and relevant reviews were also checked.
STUDY ELIGIBILITY CRITERIA AND PARTICIPANTS
Randomized controlled trials (RCTs) comparing different lock solutions for the prevention of central venous catheter-related infectious and bleeding complications for adult dialysis patients were included.
INTERVENTIONS
Interventions were lock solutions for haemodialysis catheters.
METHODS
The primary outcomes were catheter-related bloodstream infections and bleeding events. The secondary outcomes were catheter malfunction, exit-site infection, and all-cause mortality. We estimated summary risk ratios (RRs) using pairwise and network meta-analysis. We assessed the risk of bias of individual studies with the Cochrane risk of bias tool.
RESULTS
Forty-nine trials (7020 patients) were included for this study. Compared with heparin 5000 U/mL, antibiotic locks (antibiotics with trisodium citrate (TSC), ethylenediamine tetraacetic acid (EDTA), heparin 5000 U/mL, low-dose heparin or urokinase) and ethanol locks were more effective in preventing catheter-related bloodstream infections. Antimicrobial agents plus low-dose heparin (500-2500 U/mL), TSC and low-dose heparin locks had lower risk of bleeding events than heparin 5000 U/mL. None of the lock solutions reduced rates of catheter malfunction and all-cause mortality compared with heparin 5000 U/mL. In summary, antibiotics plus low-dose heparin was ranked as the best lock solution. The overall results were not materially changed in sensitivity analyses.
CONCLUSIONS
Taking into account both efficacy and safety, antibiotics plus low-dose heparin (500-2500 U/mL) may be the preferred lock solution.
Topics: Adult; Anti-Infective Agents; Anticoagulants; Bacteremia; Catheter-Related Infections; Central Venous Catheters; Hemorrhage; Humans; Network Meta-Analysis; Renal Dialysis; Safety; Treatment Outcome
PubMed: 31857208
DOI: 10.1016/j.cmi.2019.12.003 -
Kidney & Blood Pressure Research 2020The etiology of acute metabolic acidosis (aMA) is heterogeneous, and the consequences are potentially life-threatening. The aim of this article was to summarize the...
BACKGROUND
The etiology of acute metabolic acidosis (aMA) is heterogeneous, and the consequences are potentially life-threatening. The aim of this article was to summarize the causes and management of aMA from a clinician's perspective.
SUMMARY
We performed a systematic search on PubMed, applying the following search terms: "acute metabolic acidosis," "lactic acidosis," "metformin" AND "acidosis," "unbalanced solutions" AND "acidosis," "bicarbonate" AND "acidosis" AND "outcome," "acute metabolic acidosis" AND "management," and "acute metabolic acidosis" AND "renal replacement therapy (RRT)/dialysis." The literature search did not consider diabetic ketoacidosis at all. Lactic acidosis evolves from various conditions, either with or without systemic hypoxia. The incidence of metformin-associated aMA is actually quite low. Unbalanced electrolyte preparations can induce hyperchloremic aMA. The latter potentially worsens kidney-related outcome parameters. Nevertheless, prospective and controlled data are missing at the moment. Recently, bicarbonate has been shown to improve clinically relevant endpoints in the critically ill, even if higher pH values (>7.3) are targeted. New therapeutics for aMA control are under development, since bicarbonate treatment can induce serious side effects. Key Messages: aMA is a frequent and potentially life-threatening complication of various conditions. Lactic acidosis might occur even in the absence of systemic hypoxia. The incidence of metformin-associated aMA is comparably low. Unbalanced electrolyte solutions induce hyperchloremic aMA, which most likely worsens the renal prognosis of critically ill patients. Bicarbonate, although potentially deleterious due to increased carbon dioxide production with subsequent intracellular acidosis, improves kidney-related endpoints in the critically ill.
Topics: Acidosis; Acidosis, Lactic; Acute Disease; Animals; Bicarbonates; Disease Management; Electrolytes; Humans; Hypoglycemic Agents; Metformin
PubMed: 32663831
DOI: 10.1159/000507813 -
The Cochrane Database of Systematic... Apr 2022Patients with kidney failure require vascular access to receive maintenance haemodialysis (HD), which can be achieved by an arteriovenous fistula or a central venous... (Review)
Review
BACKGROUND
Patients with kidney failure require vascular access to receive maintenance haemodialysis (HD), which can be achieved by an arteriovenous fistula or a central venous catheter (CVC). CVC use is related to frequent complications such as venous stenosis and infection. Venous stenosis occurs mainly due to trauma caused by the entrance of the catheter into the venous lumen and repeated contact with the vein wall. A biofilm, a colony of irreversible adherent and self-sufficient micro-organisms embedded in a self-produced matrix of exopolysaccharides, is associated with the development of infections in patients with indwelling catheters. Despite its clinical relevance, the treatment of catheter-related bloodstream infections (CRBSIs) in patients receiving maintenance HD remains controversial, especially regarding catheter management. Antibiotic lock solutions may sterilise the catheter, treat the infection and prevent unnecessary catheter procedures. However, such treatment may also lead to antibiotic resistance or even clinical worsening in certain more virulent pathogens. Catheter removal and delayed replacement may remove the source of infection, improving infectious outcomes, but this approach may also increase vascular access stenosis, thrombosis or both, or even central vein access failure. Catheter guidewire exchange attempts to remove the source of infection while maintaining access to the same vein and, therefore, may improve clinical outcomes and preserve central veins for future access.
OBJECTIVES
To assess the benefits and harms of different interventions for CRBSI treatment in patients receiving maintenance HD through a permanent CVC, such as systemic antibiotics alone or systemic antibiotics combined with either lock solutions or catheter guidewire exchange or catheter replacement.
SEARCH METHODS
We searched the Cochrane Kidney and Transplant Register of Studies up to 21 December 2021 through contact with the Information Specialist using search terms relevant to this review. Studies in the Register were identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Register (ICTRP) Search Portal, and ClinicalTrials.gov.
SELECTION CRITERIA
We included all randomised controlled trials (RCTs) and quasi-RCTs evaluating the management of CRBSI in permanent CVCs in people receiving maintenance HD.
DATA COLLECTION AND ANALYSIS
Two authors independently selected studies for inclusion, assessed their risk of bias, and performed data extraction. Results were expressed as risk ratios (RR) or hazard ratios (HR) for dichotomous outcomes and mean difference (MD) for continuous outcomes, with their 95% confidence intervals (CI). The certainty of the evidence was assessed using GRADE.
MAIN RESULTS
We identified two RCTs and one quasi-RCT that enrolled 760 participants addressing the treatment of CRBSIs in people (children and adults) receiving maintenance HD through CVC. No two studies compared the same interventions. The quasi-RCT compared two different lock solutions (tissue plasminogen activator (TPA) and heparin) with concurrent systemic antibiotics. One RCT compared systemic antibiotics alone and in association with an ethanol lock solution, and the other compared systemic antibiotics with different catheter management strategies (guidewire exchange versus removal and replacement). The overall certainty of the evidence was downgraded due to the small number of participants, high risk of bias in many domains, especially randomisation, allocation, and other sources of bias, and missing outcome data. It is uncertain whether an ethanol lock solution used with concurrent systemic antibiotics improved CRBSI eradication compared to systemic antibiotics alone (RR 1.61, 95% CI 1.16 to 2.23) because the certainty of this evidence is very low. There were no reported differences between the effects of TPA and heparin lock solutions on cure rates (RR 0.92, 95% CI 0.74 to 1.15) or between catheter guidewire exchange versus catheter removal with delayed replacement, expressed as catheter infection-free survival (HR 0.88, 95% CI 0.43 to 1.79). To date, no results are available comparing other interventions. Outcomes such as venous stenosis and/or thrombosis, antibiotic resistance, death, and adverse events were not reported.
AUTHORS' CONCLUSIONS
Currently, there is no available high certainty evidence to support one treatment over another for CRBSIs. The benefit of using ethanol lock treatment in combination with systemic antibiotics compared to systemic antibiotics alone for CRBSIs in patients receiving maintenance HD remains uncertain due to the very low certainty of the evidence. Hence, further RCTs to identify the benefits and harms of CRBSI treatment options are needed. Future studies should unify CRBSI and cure definitions and improve methodological design.
Topics: Adult; Catheter-Related Infections; Central Venous Catheters; Child; Heparin; Humans; Renal Dialysis; Sepsis
PubMed: 35363884
DOI: 10.1002/14651858.CD013554.pub2 -
Journal of Nephrology Sep 2023This systematic review summarises the stability of less commonly prescribed antibiotics in different peritoneal dialysis solutions that could be used for... (Review)
Review
BACKGROUND
This systematic review summarises the stability of less commonly prescribed antibiotics in different peritoneal dialysis solutions that could be used for culture-directed therapy of peritonitis, which would be especially useful in regions with a high prevalence of multidrug antibiotic-resistant strains.
METHODS
A literature search of Medline, Scopus, Embase and Google Scholar for articles published from inception to 25 January, 2023 was conducted. Only antibiotic stability studies conducted in vitro and not recently reviewed by So et al. were included. The main outcomes were chemical, physical, antimicrobial and microbial stability. This protocol was registered in PROSPERO (registration number CRD42023393366).
RESULTS
We screened 1254 abstracts, and 28 articles were included in the study. In addition to those discussed in a recent systematic review (So et al., Clin Kidney J 15(6):1071-1078, 2022), we identified 18 antimicrobial agents. Of these, 9 have intraperitoneal dosing recommendations in the recent International Society for Peritoneal Dialysis (ISPD) peritonitis guidelines, and 7 of the 9 had stability data applicable to clinical practice. They were cefotaxime, ceftriaxone, daptomycin, ofloxacin, and teicoplanin in glucose-based solutions, tobramycin in Extraneal solution only and fosfomycin in Extraneal, Nutrineal, Physioneal 1.36% and 2.27% glucose solutions.
CONCLUSIONS
Physicochemical stability has not been demonstrated for all antibiotics with intraperitoneal dosing recommendations in the ISPD peritonitis guidelines. Further studies are required to determine the stability of antibiotics, especially in icodextrin-based and low-glucose degradation products, pH-neutral solutions.
Topics: Humans; Anti-Bacterial Agents; Dialysis Solutions; Glucose; Icodextrin; Peritoneal Dialysis; Peritonitis
PubMed: 37548827
DOI: 10.1007/s40620-023-01716-7 -
The Cochrane Database of Systematic... Oct 2018Biocompatible peritoneal dialysis (PD) solutions, including neutral pH, low glucose degradation product (GDP) solutions and icodextrin, have previously been shown to... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Biocompatible peritoneal dialysis (PD) solutions, including neutral pH, low glucose degradation product (GDP) solutions and icodextrin, have previously been shown to favourably influence some patient-level outcomes, albeit based on generally sub-optimal quality studies. Several additional randomised controlled trials (RCT) evaluating biocompatible solutions in PD patients have been published recently. This is an update of a review first published in 2014.
OBJECTIVES
This review aimed to look at the benefits and harms of biocompatible PD solutions in comparison to standard PD solutions in patients receiving PD.
SEARCH METHODS
The Cochrane Kidney and Transplant Specialised Register was searched up to 12 February 2018 through contact with the Information Specialist using search terms relevant to this review. Studies in the Specialised Register are identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Register Search Portal and ClinicalTrials.gov.
SELECTION CRITERIA
All RCTs and quasi-RCTs in adults and children comparing the effects of biocompatible PD solutions (neutral pH, lactate-buffered, low GDP; neutral pH, bicarbonate(± lactate)-buffered, low GDP; glucose polymer (icodextrin)) in PD were included. Studies of amino acid-based solutions were excluded.
DATA COLLECTION AND ANALYSIS
Two authors extracted data on study quality and outcomes. Summary effect estimates were obtained using a random-effects model, and results were expressed as risk ratios and 95% confidence intervals (CI) for categorical variables, and mean differences (MD) or standardised mean differences (SMD) and 95% CI for continuous variables.
MAIN RESULTS
This review update included 42 eligible studies (3262 participants), including six new studies (543 participants). Overall, 29 studies (1971 participants) compared neutral pH, low GDP PD solution with conventional PD solution, and 13 studies (1291 participants) compared icodextrin with conventional PD solution. Risk of bias was assessed as high for sequence generation in three studies, allocation concealment in three studies, attrition bias in 21 studies, and selective outcome reporting bias in 16 studies.Neutral pH, low GDP versus conventional glucose PD solutionUse of neutral pH, low GDP PD solutions improved residual renal function (RRF) preservation (15 studies, 835 participants: SMD 0.19, 95% CI 0.05 to 0.33; high certainty evidence). This approximated to a mean difference in glomerular filtration rate of 0.54 mL/min/1.73 m (95% CI 0.14 to 0.93). Better preservation of RRF was evident at all follow-up durations with progressively greater preservation observed with increasing follow up duration. Neutral pH, low GDP PD solution use also improved residual urine volume preservation (11 studies, 791 participants: MD 114.37 mL/day, 95% CI 47.09 to 181.65; high certainty evidence). In low certainty evidence, neutral pH, low GDP solutions may make little or no difference to 4-hour peritoneal ultrafiltration (9 studies, 414 participants: SMD -0.42, 95% CI -0.74 to -0.10) which approximated to a mean difference in peritoneal ultrafiltration of 69.72 mL (16.60 to 122.00 mL) lower, and may increase dialysate:plasma creatinine ratio (10 studies, 746 participants: MD 0.01, 95% CI 0.00 to 0.03), technique failure or death compared with conventional PD solutions. It is uncertain whether neutral pH, low GDP PD solution use led to any differences in peritonitis occurrence, hospitalisation, adverse events (6 studies, 519 participants) or inflow pain (1 study, 58 participants: RR 0.51, 95% CI 0.24 to 1.08).Glucose polymer (icodextrin) versus conventional glucose PD solutionIn moderate certainty evidence, icodextrin probably reduced episodes of uncontrolled fluid overload (2 studies, 100 participants: RR 0.30, 95% CI 0.15 to 0.59) and augmented peritoneal ultrafiltration (4 studies, 102 participants: MD 448.54 mL/d, 95% CI 289.28 to 607.80) without compromising RRF (4 studies, 114 participants: SMD 0.12, 95% CI -0.26 to 0.49; low certainty evidence) which approximated to a mean creatinine clearance of 0.30 mL/min/1.73m higher (0.65 lower to 1.23 higher) or urine output (3 studies, 69 participants: MD -88.88 mL/d, 95% CI -356.88 to 179.12; low certainty evidence). It is uncertain whether icodextrin use led to any differences in adverse events (5 studies, 816 participants) technique failure or death.
AUTHORS' CONCLUSIONS
This updated review strengthens evidence that neutral pH, low GDP PD solution improves RRF and urine volume preservation with high certainty. These effects may be related to increased peritoneal solute transport and reduced peritoneal ultrafiltration, although the evidence for these outcomes is of low certainty due to significant heterogeneity and suboptimal methodological quality. Icodextrin prescription increased peritoneal ultrafiltration and mitigated uncontrolled fluid overload with moderate certainty. The effects of either neutral pH, low GDP solution or icodextrin on peritonitis, technique survival and patient survival remain uncertain and require further high quality, adequately powered RCTs.
Topics: Adult; Bicarbonates; Child; Dialysis Solutions; Glucose; Humans; Hydrogen-Ion Concentration; Icodextrin; Kidney; Peritoneal Dialysis; Peritoneum; Pharmaceutical Solutions; Randomized Controlled Trials as Topic; Urine
PubMed: 30362116
DOI: 10.1002/14651858.CD007554.pub3 -
Clinical Journal of the American... Aug 2015Neutral-pH, low-glucose degradation products solutions were developed in an attempt to lessen the adverse effects of conventional peritoneal dialysis solutions. A... (Meta-Analysis)
Meta-Analysis Review
Effect of Neutral-pH, Low-Glucose Degradation Product Peritoneal Dialysis Solutions on Residual Renal Function, Urine Volume, and Ultrafiltration: A Systematic Review and Meta-Analysis.
BACKGROUND AND OBJECTIVES
Neutral-pH, low-glucose degradation products solutions were developed in an attempt to lessen the adverse effects of conventional peritoneal dialysis solutions. A systematic review was performed evaluating the effect of these solutions on residual renal function, urine volume, peritoneal ultrafiltration, and peritoneal small-solute transport (dialysate to plasma creatinine ratio) over time.
DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS
Multiple electronic databases were searched from January of 1995 to January of 2013. Randomized trials reporting on any of four prespecified outcomes were selected by consensus among multiple reviewers.
RESULTS
Eleven trials of 643 patients were included. Trials were generally of poor quality. The meta-analysis was performed using a random effects model. The use of neutral-pH, low-glucose degradation products solutions resulted in better preserved residual renal function at various study durations, including >1 year (combined analysis: 11 studies; 643 patients; standardized mean difference =0.17 ml/min; 95% confidence interval, 0.01 to 0.32), and greater urine volumes (eight studies; 598 patients; mean difference =128 ml/d; 95% confidence interval, 58 to 198). There was no significant difference in peritoneal ultrafiltration (seven studies; 571 patients; mean difference =-110; 95% confidence interval, -312 to 91) or dialysate to plasma creatinine ratio (six studies; 432 patients; mean difference =0.03; 95% confidence interval, 0.00 to 0.06).
CONCLUSIONS
The use of neutral-pH, low-glucose degradation products solutions results in better preservation of residual renal function and greater urine volumes. The effect on residual renal function occurred early and persisted beyond 12 months. Additional studies are required to evaluate the use of neutral-pH, low-glucose degradation products solutions on hard clinical outcomes.
Topics: Biomarkers; Chi-Square Distribution; Creatinine; Dialysis Solutions; Glucose; Humans; Hydrogen-Ion Concentration; Kidney; Kidney Diseases; Peritoneal Dialysis; Randomized Controlled Trials as Topic; Risk Factors; Treatment Outcome; Urination; Urodynamics
PubMed: 26048890
DOI: 10.2215/CJN.05410514 -
BMC Health Services Research Nov 2015The cost of dialysis in low and middle-Income countries has not been systematically reviewed. The objective of this article is to systematically review peer-reviewed... (Review)
Review
BACKGROUND
The cost of dialysis in low and middle-Income countries has not been systematically reviewed. The objective of this article is to systematically review peer-reviewed articles on the cost of dialysis across low and middle-income countries.
METHODS
PubMed and Embase databases were searched for the year 1998 to March 2013, and additional studies were added from Google Scholar search. An article was included if two reviewers agreed that it had reported cost of dialysis from low and middle-Income countries.
RESULTS
The annual cost per patient for hemodialysis (HD) ranged from Int$ 3,424 to Int$ 42,785, and peritoneal dialysis (PD) ranged from Int$ 7,974 to Int$ 47,971. Direct medical cost especially drugs and consumables for HD and dialysis solutions and tubing for PD were the main cost drivers.
CONCLUSION
The number of studies on the economics of dialysis in low and middle-income countries is limited. Few papers indicate that dialysis is an expensive form of treatment for the population of these countries and that the poorer countries have an over-proportional burden to finance dialysis services. Further research is needed to determine the cost of dialysis based on a standard methodology grounded on existing economic guidelines and to address the question whether dialysis should be an element of the essential package of health in resource-poor countries. Used data should be as complete as possible. In case of missing data, proxies can be used. In case of developing countries, expert interviews are often used for estimating missing information.
Topics: Cost-Benefit Analysis; Developing Countries; Humans; Income; Kidney Diseases; Renal Dialysis
PubMed: 26563300
DOI: 10.1186/s12913-015-1166-8 -
American Journal of Kidney Diseases :... Jun 2020The efficacy and safety of icodextrin versus glucose-only peritoneal dialysis (PD) regimens is unclear. The aim of this study was to compare once-daily long-dwell... (Meta-Analysis)
Meta-Analysis
RATIONALE & OBJECTIVE
The efficacy and safety of icodextrin versus glucose-only peritoneal dialysis (PD) regimens is unclear. The aim of this study was to compare once-daily long-dwell icodextrin versus glucose among patients with kidney failure undergoing PD.
STUDY DESIGN
Systematic review of randomized controlled trials (RCTs), enriched with unpublished data from investigator-initiated and industry-sponsored studies.
SETTING & STUDY POPULATIONS
Individuals with kidney failure receiving regular PD treatment enrolled in clinical trials of dialysate composition.
SELECTION CRITERIA FOR STUDIES
Medline, Embase, CENTRAL, Ichushi Web, 10 Chinese databases, clinical trials registries, conference proceedings, and citation lists from inception to November 2018. Further data were obtained from principal investigators and industry clinical study reports.
DATA EXTRACTION
2 independent reviewers selected studies and extracted data using a prespecified extraction instrument.
ANALYTIC APPROACH
Qualitative synthesis of demographics, measurement scales, and outcomes. Quantitative synthesis with Mantel-Haenszel risk ratios (RRs), Peto odds ratios (ORs), or (standardized) mean differences (MDs). Risk of bias of included studies at the outcome level was assessed using the Cochrane risk-of-bias tool for RCTs.
RESULTS
19 RCTs that enrolled 1,693 participants were meta-analyzed. Ultrafiltration was improved with icodextrin (medium-term MD, 208.92 [95% CI, 99.69-318.14] mL/24h; high certainty of evidence), reflected also by fewer episodes of fluid overload (RR, 0.43 [95% CI, 0.24-0.78]; high certainty). Icodextrin-containing PD probably decreased mortality risk compared to glucose-only PD (Peto OR, 0.49 [95% CI, 0.24-1.00]; moderate certainty). Despite evidence of lower peritoneal glucose absorption with icodextrin-containing PD (medium-term MD, -40.84 [95% CI, -48.09 to-33.59] g/long dwell; high certainty), this did not directly translate to changes in fasting plasma glucose (-0.50 [95% CI, -1.19 to 0.18] mmol/L; low certainty) and hemoglobin A levels (-0.14% [95% CI, -0.34% to 0.05%]; high certainty). Safety outcomes and residual kidney function were similar in both groups; health-related quality-of-life and pain scores were inconclusive.
LIMITATIONS
Trial quality was variable. The follow-up period was heterogeneous, with a paucity of assessments over the long term. Mortality results are based on just 32 events and were not corroborated using time-to-event analysis of individual patient data.
CONCLUSIONS
Icodextrin for once-daily long-dwell PD has clinical benefit for some patients, including those not meeting ultrafiltration targets and at risk for fluid overload. Future research into patient-centered outcomes and cost-effectiveness associated with icodextrin is needed.
Topics: Dialysis Solutions; Glucose; Humans; Icodextrin; Kidney Failure, Chronic; Peritoneal Dialysis; Randomized Controlled Trials as Topic; Treatment Outcome
PubMed: 32033860
DOI: 10.1053/j.ajkd.2019.10.004 -
ASAIO Journal (American Society For... Oct 2021Catheter-related bloodstream infection (CRBSI) with hemodialysis catheters are associated with increased mortality, morbidity and pose significant financial burden on... (Meta-Analysis)
Meta-Analysis
Catheter-related bloodstream infection (CRBSI) with hemodialysis catheters are associated with increased mortality, morbidity and pose significant financial burden on healthcare. Antibiotic and antimicrobial locking solutions are effective in reducing risk of CRBSI. From inception to April 2020, we looked for relevant clinical controlled trials throughout the following databases: EBSCO, PubMed, Cochrane CENTRAL, MEDLINE, EMBASE, clinicaltrial.gov, and Google Scholar performing a metanalysis comparing antibiotic and antimicrobial lock solutions to heparin. Twenty-six studies with 4,967 patients reported the incidence of catheter-related bacteremia (CRB). The overall pooled risk ratio (RR) showed that the intervention group was associated with a significantly lower incidence of CRB by 30% compared with heparin (RR = 0.30, 95% confidence interval [CI] [0.25, 0.36], p < 0.001). Subgroup analysis showed that administration of antibiotic regimens led to a decreased risk of CRB episodes by 28% compared with the heparin group (RR = 0.28, 95% CI [0.21, 0.37], p < 0.0001). Antimicrobial solutions was associated with reduced risk of CRB by 32% compared with patients of the control group (RR = 0.32, 95% CI [0.25, 0.41], p < 0.0001). A test of subgroup differences was revealed no significant favoring of any of the two interventions. Both antibiotic and antimicrobial solutions are effective in reducing CRBSI.
Topics: Anti-Bacterial Agents; Bacteremia; Catheter-Related Infections; Central Venous Catheters; Humans; Renal Dialysis
PubMed: 33587469
DOI: 10.1097/MAT.0000000000001382 -
Hemodialysis International.... Jan 2023We conducted a systematic review of studies investigating lock solutions for use in non-tunneled hemodialysis catheters.
BACKGROUND
We conducted a systematic review of studies investigating lock solutions for use in non-tunneled hemodialysis catheters.
METHODS
We searched PubMed and Cochrane databases from inception to June 11, 2021. Study inclusion criteria were: randomized trial or observational study, adults (>18 years), with acute kidney injury (AKI); and temporary non-tunneled catheters. We recorded bleeding events, catheter dysfunction and complications.
RESULTS
Of 649 studies identified, 6 were included (4 randomized, 1 non-randomized trial, 1 retrospective cohort study; sample sizes 78-1496 patients). Citrate was compared to heparin in 4 studies, to saline in 1, and ethanol versus saline in 1. Event-free survival of non-tunneled catheters did not differ between groups. Catheter-related infections and adverse events were less frequent with citrate locks, but reached statistical significance in only two studies.
CONCLUSION
Existing data are too heterogeneous to enable recommending one type of catheter lock over any other for non-tunneled hemodialysis catheters.
Topics: Adult; Humans; Retrospective Studies; Central Venous Catheters; Renal Dialysis; Catheterization; Heparin; Catheter-Related Infections; Citric Acid; Citrates; Catheters, Indwelling; Observational Studies as Topic
PubMed: 36203330
DOI: 10.1111/hdi.13047